• 제목/요약/키워드: Active-Bypass

검색결과 31건 처리시간 0.023초

A Highly Efficient Dual-Mode 3G/4G Linear CMOS Stacked-FET Power Amplifier Using Active-Bypass

  • Kim, Unha;Kim, Yong-Gwan;Woo, Jung-Lin;Park, Sunghwan;Kwon, Youngwoo
    • Journal of electromagnetic engineering and science
    • /
    • 제14권4호
    • /
    • pp.393-398
    • /
    • 2014
  • A highly efficient dual-mode linear CMOS stacked-FET power amplifier (PA) is implemented for 3G UMTS and 4G LTE handset applications. High efficiency is achieved at a backed-off output power ($P_{out}$) below 12 dBm by employing an active-bypass amplifier, which consumes very low quiescent current and has high load-impedance. The output paths between high- and low-power modes of the PA are effectively isolated by using a bypass switch, thus no RF performance degradation occurs at high-power mode operation. The fabricated 900 MHz CMOS PA using a silicon-on-insulator (SOI) CMOS process operates with an idle current of 5.5 mA and shows power-added efficiency (PAE) of 20.5%/43.5% at $P_{out}$ = 12.4 / 28.2 dBm while maintaining an adjacent channel leakage ratio (ACLR) better than -39 dBc, using the 3GPP uplink W-CDMA signal. The PA also exhibits PAE of 35.1% and $ACLR_{E-UTRA}$ of -33 dBc at $P_{out}$ = 26.5 dBm, using the 20 MHz bandwidth 16-QAM LTE signal.

Comparison Study on Power Output Characteristics of Power Management Methods for a Hybrid-electric UAV with Solar Cell/Fuel Cell/Battery

  • Lee, Bohwa;Kwon, Sejin
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제17권4호
    • /
    • pp.631-640
    • /
    • 2016
  • A dual-mode power management for a hybrid-electric UAV with a cruise power of 200W is proposed and empirically verified. The subject vehicle is a low-speed long-endurance UAV powered by a solar cell, a fuel cell, and a battery pack, which operate in the same voltage bounds. These power sources of different operational characteristics can be managed in two different methods: passive management and active management. This study proposes a new power management system named PMS2, which employs a bypass circuit to control the individual power sources. The PMS2 normally operates in active mode, and the bypass circuit converts the system into passive mode when necessary. The output characteristics of the hybrid system with the PMS2 are investigated under simulated failures in the power sources and the conversion of the power management methods. The investigation also provides quantitative comparisons of efficiencies of the system under the two distinct power management modes. In the case of the solar cell, the efficiency difference between the active and the passive management is shown to be 0.34% when the SOC of the battery is between 25-65%. However, if the SOC is out of this given range, i.e. when the SOC is at 90%, using active management displays an improved efficiency of 6.9%. In the case of the fuel cell, the efficiency of 55% is shown for both active and passive managements, indicating negligible differences.

Low-Power Cool Bypass Switch for Hot Spot Prevention in Photovoltaic Panels

  • Pennisi, Salvatore;Pulvirenti, Francesco;Scala, Amedeo La
    • ETRI Journal
    • /
    • 제33권6호
    • /
    • pp.880-886
    • /
    • 2011
  • With the introduction of high-current 8-inch solar cells, conventional Schottky bypass diodes, usually adopted in photovoltaic (PV) panels to prevent the hot spot phenomenon, are becoming ineffective as they cause relatively high voltage drops with associated undue power consumption. In this paper, we present the architecture of an active circuit that reduces the aforementioned power dissipation by profitably replacing the bypass diode through a power MOS switch with its embedded driving circuitry. Experimental prototypes were fabricated and tested, showing that the proposed solution allows a reduction of the power dissipation by more than 70% compared to conventional Schottky diodes. The whole circuit does not require a dedicated DC power and is fully compatible with standard CMOS technologies. This enables its integration, even directly on the panel, thereby opening new scenarios for next generation PV systems.

사행 유로를 갖는 고분자 전해질 연료전지의 기체확산층 내부에서의 우회 유동 예측 (Prediction of Bypass Flow Rate through Gas Diffusion Layer in PEMFC with Serpentine Flow Channels)

  • 전세계;김경연
    • 한국수소및신에너지학회논문집
    • /
    • 제23권4호
    • /
    • pp.293-299
    • /
    • 2012
  • The serpentine flow channel is widely used in polymer electrolyte membrane fuel cells (PEMFCs) to prevent flooding phenomena because it effectively removes liquid water in the flow channel. The pressure drop between inlet and outlet increases as compared with straight channels due to minor losses associated with the corners of the turning configurations. This results in a strong pressure gradient between adjacent channels in specific regions, where some amount of reactant gas can be delivered to catalyst layers by convection through a gas diffusion layer (GDL). The enhancement of the convective flow in the GDL, so-called bypass flow, affects fuel cell performance since the bypass flow influences the reactant transport and thus its concentration over the active area. In the present paper, for the bipolar plate design, a simple analytic model has been proposed to predict the bypass flow in the serpentine type flow channels and validated with three-dimensional numerical simulation results.

수동 바이패스 필터를 이용한 단상 무변압기형 인버터 (Single-Phase Transformerless Inverter using Passive Bypass Filter)

  • 양민권;허준;이명철;김유진;최우영
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.129-138
    • /
    • 2018
  • Previous single-phase transformerless inverters used active bypass switching circuits that need auxiliary power switches to minimize ground leakage current. However, switching and gate driving losses are increased due to the use of additional power switches. To cope with this drawback, this work proposes a transformerless inverter using a passive bypass filter without any auxiliary power switch. The operation and control of the proposed inverter are described. The ground leakage current characteristics are analyzed for the proposed inverter with the passive bypass filter. The experimental results of the proposed inverter for a 1.0kW prototype system are presented.

동시에 시행한 체외순환 없이 시행하는 관상동맥우회수술과 위전절제술 (Simultaneous Off-pump Coronary Artery Bypass Surgery and Total Gastrectomy)

  • 박정옥;류재욱;서필원
    • Journal of Chest Surgery
    • /
    • 제40권1호
    • /
    • pp.56-59
    • /
    • 2007
  • 흉통을 주소로 입원한 65세 남자 환자가 불안정형 협심증으로 관상동맥우회수술이 필요한 상태였다. 이학적 검사상 심한 빈혈소견이 동반되었고 혈색소는 5.7 g/dL이었다. 빈혈에 대한 검사 중에 위내시경검사상 출혈을 동반하고 있는 4 cm크기의 종괴가 위소만부에서 관찰되었다. 조직학적 검사상 선암으로 진단되었고, 종양의 출혈로 인해 관상동맥우회수술과 위전절제술이 동시에 계획되었다. 환자는 체외순환 없이 관상동맥우회수술을 시행 받은 후에 동시에 이어서 위전절제술을 시행 받았다 수술 후 경과는 순조로웠다. 환자는 술 후 12일째 퇴원하여 9개월째 추적관찰 중이다. 이에 저자들은 협심증과 위암을 동시에 수술하였기에 보고하는 바이다.

태아양 모델을 이용한 실험적 태아 심폐우회술 (Experimental Fetal Cardiopulmonary Bypass in the Fetal Lamb Model)

  • 이정렬;임홍국;김원곤;김종성;최정연;김용진
    • Journal of Chest Surgery
    • /
    • 제32권6호
    • /
    • pp.495-503
    • /
    • 1999
  • 배경: 본 연구에서 저자 등은 태아양 모델을 이용하여 태아 심폐우회술의 기술적인 측면에서의 가능성을 실험하고 심폐우회술과 관계된 태아의 혈역학과 태반기능에 관한 기초자료를 얻고자 하였다. 대상 및 방법: 제태기간 120~150일 되는 11마리의 태아양을 이용하여 정중흉골절개하에 주폐동맥과 우심이에 각각 12 G, 14~18 F 크기의 도관을 삽관하여 30분 동안 심폐우회술을 시행하였다. 어미양은 케타민 정주를 이용한 전신마취를 시행하였고 태아양에 대하여는 근육이완제만을 사용하였다. 실험군을 롤러펌프와 인공 막성산화기(Micro-safe, Polystan 회사제, 덴마아크)를 이용한 군(8마리, 산화기군)과 바이오펌프(Bio-pump, Bio-Medicus 회사제, 미국)와 태반을 산화기로 이용한 군(3마리, 태반군)으로 이분하여 혈류, 태아 혈역학 및 태반기능을 관찰하였다. 결과: 태아양의 평균체중은 3.6$\pm$1.3(1.9~5.2) kg이었다. 산화기군에서 심폐기 가동 중에는 평균동맥압 69.8~82.6 mmHg, 평균동맥혈산소분압치 201.7~220.9 mmHg, 평균심방압 4.1~4.3 mmHg, 평균심박동수 169~182 /min, 평균혈류 140.3~164.0 ml/kg/min로 유지되었으나 체외순환을 정지하는 순간부터 급격한 심기능 및 가스소견의 악화가 관찰되어 평균동맥압 29.0~57.4 mmHg, 평균동맥혈이산화탄소분압치 61.9~77.1 mmHg 등이었다. 태반군에서는 심폐우회 시작 직후 평균 44.7 mmHg에서 14.4 mmHg로 급격한 혈압 강하가 관찰되었고 이때 혈류는 평균 74.3~97.0 ml/kg/min 였다. 가스소견 역시 평균동맥혈이산화탄소분압치와 pH가 각각 평균 61.9~129.6 mmHg, 6.7~6.8이었으며 체외순환 정지후에는 심실세동으로 혈역학 측정이 불가능하였다. 결론: 연구자 등은 본 연구를 통하여, 비록 태아의 장기생존을 위한 태아 혈역학의 유지 및 태반혈류의 확보에는 어려움을 겪었으나 양모델을 이용한 실험적 태아 심폐우회술을 시도하여 태아 심장수술의 기술적인 측면에서의 가능성을 확인하였다. 향후 프로스타글란딘 억제제의 추가, 태아에 전척추마취의 적용, 펌프의 개선 및 순환회로의 축소화 등의 수정된 태아 체외순환에 관한 연구가 계속되어야 할 것으로 사료된다.

  • PDF

배기 가스 유량 제어를 이용한 버너방식 디젤 입자상물질 제거 장치의 재생 (Regeneration of Burner Type Diesel Particulate Trap System Through Active Exhaust Gas Feeding)

  • 김재업;박동선;이만복;김응서
    • 한국자동차공학회논문집
    • /
    • 제5권1호
    • /
    • pp.1-13
    • /
    • 1997
  • The key point that guarantees the durability of the ceramic monolith filter is to lower peak temperature and temperature gradient inside filter during regeneration. The control of the exhaust gas flow rate into the filter, by the bypass technique of the exhaust gas, enables the gas temperature in filter to be constant for regeneration. A couple of methods, which are the ON/OFF and PID control of the bypass valve, were used for feedback control of the gas temperature. These techniques showed that the ceramic filter was regenerated perfectly under the peak temperature and peak temperature gradient limitations for durability.

  • PDF

LockPickFuzzer: ADB 기반 퍼징 기법을 활용한 안드로이드 잠금 화면 메커니즘의 취약점 탐색 (LockPickFuzzer: Exploring Vulnerabilities in Android Lock Screen Mechanisms through ADB-Based Fuzzing)

  • 고대훈;김형식
    • 정보보호학회논문지
    • /
    • 제34권4호
    • /
    • pp.651-666
    • /
    • 2024
  • 안드로이드 디바이스는 다양한 인증 방식을 제공하는 잠금 화면으로 사용자 데이터를 보호한다. 그러나 잠금 화면이 활성화된 상태에서도 Android Debug Bridge(ADB)를 통해 디바이스에 접근할 수 있다. 본 연구에서는 ADB의 특성을 활용하여 잠금 화면 보안 메커니즘을 우회할 수 있는 방법을 탐색하고자 한다. 이를 위해 ADB 명령어를 분석하고, 잠금 화면 보안을 무력화할 수 있는 명령어 조합을 자동으로 탐색하는 퍼징 테스트 도구인 LockPickFuzzer를 제안한다. LockPickFuzzer의 성능을 평가하기 위해 안드로이드 14를 탑재한 갤럭시 S23과 픽셀 8을 대상으로 실험을 진행하였다. 실험 결과, 잠금 화면의 인증 정보를 탈취하거나 우회할 수 있는 두 가지 ADB 명령 조합을 발견하였다. 이 발견된 취약점에 대해 삼성 보안팀에 리포트를 제출하였고, 한 가지 ADB 명령어 조합에 대해 삼성전자에서 공식적으로 인정받았다 (SVE-2023-1344). LockPickFuzzer는 자동으로 작동하며, 안드로이드 디바이스에서 ADB 명령어 조합으로 인한 보안 취약점을 효과적으로 탐지하는 데 기여할 것으로 기대된다.

위성 TV용 이중 하향 변환기의 설계 및 제작 (Design and Implementation of Double Down-Converter for Satellite TV)

  • 이승대
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.840-845
    • /
    • 2013
  • 본 논문에서는 LC 필터 기술을 기반으로 하는 광대역 주파수 이중 하향변환기(Frequency Double Down-Converter)를 설계 및 제작하였다. 설계한 이중 하향변환기는 저잡음 증폭기, 혼합기, IF 증폭기, LC 필터 등으로 구성되며, DC-Block 커패시터와 RF-Bypass 커패시터로 구성된다. 설계 시에 기존 변환기의 능동소자를 수동소자로 구현하였으며 이에 따라 전력감소 및 저가의 비용을 실현할 수 있었다. 측정 결과, 제작한 주파수 이중 하향변환기는 중심 주파수 63MHz 에서 대역폭 100MHz (13~113MHz)인 광대역을 실현하였으며, 이득은 약 40dB 임을 확인하였다.