• 제목/요약/키워드: Active power loss

검색결과 271건 처리시간 0.029초

무효전력을 고려한 한계송전손실계수 산정 방법론 개발 및 현물시장에의 적용 (The Development of the Transmission Marginal Loss Factors with Consideration of the Reactive Power and its Application to Energy Spot Market)

  • 박종배;이기송;신중린;김성수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권7호
    • /
    • pp.429-436
    • /
    • 2003
  • This paper presents a new approach for evaluating the transmission marginal loss factors (MLFs) considering the reactive power. Generally, MLFs are represented as the sensitivity of transmission losses, which is computed from the change of the generation at reference bus by the change of the load at the arbitrary bus-i. The conventional evaluation method for MLFs uses the only H matrix, which is a part of jacobian matrix. Therefore, the MLFs computed by the existing method, don't consider the effect of the reactive power, although the transmission losses are a function of the reactive power as well as the active power. To compensate the limits of the existing method for evaluating MLFs, the power factor at the bus-i is introduced for reflecting the effect of the reactive power in the evaluation method of the MLFs. Also, MLFs calculated by the developed method are applied to energy spot markets to reflect the impacts of reactive power. This method is tested with the sample system with 5-bus, and analyzed how much MLFs have an effect on the bidding/offer price, market clearing price(MCP), and settlement in the competitive energy spot market. This paper compared the results of MLFs calculated by the existing and proposed method for the IEEE 14-bus system, and the KEPCO system.

능동 클램프형 전류원 하프브리지 컨버터의 효율 특성 분석 (Efficiency analysis of active-clamped current-fed half-bridge converter)

  • 박진주;임정규;정세교;송유진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.157-158
    • /
    • 2011
  • An active-clamped current-fed half-bridge converter is used for front-end converter for grid-connection of low voltage energy sources. In this paper, theoretical analysis on the loss and efficiency for an active-clamped current-fed half-bridge converter is presented. To analyze the loss of the presented converter, the RMS current of each device is derived and it's loss is calculated. The comparison between simulation result and computed value is presented to verify the validity of the theoretic results.

  • PDF

초음파를 이용한 저전력 Active RFID시스템의 구현가능성에 관한 연구 (Feasibility study of low power active RFID system based on the ultrasonic frequency)

  • 윤기훈;곽철현;김건욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.430-432
    • /
    • 2007
  • This paper proposes the possibility of SonicID system which is the active RFID based on the ultrasonic spectrum instead of using radio frequency. For the feasibility study, various performance indexes are measured in terms of power consumption and signal path loss onto the frequencies of 40KHz, 433MHz, and 2.4GHz. In addition to the line of sight condition, realistic situations are considered for diverse deploying environments. The results of these analyses demonstrate that the SonicID holds the potential to meet the needs of future advanced RFID system in a scalable fashion.

  • PDF

Analysis, Design and Implementation of a New Chokeless Interleaved ZVS Forward-Flyback Converter

  • Taheri, Meghdad;Milimonfared, Jafar;Namadmalan, Alireza;Bayat, Hasan;Bakhshizadeh, Mohammad Kazem
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.499-506
    • /
    • 2011
  • This paper presents an interleaved active-clamping zero-voltage-switching (ZVS) forward-flyback converter without an output choke. The presented topology has two active-clamping circuits with two separated transformers. Because of the interleaved operation of the converter, the output current ripple will be reduced. The proposed converter can approximately share the total load current between the two secondaries. Therefore, the transformer copper loss and the rectifier diodes conduction loss can be decreased. The output capacitor is made of two series capacitors which reduces the peak reverse voltage of the rectifier diodes. The circuit has no output inductor and few semiconductor elements, such that the adopted circuit has a simpler structure, a lower cost and is suitable for high power density applications. A detailed analysis and the design of this new converter are described. A prototype converter has been implemented and experimental results have been recorded with an ac input voltage of 85-135Vrms, an output voltage of 12V and an output current of 16A.

새로운 액티브 보조 공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터의 특성 (Characteristic of Three-Phase Voltage Type Soft-Switching Inverter using the Novel Active Auxiliary Resonant DC Link Snubber)

  • 성치호;허영환;문상필;박한석
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.114-121
    • /
    • 2016
  • This paper is Instant space vector PWM(Pulse Width Modulation)power conversion devices in switching power semiconductors from my generation to losses and switching when the voltage surge and current surge of electronic noise(EMI: Electro Magnetic Interference / RFI: Radio Frequency Interference)to effectively minimize the power soft-switching power conversion circuit topologies of auxiliary resonant DC tank for the purpose of high performance realization of the electric power conversion system by the high-speed switching of a semiconductor device(AQRDCT simultaneously : an active auxiliary resonance using auxiliary Quasi-resonant DC tank)DC link snubber switch has adopted a three-phase voltage inverter. AQRDCL proposed in this paper can reduce the effective and current peak stress of the power semiconductors of the auxiliary resonant snubber circuit compared to the conventional active-resonant DC link snubber, it is not necessary to install the clamp switch of the auxiliary resonant DC link, DC the peak current and power loss of the bus line can be reduced.

절연형 양방향 DC-DC 컨버터의 손실 성분 분석을 통한 변압기 권선비 설계 방법 (A Design Method of Transformer Turns Ratio with the Loss Components Analysis of an Isolated Bidirectional DC-DC Converter)

  • 정재헌;김학수;노의철;김흥근;전태원
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.434-441
    • /
    • 2016
  • This paper deals with transformer turns ratio design with the consideration of loss minimization in isolated bidirectional DC-DC converter. Generally, the rms value of current, magnitude of current at switching instance, and duty ratio of a converter vary according to the turns ratio of an isolation transformer in the converter under the same voltages and output power level. Therefore, the transformer turns ratio has an effect on the total loss in a converter. The switching and conduction losses of IGBTs and MOSFETs consisting of dual-active bridge converter are analyzed, and iron and copper losses in an isolation transformer and inductor are calculated. Total losses are calculated and measured in cases of four different transformer turns ratios through simulation and experiment with 3-kW converter, and an optimum turns ratio that provides minimum losses is found. The usefulness of the proposed transformer turns ratio design approach is verified through simulation and experimental results.

기판집적 도파관(SIW)을 기반으로 하는 고효율 능동 위상 배열안테나 (High Efficiency Active Phased Array Antenna Based on Substrate Integrated Waveguide)

  • 이해영
    • 한국전자파학회논문지
    • /
    • 제26권3호
    • /
    • pp.227-247
    • /
    • 2015
  • 저손실, 전자기 완전차폐, 고전력 특성을 갖는 기판집적 도파관(SIW)을 이용하여 X-band $8{\times}16$ 이중편파 능동 위상배열안테나 시스템을 구현하였다. 16-way SIW 전력분배 네트워크의 측정된 순수 삽입손실(0.65 dB)은 마이크로스트립 경우보다 1 dB 감소하였으며, SIW 부배열($1{\times}16$) 안테나 소자의 측정된 방사효율(73 %)은 약 2배(3 dB) 향상되었다. 이러한 SIW를 이용한 분배손실과 방사효율의 상당한 개선은 능동 위상 배열안테나 시스템에서 고전력 증폭기의 최대출력(P1 dB)을 저감하고, 총 전력소모를 약 30 % 절감할 것이다. SIW 기반으로 제작된 X-band $8{\times}16$ 이중편파 능동 위상 배열안테나 시스템을 이론적인 제어벡터만을 생성하여 0도, 5도, 9도, 18도의 정밀한(최대편차 2도) 빔 조향을 측정하였으며, 열주기/진공 시험에서 우주환경 적합성을 확인하였다. 고효율 SIW 배열안테나 시스템은 고성능 레이더는 물론 차세대 무선통신(5G)을 위한 Massive MIMO와 다양한 밀리미터파 통신시스템(60 GHz WPAN, 77 GHz 자동차 레이더, 초고속 디지털 전송시스템 등)에 매우 유용할 것으로 기대한다.

씰 투스 간극이 틸팅 패드 저어널 베어링 손실과 온도에 미치는 영향 (Effect on Seal Tooth Clearance on Power Loss and Temperature of Tilting Pad Journal Bearing)

  • 방경보;최용훈;조용주
    • Tribology and Lubricants
    • /
    • 제34권5호
    • /
    • pp.183-190
    • /
    • 2018
  • Tilting pad journal bearing is widely used for steam turbines because of its excellent dynamic stability. As the turbine capacity increases, power loss in the bearings becomes a matter of concern. Power loss in tilting pad journal bearings can be reduced by increasing the bearing clearance and reducing the pad arc length. In this study, the tilting pad journal bearing is tested by changing the seal tooth clearance to verify the static characteristics of the bearing. Bearing power loss and bearing metal temperature are evaluated to compare the bearing's performance and reliability for several test cases. The test bearing is a tilting pad journal bearing with 300.62mm inner diameter and 120.00mm active length. The bearing power loss, its metal temperature, and oil film thickness are measured and evaluated based on the rotor's rotational speed, oil flow rate, and bearing load. Test results show that a tilting pad journal bearing with large seal tooth clearance has 40% lower power loss compared with a bearing with a small seal tooth clearance. As the seal tooth clearance is increased, the power loss of the tilting pad journal bearing decreases. However, with respect to the bearing metal temperatures, a detuning point is observed that makes the minimum bearing metal temperature. Moreover, as the seal tooth clearance is increased, the oil film thickness increases due to high viscosity.

3차원(次元) 전류좌표(電流座標)에 의한 능동전력(能動電力)필터의 보상성능(補償性能) 평가(評價)를 위한 시뮬레이터 개발(開發) (Simulator Development for Evaluating Compensation Performance. of Active Power Filter using Three-Dimensional Space Current Co-ordinate)

  • 임영철;정영국;나석환;최찬학;장영학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.337-341
    • /
    • 1994
  • This paper describes an effort to develop a simulator of Active Power Filter (APF) by three dimentional(3-D) space current co-ordinate. System current is represented by 3-D vector composed of three current components - active, reactive and distorted. %THD (%Total Harmonics Distortion) can be converted to height-angle of system current vector and power factor can be defined on 3-D space current co-ordinate without loss of generality. Current of APF and power system can be analyzed by 3-D visualization of current vector trajectory. So, the computer simulation results show that the proposed method by 3-D space current co-ordinate make up for disadvantages of performance evaluation on time / frequency domain.

  • PDF

Four-Switch 3상 Z-소스 능동전력필터 (Four Switch Three-Phase Z-Source Active Power Filter)

  • 수효동;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.224-225
    • /
    • 2013
  • This paper describes the four switch three-phase Z-source active power filter. This novel configuration has many advantages like reduction of cost, switching loss and smaller drive circuit. The paper presents an application of direct current control(DCC) method in a three-phase parallel Z-source active power filter to reduce the harmonics generated by the nonlinear load. The compensation principles and dynamics of the system are discussed in detail. The results show that the proposed control strategy is feasible and efficient.

  • PDF