• Title/Summary/Keyword: Additional ratio

Search Result 1,372, Processing Time 0.025 seconds

A Zero Voltage Switching Phase Shift Full Bridge Converter with Separated Primary Winding

  • Kim, Young-Do;Kim, Chong-Eun;Cho, Kyu-Min;Park, Ki-Bum;Cho, In-Ho;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.379-381
    • /
    • 2008
  • Generally additional leakage inductance and two clamp diodes are adopted into the conventional phase shift full bridge (PSFB) converter for reducing the voltage stress of secondary rectifier diodes and extending the range of zero voltage switching (ZVS) operation. However, since additional leakage inductance carries the ac current similar to the primary one, the core and copper loss oriented from additional leakage inductance can be high enough to decrease the whole efficiency of DC/DC converter. Therefore, in this paper, a new ZVS phase shift full bridge converter with separated primary winding (SPW) is proposed. Proposed converter makes the transformer and additional leakage inductor with one ferrite core. Using this method, leakage inductance is controlled by the winding ratio of separated primary winding. Moreover, by manufacturing the both magnetic components with one core, size and core loss can be reduced and it turns out the improvement of efficiency and power density of DC/DC converter. The operational principle of proposed converter is analyzed and verified by the 1.2kW prototype.

  • PDF

Cracking and bending strength evaluations of steel-concrete double composite girder under negative bending action

  • Xu, Chen;Zhang, Boyu;Liu, Siwei;Su, Qingtian
    • Steel and Composite Structures
    • /
    • v.35 no.3
    • /
    • pp.371-384
    • /
    • 2020
  • The steel-concrete double composite girder in the negative flexural region combines an additional concrete slab to the steel bottom flange to prevent the local steel buckling, however, the additional concrete slab may lower down the neutral axis of the composite section, which is a sensitive factor to the tensile stress restraint on the concrete deck. This is actually of great importance to the structural rationality and durability, but has not been investigated in detail yet. In this case, a series of 5.5 m-long composite girder specimens were tested by negative bending, among which the bottom slab configuration and the longitudinal reinforcement ratio in the concrete deck were the parameters. Furthermore, an analytical study concerning about the influence of bottom concrete slab thickness on the cracking and sectional bending-carrying capacity were carried out. The test results showed that the additional concrete at the bottom improved the composite sectional bending stiffness and bending-carrying capacity, whereas its effect on the concrete crack distribution was not obvious. According to the analytical study, the additional concrete slab at the bottom with an equivalent thickness to the concrete deck slab may provide the best contributions to the improvements of crack initiation bending moment and the sectional bending-carrying capacity. This can be applied for the design practice.

Adverse Effects of Chloral Hydrate in Neonates: Frequency and Related Factors (신생아에서 Chloral Hydrate의 부작용의 빈도와 관련 인자)

  • Lee, Ju-Young;Youn, Young-Ah;Kim, Soon-Ju;Lee, Hyun-Seung;Kim, So- Young;Sung, In-Kyung;Chun, Chung-Sik
    • Neonatal Medicine
    • /
    • v.18 no.1
    • /
    • pp.130-136
    • /
    • 2011
  • Purpose: Chloral hydrate is a common drug frequently used for procedural sedation. But data on chloral hydrate use in the newborns are limited. This study examined the frequency of adverse effects of chloral hydrate and factors related to the adverse effects. We also examined if there were additional adverse effects when an additional sedative was used. Methods: The medical records of 104 patients admitted to neonatal intensive care unit of Seoul St. Mary's Hospital from March 2010 to February 2011 who used chloral hydrate for procedural sedation were retrospectively reviewed. Results: Adverse effects after administration of chloral hydrate were noted in 41.3% of the 104 patients. The adverse events included oxygen desaturation (18.8%), increase in apneic episodes (17.5%), increase in bradycardia (10%), and feeding intolerance (3.8%). Using oxygen at the time of chloral hydrate administration was independently associated with adverse effects (odds ratio [OR], 10.911: 95% confidence interval [CI], 2.082-57.178) and with the necessity for an additional sedative after administration of chloral hydrate (OR, 4.151: 95% CI, 1.455-11.840). Using one additional sedative agent after chloral hydrate showed no difference in adverse effects except feeding intolerance. Conclusion: Patients dependent on oxygen at the time of chloral hydrate administration may were found to be at higher risk for adverse effect of chloral hydrate and for an additional sedative. When an additional sedative is needed, it could be used with monitoring feeding intolerance after chloral hydrate administration.

Risk factor analysis of additional administration of sedative agent and patient dissatisfaction in intravenous conscious sedation using midazolam for third molar extraction

  • Shin, Dong-Whan;Cho, Jin-Yong;Han, Yoon-Sic;Sim, Hye-Young;Kim, Hee-Sun;Jung, Da-Un;Lee, Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.4
    • /
    • pp.229-238
    • /
    • 2017
  • Objectives: The primary purpose of this study was to investigate the factors related with additional administration of sedative agent during intravenous conscious sedation (IVS) using midazolam (MDZ). The secondary purpose was to analyze the factors affecting patient satisfaction. Materials and Methods: Clinical data for 124 patients who had undergone surgical extraction of mandibular third molar under IVS using MDZ were retrospectively investigated in this case-control study. The initial dose of MDZ was determined by body mass index (BMI) and weight. In the case of insufficient sedation at the beginning of surgery, additional doses were injected. During surgery, peripheral oxygen saturation, bispectral index score (BIS), heart rate, and blood pressure were monitored and recorded. The predictor variables were sex, age, BMI, sleeping time ratio, dental anxiety, Pederson scale, and initial dose of MDZ. The outcome variables were additional administration of MDZ, observer's assessment of alertness/sedation, intraoperative amnesia, and patient satisfaction. Descriptive statistics were computed, and the P-value was set at 0.05. Results: Most patients had an adequate level of sedation with only the initial dose of MDZ and were satisfied with the treatment under sedation; however, 19 patients needed additional administration, and 13 patients were unsatisfied. In multivariable logistic analysis, lower age (odds ratio [OR], 0.825; P=0.005) and higher dental anxiety (OR, 5.744; P=0.003) were related to additional administration; lower intraoperative amnesia (OR, 0.228; P=0.002) and higher BIS right before MDZ administration (OR, 1.379; P=0.029) had relevance to patient dissatisfaction. Conclusion: The preoperative consideration of age and dental anxiety is necessary for appropriate dose determination of MDZ in the minor oral surgery under IVS. The amnesia about the procedure affects patient satisfaction positively.

Poll System using E-mails

  • Kim, Yon Hyong;Oh, Min Gweon
    • Communications for Statistical Applications and Methods
    • /
    • v.8 no.3
    • /
    • pp.767-775
    • /
    • 2001
  • In this paper we propose a poll system using e-mail. This system expects to increase the response ratio because of including a questionnaire inner e-mail. Especially, this system automatically provides a general paper which is a result of categorical data analysis.

  • PDF

MEASUREMENT OF $CO_2$ CONCENTRATION AND A/F RATIO USING FAST NDIR ANALYZER ON TRANSIENT CONDITION OF SI ENGINE

  • Lee, S.W.;Kim, W.S.;Lee, J.H.;Park, J.I.;Yoo, J.S.
    • International Journal of Automotive Technology
    • /
    • v.7 no.4
    • /
    • pp.385-390
    • /
    • 2006
  • A fast response $CO_2$ analyzer has been developed to study transient characteristics on an SI engine. The analyzer has the delay time of 4.5 ms and time constant of 2.8 ms, which is fast enough to measure $CO_2$ concentration on a transient condition. Wide range of A/F(Air/Fuel) ratio can be estimated using the analyzer with an additional switch type oxygen sensor. The results of measurement of $CO_2$ concentration and A/F ratio on a transient condition including rapid acceleration/deceleration and EGR(Ehxaust Gas Recirculation) on/off are presented and compared with a commercial exhaust gas analyzer and UEGO(Universial Exhaust Gas Oxyzen) sensor.

CDMA Pilot Receiving Circuit Using Sequence Estimator (시퀀스 추정기를 사용하는 CDMA 파일럿 수신회로)

  • Lee, Seong-Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.32-38
    • /
    • 2006
  • In this paper a sequence estimator of CDMA communication system is suggested. A sequence estimator uses Galois Field operation. A sequence estimator can provide another CDMA pilot signal which is un-modulated spreaded signal. A estimated sequence signal and received signal have no correlation. Tow signals can be summed using MRC(maximal ratio combine) method. The stronger signal can be added as a larger ratio, but the weaker signal can be added as a smaller ratio. We can distinguish strong signal using SNR estimator. Therefore it is possible to receive an additional pilot signal, and to support more reliable communications by using sequence estimator.

Effects of excitation characteristics on the equivalent linear system of a building structure with MR dampers (MR감쇠기가 설치된 구조물의 등가선형 시스템에 대한 가진 특성의 영향)

  • Park, Ji-Hun;Min, Kyung-Won;Moon, Byoung-Wook;Park, Eun-Churn
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.503-510
    • /
    • 2006
  • Seismic control performance of MR dampers, which have severe nonlinearity, differs with respect to the dynamic characteristics of an earthquake such as magnitude, frequency and duration. In this study, the effects of excitation characteristics on the equivalent linear system of a building structure with an MR damper are investigated through numerical analysis for artificial ground motions generated from different response spectrums. The equivalent damping ratio of the structure with an MR damper is calculated using Newmark and Hall's equations for ground motion amplification factors. It is found that the equivalent damping ratio of the structure with the MR damper is dependent on the ratio of the maximum friction force of the MR damper over excitation magnitude. Frequency contents of the earthquake ground motion affects the equivalent damping ratio of long-period structures considerably. Also, additional damping effect caused by interaction between the viscousity and friction of the MR damper is observed.

  • PDF

The Development of Educational program on NCS-Based Medical expense management and Examination claim (의료정보시스템을 활용한 NCS 기반 진료비 관리 및 심사청구 교육프로그램 개발)

  • Choi, Joon-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.10
    • /
    • pp.1009-1016
    • /
    • 2016
  • In this study, an educational program was developed. The program can perform the claim for examination of medical expense, which is one of NCS Competence Unit Elements for hospital administration. Considering various coding to complex compute and process, VB.Net was employed for this development. For database, ACCESS Database was used because it is easy to learn and use. The learning effects by the developed program are expected to be as follows. First, the composition of medical expense can be understood by analyzing Medical history and then selecting insurance code according to the Standard of Medical Care Code. Second, unit cost per score can be learned according to hospital class. Third, selection of Column (medical materials) and Column II(medical practice) can classify items of additional ratio. Fourth, because patient's payment rate on hospitalization and meal expense and use of special equipment are differently applied, user can know patient's payment rate by type and can calculate it. Fifth, additional amount is the amount calculated by additional ratio of Column II(medical practice), and user can learn additional ratio according by insurance type and hospital class. Sixth, user can learn self-pay rate by hospital class and understand the process that self-pay amount and claim amount are calculated according by self-pay rate.