• 제목/요약/키워드: Active failure

검색결과 403건 처리시간 0.028초

A physically consistent stress-strain model for actively confined concrete

  • Shahbeyk, Sharif;Moghaddam, Mahshid Z.;Safarnejad, Mohammad
    • Computers and Concrete
    • /
    • 제20권1호
    • /
    • pp.85-97
    • /
    • 2017
  • With a special attention to the different stages of a typical loading path travelled in a fluid confined concrete test, this paper introduces a physically consistent model for the stress-strain curve of actively confined normal-strength concrete in the axial direction. The model comprises of the five elements of: (1) a criterion for the peak or failure strength, (2) an equation for the peak strain, (3) a backbone hydrostatic curve, (4) a transient hardening curve linking the point of departure from the hydrostatic curve to the failure point, and finally (5) a set of formulas for the post-peak region. Alongside, relevant details and shortcomings of existing models will be discussed in each part. Finally, the accuracy and efficiency of the proposed model have been verified in a set of simulations which compare well with the experimental results from the literature.

통계적 방법을 통한 가스배관의 잔여수명 예측 (Probabilistic Assessment of life Time for Gas Pipe Lines)

  • 최병학;이상호;김영표;김우식;고영태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.234-239
    • /
    • 2004
  • A study on the probabilistic methodology for the estimation of the remaining life of Pressurized pipelines containing active corrosion defects is presented. This reliability assessment is earned out using extream value distribution of the corroded defects instead of already published failure perssure moded like NG18 or ASME B31G. The failure probability of pipelines depends on the number of corroded defects. and it could be calculated directly as the area exceeded a defined L V(Limited Value of corrosion depth). The remaining life of pressurized pipelines can also be estimated by the PDF of extream value distribution as calculating the exceeded area with a defined failure probability.

  • PDF

순간정전 보상을 갖는 능동 전력 필터 (An active power filter with an instantaneous power failure compensation)

  • 이용덕;이우철;이택기;김득수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.293-295
    • /
    • 2007
  • This paper proposes a control algorithm for the power supply to maintain the desired output voltage waveform when the instantaneous power failure occurs. The proposed system switches the control mode between the voltage-controlled and the current-controlled modes in the instantaneous power failure. The proposed control method has little steady-state error and good transient response. The validity of the proposed scheme is investigated through simulation and experimental results.

  • PDF

Remote Fault Diagnosis Method of Wind Power Generation Equipment Based on Internet of Things

  • Bing, Chen;Ding, Liu
    • Journal of Information Processing Systems
    • /
    • 제18권6호
    • /
    • pp.822-829
    • /
    • 2022
  • According to existing study into the remote fault diagnosis procedure, the current diagnostic approach has an imperfect decision model, which only supports communication in a close distance. An Internet of Things (IoT)-based remote fault diagnostic approach for wind power equipment is created to address this issue and expand the communication distance of fault diagnosis. Specifically, a decision model for active power coordination is built with the mechanical energy storage of power generation equipment with a remote diagnosis mode set by decision tree algorithms. These models help calculate the failure frequency of bearings in power generation equipment, summarize the characteristics of failure types and detect the operation status of wind power equipment through IoT. In addition, they can also generate the point inspection data and evaluate the equipment status. The findings demonstrate that the average communication distances of the designed remote diagnosis method and the other two remote diagnosis methods are 587.46 m, 435.61 m, and 454.32 m, respectively, indicating its application value.

Effect of multiple-failure events on accident management strategy for CANDU-6 reactors

  • YU, Seon Oh;KIM, Manwoong
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3236-3246
    • /
    • 2021
  • Lessons learned from the Fukushima Daiichi nuclear power plant accident directed that multiple failures should be considered more seriously rather than single failure in the licensing bases and safety cases because attempts to take accident management measures could be unsuccessful under the high radiation environment aggravated by multiple failures, such as complete loss of electric power, uncontrollable loss of coolant inventory, failure of essential safety function recovery. In the case of the complete loss of electric power called station blackout (SBO), if there is no mitigation action for recovering safety functions, the reactor core would be overheated, and severe fuel damage could be anticipated due to the failure of the active heat sink. In such a transient condition at CANDU-6 plants, the seal failure of the primary heat transport (PHT) pumps can facilitate a consequent increase in the fuel sheath temperature and eventually lead to degradation of the fuel integrity. Therefore, it is necessary to specify the regulatory guidelines for multiple failures on a licensing basis so that licensees should prepare the accident management measures to prevent or mitigate accident conditions. In order to explore the efficiency of implementing accident management strategies for CANDU-6 plants, this study proposed a realistic accident analysis approach on the SBO transient with multiple-failure sequences such as seal failure of PHT pumps without operator's recovery actions. In this regard, a comparative study for two PHT pump seal failure modes with and without coolant seal leakage was conducted using a best-estimate code to precisely investigate the behaviors of thermal-hydraulic parameters during transient conditions. Moreover, a sensitivity analysis for different PHT pump seal leakage rates was also carried out to examine the effect of leakage rate on the system responses. This study is expected to provide the technical bases to the accident management strategy for unmitigated transient conditions with multiple failures.

사면의 변이영역에서 보강재의 변형률 특성 (Strain Characteristics of Reinforcing materials in the transition zone of slopes)

  • 김경태;장대수;장기태;한희수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 사면안정학술발표회
    • /
    • pp.119-127
    • /
    • 2003
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are‘active zone’and‘passive zone’. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain distribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF

급성 활동성 심내막염의 수술적 치료 (Surgical Treatment of Acute Active Endocarditis)

  • 김성호
    • Journal of Chest Surgery
    • /
    • 제27권9호
    • /
    • pp.759-763
    • /
    • 1994
  • Between November 1990 and December 1993, 9 patients underwent surgical intervention for acute active endocarditis at Gyeongsang National University Hospital. All the patients were operated on within the first six weeks after onset of symptoms for various reasons. Surgical indications for early surgery were heart failure, systemic septic emboli, new murmur and growing vegetation. Most common infecting organism was Staphylococcus[55 %], and the others were Streptococcus, anaerobes, Candida and unknown in 1 case. The infection was in the mitral valve in 5 patients, the aortic valve in 2, the aortic and mitral in 1, and the aortic and pulmonary in 1. There was one operative death[11 %] and no late death. Preoperative Functional Class were II in 4 patients, III in 5 and after surgery all the patients improved to Class I. We conclude that early surgical intervention in acute active endocarditis is effective in most instances.

  • PDF

저속 유동장이 있는 원통형 연소기에서의 열-음향학적 불안정에 대한 능동 제어 연구 (Active Control of Thermoacoustic Instability in Cylindrical Combustor with Low Speed Flow Field)

  • 조상연;이용석;이수갑;배충식
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.914-921
    • /
    • 1998
  • Combusion instability due to thermoacoustic feedback in a ducted combustor usually excites severe noise and vibration, which could lead to result in the failure of the system or environmental dispute. In the present study, an active noise control(ANC) method with an adaptive algotithm is hired to suppress instability which has very discrete behavior in the frequency domain. Especially a feedback system is composed to evade hot environment of the combustor, and as a preliminary, the performance and stability of the controller is chekced by simulating the real situation with harmonic waves. Application to the real combustor showed serious reductions in sound pressure level by 20∼30 dB. It was also shown that the selected control system was very stable and effective.

  • PDF

An analytical expression for the dynamic active thrust from c-φ soil backfill on retaining walls with wall friction and adhesion

  • Shukla, Sanjay K.;Bathurst, Richard J.
    • Geomechanics and Engineering
    • /
    • 제4권3호
    • /
    • pp.209-218
    • /
    • 2012
  • This paper presents the derivation of an analytical expression for the dynamic active thrust from c-${\phi}$ (c = cohesion, ${\phi}$ = angle of shearing resistance) soil backfill on rigid retaining walls with wall friction and adhesion. The derivation uses the pseudo-static approach considering tension cracks in the backfill, a uniform surcharge on the backfill, and horizontal and vertical seismic loadings. The development of an explicit analytical expression for the critical inclination of the failure plane within the soil backfill is described. It is shown that the analytical expression gives the same results for simpler special cases previously reported in the literature.

네일로 보강된 구조물에서의 변이영역과 변형률 분포 (Strain Distribution of transition zone in a nailed wall)

  • 장기태;남궁한;유병선;김경태;권병근;이선경
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 사면안정 학술발표회
    • /
    • pp.235-239
    • /
    • 2000
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are 'active zone' and 'passive zone'. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain distribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF