• Title/Summary/Keyword: Active Protection System

Search Result 220, Processing Time 0.031 seconds

A Study on the Protection Methods for Students from Inappropriate Internet Sites (불건전(不健全)한 인터넷 자원(資源)으로부터의 청소년(靑少年) 보호방안(保護方案)에 관한 연구(硏究))

  • Joo, Young-Ju;Kwak, Eun-Soon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.6 no.1
    • /
    • pp.5-20
    • /
    • 1999
  • With the advent of internet, the modern society is enjoying the benefits of the information age. As one of undesirable side effects of utilization of internet, however, it is often mentioned that young students are helplessly exposed to inappropriate and unqualified information. Therefore, in this paper, we will clarify the nature of inappropriate information to the younger generation and will argue for the needs of protecting the youth from inappropriate information. Especially the merits and limits of often motioned five different protective and regulatory measures are presented and analyzed, those are, establishment of acceptable use policy, active utilization of supervisory organization, promotion of Internet rating system, installation of filtering software, and legal and regulatory protection. As a fundamental means of resolving the problems, however, enforcement of systematic information literacy education, promotion of active utilization of sound information, development of search engines for the youth, design of diverse filtering softwares which can be selected by users, and increased attention by parents and teachers are suggested.

  • PDF

Design Verification of ECS Condenser Icing Protection System by Flight Test of T-50 Advanced Trainer (T-50 비행시험을 통한 환경제어계통 콘덴서 빙결방지 설계 검증)

  • Nam, Yong-Seog;Kim, Yeonhi;Song, Seok-Bong;Seo, Dong-Yun;Son, Won-Ik;Park, Sung-Soon
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.3
    • /
    • pp.40-44
    • /
    • 2008
  • T-50 ECS(environment control system) was designed to have freezing protection for the condenser. However during the ground and flight test, the freezing problem was occurred. This paper deals with the analysis of the freezing problem and introduces anti-freezing design using ADI(Active De-Icing) logic to solve the condenser freezing problem of T-50 ECS

  • PDF

Effect of Moisture on the Current Density for Optimized Cathodic Protection Condition in RC Structures (RC조 구조물의 최적 음극방식 조건 설정을 위한 함수율의 영향에 대한 평가)

  • Park, Dong-Cheon;Cho, Gyu-hwan;Ahn, Jae-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.29-30
    • /
    • 2013
  • Steel corrosion is the most serious problem in RC structures. Even though patch repair method is normally applied in repair system, the effectiveness is not enough. Cathodic protection in active repair method to deteriorated RC structures. FEM model was developed to simulate the optimized cathodic protection condition. Iro oxidation, hydrogen evolution and oxygen reduction were considered to expect current distribution. Moisture content in concrete which can affect the electrolyte conductivity was used as initial condition.

  • PDF

Safety Improvement of Military Primary Lithium Batteries by New Protection Circuit for Low Current System (신규 보호회로 적용을 통한 저전류 장비용 군 리튬전지 안전성 개선)

  • Youn, Seong Gi;Cho, Yu Seup
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.3
    • /
    • pp.256-261
    • /
    • 2019
  • The use of military lithium batteries in this field accelerates the generation of internal pressure because the active materials, lithium and the electrolyte, react to form sulfur dioxide gas. This also reduces the amount of electrolyte. In this condition, batteries can 'vent' or 'explode' especially when completely discharged. Such venting and explosion can be regarded as a safety accident, as toxic gases and shrapnel are ejected from the batteries which can harm the user. A DTaQ was carried out in 2017 as a quality problem solution project to solve this safety issue. A protection circuit was thereby developed, which included a micro controller unit (MCU) which can stop battery usage when in an over-discharging state by sensing its low-voltage condition. In 2018, this concept was expanded to lithium batteries for the remote controlled ammunition system. This paper reports results of the improved performance.

Active Video Watermarking Technique for Infectious Information Hiding System (전염성 정보은닉 시스템을 위한 능동형 비디오 워터마킹 기법)

  • Jang, Bong-Joo;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.8
    • /
    • pp.1017-1030
    • /
    • 2012
  • Most watermarking schemes for video contents protection have been studied to increase watermark's robustness and invisibility against such compressions and many kinds of signal processing after embedding copyright information to the original contents. This paper proposes an active watermarking that infect watermark to contents in the video decoding process using embedded infectious watermark and control signals from a video encoder side. To achieve this algorithm, we design a kernel based watermarking in video encoder side that is possible to recover the original contents and watermark in watermark detection procedure perfectly. And then, by reversible de-watermarking in video decoder side, we design the active watermark infection method using detected watermark and control signal. This means that our system can provide secure re-distributions of video contents without any quality degration and watermark bit error against transcoding or re-encoding processing. By experimental results, we confirmed that the embedded watermark was infected by video contents and codec perfectly without any declines of compression ratio and video quality.

Implementation of Uniform Deformation Theory in semi-active control of structures using fuzzy controller

  • Mohammadi, Reza Karami;Haghighipour, Fariba
    • Smart Structures and Systems
    • /
    • v.19 no.4
    • /
    • pp.351-360
    • /
    • 2017
  • Protection of structures against natural hazards such as earthquakes has always been a major concern. Semi-active control combines the reliability of passive control and versatility and adaptability of active control. So it has recently become a preferred control method. This paper proposes an algorithm based on Uniform Deformation Theory to mitigate vulnerable buildings using magneto-rheological (MR) damper. Due to the successful performance of fuzzy logic in control of systems and its simplicity and intrinsically robustness, it is used here to regulate MR dampers. The particle swarm optimization (PSO) algorithm is also used as an adaptive method to develop a fuzzy control algorithm that is able to create uniform inter-story drifts. Results show that the proposed algorithm exhibited a desirable performance in reducing both linear and nonlinear seismic responses of structures. Performance of the presented method is indicated in compare with passive-on and passive-off control algorithms.

Active Control System for Mitigation of Cable Vibration in Cable-Stayed Bridges (사장교 케이블 진동저감을 위한 능동제어시스템)

  • Hwang, In-Ho;Jeong, Cheol-Oh;Lee, Jong-Han;Lee, Jong-Seh
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.557-563
    • /
    • 2007
  • Rain-wind induced cable vibration can cause serious problems in cable-stayed bridge. External dampers attached to the cables have become widely accepted as an effective means for stay-cable vibration suppression. For very long stay-cables, however, such damper systems are rendered ineffective, as the dampers need be attached near the end of cables for aesthetic reasons. A recent study by the authors proposed that a movable anchorage system is replaced direct fixed support of the cable with a support through a bearing and damper. This paper extends the previous work by adding active control system to mitigate the cable vibration. The response of a cable with the proposed active control system is obtained and then compared to those of the cable with and without an external passive damper. The results show that the active control system can provide superior protection than the passive control system for a cable vibration.

Semi-active damped outriggers for seismic protection of high-rise buildings

  • Chang, Chia-Ming;Wang, Zhihao;Spencer, Billie F. Jr.;Chen, Zhengqing
    • Smart Structures and Systems
    • /
    • v.11 no.5
    • /
    • pp.435-451
    • /
    • 2013
  • High-rise buildings are a common feature of urban cities around the world. These flexible structures frequently exhibit large vibration due to strong winds and earthquakes. Structural control has been employed as an effective means to mitigate excessive responses; however, structural control mechanisms that can be used in tall buildings are limited primarily to mass and liquid dampers. An attractive alternative can be found in outrigger damping systems, where the bending deformation of the building is transformed into shear deformation across dampers placed between the outrigger and the perimeter columns. The outrigger system provides additional damping that can reduce structural responses, such as the floor displacements and accelerations. This paper investigates the potential of using smart dampers, specifically magnetorheological (MR) fluid dampers, in the outrigger system. First, a high-rise building is modeled to portray the St. Francis Shangri-La Place in Philippines. The optimal performance of the outrigger damping system for mitigation of seismic responses in terms of damper size and location also is subsequently evaluated. The efficacy of the semi-active damped outrigger system is finally verified through numerical simulation.

A Development of Active Monitoring and Approach Alarm System for Marine Buoy Protection and Ship Accident Prevention based on Trail Cameras and AIS (해상 부이 보호 및 선박 사고 예방을 위한 트레일 카메라-AIS 연계형 능동감시 및 접근경보 시스템 개발)

  • Hwang, Hun-Gyu;Kim, Bae-Sung;Kim, Hyen-Woo;Gang, Yong-Soo;Kim, Dae-Han
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.1021-1029
    • /
    • 2018
  • The marine buoys are operated in various domains, which are navigation route and danger maker, weather and environment monitoring, military strategical element, etc. If the marine buoy is damaged, there consumes many cost and time for recovery or replacement, because of severe environmental condition, and causes a risk possibility of secondary accident. In this paper, we developed an active monitoring and approach alarm providing system using trail cameras and AIS for protection for the marine buoys. To do this, we analyzed existing researches and similar systems, extracted requirements for enhancement, and designed the system architecture that applied the enhanced elements. The main considerations of system enhancement are: integration of AIS and trail cameras, adopting of phased alarm technique by approaching ships, applying of selective communication module, conducting the image processing of ships for providing alarm, and applying thermal cameras. After that, we developed the system using designed architecture and verified effectiveness of the system based on laboratory or field-level tests.

Analysis results of the Anti-islanding Function for PV-AF System (액티브 필터기능을 갖는 3상 태양광 발전시스템의 단독운전 방지기능의 분석)

  • Kim, Gyeong-Hun;Seo, Hyo-Ryong;Jang, Seong-Jae;Park, Sang-Soo;Park, Min-Won;Yu, In-Keun;Jeon, Jin-Hong;Kim, Seul-Ki;Jo, Chang-Hee;Ahn, Jong-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1085-1086
    • /
    • 2008
  • Shunt active filter can compensate harmonic current of utility results from non-linear loads such as rectifiers, cycloconverters and arc furnaces. It has the same structure as photovoltaic(PV) generation system. So, It was proposed the system that generates PV power and also has active filter function. It is called PV-AF(Photovoltaic and Active Filter) power generation system. Islanding can be occurred in an inverter based dispersed generation system, when the system disconnected from utility and loads are entirely supplied by PV system only. Islanding may result in interference to grid protection devices, equipment damage, and even personnel safety hazards. Therefore, islanding has to be detected and protected. The conventional anti-islanding methods have NDZ(None-Detection Zone) or power quality degradation. But PV-AF power generation system has the function of not only shunt active filter but also anti-islanding method without NDZ. In this paper, a novel anti-islanding method for PV-AF system is proposed and analysed in detail.

  • PDF