• Title/Summary/Keyword: Activity monitoring system

Search Result 377, Processing Time 0.034 seconds

Glove Type Heart Rate Monitoring System Using Blood Flow Change (혈류량 변화를 이용한 장갑형 심박수 모니터링 시스템)

  • Han, Yun-Cheol;Noh, Yun-Hong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.503-504
    • /
    • 2017
  • Recently, economic growth in the world has increased interest in healthy life, and the smart health care industry is growing. In the field of smart healthcare, wearable-type biometric information measurement technology has been highlighted due to the importance of IoT technology. The purpose of this study is to develop a wearable heart - rate monitoring system that can be applied to wearable health care and glove - type monitoring that enables convenient monitoring of heart rate during activity. For this purpose, a glove - type wearable health care system was developed and its performance was evaluated. Experimental results showed that the heartbeat monitoring was possible even in the presence of actual daily activities.

  • PDF

Case Study: Long-term Experiments on a Daily Activity Monitoring System for an Elderly Living Alone (사례 연구: 녹거노인 일상 활동 모니터링 시스템의 실제 주택에서의 장기간 실험)

  • Lee, Seon-Woo;Ok, Dae-Yoon;Jung, Phil-Hwan;Kim, Jeom-Keun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.8
    • /
    • pp.738-743
    • /
    • 2012
  • This paper describes analysis of long-term experiments on a monitoring system to assess the daily activities of the elderly who live alone. The developed system is composed of an in-house sensing system and a server system. The in-house sensing system installed in their own houses is a typical wireless sensor network system including three kinds of wireless sensors. The server system has a database server and an assessment server. We have installed the system into an elderly house, collected data during over two years continuously, then analyze the data. From the analysis, we could measure the energy consumption profile of three kinds of sensor nodes. The experiment shows all kinds of nodes can operate over one year with two AA-size alkaline batteries. Using a measure of reliability of the monitoring system called 'deadzone', the system has showed the failure operation for 842 hours (4.66 %) during over 18,000 hours total operation period.

An ECG Monitoring and Analysis Method for Ubiquitous Healthcare System in WSN

  • Bhardwaj, Sachin;Lee, Dae-Seok;Chung, Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.1
    • /
    • pp.7-11
    • /
    • 2007
  • The aim of this paper is to design and implement a new ECG signal monitoring and analysis method for the home care of elderly persons or patients, using wireless sensor network (WSN) technology. The wireless technology for home-care purpose gives new possibilities for monitoring of vital parameter with wearable biomedical sensors and will give the patient freedom to be mobile and still be under continuously monitoring. Developed platform for portable real-time analysis of ECG signals can be used as an advanced diagnosis and alarming system. The ECG features are used to detect life-threatening arrhythmias, with an emphasis on the software for analyzing the P-wave, QRS complex, and T-wave in ECG signals at server after receiving data from base station. Based on abnormal ECG activity, the server transfer diagnostic results and alarm conditions to a doctor's PDA. Doctor can diagnose the patients who have survived from arrhythmia diseases.

Low-power wireless communication System for Biosignal transmission (생체신호 무선 송수신을 위한 소형,저전력 통신시스템 개발)

  • Lee, Kang-Hwi;Lee, Jeong-Whan;Kim, Kyeong-Seop;Kim, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.370-372
    • /
    • 2005
  • Inconveniences which might arise in transmitting measured biological data based on cable protocols generally are recognized critical points in tele-monitoring environment and also restrict the mobility of the user. a. Especially, activity monitoring which is importantly recognized as a core parameter in ubiquitous healthcare arena and weight management, pervasive and wireless measuring technology is most needed. In this paper, we would like to suggest lower power, miniaturized communication system in order to solve the above problems. The suggested system is powered by small coin-size battery. Also, The suggested system is compared with a blue-tooth module which is generally available in the commercial market. Even though, the suggested system didn't have higher transmission rate, its low power consumption make the suggested system would be feasible in ubiquitous monitoring of biological signals in ubiquitous healthcare arena.

  • PDF

Smart Toothbrush System Development Using Auto Tooth brushing Position Detection (자동 위치 검출을 이용한 지능형 칫솔 시스템 개발)

  • Lee, Kang-Hwi;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Kim, Dong-Jun;Yun, Tae-Ho;Yang, Heui-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1908-1909
    • /
    • 2007
  • The design of an intelligent toothbrush, capable of monitoring brushing motion, orientation through the grip axis, during toothbrushing is described. Inappropriate Toothbrushing styles, even in adults, sometimes cause dental problems, cavities, gingivitis, etc. This smart system provides user to monitor his or her brushing pattern using accelerometer and magnetic sensors for evaluation of toothbrushing style. Directional information of toothbrush with respect to earth's magnetic field and activity data were measured by a miniaturized low-power micro- controller, MSP430 and transmitted to personal computer by 2.4GHz radio transmitter, nRF2401. A personal computer provides an on-line display of activity and orientation measurements during toothbrushing. The signal trace is then analyzed to extract clinically relevant measurement. This preliminary study showed that the proposed monitoring system was conceived to aid dental care personnel in patient education and instruction in oral hygiene regarding brushing style.

  • PDF

Analyzing Dog Health Status through Its Own Behavioral Activities

  • Karimov, Botirjon;Muminov, Azamjon;Buriboev, Abror;Lee, Cheol-Won;Jeon, Heung Seok
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.263-266
    • /
    • 2019
  • In this paper, we suggest an activity and health monitoring system to observe the status of the dogs in real time. We also propose a k-days algorithm which helps monitoring pet health status using classified activity data from a machine learning approach. One of the best machine learning algorithm is used for the classification activity of dogs. Dog health status is acquired by comparing current activity calculation with passed k-days activities average. It is considered as a good, warning and bad health status for differences between current and k-days summarized moving average (SMA) > 30, SMA between 30 and 50, and SMA < 50, respectively.

  • PDF

Environmental Monitoring Using Comfort Sensing System

  • Na, Dae-Suk;Kang, Jeong-Ho;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.24-33
    • /
    • 2003
  • This research is about a comfort sensing system for human environmental monitoring using a one-bodied humidity and temperature sensor and an air flow sensor. The thermal comfort that a human being feels in indoor environment has been known to be influenced mostly by six parameters, i.e. air temperature, radiation, air flow, humidity, activity level and clothing thermal resistance. Considering an environmental monitoring, we have designed and fabricated a one-bodied humidity and temperature sensor and an air flow sensor that detect air relative humidity, temperature and air flow in human environment using surface micromachining technologies. Micro-controller calculates a PMV (predicted mean vote) and CSV (comfort sensing vote) with sensing signals and display a PMV on LCD (liquid crystal display) for human comfort on indoor climate. Our work has demonstrated that a comfort sensing system can provide an effective means of measuring and monitoring the indoor comfort sensing index of a human being. Experimental results with simulated environment clearly suggest that our comfort sensing system can be used in many applications such as air conditioning system, feedback controlling in automobile, home and hospital etc..

Development of Engine Vibration Analysis and Monitoring System(EVAMOS) for Marine Vessels (선박용 엔진 진동 분석 및 모니터링 시스템(EVAMOS) 개발에 관하여)

  • Lee, D.C.;Joo, K.S.;Nam, T.K.;Kim, E.S.;Kim, S.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.155-161
    • /
    • 2009
  • Engine builders have separately developed and applied torsional, axial and structural vibration monitoring system on most marine engines. These systems displayed their results for engine or ship operation engineers and were not regularly stored at the hardware of computer. So, the history and trend of various engine and hull vibrations were not supported for preventive maintenance and to protect the failure of these activity or function. The integrated vibration or stress monitoring system(EVAMOS : engine vibration analysis and monitoring system) in marine diesel engine, its accessories and hull structure have been developed by the dynamics laboratory of Mokpo Maritime University during last 3 years. This paper introduces the design conception and ability of commercial software EVAMOS with field data on several actual tests.

A Study on the Development of the Web-based Monitoring System for the Wind Turbine Powers (웹 기반 풍력발전 모니터링 시스템 개발에 관한 연구)

  • Kim, In-Su;Kim, Sung-Sik;Choi, Young-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1147-1148
    • /
    • 2006
  • The increase of exhaust gas which is caused by with the industry activity which follows in the Industrial Revolution of the human being has had an influence on the globe climate system so that causes the problem of the greenhouse effect. As a comprehensive countermeasures, it has been prompted to save energy, build a structure environmentally friendly and use renewable energy sources that are continually replenished by nature-the sun, the wind, the Earth's heat, and plants. In addition, new technologies that turn these fuels into usable forms of energy-most often electricity, but also heat, chemicals or mechanical power have been applied actively to the social infrastructure. Therefore, there should be methods to manage forms of renewable energy effectively and securely. This paper proposes the web-based monitoring system for the wind power system of these methods and introduces the real web-based monitoring system installed in Daegwallyeong.

  • PDF

Evaluation of Minimum Detectable Activity for Underwater Radiation Monitoring System (수중 방사선 모니터링 시스템의 성능평가를 위한 수중 내 최소검출가능농도 산출)

  • Jangguen Park;Sung-Hee Jung;Daemin Oh;Jinho Moon
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.219-224
    • /
    • 2023
  • A high-efficiency underwater radiation monitoring system, HydroGamma, has been developed for detecting 137Cs and 131I in the event of waterborne radiation contamination. The system consists of a 3-inch NaI (Tl) detector, solar panels for power supply, data acquisition and transmission modules, and batteries. HydroGamma also includes a 40K calibration source for remote performance evaluation and energy calibration. In this study, some simulations and experiments were carried out to evaluate the minimum detectable activities (MDA) of HydroGamma. We installed the HydroGamma at Tapjeongho Lake in Nonsan-si and acquired background data since MDA is calculated based on the experimental background data. The results show that the minimum detectable activities for 137Cs and 131I were 1.78Bq L-1 and 1.81Bq L-1, respectively even though the gamma rays emitted from 40K(1,460 keV) affect the minimum detectable activities for them.