• 제목/요약/키워드: Active Thermal Control

검색결과 127건 처리시간 0.033초

수소화된 산화아연을 이용한 박막 트랜지스터의 제작 및 열처리 효과 (Characterization of thin film transistors using hydrogenated ZnO films and effects of thermal annealing)

  • 이상혁;김원;엄현석;박진석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1412-1413
    • /
    • 2011
  • Effects of thermal annealing on electrical characteristics of thin film transistors (TFTs) using hydrogenated zinc oxide (ZnO:H) films as active channel were extensively investigated. The ZnO:H films were deposited at room temperature by RF sputtering. The device parameters of the ZnO:H-based TFTs, such as threshold voltage ($V_{th}$), subthreshold swing (S.S.), and on-off current ratio ($I_{on}/I_{off}$), were characterized in terms of the annealing temperature as well as the gas flow ratio of $H_2$/Ar.

  • PDF

연직파이프쿨링 공법에 의한 매스콘크리트 온도균열 제어 (Thermal Cracking Control of Mass Concrete by Vertical Pipe Cooling Method)

  • 서태석;임창근;조윤구
    • 한국건설순환자원학회논문집
    • /
    • 제2권3호
    • /
    • pp.233-238
    • /
    • 2014
  • 합벽, 옹벽, 교량 주탑과 같이 세장한 매스콘크리트 구조물의 경우 온도균열 제어를 위해 저발열 콘크리트 배합의 적용 및 균열유발줄눈의 설치 등이 주로 적용되고 있다. 하지만 이러한 대책이 적용되어도 세장한 매스 구조물들은 내부구속에 비해 외부구속이 크기 때문에 완벽한 균열제어가 불가능하고, 특히 균열이 발생하게 되면 거의 관통을 하기 때문에 온도균열제어를 위한 특별한 관리가 필요하다. 합벽, 옹벽, 교량 주탑과 같이 세장한 매스콘크리트 구조물의 적극적인 온도균열 제어를 위하여 기존의 파이프쿨링 공법을 개선시킨 연직파이프쿨링 공법을 개발하였으며, 현장 우수조/중수조 합벽 콘크리트에 적용이 되었다. 그 결과 합벽의 중심부 최고 온도를 10도 이상 낮츨 수 있는 것으로 나타났으며, 균열은 50% 이상 감소시킬 수 있는 것으로 나타났다.

위성 PCB 열해석을 위한 고 전력소산 소자의 모델링 연구 (A Study of High-Power Dissipation Parts Modeling for Spacecraft PCB Thermal Analysis)

  • 이미현;장영근;김동운
    • 한국항공우주학회지
    • /
    • 제34권6호
    • /
    • pp.42-50
    • /
    • 2006
  • 본 논문에서는 위성의 전장보드 열해석을 위한 최적의 열모델링 방법을 제안하였다. 플레이트 모델링 방법을 통한 보드 모델링에 고전력 소산 소자의 외부 및 내부 구조를 직접 모델링하는 방법을 새롭게 제안하였다. 이러한 모델링 방법을 다른 모델링과 비교 분석하여 효율성을 검토하였고 열진공 시험을 통해 검증하였다. 제시한 소자 모델링 방법으로 HAUSAT-2의 발열이 큰 통신보드의 열해석을 수행한 결과, 노드 네트워크 모델링 방법과 플레이트 모델링 방법의 단점을 모두 보완할 수 있었다. 또한, 소자 모델링 방법은 열적인 문제에 따른 소자 수준의 해결방안을 모색 후, 그에 따른 열해석을 수행하여 효과를 예측할 수 있으므로 열제어계 설계에도 효율적이다.

부하집중지로의 송전용량 증대를 위한 전압형 HVDC의 활용 방안 (Transfer Capability Enhancement to Population Center Using VSC HVDC System)

  • 오세승;한병문;차준민;장길수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권6호
    • /
    • pp.236-241
    • /
    • 2006
  • This paper presents a transfer capability enhancement process using VSC HVDC system which can control active power as well as reactive power. The transfer capability is constrained by stability like voltage stability as well as thermal rating of power system components. Transfer capability of the power system limited by these constraints may be enhanced by reactive power control ability and active power flow control ability of the VSC HVDC system. To enhance the transfer capability of the system using VSC HVDC, selection of the HVDC installation site is performed. In this work, power zones which consist of major power plants and their sinks are identified using power tracing and distribution factor. Alternative route of major AC transmission line in the power zone is identified as VSC HVDC system.

MEMS 기반 고체 추력기의 마이크로 점화기를 이용한 궤도 열제어 (On-orbit Thermal Control of MEMS Based Solid Thruster by Using Micro-igniter)

  • 하헌우;강수진;조문신;오현웅
    • 한국항공우주학회지
    • /
    • 제42권9호
    • /
    • pp.802-808
    • /
    • 2014
  • 학문적 연구개발 목적으로 개발된 MEMS 기술 기반 고체 추력기는 큐브위성에 탑재되어 극한 우주환경에서의 궤도 운용 및 기술검증시험을 실시할 예정이다. 이를 위해서는 고체 추력기가 허용온도 범위 내에 유지되도록 하여 점화시간지연에 따른 점화실패 방지 및 저온에서의 추력기의 구조건전성 확보가 가능하도록 열 제어를 실시하여야 한다. 본 논문에서는 MEMS 고체 추력기의 저온에서의 허용온도 유지를 위해 일반적으로 적용되는 온도센서와 히터를 활용하지 않고 고체 추진제 점화용 마이크로 점화기를 온도제어를 위한 센서 및 히터로 활용하는 효율적 열 제어 방안을 제안하였으며, 궤도 열 해석을 통해 열 제어 방식의 유효성을 입증하였다.

써모스탯 위치변화에 대한 인공위성 추진제 탱크의 열적 반응 해석 (Thermal Response Analysis of Satellite Propulsion Tank with Thermostat Location Variation)

  • 이균호;한조영;최준민;문홍열
    • 한국항공우주학회지
    • /
    • 제32권7호
    • /
    • pp.126-132
    • /
    • 2004
  • 위성 추진제 탱크의 열제어는 써모스탯에 의해 작동되는 히터를 이용해 수행된다. 적절한 위치에 써모스탯을 부착하는 것이 관건이지만 구형 탱크에서는 부착위치를 수치적으로 정확하게 부여하는 것이 불가능하다. 실제로는 도면에 대략적으로 위치를 제시한 후 작업자의 경험과 판단에 의존하여 써모스탯을 부착하는 것이 현실이다. 그러므로 써모스탯의 부착위치에 대한 민감도 해석을 수행함으로써 그에 따른 탱크의 열적 거동 및 열제어에 미치는 영향을 정량적으로 파악하였다. 실제 탱크 모듈 조립시 써모스탯의 부착위치에 대한 오차가 존재하더라도 설계 도면에 명시된 값보다 크게 벗어나지 않는 한 탱크의 열제어 성능은 충분히 보장되리라 판단된다.

통신해양기상위성의 탑재체 접속장치 설계에 관한 연구 (A Study of Payload Interface Unit Design for COMS (Communication Ocean & Meteorological Satellites))

  • 조영호;원주호;최재동;양군호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.369-370
    • /
    • 2008
  • The Payload Interface Unit (PIU) provides the interface between payload equipment (GOCI, MODCS and Ka Band P/L) and the SCU. The PIU is a MIL-STD-1553-Bus Remote Terminal (RT). The MPIU distributes commands to, acquires telemetry from and takes part in the thermal control of the payload equipment. When in ON mode, the PIU is completely observable and can be used for payload control. When in OFF mode, the PIU is non active except the thermal control electronics.

  • PDF

압전적층판의 열-압전-탄성 동적 비선형 작동특성 (Thermopiezoelastic Nonlinear Dynamic Characteristics of Piezolaminated Plates)

  • 오일권
    • 한국소음진동공학회논문집
    • /
    • 제15권7호
    • /
    • pp.836-842
    • /
    • 2005
  • Nonlinear dynamic characteristics of active piezolaminated plates are investigated with respect to the thermopiezoelastic behaviors. For largely deformed structures with small strain, the incremental total Lagrangian formulation is presented based on the virtual work principles. A multi-field layer-wise finite shell element is proposed for assuring high accuracy and non-linearity of displacement, electric and thermal fields. For dynamic consideration of thermopiezoelastic snap-through phenomena, the implicit Newmark's scheme with the Newton-Raphson iteration is implemented for the transient response of various piezolaminated models with symmetric or eccentric active layers. The bifurcate thermal buckling of symmetric structural models is first investigated and the characteristics of piezoelectric active responses are studied for finding snap-through piezoelectric potentials and the load-path tracking map. The thermoelastic stable and unstable postbuckling, thermopiezoelastic snap-through phenomena with several attractors are proved using the nonlinear time responses for various initial conditions and damping loss factors. Present results show that thermopiezoelastic snap-through phenomena can result in the difficulty of buckling and postbuckling control of intelligent structures.

화상 및 창상 치료용 외용제제 개발에 대한 기초 연구 (Studies on the Wound Healing by the PVA-soft hydrogel)

  • 조동현;신영희
    • 약학회지
    • /
    • 제48권1호
    • /
    • pp.55-59
    • /
    • 2004
  • A PVA-soft hydrogel, which is a semi-solid form in container, whereas after applying on the skin, it formed a thin layer within a few minutes. In this study, we prepared a novel type PVA-soft hydrogel containing 6-methyluracil as active drug, and the therapeutic value was characterized. To evaluate the therapeutic value of the PVA-soft hydrogel containing drug, various animal models, thermal burn model, incision & excision wound rat model were used. We also measured the wound size and breaking strength to calculate the wound healing extent after single or multiple administration. The wound size of soft hydrogel treated group decreased rapidly than that of control group after multiple dosing in excision wound model. And, the breaking strength of the soft hydrogel treated group was greater than that of control group in incision wound model.

하절기 고등학교 교실에서 재실자의 적극적 환경조절행동이 실내환경에 미치는 영향 (Effect of Occupants' Active Behaviour of Environmental Control on Indoor Environment in Summer's High School Classroom)

  • 곽노열
    • 대한건축학회논문집:구조계
    • /
    • 제35권5호
    • /
    • pp.181-190
    • /
    • 2019
  • In high school classrooms, it is reported that ventilation is often insufficient, increasing health risks among students. Therefore, indoor air quality in school classrooms is very important in terms of students' health and learning abilities. In this study, the effect of window opening, which is a control mechanism for air control in summer high school classrooms, on the change in air and indoor environment of the classroom was analyzed and physical conditions of indoor and air environment were observed during the classroom course, and satisfaction of the students and teachers was assessed with questionnaires. It was found that change rate of $CO_2$ concentration in classroom was effectively reduced by carrying out activity of opening the window by active environment control activity of occupants at break time, intermission time and cleaning time. And optimal window opening by students was presented to prevent unpleasantness and degradation of indoor air quality and the effects were analyzed.