• Title/Summary/Keyword: Actuator Limit

Search Result 75, Processing Time 0.03 seconds

Electromagnetic actuator design for the control of light structures

  • Der Hagopian, Johan;Mahfoud, Jarir
    • Smart Structures and Systems
    • /
    • v.6 no.1
    • /
    • pp.29-38
    • /
    • 2010
  • An ElectroMagnetic Actuator (EMA) is designed and assessed numerically and experimentally. The EMA has the advantage to be without contact with the structure so it could be applied to light and small mechanism. Nevertheless, the open-loop instability and the nonlinear dynamic behavior with respect to the excitation frequency could limit its application field. The EMA is designed and dimensioned as a function of the experimental structure to be controlled. An inverse model of the EMA is proposed in order to implement a linear action block for the used frequency range. The control strategy is a fuzzy controller with displacements and velocities as inputs. A fuzzy controller of Takagi-Sugeno type is used. The air gap is estimated by using a modal approximation of the displacements issued from all measurements. Several configurations of control are assessed by using numerical simulations. The block diagram used for numerical simulations is implemented under Dspace$^{(R)}$ environment. The implemented controller was tested experimentally in the context of impact perturbations. The results obtained show the effectiveness of the developed procedures and the robustness of the implemented control.

θz Stage Design and Control Evaluation for Wafer Hybrid Bonding Precision Alignment (Wafer Hybrid Bonding 정밀 정렬을 위한 θz 스테이지 설계 및 제어평가)

  • Mun, Jea Wook;Kim, Tae Ho;Jeong, Yeong Jin;Lee, Hak Jun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.4
    • /
    • pp.119-124
    • /
    • 2021
  • In a situation where Moore's law, which states that the performance of semiconductor integrated circuits doubles every two years, is showing a limit from a certain point, and it is difficult to increase the performance due to the limitations of exposure technology.In this study, a wafer hybrid method that can increase the degree of integration Various research on bonding technology is currently in progress. In this study, in order to achieve rotational precision between wafers in wafer hybrid bonding technology, modeling of θz alignment stage and VCM actuator modeling used for rotational alignment, magnetic field analysis and desgin, control, and evaluation are performed. The system of this study was controlled by VCM actuator, capactive sensor, and dspace, and the working range was ±7200 arcsec, and the in-position and resoultion were ±0.01 arcsec. The results of this study confirmed that safety and precise control are possible, and it is expected to be applied to the process to increase the integration.

Inertia Latch Design for Micro Optical Disk Drives (초소형 광리스크 드라이브용 관성 래치 설계)

  • 김유성;김경호;유승헌;김수경;이승엽
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.4
    • /
    • pp.287-294
    • /
    • 2004
  • Dynamic Load/unload (L/UL) mechanism is an alternative to the contact start stop (CSS) technology which eliminates striction and wear failure modes associated with CSS. Inertia latch mechanism becomes important for mobile disk drives because of non operating shock performance. Various types of latch designs have been introduced in hard disk drives to limit a rotary actuator from sudden uncontrolled motion. In this paper, a single spring inertia latch is introduced for a small form optical disk drive, which uses a rotary actuator for moving an optical pick-up. A new small inertia latch with sin91e spring is designed to ensure both feasible and small size. The shock performance of the new inertia latch is experimentally verified.

Study on Gravitational Torque Estimation and Compensation in Electrically Driven Satellite Antenna System (전기식으로 구동하는 위성안테나 시스템의 중력토크 추정 및 보상에 관한 연구)

  • Kim, Gwang Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.10
    • /
    • pp.789-796
    • /
    • 2016
  • The weight of an antenna system pointing satellite on the mobile platform is restricted by the weight limit of the mobile platform. The maximum power of the actuator driving the antenna system is thus limited because a high power actuator needs a heavier weight. Thus, a drive system is designed to have a low torque requirement by reducing the gravitational torque depending on gravity or acceleration of the mobile platform, including vibration, shock, and accelerated motion. To reduce the gravitational torque, the mathematical model of the gravitational torque is preferentially obtained. However, the method to directly estimate the mathematical model in an antenna system has not previously been reported. In this paper, a method is proposed to estimate the gravitational torque as a mathematical model in the antenna system. Additionally, a method is also proposed to calculate the optimal weight of the balancing weight to compensate for the gravitational torque.

Development of Human-Sized Biped Robot (인체형 이족 보행로봇의 개발)

  • 최형식;박용헌;이호식;김영식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.15-18
    • /
    • 2000
  • We developed a human-sized BWR(biped walking robot) driven by a new actuator based on the ball screw which has high strength and high gear ratio. The robot overcomes the limit of the driving torque of conventional BWRs. Each leg of the robot is composed of three pitch joints and one roll joint. In all, a 10 degree-of-freedom robot with two balancing joints was developed. The BWR was developed to walk autonomously such that it is actuated by small torque motors and is boarded with DC battery and controllers. In the performance test, the BWR performed nice motions of sitting-up and sitting-down. Through the test, we could find capability of high performance in biped-walking.

  • PDF

A study on Displacement-Load Calibration of Multi-Axis Simulator (다축 시뮬레이터의 변위-하중 보정에 관한 연구)

  • 정상화;류신호;신현성;김상석;박용래
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.591-594
    • /
    • 2000
  • In the recent day, fatigue life prediction techniques play a major role in the design of components in the ground vehicle industry. Full scale durability testing in the laboratory is an essential of any fatigue life evaluation of components or structure of the automotive vehicle. Component testing is particulary important in today's highly competitive industries where the design to reduce weight and production costs must be balanced with the necessity to avoid expensive service failure. Generally, 3-axis durability testing device is used to carry out the fatigue test. In this paper, The operation software for simultaneously driving 3-axis vibration testing device is developed and the displacement of the 3-axis actuator is separately calibrated by LDT Moreover, the input and output data are displayed in windows of PC controller with real time.

  • PDF

Development of Human-Sized Biped Robot (인체형 이족 보행로봇의 개발)

  • 최형식;박용헌;이호식;김영식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.267-267
    • /
    • 2000
  • We developed a human-sized BWR(biped walking robot) driven by a new actuator based on the ball screw which has high strength and high gear ratio. The robot overcomes the limit of the driving torque of conventional BWRs. Each leg of the robot is composed of three pitch joints and one roll joint. In all, a 10 degree-of-freedom robot with two balancing joints was developed. The BWR was developed to walk autonomously such that it is actuated by small torque motors and is boarded with DC battery and controllers. In the performance test, the BWR peformed nice motions of sitting-up and sitting-down. Through the test, we could find capability of high performance in biped-walking.

  • PDF

Active Vibration Control Method Using Frequency Controllable Piezoelectric Transducer (주파수가변 압전 트랜스듀서를 이용한 능동제진법)

  • Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol;Kang, Sung-Hak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.1E
    • /
    • pp.27-32
    • /
    • 2007
  • Hydraulic actuator and electro-magnetic liner actuator have been used as typical active vibration control methods. However these methods have many kinds of disadvantages such as causing space limit, difficult maintenance, complicate structures, etc. The purpose of this paper was to study on the possibility of active vibration control using piezoelectric transducer. Piezoelectric transducer generated a vibration and GIC (General Impedance Converter) amplifier was adopted to give adjustable vibration signal to transducer and high amplitude of vibration. Resonance frequency of piezoelectric transducer was controlled by GIC amplifier and higher amplitude of vibration was achieved. Finally active vibration control using piezoelectric transducer was performed.

Intelligent Phase Plane Switching Control of Pneumatic Artificial Muscle Manipulators with Magneto-Rheological Brake

  • Thanh, Tu Diep Cong;Ahn, Kyoung-Kwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1983-1989
    • /
    • 2005
  • Industrial robots are powerful, extremely accurate multi-jointed systems, but they are heavy and highly rigid because of their mechanical structure and motorization. Therefore, sharing the robot working space with its environment is problematic. A novel pneumatic artificial muscle actuator (PAM actuator) has been regarded during the recent decades as an interesting alternative to hydraulic and electric actuators. Its main advantages are high strength and high power/weight ratio, low cost, compactness, ease of maintenance, cleanliness, readily available and cheap power source, inherent safety and mobility assistance to humans performing tasks. The PAM is undoubtedly the most promising artificial muscle for the actuation of new types of industrial robots such as Rubber Actuator and PAM manipulators. However, some limitations still exist, such as the air compressibility and the lack of damping ability of the actuator bring the dynamic delay of the pressure response and cause the oscillatory motion. In addition, the nonlinearities in the PAM manipulator still limit the controllability. Therefore, it is not easy to realize motion with high accuracy and high speed and with respect to various external inertia loads in order to realize a human-friendly therapy robot To overcome these problems a novel controller, which harmonizes a phase plane switching control method with conventional PID controller and the adaptabilities of neural network, is newly proposed. In order to realize satisfactory control performance a variable damper - Magneto-Rheological Brake (MRB) is equipped to the joint of the manipulator. Superb mixture of conventional PID controller and a phase plane switching control using neural network brings us a novel controller. This proposed controller is appropriate for a kind of plants with nonlinearity uncertainties and disturbances. The experiments were carried out in practical PAM manipulator and the effectiveness of the proposed control algorithm was demonstrated through experiments, which had proved that the stability of the manipulator can be improved greatly in a high gain control by using MRB with phase plane switching control using neural network and without regard for the changes of external inertia loads.

  • PDF

A Development of Measurement System for Diathesis-Diagnosis (체질 진단용 센서 시스템의 구현)

  • 정용래;김승우
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.117-120
    • /
    • 2002
  • This paper is to develop the sensing system for opening-force measurement such as O-Ring muscular meridian. We designed to overcome the functional limit that the conventional force-sensor can measure just the closing-force. Therefore, the new sensor can meet a variety of application as well as O-Ring test. The structure of the new sensor is an actuator-type system using an electromagnet. That is made up of mechanical system, electromagnet, current transformer and computer interface circuit. Driving software and user interface program of the new sensor system also is explained in this paper.

  • PDF