• Title/Summary/Keyword: Adaptive dc-link voltage

Search Result 17, Processing Time 0.019 seconds

Adaptive DC-link Voltage Control for Shunt Active Power Filter

  • Wang, Yu;Xie, Yun-Xiang
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.764-777
    • /
    • 2014
  • This study analyzes the mathematical relationship between DC-link voltage and system parameters for shunt active power filters (APFs). Analysis and mathematical deduction are used to determine the required minimum DC-link voltage for APF. A novel adaptive DC-link voltage controller for the three-phase four-wire shunt APF is then proposed. In this controller, the DC-link voltage reference value will be maintained at the required minimum voltage level. Therefore, power consumption and switching loss will effectively decrease. The DC-link voltage can also adaptively yield different DC-link voltage levels based on different harmonic currents and grid voltage levels and thus avoid the effects of harmonic current and grid voltage fluctuation on compensation performance. Finally, representative simulation and experimental results in a three-phase four-wire center-split shunt APF are presented to verify the validity and effectiveness of the minimum DC-link voltage design and the proposed adaptive DC-link voltage controller.

A New Approach for Constant DC Link Voltage in a Direct Drive Variable Speed Wind Energy Conversion System

  • Jeevajothi, R.;Devaraj, D.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.529-538
    • /
    • 2015
  • Due to the high efficiency and compact mechanical structure, direct drive variable speed generators are used for power conversion in wind turbines. The wind energy conversion system (WECS) considered in this paper consists of a permanent magnet synchronous generator (PMSG), uncontrolled rectifier, dc-dc boost converter controlled with maximum power point tracking (MPPT) and adaptive hysteresis controlled voltage source inverter (VSI). For high utilization of the converter's power capability and stabilizing voltage and power flow, constant DC-link voltage is essential. Step and search MPPT algorithm which senses the rectified voltage ($V_{DC}$) alone and controls the same is used to effectively maximize the output power. The adaptive hysteresis band current control is characterized by fast dynamic response and constant switching frequency. With MPPT and adaptive hysteresis band current control in VSI, the DC link voltage is maintained constant under variable wind speeds and transient grid currents respectively.

Novel Active Voltage Quality Regulator with Adaptive DC-Link Voltage Control

  • Xiao, Guochun;Zeng, Zhong;Liu, Kai;Hu, Zhiliang;Wang, Zhaoan
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.880-889
    • /
    • 2011
  • In this paper, a novel Active Voltage Quality Regulator (AVQR) topology with a thyristor rectifier and an adaptive dclink voltage control strategy are proposed. The proposed AVQR can efficiently mitigate the long duration variations (e.g. undervoltages/overvoltages), voltage imbalances and voltage harmonics. Compared with conventional AVQRs, it can regulate the load voltage very well with a much lower dc-link voltage. This is accomplished by replacing the diode rectifier with a thyristor rectifier. Moreover, its dc-link voltage can vary with the deviations of the supply voltage through the proposed adaptive dc-link voltage control strategy. All of these contribute to its significantly higher efficiency for online operating, which is very important and attractive for many applications. The proposed topology and control strategy are theoretically analyzed in detail. Simulation results are also provided in the paper. Finally, the feasibility and effectiveness of the proposed method are verified by means of experimental results from a 2kVA prototype. Both of the simulation and experimental results show that the proposed AVQR can achieve a much higher efficiency and similar regulation performance when compared with the conventional ones.

Instantaneous sinusoidal currant tracking mode inverter with quasi-resonant Link in DC side (공진 DC Link 순시 정현파 전류 추종형 인버터를 이용한 유도전동기 제어시스템)

  • Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.324-327
    • /
    • 1990
  • In this paper describes the feasibility study on a single-phase / three-phase voltage-fed inverter using 1GBTs, incorporating voltage-mode quasi-resonant DC Link and the instantaneous Sinusoidal Current tracking adaptive control implementation under zero voltage switching resfriction. The simulation and experimental results are shown here and discussed for single-phase voltage-fed and three-phase voltage-fed inverter in order to verify the new operating principle of the Inverter topology proposed here.

  • PDF

Adaptive Carrier-based PWM for a Four-Switch Three-Phase Inverter under DC-link Voltage Ripple Conditions

  • Nguyen, Tuyen D.;Lee, Hong-Hee;Nguyen, Hoang M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.290-298
    • /
    • 2010
  • This paper proposes an adaptive carrier-based pulse width modulation (PWM) method for a four-switch three-phase (4S3P) inverter under dc-link voltage ripple conditions. The proposed method guarantees balanced output currents despite of the existence of the voltage oscillations across two dc-link capacitors. And also, this new approach achieves a linear over-modulation with calculation time reduction. Simulation and experimental results are given to validate the feasibility of the proposed method.

An Adaptive Prefiltering Method for Reduction of DC-link ripple in Cascaded NPC/H-bridge System (Cascaded NPC/H-bridge 시스템의 DC-link 리플 저감을 위한 적응 선필터링 기법)

  • Lee, Hoon;Kang, Jin-Wook;Hyun, Seung-Wook;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.445-446
    • /
    • 2017
  • In this paper, adaptive prefiltering method is proposed for reduction of dc-link ripple in cascaded NPC/H-bridge system. Under non-linear load such as electric machine or harmonically distorted conditions, dc-link capacitor voltage with harmonics is inevitable result. In terms of reducing dc-link ripple, prefiltering method combined low pass filter with multiple second order generalized integrator is proposed. Proposed prefiltering method effectively reduces harmonics of dc-link ripple and improves characteristic of THD, simulated by using MATLAB R2014a and PSIM 9.1.4.

  • PDF

Sensor Fault Detection, Localization, and System Reconfiguration with a Sliding Mode Observer and Adaptive Threshold of PMSM

  • Abderrezak, Aibeche;Madjid, Kidouche
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1012-1024
    • /
    • 2016
  • This study deals with an on-line software fault detection, localization, and system reconfiguration method for electrical system drives composed of three-phase AC/DC/AC converters and three-phase permanent magnet synchronous machine (PMSM) drives. Current sensor failure (outage), speed/position sensor loss (disconnection), and damaged DC-link voltage sensor are considered faults. The occurrence of these faults in PMSM drive systems degrades system performance and affects the safety, maintenance, and service continuity of the electrical system drives. The proposed method is based on the monitoring signals of "abc" currents, DC-link voltage, and rotor speed/position using a measurement chain. The listed signals are analyzed and evaluated with the generated residuals and threshold values obtained from a Sliding Mode Current-Speed-DC-link Voltage Observer (SMCSVO) to acquire an on-line fault decision. The novelty of the method is the faults diagnosis algorithm that combines the use of SMCSVO and adaptive thresholds; thus, the number of false alarms is reduced, and the reliability and robustness of the fault detection system are guaranteed. Furthermore, the proposed algorithm's performance is experimentally analyzed and tested in real time using a dSPACE DS 1104 digital signal processor board.

Performance of an SiC-MOSFET Based 11-kW Bi-directional On-board Charger (SiC-MOSFET 기반 11-kW급 양방향 탑재형 충전기 성능)

  • Lee, Sang-Youn;Lee, Woo-Seok;Lee, Jun-Young;Lee, Il-Oun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.376-379
    • /
    • 2021
  • The design and performance of a SiC-MOSFET-based 11-kW bi-directional on-board charger (OBC) for electric vehicles is presented. The OBC consists of a three-phase two-level AC/DC converter and a CLLLC resonant converter. All the power devices are implemented with SiC-MOSFETs to reduce the conduction losses generated in the OBC, and the DC-link voltage is designed to track the level of battery voltage in the forward and reverse powering modes. As a result, the CLLLC resonant converter always runs at the switching frequency near the resonant frequency, resulting in high-efficiency operation at the maximum powering modes. As the DC-link voltage varies according to the battery voltage, the AC/DC converter in the proposed OBC adopts an adaptive DC-link voltage controller. The performance of the proposed 11-kW OBC is verified by a prototype converter with the following specifications: three-phase 60-Hz 380-V input, 11-kW capacity, and battery voltage range of 214-413-V, resulting in the conversion efficiency of over 95.0-% in the forward and reverse powering modes.

Adaptive Sliding Mode Observer for DC-Link Voltage Control of Switched Reluctance Generator without Position Sensor (적응 슬라이딩 모드 관측기를 이용한 Switched Reluctance Generator의 위치 센서 없는 구동에 관한 연구)

  • Choi, Yang-Kwang;Kim, Young-Seok;Kim, Young-Jo;Choi, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.179-182
    • /
    • 2002
  • The position information of the rotor are required while the SRG(Switched Reluctance Generator) is drived. The position information is generally provided by shaft encoder or resolver. But it is weak in the dusty, high temperator and EMI environment. Therefore, the sensor is able to required to eliminated from the SRG. In this paper, a estimation algorithm for the rotor position of the SRG is introducted and a constant DC-link voltage is controled by PID controller. The estimation algorithm is implemened by the adaptive sliding observer and that it is able to estimate the rotor position well is proved by the simulation.

  • PDF

Switch Open Fault Detection and Tolerant Operation Method for Three Phase PWM Rectifier (3상 PWM 정류기의 스위치 개방 고장 감지 및 허용운전 방법)

  • Shin, Hee-Keun;An, Byoung-Woong;Kim, Hag-Wone;Cho, Kwan-Yuhl;Jung, Shin-Myung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.266-273
    • /
    • 2012
  • In this paper, the new open fault detection and tolerant operation method for 3 phase PWM rectifier is proposed. When open fault occurred on the inverter switches of 3 Phase PWM rectifier, the DC link voltage ripple is increased because the input current of the faulty phase is distorted. In this case, the quality of electric power would decrease, and the life time of DC link capacitor is decreased. The open fault is detected by a simple MRAS(Model Reference Adaptive System) without additional hardware sensors, and the tolerant operation carried out by turning on the opposite switch of the faulty switch without any redundancy. By the proposed method, the faulty phase input current can be controlled, so that 3-phase input current is balanced relatively under the faulty condition and the voltage ripple of DC link output is reduced. The validity of the proposed technique is proved on the 6kW 3-phase PWM rectifier system by simulation and experiment.