• Title/Summary/Keyword: Adaptive Grid

Search Result 222, Processing Time 0.023 seconds

View-Dependent Adaptive Animation of Liquids

  • Kim, Jang-Hee;Ihm, In-Sung;Cha, Deuk-Hyun
    • ETRI Journal
    • /
    • v.28 no.6
    • /
    • pp.697-708
    • /
    • 2006
  • Various adaptive mesh refinement techniques are often employed in numerical simulations for increasing spatial and temporal resolution beyond the limits imposed by available CPU time and memory space. Recently, an octree-based adaptive mesh structure was successfully used in fluid animation to place more grid cells efficiently in visually interesting regions of fluids. In an attempt to optimize the use of computational resources further in fluid animation, this paper extends this adaptive technique by modifying the mesh refinement scheme so that the camera's viewing properties are dynamically exploited during the simulation. Based on a simple adaptive mesh structure, we show that the new meshing strategy can save a substantial amount of computation time and memory space by using a view-dependent adaptive approach. The experimental results reveal that the proposed technique provides a good compromise between the computational effort and the simulation's fidelity, and may be used quite effectively in 3D animation production.

  • PDF

Partition and Caching Mechanism for GML Visualization on Mobile Device (모바일 디바이스에서 GML 가시화를 위한 분할 및 캐싱 기법)

  • Song, Eun-Ha;Park, Yong-Jin;Han, Won-Hee;Jeong, Young-Sik
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.7
    • /
    • pp.1025-1034
    • /
    • 2008
  • In this paper, we developed GridGML for efficiently supplying a GML and visualizing the map with partitioning map and caching method to a mobile device. In order to overcome the weighting of a file, which is the biggest weakness of a GML, GridGML extracts only the most necessary parts for the visualization of the map among GML attributes, and makes the file light as a class instance by applying an offset value. GridGML manages a partition based on the visualization area of a mobile device to visualize the map to a mobile device in real time, and transmits the partition area by serializing it for the benefit of transmission. Also, the received partition area is compounded in a mobile device and is visualized by being partitioned again as four visible areas based on the display of a mobile device. Then, the area is managed by applying a caching algorithm in consideration of repetitiveness for a received map for the efficient operation of resources. Also, in order to prevent the delay in transmission time as regards the instance density area of the map, an adaptive map partition mechanism is proposed for maintaining the transmission time uniformly.

  • PDF

Type-2 Fuzzy Logic Predictive Control of a Grid Connected Wind Power Systems with Integrated Active Power Filter Capabilities

  • Hamouda, Noureddine;Benalla, Hocine;Hemsas, Kameleddine;Babes, Badreddine;Petzoldt, Jurgen;Ellinger, Thomas;Hamouda, Cherif
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1587-1599
    • /
    • 2017
  • This paper proposes a real-time implementation of an optimal operation of a double stage grid connected wind power system incorporating an active power filter (APF). The system is used to supply the nonlinear loads with harmonics and reactive power compensation. On the generator side, a new adaptive neuro fuzzy inference system (ANFIS) based maximum power point tracking (MPPT) control is proposed to track the maximum wind power point regardless of wind speed fluctuations. Whereas on the grid side, a modified predictive current control (PCC) algorithm is used to control the APF, and allow to ensure both compensating harmonic currents and injecting the generated power into the grid. Also a type 2 fuzzy logic controller is used to control the DC-link capacitor in order to improve the dynamic response of the APF, and to ensure a well-smoothed DC-Link capacitor voltage. The gained benefits from these proposed control algorithms are the main contribution in this work. The proposed control scheme is implemented on a small-scale wind energy conversion system (WECS) controlled by a dSPACE 1104 card. Experimental results show that the proposed T2FLC maintains the DC-Link capacitor voltage within the limit for injecting the power into the grid. In addition, the PCC of the APF guarantees a flexible settlement of real power exchanges from the WECS to the grid with a high power factor operation.

Decentralized Vehicle-to-Grid Design for Frequency Regulation within Price-based Operation

  • Kim, Seung Wan;Jin, Young Gyu;Song, Yong Hyun;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1335-1341
    • /
    • 2015
  • The utilization of electric vehicles has been suggested to support the frequency regulation of power system. Assuming that an intermediate aggregator exists, this study suggests a decentralized vehicle-to-grid operation scheme in which each vehicle-to-grid aggregator can behave independently of the power system operator. To implement this type of decentralized operation, this study adopts a price-based operation that has been proposed by many researches as an alternative operation scheme for the power system. In this environment, each vehicle-to-grid aggregator can determine its participation in vehicle-to-grid service in consideration of its residual energy of aggregated system and real-time market price. Consequently, the main purpose of this study is to verify whether or not the vehicle-to-grid power can effectively support the current frequency regulation function within the price-based operation scheme. Specifically, a frequency regulation method is proposed based on the real-time price signal, and a feedback controller for battery management is designed for decentralized vehicle-to-grid operation.

Triangular Grid Homogenization Using Local Improvement Method (국소개선기법을 이용한 삼각격자 균질화)

  • Choi, Hyung-Il;Jun, Sang-Wook;Lee, Dong-Ho;Lee, Do-Hyung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.8
    • /
    • pp.1-7
    • /
    • 2005
  • This paper proposes a local improvement method that combines extended topological clean up and optimization-based smoothing for homogenizing triangular grid system. First extended topological clean up procedures are applied to improve the connectivities of grid elements. Then, local optimization-based smoothing is performed for maximizing the distortion metric that measures grid quality. Using the local improvement strategy, we implement the grid homogenizations for two triangular grid examples. It is shown that the suggested algorithm improves the quality of the triangular grids to a great degree in an efficient manner and also can be easily applied to the remeshing algorithm in adaptive mesh refinement technique.

A Fast and Robust Grid Synchronization Algorithm of a Three-phase Converters under Unbalanced and Distorted Utility Voltages

  • Kim, Kwang-Seob;Hyun, Dong-Seok;Kim, Rae-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1101-1107
    • /
    • 2017
  • In this paper, a robust and fast grid synchronization method of a three-phase power converter is proposed. The amplitude and phase information of grid voltages are essential for power converters to be properly connected into the utility. The phase-lock-loop in synchronous reference frame has been widely adopted for the three-phase converter system since it shows a satisfactory performance under balanced grid voltages. However, power converters often operate under abnormal grid conditions, i.e. unbalanced by grid faults and frequency variations, and thus a proper active and reactive power control cannot be guaranteed. The proposed method adopts a second order generalized integrator in synchronous reference frame to detect positive sequence components under unbalanced grid voltages. The proposed method has a fast and robust performance due to its higher gain and frequency adaptive capability. Simulation and experimental results show the verification of the proposed synchronization algorithm and the effectiveness to detect positive sequence voltage.

Virtual Flux and Positive-Sequence Power Based Control of Grid-Interfaced Converters Against Unbalanced and Distorted Grid Conditions

  • Tao, Yukun;Tang, Wenhu
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1265-1274
    • /
    • 2018
  • This paper proposes a virtual flux (VF) and positive-sequence power based control strategy to improve the performance of grid-interfaced three-phase voltage source converters against unbalanced and distorted grid conditions. By using a second-order generalized integrator (SOGI) based VF observer, the proposed strategy achieves an AC voltage sensorless and grid frequency adaptive control. Aiming to realize a balanced sinusoidal line current operation, the fundamental positive-sequence component based instantaneous power is utilized as the control variable. Moreover, the fundamental negative-sequence VF feedforward and the harmonic attenuation ability of a sequence component generator are employed to further enhance the unbalance regulation ability and the harmonic tolerance of line currents, respectively. Finally, the proposed scheme is completed by combining the foregoing two elements with a predictive direct power control (PDPC). In order to verify the feasibility and validity of the proposed SOGI-VFPDPC, the scenarios of unbalanced voltage dip, higher harmonic distortion and grid frequency deviation are investigated in simulation and experimental studies. The corresponding results demonstrate that the proposed strategy ensures a balanced sinusoidal line current operation with excellent steady-state and transient behaviors under general grid conditions.

Maintenance Priority Index of Overhead Transmission Lines for Reliability Centered Approach

  • Heo, Jae-Haeng;Kim, Mun-Kyeom;Kim, Dam;Lyu, Jae-Kun;Kang, Yong-Cheol;Park, Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1248-1257
    • /
    • 2014
  • Overhead transmission lines are crucial components in power transmission systems. Well-designed maintenance strategy for overhead lines is required for power utilities to minimize operating costs, while improving the reliability of the power system. This paper presents a maintenance priority index (MPI) of overhead lines for a reliability centered approach. Proposed maintenance strategy is composed of a state index and importance indices, taking into account a transmission condition and importance in system reliability, respectively. The state index is used to determine the condition of overhead lines. On the other hand, the proposed importance indices indicate their criticality analysis in transmission system, by using a load effect index (LEI) and failure effect index (FEI). The proposed maintenance method using the MPI has been tested on an IEEE 9-bus system, and a numerical result demonstrates that our strategy is more cost effective than traditional maintenance strategies.

Input Voltage Sensorless Control for 3 Phase Vienna Rectifier (3상 비엔나 정류기 입력 전압 센서리스 제어)

  • Lee, Sang-Ri;Kim, Hag-Wone;Cho, Kwan-Yuhl;Hwang, Soon-Sang;Yoon, Byung-Chul
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.71-79
    • /
    • 2014
  • In this paper, a new grid voltage estimation algorithm without voltage sensors is proposed for the three-phase vienna rectifier. Generally, input voltage sensor circuits increase size and cost of the PWM rectifier In order to reduce the cost and size and in order to increase reliability from the electrical noise, grid voltage estimation scheme without input voltage sensor is highly required. In this paper, the grid voltage estimation algorithm is proposed by a simple MRAS(Model Reference Adaptive System) observer without input voltage sensors. The validity of the proposed method is proven by simulation and experiment on the three-phase vienna rectifier system.

An Adaptive Mobile System Through Grid Computing in Ubiquitous Environment (유비쿼터스 환경에서 그리드 컴퓨팅을 이용한 적응형 모바일 시스템)

  • Oh, Je-Hwan;Lee, Eun-Seok
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.1175-1181
    • /
    • 2006
  • 본 논문에서는 모바일 그리드 컴퓨팅 환경에서, 작업분배에 대한 보다 효율적인 계획을 스스로 결정하고, 이를 지속적으로 개선하는 'Self-Growing Engine' 기반 적응시스템을 제안한다. 최근, 모바일 컴퓨팅 환경에서의 다양한 제약사항을 극복하기 위해, 주변의 여러 컴퓨팅 단말기들의 유휴자원을 공유하여 하나의 작업을 처리하는 그리드 컴퓨팅 개념을 무선환경에 적용하려는 연구가 이슈로 등장하고 있다. 이때, 대부분의 기존 연구들은 그리드 컴퓨팅에 참여하는 단말기들의 리소스 상태만 고려하여 작업을 할당하는 방식을 취하고 있다. 따라서 상대적으로 작업효율이 낮은 단말기에서 작업이 할당되는 경우도 생기게 된다. 제안 시스템에서는 보다 효율적인 작업분배 결정을 위해, 다양한 사항을 고려하여 적절한 단말기를 선택하며, 각 작업수행결과를 history로 저장하며, 이후에 같은 요청이 있을 때 이를 분석하여 보다 적절한 단말기를 선택하도록 스스로 진화하는 특성을 갖는다. 우리는 제안 시스템의 평가를 위해, 데스크 탑에서 프로토타입을 구현하여 시뮬레이션을 수행하였으며, 그 결과를 통해 제안시스템의 효율성을 증명하였다.

  • PDF