The Study of Physical Properties of Fly Ash Concrete Using Activator (자극제를 사용한 플라이애쉬 콘크리트의 물리적 특성에 관한 연구)

  • Park, Jong-Ho;Kim, Jung-Bin;Won, Eun-Mi;Park, Bong-Soon;Lee, Joung-Ah;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.565-568
    • /
    • 2008
  • Because of low early compressive strength, the usage of fly ash is subject to restriction in comparison with blast-furnace slag powder. Therefore, high amount of fly ash is reclaimed in landfill in face of better economical efficiency and more production. In this paper, the primary aim is to determine to what the basic material characteristics of fly ash concrete is affected by activator, the second aim is to check a possibility of increase in fly ash application. This study show that compared with fly ash concrete using general admixture, fly ash concrete using activator have higher early compressive strength under similar slump, air content, loss. If additional study will inspect performance of activator in various factor, expansion of application of fly ash concrete using activator can be possible.

  • PDF

Luminescent Properties of LaBO3:RE3+ (RE=Tb, Ce) Phosphors for White Light Emitting Diodes

  • Cho, Shinho
    • Current Photovoltaic Research
    • /
    • v.2 no.2
    • /
    • pp.53-58
    • /
    • 2014
  • $Tb^{3+}$ - or $Ce^{3+}$-doped $LaBO_3$ phosphors were synthesized by a solid-state reaction process with different concentrations of activator ions. The XRD spectra showed the monoclinic $LaBO_3$ pattern with the main peak occurring at (014) plane, irrespective of the kind of activator ions. The crystallite size was determined by using the Scherrer formula, and the maximum was obtained with an activator concentration of 0.05 mol for both phosphors. The emission spectra of $LaBO_3$ phosphors doped with $Tb^{3+}$ ions under excitation at 269 nm exhibited three major emission bands at 488, 544, and 587 nm. The strongest emission was green at 544 nm owing to the $^5D_4-^7F_5$ transition at a $Tb^{3+}$ ion concentration of 0.05 mol. For the $Ce^{3+}$-doped $LaBO_3$ phosphors, one strong blue band centered at 469 nm and weak multipeaks were observed. These results suggest that the optimum green and blue emission can be realized by controlling the concentration and type of activator ions incorporated in the host crystal.

Abridged Region from Escherichia coli Periplasmic Stress Sensor DegS Acts as Plasminogen Activator In Vitro

  • Junpeng, Yan;Ko, Juho;Qi, Yipeng
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.4
    • /
    • pp.594-599
    • /
    • 2007
  • It is well known that the Escherichia coli inner membrane-bound protease DegS is a periplasmic stress sensor for unfolded outer membrane proteins (OMPs). Previous studies have also shown that the outer membrane protease OmpT activates plasminogen in vitro and this may be exploited by bacteria in the course of pathogenesis. However, there has been no research on the plasminogen activation ability of the important periplasmic protein DegS. Accordingly, in this study, the whole-length and truncated degS genes were separately overexpressed in Escherichia coli, the recombinant proteins purified by affinity chromatography, and their plasminogen activator role tested in vitro. The results suggested that the whole-length DegS was able to activate plasminogen on a plasma plate. The truncated form of DegS (residues 80-345), designated ${\Delta}DegS$, also acted as a plasminogen activator, as confirmed by different assays. The serine protease property of ${\Delta}DegS$ was verified based on the complete inhibition of its enzyme activity by PMSF (phenylmethanesulfonyl fluoride). Therefore, the present results indicate that DegS is a plasminogen activator in vitro.

The Study of Quality Improvement of Fly Ash Concrete U sing Activator (자극제를 이용한 플라이애쉬 콘크리트의 품질 향상에 관한 연구)

  • Park, Jong-Ho;Kim, Jung-Bin;Yong, Jeong;Park, Bong-Soon;Lee, Joung-Ah;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.349-350
    • /
    • 2009
  • According to result of this study on quality improvement of fly ash concrete using activator, fly ash concrete using activator was improved compression strength without a change of fresh concrete properties.

  • PDF

Experimental Study on Development of Compressive Strength in Using by Micro-grinding Fly-ash (미분쇄 플라이애쉬를 사용한 모르타르의 압축강도 발현성상에 대한 실험적 연구)

  • 김종협;최광윤;최영화;정재동
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.99-102
    • /
    • 1999
  • In the study, the effect of the replacement content(20, 40, 60, 80%) and particle fineness and the chemical activator of the fly-ash on the flow and strength development of mortar was investigated. We found that the higher raito of the fly-ash replacement produced the lower the mortar strength and the higher fineness of the fly-ash yielded the higher strength. Also, we used Na2SO4 as activator of fly-ash to rise compressive strength mortar. The result as follows: the fly-ash mortar which stimulated by chemical activator, was higher strength development at early than the fly-ash mortar without chemical activator. But in the late age, the result indicated adversely.

  • PDF

Effects of activator treatment on different skeletal patterns in growing class II malocclusion patients (성장기 II급 부정교합자에서 골격 형태에 따른 액티베이터 사용 효과에 관한 연구)

  • Ki, Jun-Hun;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.29-43
    • /
    • 2007
  • Objective: To establish proper diagnosis and treatment plan for skeletal Class II malocclusions, some important factors to consider are the patient's skeletal morphology, prognosis as well as the treatment effects. Therefore, the present study analyzed the effects of activator treatment on different skeletal patterns in growing Class II malocclusion patients. Methods: A total of 116 patients (53 boys & 63 girls) in the experimental group were treated with the activator appliance. The experimental group was classified into either hyperdivergent or hypodivergent groups according to articular and genial angles. Results: Patients with hypodivergent growth patterns showed good effects of activator treatment. Conclusion: It seems conceivable that through classifying adolescent Class II malocclusion patients into different skeletal patterns, activator treatment effects may be predicted during the diagnosis and treatment planning stage.

Physical and Mechanical Properties of Non-Cement Porous Concrete with Alkali-Activator Contents (알칼리활성화제 치환율에 따른 무시멘트 다공성 콘크리트의 물리·역학적 특성)

  • Kim, Dong-Hyun;Kim, Chun-Soo;Park, Chan Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.2
    • /
    • pp.59-64
    • /
    • 2013
  • The present study is to evaluate physical and mechanical properties of porous concrete having non cement that mainly causes carbon emission. This study aims to explore eco-friendly concrete technology capable of reducing the amount of carbon emission due to the use of normal cement by substituting it with non cement porous concrete to which alkali-activator and blast-furnace slag powder are impregnated. As experimental variables, 5 %, 6 %, 7 %, 8 %, 9 % and 10 % of alkali-activator were substituted as binders and applied. Testing evaluated in this study were pH value, void ratio, compressive strength and residual compressive strength shown after being immersed in $H_2SO_4$ solution and $Na_2SO_4$ solution. The test results were compared with those tested with the use of porous concrete to which 400 $kg/m^3$ of unit cement amount was applied as binder. In consequence, it was concluded that; as for pH value, it was decreased than was the case in which cement was used, but increased with the more the use of alkali activator; as for void ratio and compressive strength, the mix proportion in which 9 % and 10 % of alkali activator were applied in terms of substitution ratio showed the result similar to the mixture in which 400 $kg/m^3$ of unit cement ratio was applied; and, as for residual compressive strength in the case of being immersed in $H_2SO_4$ solution and $Na_2SO_4$ solution, the compressive strength was increased, thus leading to improved chemical resistance.

Evaluation of growth changes induced by functional appliances in children with Class II malocclusion: Superimposition of lateral cephalograms on stable structures

  • Oh, Eunhye;Ahn, Sug-Joon;Sonnesen, Liselotte
    • The korean journal of orthodontics
    • /
    • v.50 no.3
    • /
    • pp.170-180
    • /
    • 2020
  • Objective: To compare short- and long-term dentoalveolar, skeletal, and rotational changes evaluated by Björk's structural method of superimposition between children with Class II malocclusion treated by functional appliances and untreated matched controls. Methods: Seventy-nine prepubertal or pubertal children (mean age, 11.57 ± 1.40 years) with Class II malocclusion were included. Thirty-four children were treated using an activator with a high-pull headgear (Z-activator), while 28 were treated using an activator without a headgear (E-activator). Seventeen untreated children were included as controls. Lateral cephalograms were obtained before treatment (T1), after functional appliance treatment (T2), and after retention in the postpubertal phase (T3). Changes from T1 to T2 and T1 to T3 were compared between the treated groups and control group using multiple linear regression analysis. Results: Relative to the findings in the control group at T2, the sagittal jaw relationship (subspinale-nasion-pogonion, p < 0.001), maxillary prognathism (sella-nasion-subspinale, p < 0.05), and condylar growth (p < 0.001) exhibited significant improvements in the Z- and E-activator groups, which also showed a significantly increased maxillary incisor retraction (p < 0.001) and decreased overjet (p < 0.001). Only the E-activator group exhibited significant backward rotation of the maxilla at T2 (p < 0.01). The improvements in the sagittal jaw relationship (p < 0.01) and dental relationship (p < 0.001) remained significant at T3. Condylar growth and jaw rotations were not significant at T3. Conclusions: Functional appliance treatment in children with Class II malocclusion can significantly improve the sagittal jaw relationship and dental relationships in the long term.

A Study on Low Residue Flux for Improving Flip Chip Non-wet and Reliability (Flip Chip Non-wet 개선 및 신뢰성 향상을 위한 Low Residue Flux 구현 방안 연구)

  • Lee, Hyunsuk;Kim, Minseok;Kim, Taehoon;Moon, Kiill
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.2
    • /
    • pp.45-50
    • /
    • 2021
  • As the difficulty of flip chip products increases, there is a growing interest in the material of flux, which is safe from the solder wetting and reliability. In the case of no clean flux, there is merit in terms of process efficiency because there is no cleaning process. But Cu migration and delamination can be occurred if the residue remains after the reflow process. In this study, major element materials, solvent and activator, are changed and confirmed effect of non-wet and reliability in the package environment. Stability of materials were secured through storage stability evaluation, and we found out non-wet zero materials through the application of two types of solvent and activator with different boiling point and the increase of activator content. After reliability test, no delamination was found in the plane analysis, which secured the final composition of low residue flux.