• 제목/요약/키워드: Active input current control

검색결과 128건 처리시간 0.026초

Control Strategy Compensating for Unbalanced Grid Voltage Through Negative Sequence Current Injection in PMSG Wind Turbines

  • Kang, Jayoon;Park, Yonggyun;Suh, Yongsug;Jung, Byoungchang;Oh, Juhwan;Kim, Jeongjoong;Choi, Youngjoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.244-245
    • /
    • 2013
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

델터 변조 방식을 이용한 전류형 무효전력 보상장치 (Current-Fed Reactive Power Compensator Using Delta Modulation Technique)

  • 백형래;김한성
    • 대한전기학회논문지
    • /
    • 제41권3호
    • /
    • pp.244-252
    • /
    • 1992
  • This paper describes a reactive power compensator using current-source delta modulation converter, which compensates the reactive power in the ac sides of 3-phase rectifier. In the conventional current control methods for the current-type reactive power compensators, it is usual to compare the reactive reference current signal with the triangular wave and hence to generate the ON-OFF signals for the reactive power compensator. To improve the response as well as the control capability, the delta modulated current control technique is used in this paper. As a result, the input power factor is improved close to unity and both simulation and experimental results show good compensating performances.

  • PDF

전압형 전력용 능동필터의 교류입력측 LCL 필터 설계 (Design of AC Input LCL filter for Voltage Fed Active Power Filter)

  • 노재석;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.194-197
    • /
    • 2001
  • In this paper, the design method of LCL filter at the AC input side of a voltage fed active power filter is proposed. The characteristics of harmonics suppression and current control performance of active power filter are described using the analysis of the relation of these characteristics and DC voltage, switching frequency, and AC inductor values. The design examples are shown and the validity of the proposed design method is verified through the PSIM simulation.

  • PDF

동기기를 사용한 계통연계형 가변속 풍력발전 시스템의 AC-DC-AC 컨버터 구현 및 제어 (Implementation and Control of AC-DC-AC Power Converter in a Grid-Connected Variable Speed Wind Turbine System with Synchronous Generator)

  • 송승호;김성주;함년근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권12호
    • /
    • pp.609-615
    • /
    • 2005
  • A 30kW electrical power conversion system is developed for a variable speed wind turbine. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and the frequency of the generator output vary according to the wind speed, a 6-bridge diode rectifier and a PWM boost chopper is utilized as an ac-dc converter maintaining the constant dc-link voltage with only single switch control. An input current control algorithm for maximum power generation during the variable speed operation is proposed without any usage of speed sensor. Grid connection type PWM inverter converts dc input power to ac output currents into the grid. The active power to the grid is controlled by q-axis current and the reactive power is controlled by d-axis current with appropriate decoupling. The phase angle of utility voltage is detected using software PLL(Phased Locked Loop) in d-q synchronous reference frame. Experimental results from the test of 30kW prototype wind turbine system show that the generator power can be controlled effectively during the variable speed operation without any speed sensor.

Analysis and Control of a Modular MV-to-LV Rectifier based on a Cascaded Multilevel Converter

  • Iman-Eini, Hossein;Farhangi, Shahrokh;Khakbazan-Fard, Mahboubeh;Schanen, Jean-Luc
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.133-145
    • /
    • 2009
  • In this paper a modular high performance MV-to-LV rectifier based on a cascaded H-bridge rectifier is presented. The proposed rectifier can directly connect to the medium voltage levels and provide a low-voltage and highly-stable DC interface with the consumer applications. The input stage eliminates the necessity for heavy and bulky step-down transformers. It corrects the input power factor and maintains the voltage balance among the individual DC buses. The second stage includes the high frequency parallel-output DC/DC converters which prepares the galvanic isolation, regulates the output voltage, and attenuates the low frequency voltage ripple ($2f_{line}$) generated by the first stage. The parallel-output converters can work in interleaving mode and the active load-current sharing technique is utilized to balance the load power among them. The detailed analysis for modeling and control of the proposed structure is presented. The validity and performance of the proposed topology is verified by simulation and experimental results.

전류제어 능동 클램프 포워드-플라이백 컨버터의 동특성 해석 및 제어회로 설계 (Dynamic Analysis and Control Design of Current-Mode Controlled Active-Clamp Forward-Flyback Converter)

  • 임원석;강용한;최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.374-377
    • /
    • 2002
  • This paper presents dynamic analyses and control design of the current-mode controlled active-clamp forward-flyback converter. The circuit averaging technique is used to extract the small-signal circuit model for the power stage From the small-signal circuit model of the power stage, the open-loop transfer functions are derived and used for the compensation design. The analysis results are verified using an experimental converter that delivers a 3.3V/10A output from a $40\~60V$ input source.

  • PDF

New Control Method for Power Decoupling of Electrolytic Capacitor-less Photovoltaic Micro-Inverter with Primary Side Regulation

  • Irfan, Mohammad Sameer;Shin, Jong-Hyun;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.677-687
    • /
    • 2018
  • This paper presents a novel power decoupling control scheme with the bidirectional buck-boost converter for primary-side regulation photovoltaic (PV) micro-inverter. With the proposed power decoupling control scheme, small-capacitance film capacitors are used to overcome the life-span and reliability limitations of the large-capacitance electrolytic capacitors. Then, an improved flyback PV inverter is employed in continuous conduction mode with primary-side regulation for the PV power conditioning. The proposed power-decoupling controller shares the reference for primary side current regulation of the flyback PV inverter. The decoupling controller shapes the input current of the bidirectional buck-boost converter. The shared reference eliminates the phase-delay between the input current to the bidirectional buck-boost converter and the double frequency current at the PV primary current. The elimination of the phase-delay in dynamic response enhances the ripple rejection capability of the power decoupling buck-boost converter even with small film capacitor. With proposed power decoupling control scheme, the additional advantage of the primary-side regulation of flyback PV inverter is that there is no need to have an extra current sensor for obtaining the ripplecurrent reference of the decoupling current-controller of the power-decoupling buck-boost converter. Therefore, the proposed power decoupling control scheme is cost-effective as well as the size benefit. A new transient analysis is carried out which includes the source voltage dynamics instead of considering the source voltage as a pure voltage source. For verification of the proposed control scheme, simulation and experimental results are presented.

최대출력추종 제어를 포함한 단상 태양광 인버터를 위한 새로운 입출력 고조파 제거법 (A Novel Input and Output Harmonic Elimination Technique for the Single-Phase PV Inverter Systems with Maximum Power Point Tracking)

  • Amin, Saghir;Ashraf, Muhammad Noman;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.207-209
    • /
    • 2019
  • This paper proposes a grid-tied photovoltaic (PV) system, consisting of Voltage-fed dual-active-bridge (DAB) dc-dc converter with single phase inverter. The proposed converter allows a small dc-link capacitor, so that system reliability can be improved by replacing electrolytic capacitors with film capacitors. The double line frequency free maximum power point tracking (MPPT) is also realized in the proposed converter by using Ripple Correlation method. First of all, to eliminate the double line frequency ripple which influence the reduction of DC source capacitance, control is developed. Then, a designing of Current control in DQ frame is analyzed and to fulfill the international harmonics standards such as IEEE 519 and P1547, $3^{rd}$ harmonic in the grid is directly compensated by the feedforward terms generated by the PR controller with the grid current in stationary frame to achieve desire Total Harmonic Distortion (THD). 5-kW PV converter and inverter module with a small dc-link film capacitor was built in the laboratory with the proposed control and MPPT algorithm. Experimental results are given to validate the converter performance.

  • PDF

전력품질 개선을 위한 단상 전압제어형 능동전력필터 시스템에 관한 연구 (A Study on the Single Phase Voltage-Controlled Active Power Filter for Power Quality Improvement)

  • 손진근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권5호
    • /
    • pp.238-245
    • /
    • 2003
  • In this paper, a single Phase voltage source voltage-controlled active power filter(APF) for power quality improvement was proposed. The proposed APF has the performance of harmonic suppression and unity power factor correction. The performance of harmonic suppression can be obtained by controlling the waveshape of the APF output voltage to be sine wave. And, unity power factor is controlled by the reactive power control loop of the APF output. Simulation and experimental results using diode rectifier showed that the voltage-controlled APF, unlike the current-controlled APF, can reduce the voltage harmonics as well as current harmonics. Also the results showed that the input dover factor and power quality were greatly improved.

밀리미터파 탐색기용 Ka 대역 능동 PIN 다이오드 리미터 설계 및 제작 (Design and Fabrication of Ka-Band Active PIN Diode Limiter for a Millimeter Wave Seeker)

  • 양승식;임주현;나영진
    • 한국전자파학회논문지
    • /
    • 제23권2호
    • /
    • pp.220-228
    • /
    • 2012
  • 본 논문에서는 밀리미터파 탐색기의 수신기 보호용으로 사용할 낮은 누설 전력을 가지는 Ka 대역 능동 리미터 설계 및 제작 기법을 설명하였다. 낮은 누설 전력을 구현하기 위해서 송신 펄스 주기 신호와 입력 전력의 크기에 따라 리미터를 제어할 수 있는 능동 리미터 제어 회로를 제안하였다. 능동 리미터는 전형적인 2단 수동 리미터에 방향성 결합기, 검파기, 연산 증폭기 및 과전류 보호용 저항으로 구성된 궤환 회로로 구성되어진다. 제작된 Ka 대역 능동 리미터 측정 결과, 주파수 대역은 1 GHz, 약 신호 시 삽입 손실은 3.5 dB 이하, 능동 제어시 최대 감쇄량 46 dB, 4 W RF 입력 시 정상 누설 전력은 -7.5 dBm을 보였다.