• Title/Summary/Keyword: Adhesion Measurement

Search Result 239, Processing Time 0.028 seconds

Destructive testing of adhesively bonded joints under static tensile loading

  • Ochsner, A.;Gegner, J.
    • Journal of Adhesion and Interface
    • /
    • v.5 no.2
    • /
    • pp.22-36
    • /
    • 2004
  • Several in-situ testing methods of adhesively bonded joints under static short-time tensile loading are critically analyzed in terms of experimental procedure and data evaluation. Due to its rather homogeneous stress state across the glue line, the tensile-shear test with thick single-lap specimens, according to ISO 11003-2, has become the most important test process for the determination of realistic materials parameters. This basic method, which was improved in both, the experimental part by stepped adherends and easily attachable extensometers and the evaluation procedure by numeric substrate deformation correction and test simulation based on the finite element method (FEM), is therefore demonstrated by application to several kinds of adhesives and metallic adherends. Multi-axial load decreases the strength of a joint. This effect, which is illustrated by an experimental comparison, impedes the derivation of realistic mechanical characteristics from measured force-displacement curves. It is shown by numeric modeling that tensile-shear tests with thin plate substrates according to ISO 4587, which are widely used for quick industrial quality assurance, reveal an inhomogeneous stress state, especially because of relatively large adherend deformation. Complete experimental determination of the elastic properties of bonded joints requires independent measurement of at least two characteristics. As the thick-adherend tensile-shear test directly yields the shear modulus, the tensile butt-joint test according to ISO 6922 represents the most obvious complement of the test programme. Thus, validity of analytical correction formulae proposed in literature for the derivation of realistic materials characteristics is verified by numeric simulation. Moreover, the influence of the substrate deformation is examined and a FEM correction method introduced.

  • PDF

A Study on External Effects on Peeling-off Behavior of Adhesive Tape (접착 테이프 박리거동에 미치는 외부효과에 관한 연구)

  • Han, Won Heum;Jung, Hyung Sik;Lee, Moon Ho
    • Journal of Adhesion and Interface
    • /
    • v.13 no.1
    • /
    • pp.9-16
    • /
    • 2012
  • In order to describe external effects on the behavior of the adhesive tape, the semi-rigid body cylinder chain model for adhesive tape has been proposed as follows. Firstly the behavior of the tape is in detail investigated while it's being pulled off from the plate, and subsequently a relevant phenomenological model is designed. Then all the contributors affecting the force to peel out the tape from plate (hereafter, the pull out force) are clearly defined and their sensitivity analyses are made to set up the experimental reference condition, under which the angular dependence of the pull out force is measured in every $10^{\circ}$. The experimental data turn out to be in good agreement with the theoretical ones by our model within the measurement error, and the effects due to other factors are proved to be well explained from the phenomenological viewpoint. From these results, the concept of this study might be expected to be very useful for the test and evaluation of PSA types of adhesive tape.

Synthesis and Properties of PEGMA/Na-MMT with Acrylic Monomer by Free-Radical Polymerization (Free Radical 중합에 의한 PEGMA/Na-MMT와 아크릴단량체의 합성 및 물성)

  • Joo, Hong Hee;Park, Chan Young;Kim, Tae Kyoon;Chun, Jae Hwan;Lee, Won Kee;Oh, Sang Taek
    • Journal of Adhesion and Interface
    • /
    • v.11 no.3
    • /
    • pp.106-111
    • /
    • 2010
  • Na-MMT intercalated with PEGMA macromer was prepared using an EtAc/acetone mixture (1/1 by volume) as a solvent. PEGMA/(Na-MMT)-co-MMA/MA nanocomposites was synthesized by copolymerizing intercalated compound with MMA and MA, and then characterization was performed. The results of X-ray diffraction (XRD) showed that in the case of Na-MMT intercalated with PEGMA macromer the d-spacings of silicate of Na-MMT increased with increasing of Na-MMT loading. As the Na-MMT loading increases Tg showed increasing trend through the DSC measurement. TGA result showed that thermal stability of PEGMA/(Na-MMT)-co-MMA/MA nanocomposites improved a little more than the pure PEGMA-co-MMA/MA.

A Study on the Cytotoxic Effects of Several Plant Extracts on the Cell viability and Cell Adhesion Activity in Cultured NIH3T3 Fibroblast (몇 가지 식물추출물이 배양 NIH3T3 섬유모세포의 세포생존율과 세포부착률에 미치는 세포독성에 관한 연구)

  • Rim, Yo-Sup;Song, Won-Seob;Seo, Young-Mi;Park, Seung-Taeck;Kim, Shin-Moo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.42 no.3
    • /
    • pp.116-124
    • /
    • 2010
  • This study was aimed to clerify the cytotoxicity of some plant extracts such as Hosta longissima HONDA (HL), Hemerocallis fulva var. Kwanso REGL (HFVK), Hemerocallis fulva L (HF), Macrocapium officinale NAKAI (MO) and Mentha canadensis var. piperascens HARA (MCVP), the cultured NIH3T3 fibroblasts were treated with 25, 50, 100, 150 and $200{\mu}g/mL$ of five kinds of plant extracts for 48 hours, respectively. The cytotoxicity of plant extracts was measured by MTT and NR assays for the cell viability, and XTT assay for the cell adhesion activity. In this study, HL, MO and FHVK extracts showed the range of midtoxic-non toxic by the criteria of chemical cytotoxicity. While, the HF and MCVP extracts showed midtoxic. In the extract cytotoxicity, HL, MO and FHVK extracts showed non-toxic by the criteria of extract cytotoxicity. While, HF extract was determined as lower-toxic. In the responsive sensitivity of each plant extract on colorimetric assays, HF extract was sensitive to mitochondrial enzyme by MTT assay, lysosomal enzyme by NR assay and mitochondrial nucleus by XTT assay. While, MCVP extract was sensitive to mitochondrial enzyme by MTT assay and lysosomal enzyme by NR assay than other assays. While, HL, HFVK and MO extracts were most sensitive to NR assay. Cell culture is one of useful materials in the screening of cytotoxic and recovary effect on the putative chemical agents or plant extract. And also, colorimetric assay is regarded as very useful tools for quantitative measurement of cytotoxic effect on plant extracts in vitro.

  • PDF

Surface Modification and Fibrovascular Ingrowth of Porous Polyethylene Anophthalmic Implants

  • Yang, Hee-Seok;Park, Kwi-Deok;Son, Jun-Sik;Kim, Jae-Jin;Han, Dong-Keun;Park, Byung-Woo;Baek, Se-Hyun
    • Macromolecular Research
    • /
    • v.15 no.3
    • /
    • pp.256-262
    • /
    • 2007
  • The purpose of this study was to determine the effect of surface modification on the fibrovascular ingrowth into porous polyethylene (PE) spheres ($Medpor^{(R)}$), which are used as an anophthalmic socket implant material. To make the inert, hydrophobic PE surface hydrophilic, nonporous PE film and porous PE spheres were subjected to plasma treatment and in situ acrylic acid (AA) grafting followed by the immobilization of arginine-glycine-aspartic acid (RGD) peptide. The surface-modified PE was evaluated by performing surface analyses and tested for fibroblast adhesion and proliferation in vitro. In addition, the porous PE implants were inserted for up to 3 weeks in the abdominal area of rabbits and, after their retrieval, the level of fibrovascular ingrowth within the implants was assessed in vivo. As compared to the unmodified PE control, a significant increase in the hydrophilicity of both the AA-grafted (PE-g-PAA) and RGD-immobilized PE (PE-g-RGD) was observed by the measurement of the water contact angle. The cell adhesion at 72 h was most notable in the PE-g-RGD, followed by the PE-g-PAA and PE control. There was no significant difference between the two modified surfaces. When the cross-sectional area of tissue ingrowth in vivo was evaluated, the area of fibrovascularization was the largest with PE-g-RGD. The results of immunostaining of CD31, which is indicative of the degree of vascularization, showed that the RGD-immobilized surface could elicit more widespread fibrovascularization within the porous PE implants. This work demonstrates that the present surface modifications, viz. hydrophilic AA grafting and RGD peptide immobilization, can be very effective in inducing fibrovascular ingrowth into porous PE implants.

Development of Mechanically Expanded Gelatin-AAc-PLLA/PLCL Nanofibers for Vascular Tissue Engineering by Radiation-based Techniques (방사선 기반에 의한 기계적으로 공극을 증가시킨 젤라틴이 도입된 혈관조직공학용 PLLA/PLCL 나노섬유 지지체의 개발)

  • Jeong, Jin-Oh;Jeong, Sung In;Seo, Da-Eun;Park, Jong-Seok;Gwon, Hui-Jeong;Ahn, Sung-Jun;Shin, Young Min;Lim, Youn-Mook
    • Journal of Radiation Industry
    • /
    • v.9 no.4
    • /
    • pp.171-180
    • /
    • 2015
  • Vascular tissue engineering has been accessed to mimic the natural composition of the blood vessel containing intima, media, and adventitia layers. We fabricated mechanically expanded PLLA/PLCL nanofibers using electrospinning and UTM. The pore size of the meshes was increased the gelatin immobilized AAc-PLLA/PLCL nanofibers ($203.30{\pm}49.62microns$) than PLLA/PLCL nanofibers ($59.99{\pm}8.66microns$) after mechanical expansion. To increase the cell adhesion and proliferation, we introduced carboxyl group, and gelatin was conjugated on them. The properties of the PLLA/PLCL nanofibers were analyzed with SEM, ATR-FTIR, TBO staining, and water contact angle measurement, general cell responses on the PLLA/PLCL nanofibers such as adhesion, proliferation, and infiltration were also investigated using smooth muscle cell (SMC). During the SMC culture, the initial viability of the cells was significantly increased on the gelatin immobilized AAc-PLLA/PLCL nanofibers, and infiltration of the cells was also enhanced on them. Therefore, gelatin immobilized AAc-PLLA/PLCL nanofibers and mechanically expanded meshes may be a good tool for vascular tissue engineering application.

Measurement of Adhesion Strength and Nanoindentation of Metal Interconnections of Al/Ni and TiW/Ni Layers Formed on Glass Substrate (유리기판 위에 형성된 Al/Ni 및 TiW/Ni 다층 금속배선막의 계면 접합력 및 나노압입특성 평가)

  • Joe, Chul Min;Kim, Jae Ho;Hwang, So Ri;Yun, Yeo Hyeon;Oh, Yong Jun
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.12
    • /
    • pp.1116-1122
    • /
    • 2010
  • Metal interconnections of multilayer Al/Ni and TiW/seed-Ni/Ni were formed on glass, and the adhesion strength and nanoindentation response of the composite layers were evaluated. The Al/Ni multilayer was formed by an anodic bonding of glass to Al and subsequent electroless plating of Ni, while the TiW/Ni multilayer was fabricated by sputter deposition of TiW and seed-Ni onto glass and electroless plating of Ni. Because of the diffusion of aluminum into glass during the anodic bonding, anodically bonded glass/Al joint exhibited greater interfacial strength than the sputtered glass/TiW one. The Al/Ni on glass also showed excellent resistance against delamination by bending deformation compared to the TiW/seed-Ni/Ni on glass. From the nanoindentation experiment of each metal layer on glass, it was found that the aluminum layer had extremely low hardness and elastic modulus similar to the glass substrate and played a beneficial role in the delamination resistance by lessening stress intensification at the joint. The indentation data of the multilayers also supported superior joint reliability of the Al/Ni to glass compared to that of the TiW/seed-Ni/Ni to glass.

Surface Modification of Polymer Films by Vapor Phase Photografting of Functional Monomers (기상 UV 그라프트 반응에 의한 고분자 필름의 표면 개질)

  • Oh, Seung Hee;Oh, Se Heang;Lee, Jin Ho
    • Journal of Adhesion and Interface
    • /
    • v.1 no.1
    • /
    • pp.23-29
    • /
    • 2000
  • Surface modification of hydrophobic polymeric materials to be hydrophilic or to have specific functional groups is of great importance for a diversity of applications of the materials. In this study, polyethylene (PE) film surfaces were modified by vapor phase photografting of hydrophilic vinyl monomers with different functional groups. The functional monomers were introduced on PE films by introducing the monomers in vapor phase using a vapor phase photografting apparatus designed by our laboratory. Functional monomers used were acrylic acid (negatively chargeable), acrylamide and allylalcohol (neutral), and allylamine and N,N-dimethyl aminopropyl acryamide (positively charged). The functional monomer-grafted PE film surfaces were characterized by the measurement of water contact angles and the attenuated total reflectance Fourier-transform infrared spectroscopy. The vapor phase photografting seems to be effective means for introduction of various functional groups onto polymeric substrates.

  • PDF

The Clinical Application of Sound-Protection

  • Tomohiko, Kamio
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1976.06a
    • /
    • pp.87.1-87
    • /
    • 1976
  • Bekesy measured the sound transformation system of the middle ear 49 years ago. According to his reports, a ratio between the size of ear drum and the size of oval window is 17 : 1, and the lever function of the ossicles is physiologically 1.3 : 1. Therefore, the hearing might be aggravated to 27.5㏈ in the case of the vanishment of 3 ossicles. In 1952, Wullstein reported 5 types of tympanop-lasty and the fourth type among them was especially named for the sound-protection. The oval window is only exposed by the sound pressure and the round window is not exposed. According to the application by this idea, the post-operative hearing might be improved until 27.5㏈. Mean while, in 1942, Onchi verified through his experiment that the results of Bekesy's measurement was not completely conformed to Onchi result. Bekesy measured the sound pressure on the stapes plate of the oval window, on the other hand, Onchi measured the sound pressure on the surface of the perilymph of the oval window after removing the stapes plate(Fig. 1).(Figure omitted) The difference of their experiment is recognized that the impedance of the stapes plate exists or not (Fig. 1). Both Audiogrums are compared as Fig. 2. The result of IV type of tympanoplasty is success ful in 54% as the Table 1. (Table Omitted) The reason of unsatisfactory is caused by the thick and unmovable window-membrane and by the closing of air passage to the round window. The closing of the air passage to the round window is occurred by the adhesion between the grafting membrane and the surface of promontorium. In order to preserve this adhesion, I produce to transplantate the mucous membrane of the lip to the bone surface of tympanic cavity after removing the granulation tissue of the tympanic cavity and to form a membranous canal for the sake of air passage (Fig. 3). (Figure Omitted) The post-operative hearing by this method is shown as Fig. 4, 5. In other words, the post-operative sound pressure entered into the cochlea directly, by way of the oval window only, not by way of the round window, as a theorie of the sound protection. (Figure omitted)

  • PDF

PVP Hydrogel Coatings on Polypropylene Fibers using E-beam Irradiation (전자 빔을 이용한 폴리프로필렌 섬유의 PVP 하이드로젤 코팅)

  • Lee, Ji Eun;kwak, Hyo-Bin;Lee, Yong-Hyo;Kim, Kyung-Min;Lim, Jung-Hyurk
    • Journal of Adhesion and Interface
    • /
    • v.20 no.2
    • /
    • pp.66-70
    • /
    • 2019
  • The surface of hydrophobic polypropylene (PP) fibers (spun-bonded fabric) was treated by an atmospheric plasma treatment method. These pre-treated hydrophilic PP fabrics were dip-coated in the aqueous poly(N-vinyl pyrrolidone) (PVP) solution. PVP layers on the surface of PP fiber were crosslinked by an irradiation of electron beam. The thickness of PVP hydrogels coated on the surface was easily controlled by changing the concentration of PVP in coating solution. The stepwise surface treatment, PVP coating, and hydrogel formation via electron beam irradiation were analyzed by the measurement of contact angle, scanning electron microscopy, and optical microscopy.