• Title/Summary/Keyword: Active source

Search Result 1,451, Processing Time 0.027 seconds

Design of Semi-Active suspension system for Railway Vehicle with narrow gauge (협궤 차량용 준능동형 현가 시스템 설계)

  • Lee Nam-Jin;Kim Chul-Gun;Nam Hak-Gi
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.473-478
    • /
    • 2005
  • Active suspension system improves ride quality with optimized suspension force, generated by electric, hydrolic or pneumatic power and controlled by micro-processor under various operation condition of train, while Semi-Active susepsion system provides optimized and controlled characteristics of suspensions such as damping coefficient without external energy. The benefits fo Semi-Active suspension are no required power source and to be made compact with lower cost. Train with narrow gauge could be more unstable than one for normal or wide gauge, and it could be more vibrated than others one by external force such as aerodynamic force and track irregularity. So, the reduced ride quality could be improved with appling with Semi-active suspension system. In this report, the Semi-Active suspension system for narrow gauge train shall be proposed and to prepare the Roller Rig test of this train, integration of system, development of control algorithm and confirmation of its performance with simulation tool would be taken.

  • PDF

Over Current Protection Schemes for Active Filters with Series Compensators

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.3
    • /
    • pp.134-145
    • /
    • 2004
  • This paper presents and analyses protection schemes for a series active compensator, which consists of a Unified Power Quality Conditioner (UPQC) or a hybrid active power filter. The proposed series active compensator operates as a high impedance "k(D)" for the fundamental components of the power frequency during over current conditions in the distribution system. Two control strategies are proposed in this paper. The first strategy detects the fundamental source current using the p-q theory. The second strategy detects the fundamental component of the load current in the Synchronous Reference Frame (SRF). When over currents occur in the power distribution system momentarily, the proposed schemes protect the series active compensator without the need for additional protection circuits, and achieves excellent transient response. The validity of the proposed protection schemes is investigated through simulation and compared with experimental results using a hybrid active power filter systems.

Constant DC Capacitor Voltage Control based Strategy for Active Load Balancer in Three-phase Four-wire Distribution Systems

  • Win, Tint Soe;Tanaka, Toshihiko;Hiraki, Eiji;Okamoto, Masayuki;Lee, Seong Ryong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.176-183
    • /
    • 2014
  • Three-phase four-wire distribution systems are used for both three-phase three-wire loads and single-phase two-wire consumer appliances in South Korea, Myanmar and other countries. Unbalanced load conditions frequently occur in these distribution systems. These unbalanced load conditions cause unbalanced voltages for three-phase and single-phase loads, and increase the loss in the distribution transformer. In this paper, we propose constant DC capacitor voltage control based strategy for the active load balancer (ALB) in the three-phase four-wire distribution systems. Constant DC capacitor voltage control is always used in active power line conditioners. The proposed control strategy does not require any computation blocks of the active and reactive currents on the distribution systems. Balanced source-side currents with a unity power factor are obtained without any calculation block of the unbalanced active and reactive components on the load side. The basic principle of the constant DC capacitor voltage control based strategy for the ALB is discussed in detail and then confirmed by both digital computer simulations using PSIM software and prototype experimental model. Simulation and experimental results demonstrate that the proposed control strategy for the ALB can balance the source currents with a unity power factor in the three-phase four-wire distribution systems.

Active Window system based on Finite Thickness Window Model (유한 두께 창문 모델을 적용한 능동 소음제어 창문)

  • Kwon, Byoung-Ho;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.763-768
    • /
    • 2012
  • Active window system which can reduce the environmental noises, such as traffic noise and construction noise, from an open window into a room was proposed in the previous works. The key idea of the proposed active window system was that the control sources are approximately collocated with the primary noise source in terms of the acoustic power for global noise reduction throughout the interior room. Moreover, because it is important not to intrude into the living space in the building environment, no error sensors were used and an open-loop control method using control sources at the window frame and the reference sensors outside the room was used for the proposed system. The open-loop control gain was calculated by the interior room model assumed as the semi-infinite space, and the interior sound field was estimated by Rayleigh integral equation under the baffled window model assumption. However, windows with a finite thickness should were considered for the calculation of the open-loop control gain of the active window system since these are representative of most window cases. Therefore, the finite thickness window model based on the Sgard's model was derived and the open-loop control gain using the interior sound field estimated by that model was calculated for active window system. To compare the performance of these two models, a scale-model experiment was performed in an anechoic chamber according to noise source directions. Experimental results showed that the performance for the thickness window model is better than the baffled window model as the angle with respect to the perpendicular direction is larger.

  • PDF

A Method Enabling Exploitation of Spatial Diversity and Physical Layer Security in an Extreme Case of Source-Wiretapping without a Jamming Beamformer

  • Tran, Truc Thanh;Kong, Hyung Yun
    • Journal of Communications and Networks
    • /
    • v.17 no.5
    • /
    • pp.482-490
    • /
    • 2015
  • This article exploits spatial diversity for jamming to prevent wiretapping in the extreme case in which an eavesdropper is located near the source and a common jamming signal is unavailable. To address this challenge, the jamming signal is allowed to carry a random binary message. Then, it is proposed that the active intermediate node transmits this jamming signal and the decoding of this signal at both source and destination is physically secured as result of using the physical-layer security method. If the source and the destination securely and correctly decode this jamming message, the source transmits another message which is created from combining its information message and the decoded message using the network-coding method. Therefore, this method prevents the transmissions from being eavesdropped upon by the source-wiretapping.

Embedded Switched-Inductor Z-Source Inverters

  • Nguyen, Minh-Khai;Lim, Young-Cheol;Chang, Young-Hak;Moon, Chae-Joo
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.9-19
    • /
    • 2013
  • In this paper, a ripple input current embedded switched-inductor Z-source inverter (rESL-ZSI) and a continuous input current embedded switched-inductor Z-source inverter (cESL-ZSI) are proposed by inserting two dc sources into the switched-inductor cells. The proposed inverters provide a high boost voltage inversion ability, a lower voltage stress across the active switching devices, a continuous input current and a reduced voltage stress on the capacitors. In addition, they can suppress the startup inrush current, which otherwise might destroy the devices. This paper presents the operating principles, analysis, and simulation results, and compares them to the conventional switched-inductor Z-source inverter. In order to verify the performance of the proposed converters, a laboratory prototype was constructed with 60 $V_{dc}$ input to test both configurations.

Finding the Information Source by Voronoi Inference in Networks (네트워크에서 퍼진 정보의 근원에 대한 Voronoi 추정방법)

  • Choi, Jaeyoung
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.6
    • /
    • pp.684-694
    • /
    • 2019
  • Information spread in networks is universal in many real-world phenomena such as propagation of infectious diseases, diffusion of a new technology, computer virus/spam infection in the internet, and tweeting and retweeting of popular topics. The problem of finding the information source is to pick out the true source if information spread. It is of practical importance because harmful diffusion can be mitigated or even blocked e.g., by vaccinating human or installing security updates. This problem has been much studied, where it has been shown that the detection probability cannot be beyond 31% even for regular trees if the number of infected nodes is sufficiently large. In this paper, we study the impact of an anti-information spreading on the original information source detection. We consider an active defender in the network who spreads the anti-information against to the original information simultaneously and propose an inverse Voronoi partition based inference approach, called Voronoi Inference to find the source. We perform various simulations for the proposed method and obtain the detection probability that outperforms to the existing prior work.

Evaluation for Noise Reduction of the HVAC by Modification of CAM Curve (CAM 곡선 개선에 의한 차량용 공조기의 소음 저감 평가)

  • Jeong, J.E.;Jung, C.Y.;Seo, B.J.;Jeong, U.C.;Oh, J.E.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.787-797
    • /
    • 2011
  • The noise in a vehicle is an important factor for customers purchasing a car. Particularly, reduction of the noise that is generated from HVAC(heating, ventilation and air conditioning) is very important since it has considerable effects on interior noise. In general, identification of noise source is crucial to reduce noise level. The complex acoustic intensity method is widely used to obtain the accurate measurement and identification of noise source. Therefore, in the previous study, noise source of HVAC was identified through experimental approach using the complex acoustic intensity method. In this study, we are intended to confirm reduced level of noise by comparing the result between before and after modification of cam curve that is based on identified noise source of HVAC. It is found out that noise source of HVAC are motor and cam area using the complex acoustic intensity method in the previous study. We performed experiments to compare noise level between before and after modification of cam curve. Especially, it can be seen that complex acoustic intensity method using both active and reactive intensity is vital in devising a strategy for comparison to noise level. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.

Location Privacy Enhanced Routing for Sensor Networks in the Presence of Dormant Sources (휴면 소오스들이 존재하는 환경의 센서 네트워크를 위한 위치 보호 강화 라우팅)

  • Yang, Gi-Won;Lim, Hwa-Jung;Tscha, Yeong-Hwan
    • Journal of KIISE:Information Networking
    • /
    • v.36 no.1
    • /
    • pp.12-23
    • /
    • 2009
  • Sensor networks deployed in battlefields to support military operations or deployed in natural habitats to monitor the rare wildlifes must take account of protection of the location of valuable assets(i.e., soldiers or wildlifes) from an adversary or malicious tracing as well as the security of messages in transit. In this paper we propose a routing protocol GSLP(GPSR-based Source-Location Privacy) that is capable of enhancing the location privacy of an active source node(i.e., message-originating node) in the presence of multiple dormant sources(i.e., nodes lying nearby an asset whose location needs to be secured). Extended is a simple, yet scalable, routing scheme GPSR(greedy perimeter stateless routing) to select randomly a next-hop node with a certain probability for randomizing paths and to perform perimeter routing for detouring dormant sources so that the privacy strength of the active source, defined as safety period, keeps enhanced. The simulation results obtained by increasing the number of dormant sources up to 1.0% of the total number of nodes show that GSLP yields increased and nearly invariant safety periods, while those of PR-SP(Phantom Routing, Single Path), a notable existing protocol for source-location privacy, rapidly drop off as the number of dormant sources increases. It turns out that delivery latencies of GSLP are roughly less than two-fold of the shortest path length between the active source and the destination.

Hybrid Series Active Power filter Based on Performance Function Theory for 3-Phase 4-wire System (성능함수제어 알고리즘을 이용한 3상 4선식 하이브리드형 직렬능동전력필터)

  • Kim, Jin-Sun;Shin, Jae-Hwa;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1096-1098
    • /
    • 2003
  • In this paper, the control algorithm and control methods for a combined system of shunt passive filter and series active filter in 3-phase 4-wire system are discussed. Moreover, the 3-phase 4-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and odd multiples of $3^{rd}$($9^{th}$, $15^{th}$, etc.) are termed as triple and zero sequence components that do not cancel each other in the system neutral. As a result, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control scheme for a series hybrid active system. This series active power filter acts not only as a harmonic compensator but also as a harmonic isolator. Hence the required rating of the series active filter is much smaller than that of a conventional shunt active filter. However, the performance of the combined system is greatly influenced by the filtering algorithm employed in the active power filter. This paper proposes a series active power filter scheme based on performance function. Some experiments was executed and experimental results from a prototype active power filter confirm the suitability of the proposed approach.

  • PDF