• 제목/요약/키워드: Active Sound Control

검색결과 146건 처리시간 0.026초

계산속도를 증가시키기 위한 능동소음제어 알고리즘에 대한 연구 (A Study on the Active Noise Control Algorithm for Rreducing the Computation Rime)

  • 박광수;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.699-703
    • /
    • 1993
  • When the error path can be modeled as a pure delay, an adaptive algorithm for slowly time varying system is proposed to minimize the sound pressure level. This algorithm makes it possible to use the fittered-x LMS algorithm with on-line delay modeling of the error path. Another simple adaptive algorithm for pure tone noise is proposed which eliminates the cross term in the multiple error filtered-x LMS algorithm.

  • PDF

가스터빈 연소기내 2차연료분사에 의한 연소 불안정성의 제어 (Control of Combustion Instabilities in a Gas Turbine Combustors Through Secondary Fuel Injection)

  • 전충환
    • 한국연소학회지
    • /
    • 제3권1호
    • /
    • pp.59-69
    • /
    • 1998
  • The results of study on the active control of naturally occurring combustion oscillations with a single dominant frequency in an atmospheric dump combustor are presented. Control was achieved by an oscillatory infection of secondary fuel at the dump plane. A high speed solenoid valve with a maximum frequency of 250Hz was used as the actuator and a sound level meter, located at the combustor exit, measured the pressure fluctuations which served as the feedback signal for the control loop. Instability characteristics were mapped over a range of mean mixing section velocities from 6.7 m/s-9.3 m/s and with three mixing conditions. Different fuel/air mixing conditions were investigated by introducing varying percentages of primary fuel at two locations, one at the entrance to the mixing section and one 6 mixing tube diameters upstream of the dump plane. Control studies were conducted at a mean velocity of 9.3 m/s, with an air temperature of $415^{\circ}C$, and from flame blowout to the stoichiometric condition.

  • PDF

유동가진 공명기 내부의 음압 제어 (Control of Sound Pressure Inside a Flow Excited Resonator)

  • 황철호;박종범
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.196-199
    • /
    • 2005
  • Flow traveling over a cavity opening forms a vortex due to unstable shear layer and induces an aerodynamic pressure excitation from the diffusion of the vortex convecting out of the trailing edge of the opening. The interaction between the excitation force and the cavity response sustains resonance in the resonator(cavity) and locked-in vortex shedding at the leading edge of the opening. The aerodynamic excitation force can be described from the diffusion of the vortex over the trailing edge and the level of its diffusivity is related to the strength of vorticity seeded at the loading edge. In this study, the control scheme of the internal pressure oscillation was proposed from regulating the vorticity at the leading edge by use of an oscillating spoiler. It was found that the relative motion between the spoiler and the air mass at the cavity opening influenced vorticity strength and the control was achieved by direct feedback of the cavity pressure fluctuation to the actuator.

  • PDF

FxLMS를 이용한 단일 센서기반 능동 반향음 제어 시스템 (A single sensor based active reflection control system using FxLMS algorithm)

  • 김재필;지유나;박영철;서영수
    • 한국음향학회지
    • /
    • 제36권1호
    • /
    • pp.57-63
    • /
    • 2017
  • 본 논문에서는 FxLMS(Filtered-x Least Mean Square) 알고리즘을 이용한 단일 센서 기반의 능동 반향음 제어 알고리즘을 제안한다. 제안 알고리즘은 먼저 단일 센서 입력 신호로부터 입사음과 반향음을 분리하고, 분리된 신호들을 사용하여 반향음과 반대 위상을 갖는 제어 신호를 생성한다. 제어 신호는 센서 위치에서 반향음과 중첩되어 반향음의 음압을 감소시킨다. 적절한 신호 분리를 위해 반향 음향 경로와 제어 음향 경로가 필요하며 이는 swept sine 신호를 이용해 측정한 음향 응답으로부터 사전에 구할 수 있다. 효용성을 검증하기 위해 DSP(Digital Signal Processing) 보드를 사용하여 제안된 알고리즘을 실시간으로 구현하였으며, 공기 중 음향 덕트 환경에서 1 kHz 버스트 신호에 대해 반향음이 11.6 dB 감소함을 확인 하였다.

역모델을 이용한 디지털 능동 소음제어 시스템 (Digital Active Noise Control System Used Inverse Model)

  • 정찬수;이강욱;정양응
    • The Journal of the Acoustical Society of Korea
    • /
    • 제11권1E호
    • /
    • pp.56-63
    • /
    • 1992
  • The poblem of active oise control has been analysed using a adaptive signal processing technique. In this methods, the adaptive signal processor or model predicts the primary sound wave travelling along the acoustic plant and generates the secondary source 180° out of phase which attempts to attempts to attenuate the undesired noise by destructive interference. In the solutions presented here, acoustic propagation delay is considered as a part of the model which used the FIR filter. The effects of error path and auxiliary path transfer functioin are anayzed and a new on=-line technique for error path modeling, adaptive delayed inverse modeling is presented. In this study, using these new concepts, our system can more reduce the noise level in duct to 5dB-15dB than only using LMS algorithm system.

  • PDF

Modified FxLMS Algorithm for Active Noise Control and Its Real-Time Implementation

  • Mu, Xiangbin;Ko, JinSeok;Rheem, JaeYeol
    • 전자공학회논문지
    • /
    • 제50권9호
    • /
    • pp.172-176
    • /
    • 2013
  • This paper presents a modified filtered-x least mean square (FxLMS) algorithm to improve the stability of active noise control (ANC) system in realistic environment. A real-time ANC system employing modified FxLMS is designed and implemented on digital signal processor (DSP) board. The ANC system is evaluated for cancelling various tonal frequency noises in the range from 100 to 500 Hz and the performance is measured in terms of sound pressure level (SPL) attenuation. Experiment results show that a quiet zone with maximum 20 dB SPL attenuation can be generated around the location of error microphone.

원통형 밀폐공간 내부의 능동소음제어 (Active Noise Control In a Cylindrical Cavity)

  • 이호준;박현철;황운봉
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2302-2312
    • /
    • 2000
  • An active control of the transmission of noise through an aircraft fuselage is investigated numerically. A cylinder-cavity system was used as a model for this study. The fuselage is modeled as a fi nite, thin shel cylinder with constant thickness. The sound field generated by an exterior monopole source is transmitted into the cavity through the cylinder. Point force actuators on the cylinder are driven by error sensor that is placed in 3D cavity. Modal coupling theory is used to formulate the numerical models and describe the system behavior. Minimization of the acoustic potential energy in the fuselage is carried out as a performance index. Continuous parameter genetic algorithm is used to search the optimal actuator position and both results are compared.

제어 음원이 방음벽 모서리에 설치되는 능동방음벽의 오차센서 위치에 관한 연구 (Study on the Position of Error Sensors in an Active Soft Edge Noise Barrier)

  • 백광현
    • 한국소음진동공학회논문집
    • /
    • 제20권12호
    • /
    • pp.1216-1222
    • /
    • 2010
  • Based on the MacDonald's analytic model for the diffracted sound field of a semi-infinite noise barrier, computer simulations were performed for various positions of error microphones for an active noise barrier system. The simulation process also included the effects of floor reflections on both sides of the barrier. The results were also compared with Niu's simulation results and showed a straight line arrangement of sensors and actuators, in the order of primary source, secondary source and error microphone is better than over the top arrangement of the error microphones.

직접속도 피드백을 이용한 지능판의 능동구조음향제어 (Active Structural Acoustical Control of a Smart Panel Using Direct Velocity Feedback)

  • Stephen J, Elliott;Paolo, Gardonio;Young-Sup, Lee
    • 한국소음진동공학회논문집
    • /
    • 제14권10호
    • /
    • pp.1007-1014
    • /
    • 2004
  • This paper presents a study of low frequencies volume velocity vibration control of a smart panel in order to reduce sound transmission. A distributed piezoelectric quadratically shaped polyvinylidene fluoride (PVDF) polymer film is used as a uniform force actuator and an array of $4\;{\times}\;4$ accelerometer is used as a volume velocity sensor for the implementation of a single-input single-output control system. The theoretical and experimental study of sensor-.actuator frequency response function shows that this sensor-actuator arrangement provides a required strictly positive real frequency response function below about 900 Hz. Direct velocity feedback could therefore be implemented with a limited gain which gives reductions of about 15 dB in vibration level and about 8 dB in acoustic power level at the (1,1) mode of the smart panel. It has been also shown that the shaping error of PVDF actuator could limit the stability and performance of the control system.

고속철도 실내소음 저감을 위한 다중채널 ANC 시스템 모델링 (Multi-channel ANC System Modeling for Reducing KTX Interior Noise)

  • 장현석;김새한;이태오;구경완;이권순
    • 전기학회논문지
    • /
    • 제61권7호
    • /
    • pp.1069-1076
    • /
    • 2012
  • We use largely two methods, how to control the noise of the KTX, they are the passive noise control method and the active noise control method. The passive noise control has been used in a variety of ways since the KTX opening day, but lately it has shown the technical limitations by being dropped sharply. So, it is getting important to conduct the research about ANC that is able to reduce the ambient noise when the environmental-factor changes and be installed easily. To reduce a three-dimensional closed-space sound field like a car of a high-speed rail is hard to do using single channel ANC control system. Therefore we have to model the paths of the noise exactly for reducing the noise. And the control speakers and the error mics should be designed for optimal position. In this paper, we designed the transfer functions for modeling the noise paths under the influence of the distance between control speakers & error mics and primary noise speaker in TEST-BED where there is modeled as actual interior of KTX. We have made the modeling and the simulations of interior environment of KTX car by using three frequency bands of 120Hz, 280Hz, 360Hz. After the modeling, we compared the performance of active noise control and also we analyzed what to affect with difference in distance. After comparing of the performance using Pure Tone 120Hz, 280Hz, 360Hz at each modeling and then we simulated ANC for KTX's interior noise which we measured really and analyzed.