• Title/Summary/Keyword: ActiveX

Search Result 1,430, Processing Time 0.028 seconds

Research of Active Transponder application as Ground Control Point in Synthetic Aperture Radar Images (SAR 영상 내에서 능동 트랜스폰더의 GCP 활용 여부에 관한 연구)

  • Jeong, Ho-Ryung;Oh, Tae-Bong;Park, Duk-Jong;Lee, Sun-Gu;Lim, Hyo-Suk
    • Aerospace Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.164-170
    • /
    • 2012
  • This paper presents that the comparison results of AT (Active Transponder) positions obtained from different measurements: the result of GPS device and evaluated position from the SAR (Synthetic Aperture Radar) image, and active transponders can be useful as GCPs(Ground Control Points) in SAR images. The X-band AT are installed on the wide-and-flat area to improve SCR(signal-to-clutter ration), and activated to represent impulse response function in order to operate as one point target in SAR images. Cosmo-SkyMed operating at X-band frequency are used to provide SAR images of AT. The comparison of AT position is performed by using the result of GPS device field measurement and AT SAR images. ENVI-SARscape S/W is used to evaluate AT position in the SAR images. From the comparison, it is shown that AT are useful as GCPs for SAR images.

A single sensor based active reflection control system using FxLMS algorithm (FxLMS를 이용한 단일 센서기반 능동 반향음 제어 시스템)

  • Kim, Jaepil;Ji, Youna;Park, Young cheol;Seo, Young soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.1
    • /
    • pp.57-63
    • /
    • 2017
  • This paper presents an active acoustic-reflection control algorithm based on a single sensor. The proposed algorithm operates in a system comprising a single sensor located nearby the reflective surface and a control transducer mounted on the reflective surface. First, the incident and reflected acoustic signals are separated from the sensor signal, and a control signal is generated using the separated signals. For the signal separation, the proposed algorithm requires the response of the reflection path which is estimated from the acoustic response between an external sound source and the sensor. Finally, the control filter is adjusted using the FxLMS (Filtered-x Least Mean Square) algorithm. To verify the effectiveness of the proposed algorithm, it was implemented in real time using a DSP (Digital Signal Processing) board, and the experimental results obtained in one-dimensional air-acoustic environment show that the reflections of the 1 kHz burst can be reduced by 11.6 dB.

Experimental investigation on effect of ion cyclotron resonance heating on density fluctuation in SOL at EAST

  • Li, Y.C.;Li, M.H.;Wang, M.;Liu, L.;Zhang, X.J.;Qin, C.M.;Wang, Y.F.;Wu, C.B.;Liu, L.N.;Xu, J.C.;Ding, B.J.;Lin, X.D.;Shan, J.F.;Liu, F.K.;Zhao, Y.P.;Zhang, T.;Gao, X.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.207-219
    • /
    • 2022
  • The suppression of high-intensity blob structures in the scrape-off layer (SOL) by ion-cyclotron range of frequencies (ICRF) power, leading to a decrease in the turbulent fluctuation level, is observed first in the Experimental Advanced Superconducting Tokamak (EAST) experiment. This suppression effect from ICRF power injection is global in the whole SOL at EAST, i.e. blob structures both in the regions that are magnetically connected to the active ICRF launcher and in the regions that are not connected to the active ICRF launcher could be suppressed by ICRF power. However, more ICRF power is required to reach the full blob structure suppression effect in the regions that are magnetically unconnected to the active launcher than in the regions that are magnetically connected to the active launcher. Studies show that a possible reason for the blob suppression could be the enhanced Er × B shear flow in the SOL, which is supported by the shaper radial gradient in the floating potential profiles sensed by the divertor probe arrays with increasing ICRF power. The local RF wave power unabsorbed by the core plasma is responsible for the modification of potential profiles in the SOL regions.

A Design and Implementation of MathML-based Math Equation Generating Website (MathML에 기반한 수학식 생성 웹사이트의 설계 및 구현)

  • Park, Jeong-Hee;Lee, Mee-Jeong
    • The Journal of Korean Association of Computer Education
    • /
    • v.6 no.3
    • /
    • pp.173-183
    • /
    • 2003
  • E-learning education methodology using the web has been as much activated with the introduction of the internet to our society. As for the web-based education, there is no exception in case of mathematics. However, when it comes to representing math equations by using HTML image tags, a type of web marked-up language, it can be hard to represent math equations that have structural features, and to do the search, resulting in the difficulty in reusing math related applications. Therefore, based on MathML and using ActiveX control technology, a math equation generating website was designed and implemented in this study. Since this system employed ActiveX control technology, it is possible to generate math equations without the limit of time and place on the web, and to manage the program with the most up-to-dale version. And in this system, it is also possible to save the math equations generated in this system to be referred to for their reuse in the future.

  • PDF

T/R Module Development for X-Band Active Phased-Array Radar (능동 위상 배열 레이더용 X-대역 T/R 모듈 개발)

  • Kim, Dong-Yoon;Chong, Min-Kil;Kim, Sang-Keun;Chon, Sang-Mi;Na, Hyung-Gi;Baik, Seung-Hun;Ahn, Chang-Soo;Kim, Seon-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1243-1251
    • /
    • 2009
  • This paper presents design and test results of X-Band Transmit/Receive(T/R) module for active phased-array radar. Active phased array radars typically require solid state T/R modules with high output power, low noise figure, high Third Order Intercept(TOI), and sufficient gain in both transmit and receive. The output power of the module is 9 watts over a wide bandwidth. The noise figure is as low as 2.8 dB. Phase and amplitude are controlled by the 6-bit phase shifter and 5-bit attenuator, respectively. Highly integrated T/R module is achieved by using LTCC(Low Temperature Co-fired Ceramic) multiple layer substrate. The module incorporates a compact digital interface, requires only three supply voltages.

Clinical Characteristics and Diagnosis of Laryngeal Tuberculosis (후두결핵의 임상양상과 진단)

  • Cho, Hyun-Jin;So, Yoon-Kyoung;Son, Young-Ik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.19 no.1
    • /
    • pp.43-46
    • /
    • 2008
  • Background and Objectives : Clinical suspicion and appropriate diagnostic procedures are essential for the timely management of extrapulmonary type of mycobacterial disease. In the hope of suggesting a suitable guideline for the early diagnosis of laryngeal tuberculosis, the authors reviewed their clinical pathways and the characteristics of patients with laryngeal tuberculosis who were managed in the recent 10 years at a single tertiary referral hospital, Samsung Medical Center. Subjects and Method : Retrospective chart review was performed for the 25 adult patients with laryngeal tuberculosis. Among 25 cases, 12 were pathologically confirmed by laryngeal biopsy and the other 13 were clinically diagnosed by cumulative clinical information; definite laryngitis on laryngoscopy, positive AFB (acid fast bacillus) smear/culture or active pulmonary tuberculosis on chest X-ray, and substantial response to anti-tuberculosis medication. Results : Chest X-ray revealed active pulmonary tuberculosis in 72% of patients (N=18/25). Sputum AFB smear/culture was positive in 95% of all tested patients (N=21/22) and in 100% of the tested patients who have stable or no evidence of pulmonary tuberculosis (N=5/5). All patients except one who had coexisting laryngeal malignancy showed considerable improvement in their subjective symptoms and laryngeal findings within the first 2 months of anti-tuberculosis medications and they achieved complete response on subsequent sputum studies, chest X-ray and laryngeal findings after $7.0{\pm}2.3$ months of the medications. Conclusion : We suggest that chest X-ray and sputum AFB smear/culture to be the first step of work-up for the patients having laryngeal tuberculosis in suspicion since laryngeal tuberculosis is largely associated with active pulmonary tuberculosis and/or sputum AFB study offers high yield even in case of primary laryngeal tuberculosis. However laryngeal biopsy must be considered in case showing unsatisfactory response to the anti-tuberculosis medication for more than 2 months.

  • PDF

Active ITS Infrastructure Management Strategy for Enhanced ITS Service (기존 ITS 서비스의 성능 강화를 위한 능동형 ITS 인프라 관리 전략)

  • Choi, Dongwon
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.45-53
    • /
    • 2014
  • In this study, we analyzed the next generation ITS (C-ITS) technology trends, focusing on the national and international C-ITS projects. Based on the promotion practices of developed countries, we pointed out the lack of linkages with the existing ITS infrastructure. As a way to overcome this problem, we proposed the three-direction to enable the existing ITS infrastructure corresponding to the C-ITS. First one is developing a technique to improve the performance of the existing ITS infrastructure and automate the performance management (Performance-enhanced ITS). Second, developing active sensors or fusion sensor which along with V2X communication technology implement of an active safety driving support system (Safety-enhanced ITS). Third, we need to develop a technology that generate the new advanced traffic data by integrating the collected data from existing ITS infrastructure and nomadic device (Cloud-ITS). By improving the function of the existing ITS infrastructure for adaptation to the new V2X communication environment, we enhanced the efficiency of maintenance performance and would maximize the benefit of the introduction of C-ITS.

On the development of an empirical proton event forecast model based on the information of flares and CMEs

  • Moon, Yong-Jae;Park, Jin-Hye
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.38.2-38.2
    • /
    • 2010
  • We have examined the occurrence probability of solar proton events (SPEs) and their peak fluxes depending three flare parameters (X-ray peak flux, longitude, and impulsive time). For this we used NOAA SPEs from 1976 to 2006, and their associated X-ray flare data. As a result, we selected 166 proton events that were associated with major flares; 85 events associated with X-class flares and 81 events associated with M-class flares. Especially the occurrence probability strongly depends on these three parameters. In addition, the relationship between X-ray flare peak flux and proton peak flux as well as its correlation coefficient are strongly dependent on longitude and impulsive time. Among NOAA SPEs from 1997 to 2006, most of the events are related to both flares and CMEs but a few fraction of events (5/93) are only related with CMEs. We carefully identified the sources of these events using LASCO CME catalog and SOHO MDI data. Specifically, we examined the directions of CMEs related with the events and the history of active regions. As a result, we were able to determine active regions which are likely to produce SPEs without ambiguity as well as their longitudes at the time of SPEs by considering solar rotation rate. From this study, we found that the longitudes of five active regions are all between $90^{\circ}W$ and $120^{\circ}W$. When the flare peak time is assume to be the CME event time, we confirmed that the dependence of their rise times (proton peak time - flare peak time) on longitude are consistent with the previous empirical formula. These results imply that five events should be also associated with flares which were not observed because they occurred from back-side. Now we are examining the occurrence probability of SPEs depending on CME parameters. Finally, we will discuss the future prospects on the development of an empirical SPE forecast model based on the information of flares and CMEs.

  • PDF

A Study on the Active Vibration Control of Flexible Beam Using Filtered-X LMS Algorithm (Filtered-X LMS 알고리즘을 이용한 유연한 보의 능동진동 제어)

  • 홍진석;손동구;박수홍;오재웅
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.402-407
    • /
    • 1994
  • 유연한 구조물의 진동문제에 대해 Filtered-X LMS 알고리즘을 이용한 제어계를 구성하고 디지탈 신호처리보드를 이용하여 실시간 제어를 수행하였다. 엑추에이터는 피에조 세라믹을 사용하였고 정현파 및 잡색잡음 가진 형태의 외란을 가하였다. 실험결과 1차 고유주파수에서 7dB 이상의 진동저감을 할 수 있었으며 관심 주파수영역 내에서 진동이 고르게 저감되었다.

  • PDF

Transmit-Beam Pattern Measurement of the Active Phased-Array Antenna Using Near-Field Measurement Facility (근접 전계 시험 시설을 이용한 능동 위상 배열 안테나 송신 빔 패턴 측정)

  • Chae, Hee-Duck;Kim, Han-Saeng;Lee, Dong-Kook;Jeong, Myung-Deuk;Park, Jong-Kuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1155-1164
    • /
    • 2011
  • In this paper, we proposed the transmit beam measurement method of active phased array antenna, which is installed in Korea's first developed naval medium range radar, using near-field measurement facility. The pulse-mode high power characteristics of active phased array antenna's trasmit-beam make it difficult to measure with general near-field measurement facilities where low power continuous RF signals are used. Thus, in this paper, the measurement method of active phased array antenna's transmit beam in conjunction with the near-field measurement facility, which is suitable for the high-power transmit beam measurement, and PNA-X network analyzer(Agilent Technologies), which can support pulse-mode measurement, was proposed and measured by near-field measurement techniques. And the EIRP(Effective Isotropic Radiated Power), the transmit characteristic of active phased array antenna, was measured by the near field measurement techniques and compared to numerical estimation which was nearly equal with small difference of 0.1 dB.