• Title/Summary/Keyword: Additional Filters

Search Result 100, Processing Time 0.023 seconds

Centralized Kalman Filter with Adaptive Measurement Fusion: its Application to a GPS/SDINS Integration System with an Additional Sensor

  • Lee, Tae-Gyoo
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.4
    • /
    • pp.444-452
    • /
    • 2003
  • An integration system with multi-measurement sets can be realized via combined application of a centralized and federated Kalman filter. It is difficult for the centralized Kalman filter to remove a failed sensor in comparison with the federated Kalman filter. All varieties of Kalman filters monitor innovation sequence (residual) for detection and isolation of a failed sensor. The innovation sequence, which is selected as an indicator of real time estimation error plays an important role in adaptive mechanism design. In this study, the centralized Kalman filter with adaptive measurement fusion is introduced by means of innovation sequence. The objectives of adaptive measurement fusion are automatic isolation and recovery of some sensor failures as well as inherent monitoring capability. The proposed adaptive filter is applied to the GPS/SDINS integration system with an additional sensor. Simulation studies attest that the proposed adaptive scheme is effective for isolation and recovery of immediate sensor failures.

Half Wavelength Partial H-Plane Filter with Inverters having Attenuation Poles (감쇄극 인버터를 이용한 반파장 Partial H-Plane 여파기)

  • Kim, Dong-Jin;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.107-113
    • /
    • 2008
  • This paper presents half wavelength partial H-plane filters with multiple attenuation poles using narrow H-plane slot of evanescent waveguide. The narrow H-plane slot operates as an admittance inverter o( the bandpass filter and, simultaneously, generates an attenuation pole at particular frequency. Therefore, proposed filters with attenuation poles are simply implemented without any additional coupling and extra modification of the structure. The number of attenuation poles of the filters equals to that of the H-plane slots. Moreover, proposed filters are compact waveguide filter since ones are embodied by partial H-plane waveguide which has 1/4 cross section of conventional waveguide. The third and fourth-order half wavelength filters having 4 and 5 attenuation poles, respectively, are designed in H-band and their frequency responses are confirmed by simulation and measurement.

Area-Power Trade-Offs for Flexible Filtering in Green Radios

  • Michael, Navin;Moy, Christophe;Vinod, Achutavarrier Prasad;Palicot, Jacques
    • Journal of Communications and Networks
    • /
    • v.12 no.2
    • /
    • pp.158-167
    • /
    • 2010
  • The energy efficiency of wireless infrastructure and terminals has been drawing renewed attention of late, due to their significant environmental cost. Emerging green communication paradigms such as cognitive radios, are also imposing the additional requirement of flexibility. This dual requirement of energy efficiency and flexibility poses new design challenges for implementing radio functional blocks. This paper focuses on the area vs. power trade-offs for the type of channel filters that are required in the digital frontend of a flexible, energy-efficient radio. In traditional CMOS circuits, increased area was traded for reduced dynamic power consumption. With leakage power emerging as the dominant mode of power consumption in nanoscale CMOS, these trade-offs must be revisited due to the strong correlation between area and leakage power. The current work discusses how the increased timing slacks obtained by increasing the parallelism can be exploited for overall power reduction even in nanoscale circuits. In this context the paper introduces the notion of 'area efficiency' and a metric for evaluating it. The proposed metric has also been used to compare the area efficiencies of different classes of time-shared filters.

South Korean Study in a Public Health -Preventive Medicine and Sports Environment-

  • Radut, Dan Silviu;Kim, You-Jin;Min, Byung-Nam;Cho, Ki-Jeoung;Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.4
    • /
    • pp.209-214
    • /
    • 2009
  • Objectives : The aim of this study was to develop search filters able to retrieve the South Korean scientific output and relating the fields of public health, preventive medicine, and physical education, activity, fitness, exercise and sport in MEDLINE between 2000 and 2007. Methods : The search filters were constructed and applied in MEDLINE accessed through PubMed according to the affiliation and subject. The language and place of publication were identified and the evaluation of the geographical filter performance was done. Results : The search format was successfully elaborated and applied, and the articles originated, published in Korea and/or abroad focusing on the fields of public health, preventive medicine, physical education, activity, fitness, exercise and sport, added to MEDLINE between 2000 and 2007 were retrieved. Publications in six languages originated in South Korea were detected. Conclusions : A geographic search filter determined the South Korean research output, and combined with additional filters focused on specific areas. The dynamics of the scientific output followed an increased evolution in all categories. Articles were written mainly in English/Korean. Further research is recommended on developing search strategies in order to retrieve precise and reliable information.

A design of V-shape RE Equalizer using dielectric resonator (유전체 공진기를 이용한 대역 평탄도 개선용 V-shape RF Equalizer의 설계)

  • 신재완;정중성;황희용;김윤조;류재수;정승환;윤상원
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.132-135
    • /
    • 2002
  • A RF amplitude equalizer is designed to improve in-band flatness of Rf filters and/or systems using two dielectric resonators and a 90$^{\circ}$ hybrid. The equalizer has good return loss characteristics and V shaped S$_{21}$ response in passband which is suitable to compensate the ripple degradation due to insufficient quality factors of used resonators or narrow band width of filters or systems. After being connected to the equalizer, a 5-pole BPF at 1957MHz, which has 10 MHz bandwidth and 6㏈ ripple, shows only 1.8㏈ in-band ripple and good in- and out- band matched responses within used hybrid bandwidth without additional matching networks.

  • PDF

DEVELOPMENT OF A LARGE EDDY SIMULATION METHOD ON UNSTRUCTURED MESHES (비정렬 격자를 이용한 LES 기법 개발)

  • Lee, K.S.;Baek, J.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.106-109
    • /
    • 2006
  • A large eddy simulation with explicit filters on unstructured mesh is presented. Two explicit filters are adopted for reducing the aliasing error of the nonlinear convective term and measuring the level of subgrid scale velocity fluctuation, respectively. The developed subgrid scale model is basically eddy viscosity model which depends on the explicitly filtered fields and needs no additional ad hoc wall treatment such as van Driest damping function. As a validation problem, the flows around a sphere at several Reynolds numbers, including laminar and turbulent regimes, are calculated and compared to experimental data and numerical results in the literature.

  • PDF

A Method for Improving Stopband Characteristics of a Dual-Band Filter

  • Lee, Ja-Hyeon;Lim, Yeong-Seog
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.3
    • /
    • pp.186-191
    • /
    • 2011
  • This paper presents a simple and effective method for improving stopband rejection characteristics of previously studied dual-band filters. Small electric couplings were applied to the symmetrically positioned shunt resonators, which divided each transmission zero into two transmission zeros without any effect on passbands. We were able to achieve improved stopband rejection characteristics by these additional transmission zeros. For the filter application, we designed a dual-band filter with improved stopband characteristics using microstrip quasi-lumped elements. The electric couplings that control the location of transmission zeros are controlled by the distance between symmetric open stubs of the filter. The filter was fabricated with a relative dielectric constant of 3.5 and a thickness of 0.76 mm. The fabricated filter has a small size ($14.6{\times}13.2{\times}0.76$ mm) and a low insertion loss when compared with conventional filters.

A Subband Adaptive Blind Equalization Algorithm for FIR MIMO Systems (FIR MIMO 시스템을 위한 부밴드 적응 블라인드 등화 알고리즘)

  • Sohn, Sang-Wook;Lim, Young-Bin;Choi, Hun;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.476-483
    • /
    • 2010
  • If the data are pre-whitened, then gradient adaptive algorithms which are simpler than higher order statistics algorithms can be used in adaptive blind signal estimation. In this paper, we propose a blind subband affine projection algorithm for multiple-input multiple-output adaptive equalization in the blind environments. All of the adaptive filters in subband affine projection equalization are decomposed to polyphase components, and the coefficients of the decomposed adaptive sub-filters are updated by defining the multiple cost functions. An infinite impulse response filter bank is designed for the data pre-whitening. Pre-whitening procedure through subband filtering can speed up the convergence rate of the algorithm without additional computation. Simulation results are presented showing the proposed algorithm's convergence rate, blind equalization and blind signal separation performances.

A Novel Method for Bitrate Control within Macroblocks Using Kalman and FIR Filters

  • Seok, Jin-Wuk;Yoon, Ki-Song;Kim, Bum-Ho;Lee, Jeong-Woo
    • ETRI Journal
    • /
    • v.33 no.4
    • /
    • pp.641-644
    • /
    • 2011
  • In this letter, we propose a novel bitrate control, using both Kalman and FIR filters, based on a Hamiltonian analysis with respect to the amount of bits from each macroblock, in an encoding of a general video codec such as H.264/AVC. Since the proposed bitrate control is based on the simple computation of an optimal control method based on the Hamiltonian analysis, it is not necessary to use additional computation, such as a DCT or quantization, to estimate the bits for bitrate control. As a result, the proposed algorithm can be applied to single-pass encoding and can provide sufficient encoding speed with respect to various applications, even those requiring real-time control.

Study on Gonad Dose and Utility according to Use of Filters During the Defecography (배변조영촬영에 있어 필터사용에 따른 생식선량 및 유용성에 관한 연구)

  • Jung, Hong-Ryang;Kim, Ki-Jung;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.5
    • /
    • pp.206-213
    • /
    • 2009
  • The study is to measure a variation of exposed dose on genital glands (ovary, testis) which are exposed to radiation during the defecography to diagnosis domain according to use of filters and to look into its utility. whose results are as follows: The measured values of dose were the left ovary 23.4mGy, the right ovary 7.5mGy, the testis 10.3mGy in case of not using filter at all, the left ovary 22.4mGy the right ovary 7.0mGy, the testis 9.5mGy in case of using an additional filter only, the left ovary 26.7mGy, the right ovary 8.4mGy, the testis 11.5mGy in case of using a defeco filter only and the left ovary 20.5mGy, the right ovary 6.2mGy, the testis 7.5mGy in case of using both an additional filter and a defeco filter, respectively. When comparing with the value in case of not using filter at all, the dose to the left ovary decreased by 10%, the dose to right ovary by 5% and the testis by 8% respectively in case of using an additional filter only. While the dose to the left ovary increased by 33%, the dose to right ovary by 9% and the testis by 12% respectively gonad a defeco filter only. And in case of using both an additional filter and a defeco filter, the dose to the left ovary decreased by 29%, the dose to right ovary by 13% and the testis by 28% respectively. In other words, the dose increased in case of using a defeco filter only while the dose decreased markedly on the rest conditions such as using an additional filter only, using a defeco filter only and using both an additional filter and a defeco filter.