• 제목/요약/키워드: Actual Test

검색결과 3,534건 처리시간 0.029초

20대 여성을 위한 재킷패턴 개발에 관한 연구 (A Study of the Development of Jacket Patterns for Women in Their 20's)

  • 신장희
    • 한국의상디자인학회지
    • /
    • 제16권3호
    • /
    • pp.1-13
    • /
    • 2014
  • This study investigated body type among women in their 20s and the development of prototypes for tailored jackets by body type in order to design clothes in consideration of an imbalance in body type caused by the popularity of portable devices such as smartphones and Netbooks. This study aims to create a design of jacket patterns by body type through both actual and virtual wear testing among women in their 20s, who are the major consumer of ready-made clothes and are very sensitive to size fit. This study will provide pattern information for the manufacture of jackets with a goal of securing the latest scientific body type information and establish the grounds for a research method in the manufacture of clothes. According to actual and virtual wear tests of four different body types, a significant difference was found in armhole circumference in most types because it was scanned with the arms slightly apart to prevent the armhole area from being missed during the 3D scanning. This has resulted in a slight distortion in measurements. To correct this problem, it is necessary to verify the precision of the body scanner and its program. In categories in which a large significant difference was found, it is necessary to test them against many subjects. In addition, it would be required to perform a further study on the 3D virtual wear system, which could be useful in the clothing industry.

  • PDF

Multi-Secondary Transformer: A Modeling Technique for Simulation - II

  • Patel, A.;Singh, N.P.;Gupta, L.N.;Raval, B.;Oza, K.;Thakar, A.;Parmar, D.;Dhola, H.;Dave, R.;Gupta, V.;Gajjar, S.;Patel, P.J.;Baruah, U.K.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.78-82
    • /
    • 2014
  • Power Transformers with more than one secondary winding are not uncommon in industrial applications. But new classes of applications where very large number of independent secondaries are used are becoming popular in controlled converters for medium and high voltage applications. Cascade H-bridge medium voltage drives and Pulse Step Modulation (PSM) based high voltage power supplies are such applications. Regulated high voltage power supplies (Fig. 1) with 35-100 kV, 5-10 MW output range with very fast dynamics (${\mu}S$ order) uses such transformers. Such power supplies are widely used in fusion research. Here series connection of isolated voltage sources with conventional switching semiconductor devices is achieved by large number of separate transformers or by single unit of multi-secondary transformer. Naturally, a transformer having numbers of secondary windings (~40) on single core is the preferred solution due to space and cost considerations. For design and simulation analysis of such a power supply, the model of a multi-secondary transformer poses special problem to any circuit analysis software as many simulation softwares provide transformer models with limited number (3-6) of secondary windings. Multi-Secondary transformer models with 3 different schemes are available. A comparison of test results from a practical Multi-secondary transformer with a simulation model using magnetic component is found to describe the behavior closer to observed test results. Earlier models assumed magnetising inductance in a linear loss less core model although in actual it is saturable core made-up of CRGO steel laminations. This article discusses a more detailed representation of flux coupled magnetic model with saturable core properties to simulate actual transformers very close to its observed parameters in test and actual usage.

교육 현장에서 시행된 임상 술기 시험의 다면적 타당도 분석 (Multifaceted validity analysis of clinical skills test in the educational field setting)

  • 채한;이민정;김명호;김규석;조은별
    • 대한한의학회지
    • /
    • 제45권1호
    • /
    • pp.1-16
    • /
    • 2024
  • Introduction: The importance of clinical skills training in traditional Korean medicine education is increasingly emphasized. Since the clinical skills tests are high-stakes tests that determine success in national licensing exams, it is essential to develop reliable multifaceted analysis methods for clinical skills tests in actual education settings. In this study, we applied the multifaceted validity evaluation methods to the evaluation results of the cardiopulmonary resuscitation module to confirm the applicability and effectiveness of the methods. Methods: In this study, we used internal consistency, factor analysis, generalizability theory G-study and D-study, ANOVA, Kendall's tau, descriptive statistics, and other statistical methods to analyze the multidimensional validity of a cardiopulmonary resuscitation test in clinical education settings over the past three years. Results: The factor analysis and internal consistency analysis showed that the evaluation rubric had an unstable structure and low concordance. The G-study showed that the error of the clinical skills assessment was large due to the evaluator and unexpected errors. The D-study showed that the variance error of the evaluator should be significantly reduced to validate the evaluation. The ANOVA and Kendall's tau confirmed that evaluator heterogeneity was a problem. Discussion and Conclusion: Clinical skills tests should be continuously evaluated and managed for validity in two steps of pre-production and actual implementation. This study has presented specific methods for analyzing the validity of clinical skills training and testing in actual education settings. This study would contribute to the foundation for competency-based evidence-based education in practical clinical training.

파력발전 시스템 쓰러스트 베어링의 스마트 모니터링을 위한 이상 및 고장 운용 재현 방법에 관한 연구 (A Study on the Abnormal and Fault Reproduction Method for Smart Monitoring of Thrust Bearing in Wave Power Generation System)

  • 오재원;민천홍;성기영;강관구;노현정;김태욱;조수길
    • 한국산업융합학회 논문집
    • /
    • 제23권5호
    • /
    • pp.835-842
    • /
    • 2020
  • This paper considers a method of reproducing abnormal and fault operation for smart monitoring of thrust bearing used in wave power generation system. In order to develop smart monitoring technology, abnormal and failure data of actual equipment are required. However, it is impossible to artificially break down the actual equipment in operation due to safety and cost. To tackle this problem, a test bed that can secure data through reproduction of a faulty operating environment should be developed. Therefore, in this study, test bed that can reproduce each situation was developed and the operation result was analysis after identifying the situation to be reproduced through the failure factor analysis of the thrust bearing.

Compressibility behaviour of peat reinforced with precast stabilized peat columns and FEM analysis

  • Kalantari, Behzad;Rezazade, Reza K.
    • Geomechanics and Engineering
    • /
    • 제9권4호
    • /
    • pp.415-426
    • /
    • 2015
  • Researches have been done to discover ways to strengthen peat soil deposits. In this model study, fibrous peat that is the most compressible types of peat has been reinforced with precast peat columns stabilized with ordinary Portland cement and polypropylene fibres. Rowe cell consolidation tests as well as plate load tests (PLTs) were conducted on various types of test samples to evaluate the strength and deformation of untreated peat and peat reinforced by various types of columns. PLTs were conducted in a specially designed and fabricated circular steel test tank. The compression index ($C_c$) and recompression index ($C_r$) of fibrous peat samples reduced considerably upon use of precast columns. Also, PLT results confirmed the results obtained from Rowe cell tests. Use of polypropylene fibres added to cement further decreased ($C_c$) and ($C_r$) and increased load bearing capacity of untreated peat. Finite element method (FEM) using Plaxis 3D was carried out to evaluate the stress distributions along various types of tested samples and also, to compare the deformations obtained from FEM analysis with the actual maximum deformations found from PLTs. FEM results indicate that most of the induced stresses are taken on the upper portion of tested samples and reach their maximum values below the loading plate. Also, a close agreement was found between actual deformation values obtained from PLTs and values resulted from FEM analysis for various types of tested samples.

차륜형장갑차용 유압펌프의 해석 및 시험을 통한 신뢰성 확보에 관한 연구 (A Study on Ensuring Reliability of Hydraulic Pumps for Wheeled Armored Vehicles through Analysis and Testing)

  • 김원재;이호준;최청석;서석호;최성웅
    • 한국기계가공학회지
    • /
    • 제19권9호
    • /
    • pp.78-84
    • /
    • 2020
  • This paper introduces the structural and vibration analysis performed in the localization development process of hydraulic pumps used in wheeled armored vehicles. The maximum strain, maximum stress, maximum displacement, and minimum safety factor were calculated using structural analysis. Furthermore, it was found that the dangerous resonance frequency was avoided through vibration analysis. In addition, the reliability of the analysis results was verified by passing various tests, such as the actual vibration test and the actual durability test. The developed hydraulic pump is expected to contribute significantly to the maintenance of military vehicles in the future.

석탄화력발전소 보일러 연료제어 알고리즘과 분산제어시스템의 개발 (The Development of Boiler Fuel Control Algorithm and Distributed Control System for Coal-Fired Power Plant)

  • 임건표;이흥호
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.36-44
    • /
    • 2013
  • This paper is written for the development and application of boiler fuel control algorithm and distributed control system of coal-fired power plant by the steps of design, coding, simulation test, site installation and site commissioning test. Fuel control algorithm has the upper algorithm and it is boiler master control algorithm that controls the fuel, feed water, air by generation output demand. Generation output demand by power load influences fuel control. Because fuel can not be supplied fast to the furnace of boiler, fuel control algorithm was designed adequately to control the steam temperature and to prevent the explosion of boiler. This control algorithms were coded to the control programs of distributed control systems which were developed domestically for the first time. Simulator for coal-fired power plant was used in the test step. After all of distributed control systems were connected to the simulator, the tests of the actual power plant were performed successfully. The reliability was obtained enough to be installed at the actual power plant and all of distributed control systems had been installed at power plant and all signals were connected mutually. Tests for reliability and safety of plant operation were completed successfully and power plant is being operated commercially. It is expected that the project result will contribute to the safe operation of domestic new and retrofit power plants, the self-reliance of coal-fired power plant control technique and overseas business for power plant.

석탄화력발전소 보일러 노내압력 제어알고리즘과 분산제어시스템의 개발 (The Development of Boiler Furnace Pressure Control Algorithm and Distributed Control System for Coal-Fired Power Plant)

  • 임건표;허광범;박두용;이흥호
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.117-126
    • /
    • 2013
  • This paper is written for the development and application of boiler furnace pressure control algorithm and distributed control system of coal-fired power plant by the steps of design, coding, simulation test, site installation and site commissioning test. The control algorithms were designed in the shape of cascade control for two parts of furnace pressure control and induced draft fan pitch blade by standard function blocks. This control algorithms were coded to the control programs of distributed control systems. The simulator for coal-fired power plant was used in the test step and automatic control, sequence control and emergency stop tests were performed successfully like the tests of the actual power plant. The reliability was obtained enough to be installed at the actual power plant and all of distributed control systems had been installed at power plant and all signals were connected mutually. Tests for reliability and safety of plant operation were completed successfully and power plant is being operated commercially. It is expected that the project result will contribute to the safe operation of domestic new and retrofit power plants, the self-reliance of coal-fired power plant control technique and overseas business for power plant.

사무공간의 사용자 행위별 형광램프와 LED조명 감성비교 실험에 관한 연구 (A Study on the Comparison of the Emotional Experiment from Fluorescent Lamp and LED Lighting)

  • 이민진
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.8-17
    • /
    • 2012
  • Unlike traditional lightings, LED lighting is one of objects that sends user an emotional segments through brightness control from various color temperature and dimming control. Also, within present interior lighting environment, emotional researches about traditional fluorescent lamp and newly implemented LED lighting environment are in active progress. Despite the fact adjectives describing emotions and scale modeling have been repeatedly used in many cases for a long time, there seems to be a lack of results in reliability, and there is a limitation for applying into actual lighting design. The purpose of this study is to construct an actual sized test-bed, which is used to draw out one's emotional words of behavior patterns from inner emotional experiences about lighting environment in an office space. Also, having fluorescent lamp and LED lighting as the main test subjects, we have tested emotional parts according to the changes of color temperature and adjective vocabularies chosen from user's action, and we have compared and analyzed the drawn out data. Also, having fluorescent lamp and LED lighting as the main test subjects, we have tested emotional parts according to the changes of color temperature and adjective vocabularies chosen from user's action, and we have compared and analyzed the drawn out data.

상대습도 100% 환경에 노출된 콘크리트의 시간 의존적 거동 (Time-dependent Behaviors of Concrete Exposed in the 100% Relative Humidity)

  • 민경환;김율희;정형철;윤영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.693-696
    • /
    • 2008
  • 실제 FCM 교량에 적용되는 고강도 콘크리트의 시간의 다양한 양생 환경에서의 시간 의존적 거동을 평가하기 위해, 기건 및 도포, 습윤 환경에서의 100${\times}$100${\times}$400mm 각주형 공시체의 수축량을 측정하였다. 또한 상수와 10% CaCl$_2$ 수용액에 노출된 콘크리트의 3일 및 28일 재령에서의 압축크리프를 측정하였고, 일반적인 기건 및 도포 공시체의 실험 결과와 비교하였다. 도포와 습윤 양생 환경에 노출된 콘크리트의 시간 의존적 거동은 건조수축과 크리프 모두 상당한 차이를 보였다. 따라서 기존의 크리프 실험 방법으로 실제 콘크리트 구조물의 크리프와 건조수축을 측정하는 것에 대한 재고가 필요하다고 판단된다.

  • PDF