• Title/Summary/Keyword: Adhesion Strength

Search Result 1,338, Processing Time 0.023 seconds

Proposal of Bond Strength Evaluation Method for Overlay Concrete at Field (유한요소해석을 이용한 현장 덧씌우기 콘크리트의 부착강도 평가 방법 제안)

  • Lee, Bong-Hak;Hong, chang-Woo;Lee, Joo-Hyung;Kim, Seong-Hwan
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.295-300
    • /
    • 2001
  • Significant improvements in bond strength between new and existing concrete can be achieved through the modification of the new concrete by latex modification. But, no test method has been adopted as a standard to measure the bond strength between the concrete used to repair and the substrate being repaired. The performance of old and the new concrete construction defends upon band strength between old and the new concrete. Current adhesion strength measurement method is inaccurate method that ignore effect of stress concentration by shape of specimens. Therefore, this research calculates stress concentration coefficient using finite element analysis and direction tensile strength test (pull-off test). The result shows that the required core depth is 2.5 cm. Elastic modulus and overlay thickness do not influence in stress concentration.

  • PDF

Proposal of Bond Strength Evaluation Method for Bridge Deck Overlay (교면 덧씌우기 콘크리트의 부착강도 평가 방법 제안)

  • 장흥균;홍창우;정원경;이봉학;윤경구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.349-354
    • /
    • 2002
  • Significant improvements in bond strength between new and existing concrete can be achieved through the modification of the new concrete by latex modification. But, no test method has been adopted as a standard to measure the bond strength between the concrete used to repair and the substrate being repaired. The performance of old and the new concrete construction depends upon bond strength between old and the new concrete. Current adhesion strength measurement method ignores the effect of stress concentration by shape of specimens. Therefore, this research calculates stress concentration coefficient using finite element analysis and direction tensile strength test (pull-off test). The result shows that the required core depth is 2.5cm. Elastic modulus and overlay thickness do not influence in stress concentration.

  • PDF

Evaluation on Effectiveness for Preventing Post Surgical Adhesion of Sodium Hyaluronate/Sodium Carboxymethyl Cellulose (HA/CMC) Membrane in Rat Cecum/Peritonium Model (쥐 맹장/복벽 찰과상 모델에서 Sodium Hyaluronate/sodium Carboxymethyl Cellulose 멤브레인의 수술 후 유착방지에 대한 유효성 평가)

  • Lee, Young-Moo;Lee, Young-Woo
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.213-223
    • /
    • 2005
  • We prepared an anti-adhesion membrane made of sodium hyaluronate/sodium carboxymethylcellulose (HA/CMC) and evaluated its effectiveness for adhesion prevention in a rat model. The anti-adhesion membrane was prepared by lyophilizing HA/CMC solution and cross-linking properly with 1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDAC). In a cecum/abdominal wall abrasion model of Sprague-Dawley rat, cecal serosa and abdominal wall were abraded in $1\times2\;(cm^2)$ with a bone burr after peritoneal midline incision and sutured at 3 points around the injured surface. The denuded cecum was covered with HA/CMC membrane (experimental group), or nothing (control group) and apposed to the abdominal wall. Most of the control group represented 3 or more of adhesion grade at POD 7, 14, 21, and 28, whereas $60\~70\%$ of the experimental group was 2 or less of adhesion grade at 14, 21, and 28. It was similar in the adhesion strength. In a general manner, the adhesion grade and strength showed gradual increasing until POD 14, almost same or a little increasing POD 21, but decreasing POD 28. Also the control group was much higher in adhesion grade, strength, and area than the experimental group. It is expected that the anti-adhesion membrane will have a good clinical result in postoperative adhesion prevention.

Evaluation of Mechanical Performance and Flame Retardant Characteristics of Biomass-based EVA Composites using Intumescent Flame Retardant Technology

  • Park, Ji-Won;Kim, Hoon;Lee, Jung-Hun;Jang, Seong-Wook;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.189-201
    • /
    • 2018
  • Intumescent system is a highly effective flame retardant technology that takes advantage of the mechanism of foaming and carbonization. In order to materialize Intumescent system, it is necessary to use reinforcement material to improve the strength of the material. In this study, we used kenaf as a natural fiber to manufacture intumescent/EVA (ethylene vinyl acetate) composites to improve mechanical and flame retardant performance. Finally two materials with different particle shape are applied to one system. Therefore, the influence factors of the particles with different shapes on the composite material were analyzed based on the tensile test. For this purpose, we have used the tensile strength analysis model and confirmed that it can only act as a partial strength reinforcement due to weak binding force between the matrix and particles. In the combustion characteristics analysis using cone calorimeter and UL 94, the combustion characteristics were enhanced as the content of Intuemscent was increased. As the content of kenaf increased, combustion characteristics were strengthened and carbonization characteristics were weakened. Through the application of kenaf, it can be confirmed that elastic modulus improvement and combustion characteristics can be strengthened, which confirmed the possibility of development of environmentally friendly flame retardant materials.

Improvement of Polyimide/Epoxy Adhesion Strength from the Modification of Polyimide Surface and Epoxy Adhesive (폴리이미드 표면개질과 에폭시접착제 개질을 통한 폴리이미드/에폭시의 접착력 향상)

  • Kim, Seong-Hun;Lee, Dong-U;Jeong, Gyeong-Ho
    • Korean Journal of Materials Research
    • /
    • v.9 no.1
    • /
    • pp.65-72
    • /
    • 1999
  • In order to minimize flexible printed circuit(FPC), which is used in computer, communication, medical facility, aviation space industry, it is required to improve the interfacial adhesion of polymide/epoxy or polyimide/polyimide consists of FPC. In this study, it was considered to improve the adhesion strength of polyimide/epoxy joint by introducing functional group on polyimide film and improving mechanical property of epoxy. Functional group on polyimide film was introduced by changing polyimide film surface to polyamic acid in KOH aqueous solution. The optimum conditions for surface modification were the concentration of 1M KOH and treatment time of 5min. Also, the optimum adhesion strength of polyimide/epoxy joint was obtained using rubber modified epoxy and polyamic acid as a base resin and curing agent of epoxy adhesive, respectively. The degree of surface modification of polyimide film examined with contact angle measurement of FTIR, thus modification of polyimide to polyamic acid was identified. Fracture surface of plymide/epoxy joint was analyzed by scanning electron microscopy, and modified polyamic acid reimidezed to polymide as increasing curing temperature.

  • PDF

Modification of Polypropylene for Improving the Laser Transmission Weldability to Polycarbonate (폴리카보네이트와의 레이저 투과 용접성 개선을 위한 폴리프로필렌 개질)

  • Kim, Dae-Jin;Jeon, Il-Ryeon;Park, Hae-Youn;Seo, Kwan-Ho
    • Polymer(Korea)
    • /
    • v.37 no.6
    • /
    • pp.753-763
    • /
    • 2013
  • Laser transmission welding of polymers is now used in a very wide range of industries due to its advantages. If the joining between polypropylene (PP) and polycarbonate (PC) occurs by laser transmission welding, the automotive headlight will get a large profit. However, PP/PC have poor miscibility. In the laser transmission welding results, the adhesion strength between PP and PC was very weak. In this study, PP was modified by grafting of glycidyl methacrylate (GMA). The adhesion strength of PC and PP-g-GMA as a reactive compatibilizer was observed. The adhesion strength was investigated by compatibility with PC, mechanical properties and laser transmission welding.

Synthesis and Application of Solvent-free Waterborne Polyurethane (SWPU) Using Teramethylxylene diisocyanate (TMXDI) (Teramethylxylene diisocyanate (TMXDI)를 사용한 무용제형 수분산 폴리우레탄의 합성 및 응용)

  • Jeong, Boo Young;Cheon, Jung Mi;Yoo, Chong Sun;Chun, Jae Hwan
    • Journal of Adhesion and Interface
    • /
    • v.8 no.4
    • /
    • pp.8-13
    • /
    • 2007
  • In this study, solvent-free waterborne polyurethanes (SWPU) were synthesized with teramethylxylene diisocyanate (TMXDI), poly(tetramethylene glycol) (PTMG) and polycarprolactone (PCL) and different mole ratio of dimethylol proponicacid (DMPA). The effect of ionic contents in the solvent-free waterborn polyurethane on thermal, mechanical properties and adhesion strength were studied. Glass transition temperature (Tg) were in range of $-70{\sim}-50^{\circ}C$ and increased as PCL contents increased in polyol. With more incorporation of PCL and DMPA contents in SWPU, tensile strength, adhesion strength and heat resistance of SWPU increased, while the elongation decreased.

  • PDF

Measurement of Adhesion (접착력의 측정)

  • Kim, Sung-Ryong;Lee, Ho-Young
    • Journal of Adhesion and Interface
    • /
    • v.4 no.3
    • /
    • pp.21-32
    • /
    • 2003
  • Various methods for adhesion measurement, which are related to previously published paper [J. of Soc. of Adhe. and Inter, 3,4 (2002)], are reviewed. At first, the prerequisite for the ideal adhesion strength measurement is considered, and three categories of methods for adhesion measurement, such as mechanical, non-mechanical methods and miscellaneous methods, are introduced.

  • PDF

Adhesion Performance of Natural Rubber-based Pressure-Sensitive Adhesives for Protecting of Opto-functionalized Sheet (광기능성시트 보호용 천연고무계 점착제의 점착 물성)

  • Park, Young-Jun;Lim, Dong-Hyuk;Kim, Hyun-Joong;Song, Hyun-Suk;Kwon, Hyuk-Jin
    • Journal of Adhesion and Interface
    • /
    • v.8 no.2
    • /
    • pp.15-21
    • /
    • 2007
  • To prepare a natural rubber-based pressure-sensitive adhesive (PSA) for protection film of opto- functionalized sheet, natural rubber (NR) was blended with a DCPD type tackifier and three types of aliphatic hydrocarbon resins, respectively. Also, to supply low cohesion strength of NR, in the fixed ratio of tackifier, synthetic rubber, styrene-isoprene-styrene (SIS) block copolymer was blended with NR as a function of SIS contents. PSA performance of prepared PSAs was evaluated using probe tack and peel strength. Probe tack of NR/tackifier blends was increased with increasing tackifier contents, and showed maximum peak. In addition, probe tack of NR/tackifier blends slightly increased with increasing softening point of aliphatic hydrocarbon resins. Their peel strength increased up to 50 wt% of tackifier contents, but in the over contents of tackifier, they showed stick-slip failure mode. Finally, probe tack of NR/SIS/tackifier blends showed the maximum values at 20~40 wt% of tackifier contents, but at 20 wt% of tackifier contents, they showed fibrillation. For this reason, peel strength showed maximum values at 40 wt% of tackifier contents.

  • PDF

Focal adhesion linker proteins expression of fibroblast related to adhesion in response to different transmucosal abutment surfaces

  • Moon, Yeon-Hee;Yoon, Mi-Kyeong;Moon, Jung-Sun;Kang, Jee-Hae;Kim, Sun-Hun;Yang, Hong-Seo;Kim, Min-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.341-350
    • /
    • 2013
  • PURPOSE. To evaluate adherence of human gingival fibroblasts (HGFs) to transmucosal abutment of dental implant with different surface conditions with time and to investigate the roles of focal adhesion linker proteins (FALPs) involved in HGFs adhesion to abutment surfaces. MATERIALS AND METHODS. Morphologies of cultured HGFs on titanium and ceramic discs with different surface were observed by scanning electron microscopy. Biocompatibility and focal adhesion were evaluated by ultrasonic wave application and cell viability assay. FALPs expression levels were assessed by RT-PCR and western blot. RESULTS. There seemed to be little difference in biocompatibility and adhesion strength of HGFs depending on the surface conditions and materials. In all experimental groups, the number of cells remaining on the disc surface after ultrasonic wave application increased more than 2 times at 3 days after seeding compared to 1-day cultured cells and this continued until 7 days of culture. FALPs expression levels, especially of vinculin and paxillin, also increased in 5-day cultured cells compared to 1-day cultured fibroblasts on the disc surface. CONCLUSION. These results might suggest that the strength of adhesion of fibroblasts to transmucosal abutment surfaces increases with time and it seemed to be related to expressions of FALPs.