• Title/Summary/Keyword: Active fire

Search Result 163, Processing Time 0.034 seconds

Methods to Improve Fire Suppression Capability by Forest Fire Simulation Analysis (산불화재 시뮬레이션분석에 의한 화재진압능력 개선방안)

  • Jeong-Il, Lee;Sung-bae, Cho
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.4
    • /
    • pp.125-134
    • /
    • 2022
  • Forest fires in Korea usually start in the fall and occur every year until spring. Most wildfires are human resources that combine topographical characteristics and carelessness, and failure to respond in the initial stage and lack of cleanup are spreading to large-scale wildfires. In order to prevent these wildfires, active cooperation from the public is essential. As can be seen from recent wildfires, the attention of the public is needed above all else because large-scale wildfires in Korea are occurring due to the people's negligence. If a wildfire spreads and becomes large, it causes damage to life and property, and the damage is irreversible. In this study, various methods were used to prevent forest fires and improve initial suppression ability. In order to minimize damage, the model analyzed by the 119 Special Rescue Team in Gangwon, Chungcheong and nearby forest fires was analyzed on the combustion progress and wind direction by time period. The propagation speed by the wind direction was simulated. Until now, most of the wildfires have been extinguished by firefighting, but I hope that the Forest Service will take the lead and maintain coordination with related organizations.

A Study on the Satisfaction of Non Face to Face Real Time Education Focused on Firefighter in COVID-19 (코로나19 상황에서 소방공무원을 대상으로 한 비대면 실시간 교육 만족도에 관한 연구)

  • Park, Jin Chan;Baek, Min Ho
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.91-103
    • /
    • 2022
  • Purpose: After COVID-19, changes in the educational ecosystem take place and fire service academy education system have shifted from face-to-face into non fact-to-face. So, the educational effect of fire officials is decreased and the satisfaction level is also decreased. In this study, we want to examine the current status of non-face-to-face real-time remote education and supplement the problems to improve the educational methods, the educational environment, etc. Method: This study is an independent variable that affects non-face-to-face real-time remote education, consisting of education system environment, self-efficacy of computers, contents (education contents, structure, design, etc.), and proper interaction. A dependent variable was selected with satisfaction for non-face-to-face real-time remote education. In addition, it was selected and analyzed as an active property of learning motivation and learning attitude as control variables. Result: The better the content and the more active the learning motivation and the attitude toward learning, the higher the satisfaction of non-face-to-face real-time remote education, and the more active the learning motivation and the attitude toward learning, the more positive the computer self-efficacy and the satisfaction of learning Conclusion: In order to increase the satisfaction of non-face-to-face real-time education due to COVID-19, education designers or professors need to provide non-face-to-face education contents that can increase the aggressiveness of their learning motivation and learning attitude, and to increase the satisfaction of education for learners by increasing computer self-efficacy through pre-education of non-face-to-face education systems.

Function Analysis for the active surveillance system of urban transit (도시철도의 능동적 감시체계를 위한 기능 분석)

  • An, Tae-Ki;Shin, Jeong-Ryul;Lee, Woo-Dong;Han, Seok-Yoon;Kim, Moon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1027-1028
    • /
    • 2008
  • Most of the urban transit operation company in Korea have a passive surveillance system to monitor the status of the passengers and facilities in the urban transit service area. The surveillance system is based on CCTV, closed circuit television, and several sensors, such as a fire sensor. However, this system has some limitations to prevent and cope with the emergency quickly. So the urban transit operation companies have plans to be change their surveillance system to be active. The active surveillance system has an intelligent function to detect the event predefined by managers automatically. To construct the active surveillance system, there are a standard concept design and a function analysis. In this paper, we propose the classification of the functions of the active surveillance system for urban transit. We divide the functions into five parts, ordinary monitoring, safety monitoring, environment monitoring, administration support, and record management. And we describe the systems related to the every functions to clarify the classified functions.

  • PDF

Coping methods related with post-traumatic stress types for the firefighters who experienced the Dae-gu subway fire disaster (대구지하철 참사를 경험한 소방관의 외상 후 스트레스유형에 따른 대처방식)

  • Baek, Mi-Lye
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.3
    • /
    • pp.5-15
    • /
    • 2007
  • The purpose of this study was to identity the distribution of post-traumatic stress types and coping methods and to find the relationship between the post-traumatic stress types and the coping methods, for firefighters who experienced in Dea-Gu Subway Fire Disaster. The Subjects of this study were 126 firefighters who experienced Deagu Subway Disaster. Q questionnaire developed by Q-study and coping methods instrument based on that of Folkman & Lazaruswas revised and complemented by Kim Jung Hee was used. Data were analyzed by t-test, ANOVA using SPSS. The results of this study were as follows : 1. The distribution of post-traumatic stress types were 52.4% of Emotional arousal trauma, 34.1% of Trauma experience persistence and 13.5% of Physiological symptom experience. 2. The difference of post-traumatic stress types according to the general characteristics were significantly related to the physical injury(p = .010). 3. The minimum score of coping with post-traumatic stress types was 0.07, the maximum was 2.96 and the mean score was 1.27. 4. The coping methods according to the general characteristics were significantly different at active coping method according to educational level(p = .001), passive coping method according to educational level(p = .003) and passive coping method according to diagnosis(p = 0.20). 5. The mean score of active coping method according types were Emotional arousal trauma(1.505), trauma experience persistance(1.322) and Physiological symptom experience(1.276). The mean score of passive coping method related with types were Emotional arousal trauma(1.328), trauma experience persistance(1.254) and Physiological symptom experience(1.219).

  • PDF

Study on Dust Explosion Characteristics of Acetylene Black (Acetylene Black의 분진폭발 특성 연구)

  • Jae Jun Choi;Dong Myeong Ha
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.38-43
    • /
    • 2024
  • Recently, with the expanding market for electronic devices and electric vehicles, secondary battery usage has been on the rise. Lithium-ion batteries are particularly popular due to their fast charging times and lightweight nature compared to other types of batteries. A secondary battery consists of four components: anode, cathode, electrolyte, and separator. Generally, the positive and negative electrode materials of secondary batteries are composed of an active material, a binder, and a conductive material. Acetylene Black (AB) is utilized to enhance conductivity between active material particles or metal dust collectors, preventing the binder from acting as an insulator. However, when recycling waste batteries that have been subject to high usage, there is a risk of fire and explosion accidents, as accurately identifying the characteristics of Acetylene Black dust proves to be challenging. In this study, the lower explosion limit for Acetylene Black dust with an average particle size of 0.042 ㎛ was determined to be 153.64 mg/L using a Hartmann-type dust explosion device. Notably, the dust did not explode at values below 168 mg, rendering the lower explosion limit calculation unfeasible. Analysis of explosion delay times with varying electrode gaps revealed the shortest delay time at 3 mm, with a noticeable increase in delay times for gaps of 4 mm or greater. The findings offer fundamental data for fire and explosion prevention measures in Acetylene Black waste recycling processes via a predictive model for lower explosion limits and ignition delay time.

A Study on the Necessity and Contents of the Installation Criteria of the Fire Suppression Education & Training Facilities (화재진압 교육훈련시설 설치기준의 필요성 및 내용에 관한 연구)

  • Song, Woo Seung;Ham, Seung Hee;Yoon, Myung O
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.62-71
    • /
    • 2014
  • The importance of the firefighting education & Training is being magnified in order to enhance and strengthen a firefighters' ability and to reduce the firefighters' fatality and casualty. Therefore, It is needed to expand the facilities. In this study, with a comparative analysis of the global firefighting education & training facilities for fire suppression, we try to present the necessity and the basic contents of the establishing the installation criteria for the domestic firefighting education & training facilities. It has to contain specific purpose of the training and minimum standards for the structures with a guarantee of an international level. Naturally, the top priority is a safety of trainees and trainers. And, it should pay attention to a higher effectivity of the training course with a active reflection of the standard operation procedures' scenarios. Simultaneously, by securing a similarity and a compatibility to the other standards, it must maintain the balance of a whole standard.

The Study of Air Sampling Smoke Detector (공기흡입형 연기감지장치에 관한 연구)

  • 이복영;이병곤
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.86-91
    • /
    • 2003
  • Since the air stream in the room controlled by HVAC system affects on he expected response of conventional detectors which are designed in accordance with normal characteristics of air stream in the fire incident, unexpected operation time delay may occur in fire. In order to solve this problem and to improve sensitivity so that to initiate fire in its early stages for minimizing damage and protecting people, we studied and developed Air Sampling Smoke Detector. The Air Sampling Smoke Detector is a kind of active-type fire detection system. it draws air continuously from the protected area through an air sampling pipe network to the smoke density analyzer. This study presents smoke density analysing technique and air intake balancing technique through an air sampling pipe network. As a result of evaluating, Air Sampling Smoke Detector was much more sensitive than conventional smoke detectors that passively wait for smoke to reach them and was not affected by ambient airflow in the room by means of balanced air intake through the sampling holes.

Experience of a Disaster Medical Assistant Team activation in the fire disaster at Jecheon sports complex building: limitation and importance of rescue (제천 스포츠복합건물 화재 재난에서의 권역재난의료지원팀 활동 경험 고찰: 한계점과 구조의 중요성)

  • Jung, Seung Gyo;Kim, Yoon Seop;Kim, Oh Hyun;Lee, Kang Hyun;Kim, Kwan-Lae;Jung, Woo Jin
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.585-594
    • /
    • 2018
  • Objective: This study was designed to report on the progress of the fire at Jecheon sports complex and to assess the adequacy of Disaster Medical Assistant Team (DMAT)'s activities in response to the fire disaster. Methods: We conducted a retrospective review based on camera recordings and medical records that were recorded at the disaster site for assessment of activities. We cooperated with firefighters, police officers, local hospital medical staffs and public health personnel in Jecheon in order to classify patients in the disaster field and to understand the patients' progress. Results: At 15:53, the first request for emergency rescue came to the 119 general emergency call center, and a request for DMAT activation came at 16:28. DMAT arrived at the site at 17:04 and remained active until the following day at 00:43. The total number of casualties was 60, including 27 minimal (Green) patients, 29 expectant (Black) patients, three delayed (Yellow) patients, and one immediate (Red) patient. There were 32 patients who received on-site care by DMAT. Two patients were transferred from a local hospital to Wonju Severance Christian Hospital for hyperbaric oxygen therapy. Conclusion: Twenty-nine victims were found in the sports complex building, and there were 31 mildly to moderately injured patients in this fire disaster. The main cause of death was thought to be smoke suffocation. Although DMAT was activated relatively quickly, it was not able to provide effective activity due to the late rescue and difficulty with fire suppression.

An Quantitative Analysis of Severity Classification and Burn Severity for the Large Forest Fire Areas using Normalized Burn Ratio of Landsat Imagery (Landsat 영상으로부터 정규탄화지수 추출과 산불피해지역 및 피해강도의 정량적 분석)

  • Won, Myoung-Soo;Koo, Kyo-Sang;Lee, Myung-Bo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.3
    • /
    • pp.80-92
    • /
    • 2007
  • Forest fire is the dominant large-scale disturbance mechanism in the Korean temperate forest, and it strongly influences forest structure and function. Moreover burn severity incorporates both short- and long-term post-fire effects on the local and regional environment. Burn severity is defined by the degree to which an ecosystem has changed owing to the fire. Vegetation rehabilitation may specifically vary according to burn severity after fire. To understand burn severity and process of vegetation rehabilitation at the damaged area after large-fire is required a lot of man powers and budgets. However the analysis of burn severity in the forest area using satellite imagery can acquire rapidly information and more objective results remotely in the large-fire area. Space and airbone sensors have been used to map area burned, assess characteristics of active fires, and characterize post-fire ecological effects. For classifying fire damaged area and analyzing burn severity of Samcheok fire area occurred in 2000, Cheongyang fire in 2002, and Yangyang fire in 2005 we utilized Normalized Burn Ratio(NBR) technique. The NBR is temporally differenced between pre- and post-fire datasets to determine the extent and degree of change detected from burning. In this paper we use pre- and post-fire imagery from the Landsat TM and ETM+ imagery to compute the NBR and evaluate large-scale patterns of burn severity at 30m spatial resolution. 65% in the Samcheok fire area, 91% in the Cheongyang fire area and 65% in the Yangyang fire area were corresponded to burn severity class above 'High'. Therefore the use of a remotely sensed Differenced Normalized Burn Ratio(${\Delta}NBR$) by RS and GIS allows for the burn severity to be quantified spatially by mapping damaged domain and burn severity across large-fire area.

  • PDF

Isolation of Antimicrobial Peptides from Skin Secretions of the Oriental Fire-bellied Toad, Bombina orientalis

  • Hwang, Jeong-Ryeol;Yeo, Seong-Mun
    • Animal cells and systems
    • /
    • v.2 no.3
    • /
    • pp.361-365
    • /
    • 1998
  • Antimicrobial peptides are widely distributed in nature and appear to play important roles in the host defense of plants and animals. In this study, we isolated and characterized three antimicrobial peptides from skin secretions of the oriental fire-bellied toad, Bombina orientalis. These purified peptides were referred to as P1, P2, and P3 in order of their elution. P1, P2, and P3 have molecular weights of 2569, 2566, and 2370 Da by MALDI-TOF mass spectrometer, respectively. They are heat-stable, amphipathic peptides of 24-27 amino acids without cysteine residues. All three peptides are active against representative gram negative and gram positive bacterial species, and in particular, P1 appears to have distinctive antifungal activity. However, no significant hemolytic activity was found for these peptides.

  • PDF