• Title/Summary/Keyword: Additional gas

Search Result 556, Processing Time 0.028 seconds

THE STUDY ON THE PROBLEMS OF MARITIME FACILITIES(GAS PLANT) INSURANCE REGULATIONS

  • Keun-Hyung Park;Moon-Sun Park ;Moon-Hwan Hwang;Yong-Su Kim
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1576-1581
    • /
    • 2009
  • The purpose of this study is to provide the problems of insurance system of maritime facilities(Gas Plant) in korea. In order to find out the problems of insurance system of construction work, the literature research and case study on the maritime facility construction are adopted as research method. And this study analyzed the construction cases of maritime facilities(Gas Plant) to which the national contract law was applied for the first time. The findings of this study are as follows: In the case analysis of 00 facility construction, the contractor pay additional insurance fees for the construction. And the regulations on insurance registration are not stated clearly relating to the enforcement ordinance of the national contract law.

  • PDF

Characteristics of Mercury Oxidation by an SCR Catalyst with Gas Composition (가스조성에 따른 선택적 환원촉매의 수은 산화 특성)

  • Lee, Sang-Sup;Kim, Kwang-Yul;Oh, Kwang-Joong;Jeon, Jun-Min;Kim, Do-Jeung;Kim, Ju-Yeong
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.125-132
    • /
    • 2012
  • Mercury oxidation in an SCR(selective catalytic reduction) catalyst was tested in this study with the conditions simulating the SCR system in full-scale coal-fired flue gas. A commercially available SCR catalyst was located in a temperature-controlled reactor system, and simulated gas was injected into the reactor. Mercury oxidation efficiency was determined from the difference between inlet and outlet elemental mercury concentrations. A control experiment was carried out with the gas composition of 12% $CO_{2}$, 5% $H_{2}O$, 5% $O_{2}$, 500 ppm $SO_{2}$, 400 ppm NO, 400 ppm $NH_{3}$, 5 ppm HCl, and 20 ${\mu}g/m^{3}$ Hg. Additional tests were conducted with different gas composition from the control condition to investigate the effect of gas composition on mercury oxidation in the SCR catalyst.

Neural Network Tuning of the 2-DOF PID Controller With a Combined 2-DOF Parameter For a Gas Turbine Generating Plant

  • Kim, Dong-Hwa
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.1 no.1
    • /
    • pp.95-103
    • /
    • 2001
  • The purpose of Introducing a combined cycle with gas turbine in power plants is to reduce losses of energy, by effectively using exhaust gases from the gas turbine to produce additional electricity or process. The efficiency of a combined power plant with the gas turbine increases, exceeding 50%, while the efficiency of traditional steam turbine plants is approximately 35% to 40%. Up to the present time, the PID controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain without any experience, since the gain of the PID controller has to be manually tuned by trial and error procedures. This paper focuses on the neural network tuning of the 2-DOF PID controller with a combined 2-DOF parameter (NN-Tuning 2-DOF PID controller), for optimal control of the Gun-san gas turbine generating plant in Seoul, Korea. In order to attain optimal control, transfer function and operating data from start-up, running, and stop procedures of the Gun-san gas turbine have been acquired and a designed controller has been applied to this system. The results of the NN-Tuning 2-DOF PID are compared with the PID controller and the conventional 2-DOF PID controller tuned by the Ziegler-Nichols method through experimentation. The experimental results of the NN-Tuning 2-DOF PID controller represent a more satisfactory response than those of the previously-mentioned two controllers.

  • PDF

Reduction of Thermal Radiation from Flare Stack by Flare Gas Recovery Unit (폐가스 회수장치를 이용한 플레어스택의 복사열 감소)

  • Lee, Heon-Seok;Lee, Dong-Heuk;Yoo, Jin-Hwan;Park, Chul-Hwan;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.1
    • /
    • pp.40-45
    • /
    • 2011
  • During process operations, overpressure can be caused by operator's error or malfunction of the device. To prevent this overpressure, gas was released through blowdown system. Because most of released gases are the hydrocarbon mixture and have flammable and toxic properties, the gas is released after burning in flare stack. The increase of scale and complexity of plant requires higher or additional flare stacks. This study tried to solve this problem through flare gas recovery system.

A Design and Application of the Ventilating and Heating System of T-103 Trainer Aircraft for Improvement (T-103 훈련기의 환기와 난방 시스템 개선에 관한 연구)

  • Jung, Daehan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.277-284
    • /
    • 2013
  • In this paper, the ventilating and heating system of T-103 trainer aircraft were investigated and redesigned to improve its poor performance. The ventilation system of the trainer was designed to increase the mass flow rate of fresh air by using air intake valves. The flow-in air through the air intake valve is supplied to the cabin by the ram effect of aircraft and the propeller. And the additional heating system was installed to improve the temperature of the cabin inside. The wasted heat from the exhaust gas of the engines was used as heat source of the additional heating system by installing an heat exchanger around the exhaust nozzle. The additional fresh air and the heated air enter the cabin via two ducts mounted under the instrument panel and behind the pedal in the cabin. The additional ventilating and heating system can be controlled by the first pilot and the secondary pilot individually using the control knob equipped separately. After mounting the additional ventilating and heating system, evaluations such as inspection of parts and component, ground run-up test, in-flight test, user test, etc. were conducted. The result of the tests was sufficient to meet the requirements of the manuals, and the pilots were satisfied with the additionally mounted systems.

Abnormal current-voltage characteristics of $SnO_2$ oxide semiconductor and their application to gas sensors ($SnO_2$ 산화물 반도체의 비정상적 전류 - 전압 특성과 가스센서로의 응용)

  • Lee Kyu-chung;Yoon Ho-Kun;Hur Chang-Wu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.7
    • /
    • pp.1436-1441
    • /
    • 2004
  • Abnormal current-voltage characteristics of an oxide semiconductor have been investigated and a novel method of detecting reducing gases utilizing self-heating mechanism of sensing layer without an additional heater has been developed. Planar-type sensors based on WO3-doped SnO2 were fabricated using a screen-printing technique. The applied voltage across the sensing layer caused heating of the sensing layer and the current abruptly varied upon exposure to a gas mostly as a result of surface reactions. A unique and fascinating aspect of the gas sensing scheme is that no additional heater is necessary for detection. The new sensing method has been applied to C2H5OH gas in this preliminary work.

Effects of Gas Injection on the Heating Performance of a Two-Stage Heat Pump Using a Twin Rotary Compressor with Refrigerant Charge Amount

  • Heo, Jae-Hyeok;Jeong, Min-Woo;Jeon, Jong-Ug;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.3
    • /
    • pp.77-82
    • /
    • 2008
  • For heat pumps used in a cold region, it is very important to obtain appropriate heating capacity. Several studies using a variable speed compressor and an additional heater have been performed to enhance heating capacity at low ambient temperatures. However, for outdoor temperature conditions below $-15^{\circ}C$, it is still difficult to obtain enough heating capacity above the rated value. In recent studies, the application of gas injection technique into a two-stage heat pump yielded noticeable heating performance improvement at low temperature conditions. In this study, the heating performance of a two-stage gas injection heat pump with a rated capacity of 3.5 kW was measured and analyzed by varying refrigerant charge amount and EEV opening at the standard heating condition. The heating performance of the two-stage gas injection heat pump was compared with that of a two-stage non-injection heat pump. The heating capacity and COP of the two-stage gas injection heat pump were improved by 2-10% at the optimal charging condition over those of the two-stage non-injection heat pump.

Flexible NO2 gas sensor using multilayer graphene films by chemical vapor deposition

  • Choi, HongKyw;Jeong, Hu Young;Lee, Dae-Sik;Choi, Choon-Gi;Choi, Sung-Yool
    • Carbon letters
    • /
    • v.14 no.3
    • /
    • pp.186-189
    • /
    • 2013
  • We report a highly sensitive $NO_2$ gas sensor based on multi-layer graphene (MLG) films synthesized by a chemical vapor deposition method on a microheater-embedded flexible substrate. The MLG could detect low-concentration $NO_2$ even at sub-ppm (<200 ppb) levels. It also exhibited a high resistance change of ~6% when it was exposed to 1 ppm $NO_2$ gas at room temperature for 1 min. The exceptionally high sensitivity could be attributed to the large number of $NO_2$ molecule adsorption sites on the MLG due to its a large surface area and various defect-sites, and to the high mobility of carriers transferred between the MLG films and the adsorbed gas molecules. Although desorption of the $NO_2$ molecules was slow, it could be enhanced by an additional annealing process using an embedded Au microheater. The outstanding mechanical flexibility of the graphene film ensures the stable sensing response of the device under extreme bending stress. Our large-scale and easily reproducible MLG films can provide a proof-of-concept for future flexible $NO_2$ gas sensor devices.

Estimation of Air Concentrations of PCBs using Passive Air Samplers (PAS) and a Gas/particle Partition Model (Passive Air Sampler (PAS)와 기체/입자 분배모델을 이용한 대기 중 PCB 농도 산정)

  • Baek, Song-Yee;Choi, Sung-Deuk;Chang, Yoon-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.734-743
    • /
    • 2007
  • Polyurethane foam-disk passive air samplers (PAS) were deployed in a southern area of Korea for three months. The target compounds were 12 coplanar polychlorinated biphenyls (PCBs). The congener profiles measured in this study were the same as those in ambient air and emission gas from the incinerator. A gradient of the total PCBs in different regions (industrial>residential>rural) was observed, suggesting the industrial complex may be an important source of coplanar PCBs. In general, only gas-phase compounds are mainly sequestrated by PAS. In order to estimate the concentration of particle-phase PCBs, a gas/particle partition model was used. A combined result (gas+particle-phase PCBs) was compared with previous results, indicating that the level of coplanar PCBs in our study area is comparable to those in other urban sites in the world. The validation of this method for estimating the total concentration is required through additional backup studies.

Economics of Self-Generation by Natural Gas Industry Using the Mixed Integer Program (혼합정수계획법을 이용한 천연가스(LNG) 산업의 자가발전소 건설에 대한 경제성 분석)

  • Lee, Jeong-Dong;Byun, Sang-Kyu;Kim, Tai-Yoo
    • IE interfaces
    • /
    • v.13 no.4
    • /
    • pp.658-667
    • /
    • 2000
  • Seasonal variation of natural gas demand coupled with rigid and stable import pattern of gas represents the characteristic feature of the Korean Liquified Natural Gas(LNG) industry. This attribute has required a huge amount of investment for the construction of storage facility. Thus, to minimize the supply cost, it is legitimate to reduce storage requirement itself. In this study, we combine three alternative methods to deal with the storage requirement to minimize the supply cost. Those are (1) adding additional storage tanks, (2) inducing large firm customers, and (3) constructing gas-turbine self generation facilities. Methodologically, we employ the mixed integer program (MIP) to optimize the system. The model also consider demand and price-setting scheme in separate modules. From the results, it is shown that if alternatives are combined optimally, a number of storage tanks can be reduced substantially compared with the original capacity plan set by the industry authorities. We perform various sensitivity analyses to check the robustness of the results. The methodology presented in this study can be applied to the other physical network industry, such as hydraulics. The empirical results will shed some light on the rationalization of capacity planning of the Korean natural gas industry.

  • PDF