• 제목/요약/키워드: Active snubber

검색결과 95건 처리시간 0.033초

새로운 액티브 보조 공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터의 특성 (Characteristic of Three-Phase Voltage Type Soft-Switching Inverter using the Novel Active Auxiliary Resonant DC Link Snubber)

  • 성치호;허영환;문상필;박한석
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.114-121
    • /
    • 2016
  • This paper is Instant space vector PWM(Pulse Width Modulation)power conversion devices in switching power semiconductors from my generation to losses and switching when the voltage surge and current surge of electronic noise(EMI: Electro Magnetic Interference / RFI: Radio Frequency Interference)to effectively minimize the power soft-switching power conversion circuit topologies of auxiliary resonant DC tank for the purpose of high performance realization of the electric power conversion system by the high-speed switching of a semiconductor device(AQRDCT simultaneously : an active auxiliary resonance using auxiliary Quasi-resonant DC tank)DC link snubber switch has adopted a three-phase voltage inverter. AQRDCL proposed in this paper can reduce the effective and current peak stress of the power semiconductors of the auxiliary resonant snubber circuit compared to the conventional active-resonant DC link snubber, it is not necessary to install the clamp switch of the auxiliary resonant DC link, DC the peak current and power loss of the bus line can be reduced.

Induction Heating PWM High Frequency Inverter using New Active Auxiliary Resonant Snubber

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Kim, Hong-Sin;Jung, Sang-Hwa;Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.40-51
    • /
    • 2008
  • This research presents a new active auxiliary resonant snubber with for induction heating PWM high frequency inverter solving the problem of induction heating PWM high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the active auxiliary resonant snubber with for induction heating PWM high frequency inverter. The inverter circuit which is attempted by the on-off operation of a switch has the effect of reducing the power loss due to soft switching and high frequency switching. This confirms that power regulation is possible on a continuous basis from 0.25[kW] to 2.84[kW] where the duty factor(D) changes from 0.08 to 0.3 under zero current switching which operates by an asymmetrical pulse width modulating control. The power conversion efficiency is 95[%]. Due to these results, the active auxiliary resonant snubber for an induction heating PWM high frequency inverter is considered effective as a source of induction heating.

Three-Phase Current Source Type ZVS-PWM Controlled PFC Rectifier with Single Active Auxiliary Resonant Snubber and Its Feasible Evaluations

  • Masayoshi Yamamoto;Shinji Sato;Tarek Ahmed;Eiji Hiraki;Lee, Hyun-Woo;Mutsuo Nakaoka
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.127-133
    • /
    • 2004
  • This paper presents a prototype of three-phase current source zero voltage soft-switching PWM controlled PFC rectifier with Single Active Auxiliary Resonant Commutated Snubber (ARCS) circuit topology. The proposed three-phase PFC rectifier with sinewave current shaping and unity power factor scheme can operate under a condition of Zero Voltage Soft Switching (ZVS) in the main three phase rectifier circuit and zero current soft switching (ZCS) in auxiliary snubber circuits. The operating principle and steady-state performances of the proposed three-phase current source soft-switching PWM controlled PFC rectifier controlled by the DSP control implementation are evaluated and discussed on the basis of the experimental results of this active rectifier setup.

New Active Snubber Boost PFC Converter for Efficiency Improvement in Home Appliances Applications

  • Jeong, In Wha;Park, Mingyu;Um, Kee-Ju;Heo, Chang Jae;Lee, JunHo;Kim, Kwangsoo;Suh, Bum-Seok;Kim, Yong-Wook;Kim, Rae-Young
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.289-290
    • /
    • 2012
  • This paper proposes a new active snubber boost PFC converter to provide a zero-voltage-switching (ZVS) turn-on condition and reduce electromagnetic interference (EMI) noise in home appliances and renewable energy applications, including solar or fuel cell electric systems. The proposed active snubber circuit enables a main boost switch of the boost-type PFC or grid converter to turn on under a ZVS condition and reduce the switching losses of the main boost switch. Moreover, for the purpose of a specialized intelligent power module (IPM) fabrication, the proposed boost circuit is designed to satisfy some design aspects such as space saving, low cost, and easy fabrication. Simulation and experimental results of a 2kW IPM boost-type PFC converter are provided to verify the effectiveness of the proposed active snubber boost circuit.

  • PDF

스누버 전류를 고려한 개선된 SVPWM 인버터를 이용한 상전류센서없는 전동기 구동 (Single Current Sensor Technique considering a Snubber Current and a Modified SVPWM Inverter for AC Motor Drives)

  • 주형길;신휘범;안희욱;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.399-402
    • /
    • 1999
  • The single sensor technique reconstructing phase currents from the dc-link current without phase current sensors in proposed. When the duration of active vector is too short for the snubber current to reduce, the dc-link current including the snubber current gives large detection error. The solution is presented by analyzing the snubber current and modifying the switching sequences. This scheme is simple, requires only one sampling a period and has good results for detecting the phase currents.

  • PDF

새로운 액티브 스너버를 이용한 소프트 스위칭 PWM 컨버터 (Soft Switching PWM Converter Using a New Active Snubber)

  • 조만철;김주용;문상필;서기영;권순걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.261-263
    • /
    • 2006
  • A new soft switched active snubber circuit is proposed to achieve zero voltage and zero current switching for all the switching devices in PWM DC-DC converters. The unique location of the snubber and inductor ensures low current/voltage stresses and commutation losses. With a saturable reactor, the conduction loss of auxiliary switch could be further minimized. A boost converter adopting this technique is presented as an example, to illuminate its operation principles and derive the design procedures. Simulation and hardware implementation have been made to validate its performance. Some other basic PWM DC-DC topologies using the proposed snubber have also been given.

  • PDF

새로운 액티브 스너버를 이용한 고주파 PWM DC-DC 컨버터의 토플로지 (Topologies of hige freguency PWM DC-DC converter using a new active snubber)

  • 조만철;김칠용;서기영;이현우;권순걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1010-1011
    • /
    • 2006
  • A new soft switched active snubber circuit is proposed to achieve zero voltage and zero current switching for all the switching devices in PWM DC-DC converters. The unique location of the snubber capacitor and inductor ensures low current/voltage stresses and commutation losses. With a saturable reactor, the conduction loss of the auxiliary switch could be further minimized. A boost converter adopting this technique is presented as an example, to illuminate its operation principles and derive the design procedures. Simulation and hardware implementation have been made to validate its performance. Some other basic PWM DC-DC topologies using the proposed snubber have also been given.

  • PDF

New Active Snubber Cells for High Step-up Interleaved DC-DC Converters

  • 하이 뜨란;김선주;아드스티라;정현주;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.18-20
    • /
    • 2018
  • This paper proposes a new pair of Active Snubber Cells (ASCs) which can fully provide soft switching for a Floating-output Double Boost Converter (FDBC). Besides that, the introduced ASCs are applicable for all basic DC-DC converters. Main switches of the FDBC turn on and off with ZVS. However, the main diodes are ZCS turned off. Furthermore Snubber switches are turned on and off with ZCS and ZVS respectively. It worthy to mention also that the soft switching for snubber diodes of the presented cells is achieved. A 1.5kW, 100kHz prototype of the FDBC with the proposed ASCs was built and evaluated; and the maximum attained efficiency is 97.3%.

  • PDF

Space Vector Modulated Three-Phase Soft-Switching Active Rectifier and Its Performance Evaluations

  • Fujii Yuma;Ahmed Tarek;Imamura Kosuke;Hiraki Eiji;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.213-215
    • /
    • 2003
  • This paper presents an instantaneous space vector modulated voltage source type three-phase soft-switching PFC rectifier using a single auxiliary resonant DC Link snubber for alternative energy utilizations. in the first place, the operating principle of an active auxiliary resonant DC link snubber circuit is described including its unique features. In the next place, the simulation analysis of three-phase soft-switching PWM rectifier is implemented, and the operating performances or the three-phase voltage-fed PWM rectifier treated here, which can operate under the conditions of sinewave line current shaping and utility power factor are evaluated and discussed on tile basis of this simulation results.

  • PDF

능동 스너버를 갖는 ZVT PWM AC-DC 승압 컨버터 (ZVT PWM AC-DC Boost Converter with Active Snubber)

  • 김춘삼;성원기;이정문;최찬석;김수홍
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.214-220
    • /
    • 2008
  • Most of converter system could obtain almost unity power factor and make input current sinusoidal waveform, but they have many problems, such as electromagnetic interference and switching losses caused by switching noise in main switch. To solve these problems in hard switching PFC converter, soft switching converter using a resonant between capacitor and inductor is invented In this paper, advantages and disadvantages of conventional ZVT(Zero-Voltage-Transition) soft switching converter using a auxiliary resonant circuit is discussed. Then Improved ZVT soft switching converter proposed. This improved ZVT converter's operation principal, specific property, design scheme of main are described. From Simulation and experiment results of conventional ZVT soft switching and improved ZVT soft switching converter with active snubber, characteristics of the converter are confirmed.