• Title/Summary/Keyword: Active fire

Search Result 163, Processing Time 0.025 seconds

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Clinical Study on Relationship between Pattern Identifications and Heart Rate Variability (변증과 심박변이도의 상관성 연구)

  • Choi, Sang Ok;Park, Sun Young;Jeong, Hui Jin;Jung, So Youn;Ahn, Su Yeun;Kim, Kyoung Min;Kim, Young Kyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.3
    • /
    • pp.318-326
    • /
    • 2013
  • This study was performed to investigate relationship between each pattern identification and heart rate variability(HRV) indices. We analyzed 201 subjects who participated in stroke check up. We classified the subjects into four groups of pattern identifications; Fire-Heat pattern(FH), Yin Deficiency pattern(YD), Qi Deficiency pattern(QD) and Dampness-Phlegm pattern(DP) that based on Korean Standard Pattern Identifications for Stroke-III. We investigated significance of HRV indices between each pattern identification and heart rate variability indices. The total number of the subject group was 201, whereas the groups were divided into four groups; Fire-Heat pattern group(n=47), Yin Deficiency pattern(n=65), Qi Deficiency pattern(n=33), and Dampness-Phlegm pattern(n=56). SDNN, TP, Ln(TP), VLF, Ln(VLF), LF, Ln(LF) and HF were significantly higher in the Fire-Heat pattern(FH) group than other groups of pattern identifications, but there was no differences among the Yin Deficiency group, the Qi Deficiency group and the Dampness-Phlegm group. Ln(HF), LF(NORM), HF(NORM) and LF/HF ratio were significantly higher in the Fire-Heat group than in the Qi Deficiency group. However, there was no significant differences among the Dampness-Phlegm group, the Yin Deficiency group, Fire-Heat group and the Qi Deficiency group. Through this study, we found out some significant relationships between each pattern identification group and HRV indices. The result of this study demonstrates that sympathetic nerve was more active in the Fire-Heat group than other groups.

Investigation on Fire Resistance of High-Performance Cement Motar with Recycled Fine Aggregate Mixed by Two-Stage Mixing Approach (2단계 배합을 사용한 순환잔골재 혼입 고성능 시멘트 모르타르의 내화성능 연구)

  • Park, Sung-Hwan;Choi, Jun-Ho;Lee, Chi Young;Koo, Min-Sung;Chung, Chul-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.23-29
    • /
    • 2022
  • This study was conducted to confirm the applicability of recycled aggregates as aggregates for structural concrete as a way to respond to the shortage of natural aggregates. The two-stage mixing approach developed by Tam et al. is known to be a method that can improve the mechanical performance of recycled aggregate concrete without the installation of new additional facilities. In this work, modified version of two stage mixing approach, which was used in our earlier work, was introduced to prepare mortar specimens with recycled fine aggregate, and the compressive strength and fire resistance were compared to mortar mixed with normal mixing approach. According to the experimental results from mortar with recycled fine aggregate, the use of two-stage mixing approach was found to be more effective than normal mixing approach for compressive strength development. In addition, the residual strengths of the mortar with two-stage mixing approach was higher than mortar made of normal mixing approach after exposure to 600 and 900 ℃. It is possible to manufacture high-performance cement composites with recycled fine aggregates through the active use of the two-stage mixing approach.

Analysis of Global Volcanic Activities since 2010 (2010년 이후 지구에서 발생한 화산활동 분석)

  • Yun, Sung-Hyo;Ban, Yong-Boo
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.409-419
    • /
    • 2016
  • The number of volcanoes erupted during the past ten thousand years(Holocene period) on this planet is known to stand around 1,520. Of those volcanoes, the number of active volcanoes during the six-years and seven-month period(January 2010 through the end of July 2016) is totals 209. These findings show that an average of approximate 90 volcanoes erupted every year since 2010. It is also found that over 90 percent of those active volcanoes took place in the circum-Pacific volcanic belt, which is commonly called 'Ring of Fire'. This status coincides with the distribution maps of active volcanoes on the earth: about 80 percent on subduction zone of the convergence of lithospheric plate; 15 percent on spreading zone; 5 percent on intra-plate zone. The period given in this research during 350 weeks, the following three volcanoes showed a frequency of more than 300 times eruption: Kilauea(Hawaii, USA, 338 times), Sheveluch(Kamchatka, Russia, 337 times), and Aira(Kyushu, Japan, 301 times). According to the survey conducted during the given period, there is no conspicuous increase in the frequency of volcano activities. It rather shows that volcanic eruptions took place almost evenly every year.

Study on Emergency Generator Capacity Selection(PG3) in the Chemical Plant (화학 플랜트에서의 비상발전기 용량선정 방안(PG3)에 관한 연구)

  • Lee, Seung-Jae;Jo, Man-Young;Kim, Se-Yong;Kim, Eun-Tae;Kang, Byoung-Wook;Park, Han-Min;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.55-60
    • /
    • 2015
  • PG and RG methods are widely known method for calculating the capacity of the emergency generator in construction electrical installation. PG and RG methods are mainly used as a saving a life, fire protection, fire fighting in construction. Because no long distance between the emergency generator and electric motor feeder, the relatively small motor power in construction electrical installation, the capacity of generator in PG and RG methods are little problem of voltage and reactive power of generator. However in many cases the application of the PG and RG method is difficult in the Chemical Plant because it is long distance between the generator and the motor Feeder and motor capacity is very large. Motor starting power factor is about 0.2 lagging power factor and motor starting current is about 6times during motor staring. Also Most of the staring current component is a reactive power component. therefore, it is many cases that lack of reactive power and excess of allowable voltage drop limit and After selection of emergency diesel generator, problems happen during motor starting. Therefore, to be selection of effective emergency generator, active generator power, reactive power and the required reactive power during large motor starting should be considered in chemical plant. It is also required of the verification process through simulation because hand calculation is very difficult considering study cases.

A Study on the Recognition of Fire-fighters on Korean Civil Anti-Disaster Organization for Public Safety (국민안전을 위한 민간 방재조직에 대한 소방관들의 인식 연구)

  • Chae, Jong-Sik;Lee, Si-Young
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.2
    • /
    • pp.137-148
    • /
    • 2021
  • This study sought for an improvement plan of the overall preventive activity of Korean Citizen-Corps-Active-In-Disaster(CAIND) by utilizing the fact that The fire-fighters, who are focusing on social disaster response works, are surveyed for their awareness of the vivid expertise to Korean CAIND. This group is defined as the assistant organization in law about disaster prevention which, the local residents willingly made to handle the situation of disaster occurrence. Since the characteristics of volunteer activities are also inherent, related issues are also reviewed at the same time to resolve any unclear arguments by disaster prevention activity characteristics of Korean Citizen Corps Active in Disaster. Through the results, the study provided three major suggestions for an improvement plan. The results of the study are as follows: First, the quota management system of Korean CAIND that considers the characteristics of rural areas should be actively supplemented. Second, the current reward system for Korean CAIND activities at large disaster sites should be surely improved. Third, the current education and training system of Korean CAIND to satisfy regional conditions should be newly established. The results of this study are largely expected to be utilized as a basic data to develop Korean CAIND in the future.

A Study on the Field Test of the Solar Heating System with Parabolic Solar Collectors Integrated the Roof of a Residential Building (지붕대체형 집광집열기를 이용한 태양열 난방시스템의 동절기 성능 평가)

  • Kim, Yong-Ki;Lee, Tae-Won;Yoon, Kwang-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.61-69
    • /
    • 2007
  • The final energy consumption in the building sector in Korea represents almost 20% of the total energy consumption. Besides, Space heating and hot water generation in Korea are based on fossil fuels, with a serious environmental impact. Despite the popularity of simple solar domestic hot water systems, active solar space heating remains, for various reasons, marginal. And thus, the aim of this paper is to demonstrate potentialities of solar assisted space heating systems, both technically and economically. From this study found that the solar heating system with CPC solar collectors integrated the roof of a single-story residential building shares $50{\sim}55%$ of the annual heating load.

An Analysis of the 119 EMS System using the Standardized Record on the Efficient Emergency Medical Information Delivery Media (효율적인 응급의료 정보전달매체로서의 119구급활동일지 분석)

  • Rho, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.64-71
    • /
    • 2010
  • Records of 255 patients was analyzed statistically according to the contents of the record form. T patients' records were collected through the visit of emergency department in one hospital by the 119 Emergency Medical Services system from January 1 to February 8, 2009. In conclusion, the total entry was the investigation of 119 ambulance run report in 62.1% of subjects. The highest record of receiving hospital item was 100.0% and the lowest record of medical control item was 0.4% of subjects. Increasing the entry of 119 ambulance run report in efficient emergency medical information delivery media needed to suggest that increasing the number of specialists on the staff, medical staffs have an active interest and feedback, rule to item arrangement of prehospital ambulance run report, continuous education in the importance of record.

Development of Damage Estimation Method using Sensor of Multiple Function in RC Beam (철근 콘크리트 보에서의 다기능 센서를 이용한 손상 추정법 개발)

  • Kim, Ie-Sung;Park, Kang-Geon;Kim, Wha-Jung
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.184-188
    • /
    • 2008
  • Performance degradation of concrete structures is generally caused by structural deteriorations, such as cracks. It may result in serious defects of concrete structures. Methods of damage detection are used a visual angle of human or non-destructive test, and they are using various sensors. Problems of crack damage detection are occurred to directions of cracks by using 1 axial type of accelerometer in concrete element. In addition, these sensors are not used to occurring fire in RC building. Thermocouple sensors are able to using measurement of temperature in fire, and then deformations of main element and structures are not used. In this study, fundamental studies for development of multiple function sensor using 3 axial type of accelerometer and electric resistance property of thermocouple sensors are discussed estimation to stability of structures when happened form active load or fire, and so on.

  • PDF

Effect of Harmonic Generation and Countermeasures (고조파발생에 따른 영향과 대책 연구)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.91-97
    • /
    • 2015
  • Skyscrapers, large business buildings, and IT consumers use many appliances, and the electrical power stems can cause fires by overheating. This can result in damaged capacitors, lost data, rising ground potential, and communication obstacles from linear or nonlinear high frequency. To make sure of that we investigated 7 spots of a building, among which 6-spots were fair but the other one needed high frequency control. Spots 3, 6, and 7 needed diagnostic workup, and spots 2, 3, and 5 considered 5 high frequency currents. A phase is all of good but the high frequency current is greater than the standard level except for spot 1. As a result, a zigzag transformer or active filter needs to be installed, and the efficiency needs to be upgraded by investigating load unbalance factors and power factors.