• 제목/요약/키워드: Actual State of operation

검색결과 161건 처리시간 0.03초

계통운영시스템 계통해석 프로그램 정확도 향상에 관한 연구 (A Study on the Enhancement of Accuracy of Network Analysis Applications in Energy Management Systems)

  • 조윤성
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.88-96
    • /
    • 2015
  • This paper describes a new method for enhancing the accuracy of network analysis applications in energy management systems. Topology processing, state estimation, power flow analysis, and contingency analysis play a key factor in the stable and reliable operation of power systems. In this respect, the aim of topology processing is to provide the electrical buses and the electrical islands with the actual state of the power system as input data. The results of topology processing is used to input of other applications. New method, which includes the topology error analysis based on inconsistency check, coherency check, bus mismatch check, and outaged device check is proposed to enhance the accuracy of network analysis. The proposed methodology is conducted by energy management systems and the Korean power systems have been utilized for the test systems.

Steady-State Harmonic Domain Matrix-Based Modeling of Four-Quadrant EMU Line Converter

  • Wang, Hui;Wu, Mingli;Agelidis, Vassilios G.;Song, Kejian
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.572-579
    • /
    • 2014
  • As a non-linear time variant system, the four-quadrant line converter of an electric multiple unit (EMU) was expressed by linear time periodic functions near an operating point and modeled by a steady-state harmonic domain matrix. The components were then combined according to the circuit connection and relations of the feedback control loops to form a complete converter model. The proposed modeling method allows the study of the amplitude of harmonic impedances to explore harmonic coupling. Moreover, the proposed method helps provide a better design for the converter controllers, as well as solves the problem in coordination operation between the EMUs and the AC supply. On-site data from an actual $CRH_2$ high-speed train were used to validate the modeling principles presented in the paper.

Coordinated Droop Control for Stand-alone DC Micro-grid

  • Kim, Hyun-Jun;Lee, Yoon-Seok;Kim, Jae-Hyuk;Han, Byung-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1072-1079
    • /
    • 2014
  • This paper introduces a coordinated droop control for the stand-alone DC micro-grid, which is composed of photo-voltaic generator, wind power generator, engine generator, and battery storage with SOC (state of charge) management system. The operation of stand-alone DC micro-grid with the coordinated droop control was analyzed with computer simulation. Based on simulation results, a hardware simulator was built and tested to analyze the performance of proposed system. The developed simulation model and hardware simulator can be utilized to design the actual stand-alone DC micro-grid and to analyze its performance. The coordinated droop control can improve the reliability and efficiency of the stand-alone DC micro-grid.

자기부상 시스템의 PID 제어와 Feedback Linearization 제어와의 성능비교 (Comparison of PID and Feedback Linearization Control for Magnetic Levitation System)

  • 박종석;김동환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.263-263
    • /
    • 2000
  • Electromagnetic Suspension(EMS) System produces no noise, friction and heat through non-contacting operation Therefore, the applicable device using EMS system has a lot of attraction in case of the high-speed and non-contacting transmission EMS with nonlinear properties requires a precise airgap position control and stable kinematics characteristics under the disturbances, In this study, the nonlinear system was linearized by a Nonlinear Feedback Lineariztion(NFL) method. The NFL method requires that the modelling should be exact, and the state variables should be measured and a rapidly operating controller be necessary on account of a heavy data calculating In the experiments. the ideal control characteristics of the NFL was acquired through simulation at first. then the characteristics of the actual system were compared with those of simulation. In addition, the results by NFL were examined and analysed considering the characteristics of the PID control. The Control by NFL shows much stable control characteristics than the PID control. Whereas, the steady state errors occur for various disturbances. hence a robust control design is remained for a further study.

  • PDF

Tailoring Operations based on Relational Algebra for XES-based Workflow Event Logs

  • Yun, Jaeyoung;Ahn, Hyun;Kim, Kwanghoon Pio
    • 인터넷정보학회논문지
    • /
    • 제20권6호
    • /
    • pp.21-28
    • /
    • 2019
  • Process mining is state-of-the-art technology in the workflow field. Recently, process mining becomes more important because of the fact that it shows the status of the actual behavior of the workflow model. However, as the process mining get focused and developed, the material of the process mining - workflow event log - also grows fast. Thus, the process mining algorithms cannot operate with some data because it is too large. To solve this problem, there should be a lightweight process mining algorithm, or the event log must be divided and processed partly. In this paper, we suggest a set of operations that control and edit XES based event logs for process mining. They are designed based on relational algebra, which is used in database management systems. We designed three operations for tailoring XES event logs. Select operation is an operation that gets specific attributes and excludes others. Thus, the output file has the same structure and contents of the original file, but each element has only the attributes user selected. Union operation makes two input XES files into one XES file. Two input files must be from the same process. As a result, the contents of the two files are integrated into one file. The final operation is a slice. It divides anXES file into several files by the number of traces. We will show the design methods and details below.

Lessons Learned from Energy Storage System Demonstrations for Primary Frequency Control

  • Yu, Kwang-myung;Choi, In-kyu;Woo, Joo-hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권2호
    • /
    • pp.107-114
    • /
    • 2018
  • In recent years, ESS (Energy Storage System) has been widely used in various parts of a power system. Especially, due to its fast response time and high ramp rate, ESS is known to play an important role in regulating grid frequency and providing rotational inertia. As the number of installed and commercially operating ESSs increases, the reliability becomes an important issue. This paper introduces control schemes and presents its test method for grid-connected ESS for primary frequency regulation. The test method allows to verify the control operation in the individual operation mode and state. A validation of the method through actual ESS test in a electrical substation is presented in the case study section.

중부지방에서의 로터리 경운작업 실태조사 및 경운부하 (Research on the Actual Condition of Rotary Tilling & Rotary Power Requirement in the Central Area)

  • 명병수;이현동
    • 한국산업융합학회 논문집
    • /
    • 제12권2호
    • /
    • pp.79-83
    • /
    • 2009
  • In this study, actual state of operation of rotary tillage was surveyed in the central part of Korea which includes 29 rural community around Asan city, Choongnam principal. 29 heads of the village and 44 farmers were surveyed at the field with a questionnaire on the operation of rotary tillage with farm tractors. Power requirement of rotary tillage operation was measured at the field of each farmers during rotary tilling operation in the central part of Korea. Summaries of this study are summarized as follows. 1) Operations of tillage and land preparation were found to be carried out with farm tractors by 98 percents which are results of the survey on 29 heads of the village and 44 farmers. 2) More than half of the farms had tractors with horsepower more than 38 kW which states that most tractors were supplied in middle and large size. 3) The case of applying secondary tillage after the first primary tillage were 79 percent among the most of operations of tillage and field preparation. Rotary tillage were carried out on the most of wet paddy fields and only 14 percent of dry fields were cultivated with rotary tillage. 4) 63.6 percent of farm tractors were surveyed to meet the recommended field capacity on tillage operation by the government which were ranged from 15.1 to 34.9 ha. And the field capacity of these farm tractors were greater than that of annual total area of operation field, 13.2ha (data from Information of agricultural machinery, National agricultural products quality service, Korea), which states the utilization of agricultural machinery was high in the area surveyed. 5) 46 percent of farmers changed the blade of rotary implement when they used it over the field capacity of rotary blade of 33 ha which is the area of field for rotary operation per a blade change. 55 percent of farmers changed the rotary blade more than once per two years. 6) The required power for rotary operation of each farm tractors were measured as 17.206 kW at untilled paddy field and 34.989 kW at untilled dry field on the average, respectively. The required power for rotary operation was measured as 28.248 kW on the average at the paddy field which had been plowed once and 28.015 at the paddy field that had rotary tillage operation. Untilled dry field showed the highest value of the required power for rotary operation.

  • PDF

음식물류폐기물 공공 자원화시설 운영에 관한 연구 (I) - 운영현황과 문제점을 중심으로 - (Study on the Public Food Waste Recycling Facility Operation (I) - Focusing on the Current State of Operation and the Problems -)

  • 홍용표;김혜선;김웅용;신현곤
    • 유기물자원화
    • /
    • 제24권1호
    • /
    • pp.41-49
    • /
    • 2016
  • 본 연구는 음식물류 폐기물 공공 자원화 시설 운영의 문제점과 제도 개선방안을 위하여 실시하였다. 기존 음식물류 폐기물 공공자원화 시설에 대한 실태조사를 통해 운영에 따른 문제를 분석하였으며, 이를 위하여 음식물류 폐기물의 발생량 및 자원화 현황, 공공 및 민간 자원화시설 현황, 전국의 주요 음식물류 폐기물 공공 자원화 시설의 실제 운영과정에서 나타난 문제점을 분석한 결과는 다음과 같다: 현재 국내 음식물류 폐기물의 분리 수거량은 약 97%인 것으로 나타났다. 그리고 대부분의 공공 자원화시설은 음식물류 폐기물의 자원화가 아닌 단순처리에 급급한 것으로 나타났으며 경제성도 없는 것으로 분석되었다. 특히, 바이오가스시설 대부분은 실시설계와는 달리 가스 생산량 및 수요량이 전혀 맞지 않는 것으로 나타났다.

호환성 및 속도 향상을 위한 FPGA 기반 DDR 메모리 인터페이스의 최적화 (Optimization of FPGA-based DDR Memory Interface for better Compatibility and Speed)

  • 김대운;강봉순
    • 한국정보통신학회논문지
    • /
    • 제25권12호
    • /
    • pp.1914-1919
    • /
    • 2021
  • 첨단산업의 발전에 따라 영상처리 하드웨어의 연구는 필수적이고, 실제 칩 동작을 위해서는 게이트 수준의 타이밍 검증이 필요하다. 이를 위해 주로 FPGA 기반 검증이 이루어지는데 기존에는 DDR3 메모리 인터페이스를 적용했지만, 최근에는 FPGA 스펙이 향상되면서 DDR4 메모리가 사용된다. 이 때 기존에 사용하던 메모리 인터페이스를 적용하면 CPU와 메모리의 성능 차이에 의한 신호들의 타이밍 불일치가 발생하기 때문에 사용할 수 없다. 본 논문에서는 기존 인터페이스 시스템 FSM의 State 최적화를 통해 문제를 해결하고, 이 과정에서 AXI Data Width 수정을 통해 데이터 읽기 속도를 2배 증가시킨다. 실제 사례 분석을 위해 Xilinx 사의 SoC보드 중 DDR3 메모리를 사용하는 ZC706과 DDR4 메모리를 사용하는 ZCU106을 사용한다.

Power Cable Ampacity and Influential Factors Analysis under Operation

  • Tong, Qiang;Qi, Jianping;Wang, Yanling;Liang, Likai;Meng, Xiangxing;Zhang, Qiang
    • Journal of Information Processing Systems
    • /
    • 제14권5호
    • /
    • pp.1136-1149
    • /
    • 2018
  • With the increasing of urban electricity demand, making the most use of the power cable carrying capacity has become an important task in power grid system. Contrary to the rated ampacity obtained under extremely conservative conditions, this paper presents the various steady value of cable ampacity by using the changing surrounding parameters under operation, which is based on cable ampacity calculation equation under the IEC-60287 standard. To some degree, the cable ampacity analysis of actual surroundings improves the transmission capacity of cables. This paper reveals the factors that influence cable ampacity such as insulating layer thickness, allowable long-term conductor temperature, the ambient temperature, soil thermal resistance coefficient, and so on, then gives the class of the influence of these parameters on the ampacity, which plays a great role in accurately calculating the real-time ampacity and improving the utilization rate of cable in the complex external environment condition. Furthermore, the transient thermal rating of the cable is analyzed in this paper, and temperature variation of the conductor under different overload conditions is discussed, which provides effective information for the operation and control of the system.