• 제목/요약/키워드: Adhesion film

검색결과 825건 처리시간 0.026초

Developing a Testing Method for Antimicrobial Efficacy on TiO2 Photocatalytic Products

  • Kim, Jee-Yeon;Park, Chang-Hun;Yoon, Je-Yong
    • Environmental Engineering Research
    • /
    • 제13권3호
    • /
    • pp.136-140
    • /
    • 2008
  • $TiO_2$ photocatalyst has been known to exhibit a notable disinfecting activity against a broad spectrum of microorganisms. A lot of commercial $TiO_2$ photocatalyst products have been developed for antimicrobial purposes. However, a standard method has not yet been proposed for use in testing antimicrobial activity. In this study, we developed a $TiO_2$ photocatalytic adhesion test method with film as the standard testing method for the evaluation of antimicrobial activity. This method was devised by modifying the previous antimicrobial products test method, which has been widely used, and considering the characteristics of $TiO_2$ photocatalytic reaction. The apparatus for testing the antimicrobial activity was composed of a Black Light Blue (BLB) lamp as UV-A light source, a Petri dish as the cover material, and a polypropylene film as the adhesion film. The standard $TiO_2$ photocatalyst sample, Degussa P25 $TiO_2$ - coated glass, could only be used once. The optimal initial concentration of the microorganism, proper light intensity, and light irradiation time were determined to be $10^6$ CFU/mL, 1.0 mW/$cm^2$, and 3 hr, respectively, for testing and evaluating antimicrobial activity on the $TiO_2$ surface.

AlN 기판의 표면조도 및 소결온도가 Ag 후막도체의 접착강도에 미치는 영향 (Effect of surface roughness of AlN substrate and sintering temperature on adhesion strength of Ag thick film conductors)

  • 구본급
    • 한국결정성장학회지
    • /
    • 제30권3호
    • /
    • pp.83-90
    • /
    • 2020
  • 열전도성이 우수한 AlN 기판에 형성되는 Ag계 후막도체의 접착강도에 미치는 기판 표면조도 및 소결 온도의 영향을 연구하였다. 표면조도(Ra)가 0.5인 AlN 기판을 사용하여 제조한 후막도체의 접착강도가 이보다 표면조도가 크거나 또는 작은 기판을 사용하여 제조한 후막도체의 경우보다 높게 나타났다. 표면조도가 0.5보다 작은 기판의 경우 Ag 후막도체와 기판 사이의 접촉면적이 표면조도가 0.5인 기판보다 상대적으로 작아 접착강도가 작게 나타났다. 한편, 표면조도가 0.5보다 큰 기판을 사용한 경우에는 도체막이 기판에 완전히 접착되지 못하는 현상이 나타났고, 이로 인해서 접착강도가 적게 나타남을 알 수 있었다. 또한, 850℃에서 소결하여 얻어진 Ag계 후막도체 막의 표면 평활도가 다른 소결 온도에서 소결하여 얻어진 도체막의 평활도에 비해 가장 우수하였고, 이로 인해 도체막의 접착강도가 가장 높게 나타남을 알 수 있었다.

IBAD로 표면개질된 실리콘표면의 나노 트라이볼로지적 특성 (Nanotribological characteristics of silicon surfaces modified by IBAD)

  • 윤의성;박지현;양승호;공호성;장경영
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.127-134
    • /
    • 2001
  • Nano adhesion and friction between a Sj$_3$N$_4$ AFM tip and thin silver films were experimentally studied. Tests were performed to measure the nano adhesion and friction in both AFM(atomic force microscope) and LFM(lateral force microscope) modes in various ranges of normal load. Thin silver films deposited by IBAD (ion beam assisted deposition) on Si-wafer (100) and Si-wafer of different surface roughness were used. Results showed that nano adhesion and friction decreased as the surface roughness increased. When the Si surfaces were coated by pure silver, the adhesion and friction decreased. But the adhesion and friction were not affected by the thickness of IBAD silver coating. As the normal force increased, the adhesion forces of bare Si-wafer and IBAD silver coating film remained constant, but the friction forces increased linearly. Test results suggested that the friction was mainly governed by the adhesion as long as the normal load was low.

  • PDF

Graphene accelerates osteoblast attachment and biomineralization

  • Ren, Jia;Zhang, Xiaogang;Chen, Yao
    • Carbon letters
    • /
    • 제22권
    • /
    • pp.42-47
    • /
    • 2017
  • In this paper, the in vitro biocompatibility of graphene film (GF) with osteoblasts was evaluated through cell adhesion, viability, alkaline phosphatase activity, F-actin and vinculin expressions, versus graphite paper as a reference material. The results showed that MG-63 cells exhibited stronger cell adhesion, better proliferation and viability on GF, and osteoblasts cultured on GF exhibited vinculin expression throughout the cell body. The rougher and wrinkled surface morphology, higher elastic modulus and easy out-of-plane deformation associated with GF were considered to promote cell adhesion. Also, the biomineralization of GF was assessed by soaking in simulated body fluid, and the GF exhibited enhanced mineralization ability in terms of mineral deposition, which almost pervaded the entire GF surface. Our results suggest that graphene promotes cell adhesion, activity and the formation of bone-like apatite. This research is expected to facilitate a better understanding of graphene-cell interactions and potential applications of graphene as a promising toughening nanofiller in bioceramics used in load-bearing implants.

Effect of Improved Surface Wetability and Adhesion of Undulated Diamond-like Carbon Structure with r.f. PE-CVD

  • Jang, Young-Jun;Kim, Seock-Sam
    • KSTLE International Journal
    • /
    • 제9권1_2호
    • /
    • pp.22-25
    • /
    • 2008
  • This paper investigated the wetting and adhesion property of undulated DLC film with surface morphology controlled for a reduced real area of contact. The undulated DLC Films were prepared by 13.56 MHZ radio frequency plasma enhanced chemical vapor deposition (r.f. PECVD) by using nanoscale Cu dots surface on a Si (100) substrate. FE-SEM, AFM analysis showed that the after repeated deposition and plasma induced damage with Ar ions, the surface was nanoscale undulated. This phenomenon changed the surface morphology of DLC surface. Raman spectra of film with changed morphology revealed that the plasma induced damage with Ar ions significantly suppressed the graphitization of DLC structure. Also, it was observed that while the untreated flat DLC surfaces had wetting angle starting ranged from $72^{\circ}$ and adhesion force of 333ni. Had wetting angle the undulated DLC surfaces, which resemble the surface morphology of a cylindrical shape, increased up to $104^{\circ}$ and adhesion force decreased down to 11 nN. The measurements agree with Hertz and JKR models. The surface undulation was affected mainly by several factors: the surface morphology affinity to cylindrical shape, reduction of the real area of contact and air pockets trapped in cylindrical asperities of the surface.

폴리카보네이트에서의 표면개질 조건과 DC-Bias Sputtering 증착에 따른 Cu 밀착성 (Adhesion of Cu on Polycarbonate with the Condition of Surface Modification and DC-Bias Sputtering Deposition)

  • 배길상;엄준선;이인선;김상호;고영배;김동원
    • 한국표면공학회지
    • /
    • 제37권1호
    • /
    • pp.5-12
    • /
    • 2004
  • The enhancement of adhesion for Cu film on polycarbonate (PC) surface with the $Ar/O_2$ gas plasma treatment and dc-bias sputtering was studied. The plasma treatment with this reactive mixture changes the chemical property of PC surface into hydrophllic one, which is shown by the variation of contact angle with surface modification. The micro surface roughness that also gives the high adhesive environment is increased by the $Ar/O_2$ gas plasma treatment. These results were observed distinctly from the atomic force microscopy (AFM). The negative substrate dc-bias effect for the Cu adhesion on PC was also investifated. Accelerated $Ar^{+}$ lons in sheath area of anode bombard the bare surface of PC during initial stage of dc bias sputtering. PC substrate. therefore, has severe roughen and hydrophilic surface due to the physical etching process with more activated functional group. As dc-bias sputtering process proceeds, morphology of Cu film shows better step coverage and dense layer. The results of peel test show the evidence of superiority of bias sputtering for the adhesion between metal Cu and PC.C.

다양한 표면처리에 따른 리튬이온 이차전지용 파우치 필름을 위한 접착성에 관한 연구 (Study of Adhesion according to Various Surface Treatments for Lithium Ion Secondary Battery Pouch Film)

  • 김도현;배성우;조정민;유민숙;김동수
    • 한국정밀공학회지
    • /
    • 제33권3호
    • /
    • pp.231-234
    • /
    • 2016
  • Pouch film is manufactured by laminating aluminum foil, polyamide film and polypropylene film with an adhesive or extrusion resin. However, a surface treatment is required for the aluminum because bonding does not occur easily between the aluminum foil and the polymer film. Thus, for this study, surface treatment experiments were performed in order to confirm the effect on adhesion strength. First, a variety of surface treatment solutions were coated on aluminum foil, and contact angle and surface morphology analysis was carried out for the surface-treated aluminum. For lamination of the surface-treated aluminum foil with polyamide film, a polyurethane base adhesive was prepared for the adhesive strength test specimens. The adhesive strength between the aluminum foil and the polyamide film of the resulting specimens was measured (UTM). With such an experiment, it was possible to evaluate the effect on adhesive strength of the various surface treatments.

PET 필름과 전도성 페이스트의 접착성에 미치는 PET 필름 처리 영향 (Effect of PET Film Treatment on Adhesive Properties Between PET Film and Conductive Paste)

  • 홍영서;김연철
    • 공업화학
    • /
    • 제35권3호
    • /
    • pp.209-213
    • /
    • 2024
  • 전도성 페이스트와 PET 필름 사이의 접착특성 개선을 위해 PET 필름을 산과 염기를 이용하여 화학 처리와 코로나 방전처리를 통한 물리적 처리를 진행하였다. 실제 산업적 제조에 적용되는 에틸셀룰로오스와 실란 처리 셀룰로오스 나노섬유(cellulose nano fiber, CNF)를 바인더로 적용한 페이스트를 제조하고 PET 필름에 코팅하여 접착특성을 비교하였다. 코로나 방전 처리된 PET 필름에 실란 처리 CNF가 바인더로 적용된 페이스트가 코팅된 시편에서 접착특성이 최고 수준인 5B를 나타내었다. 반면, PET 필름을 산/염기로 화학처리한 경우 접착특성 개선 효과가 나타나지 않음을 확인할 수 있었다.

열가소성 폴리머 필름의 나노 응착 및 마찰 거동에 대한 온도의 영향 (The Effect of Temperature on the Nano-scale Adhesion and Friction Behaviors of Thermoplastic Polymer Films)

  • 김광섭;안등태구;김경웅
    • Tribology and Lubricants
    • /
    • 제23권6호
    • /
    • pp.288-297
    • /
    • 2007
  • Adhesion and friction tests were carried out in order to investigate the effect of temperature on the tribological characteristics of poly (methylmethacrylate) (PMMA) film using AFM. The pull-off and friction forces on the PMMA film were measured under a high vacuum condition (below $1{\times}10^{-4}$ Pa) as the temperature of the PMMA film was increased from 300 K to 420 K (heating) and decreased to 300K (cooling). Friction tests were also conducted in both high vacuum and air conditions at room temperature. When the temperature was 420 K, which is 25 K higher than the glass transition temperature $(T_g)$ of PMMA, the PMMA film surface became deformable. Subsequently, the pull-off force was proportional to the maximum applied load during the pull-off force measurement. In contrast, when the temperature was under 395 K, the pull-off force showed no correlation to the maximum applied load. The friction force began to increase when the temperature rose above 370 K, which is 25 K lower than the $T_g$ of PMMA, and rapidly increased at 420 K. Decrease of the PMMA film stiffness and plastic deformation of the PMMA film were observed at 420 K in force-displacement curves. After the heating to 420 K, the fiction coefficient was measured under the air condition at room temperature and was found to be lower than that measured before the heating. Additionally, the RMS roughness increased as a result of the heating.

DC 반응성 스퍼터링법에 의해 제조된 몰리브덴 후면전극과 기판과의 상관특성분석 (The Correlation Properties between Substrate and Molybdenum Back Contacts Fabricated by DC Magnetron Sputtering)

  • 김석기;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권3호
    • /
    • pp.149-154
    • /
    • 2000
  • Bi-layer Mo films were deposited on soda-lime glass substrates using DC magnetron supttering. Increasing gas pressure, the resistivity varied from $1\times10^{-5}\; to\; 8.3\times10^{-3}\; \Omega.cm$. Furthermore, stress direction yielded compressive-to-tensile transition stress curves. The micro-structure of the compressively-stressed film which had poor adhesion consists of tightly packed columns, but of the tensile-stressed films had less dense structure. Under all gas pressure conditions, Mo films exhibited distinctly increasing optical reflection with decreasing gas pressure. The expansion of (110) peak width with the gas pressure meant the worse crystalline growth. The impurity levels in the Mo film exhibited highly concentrated Na, Se and O elements due to less dense micro-structure. The degree of Na diffusion depends on the type of the glass substrate used and the nature of the Mo film.

  • PDF