• Title/Summary/Keyword: Acryl

Search Result 385, Processing Time 0.021 seconds

Conservation and Reproduction of Cheongpung Buwongun Kim Wumyeong's Funeral Bier (청풍부원군 김우명 상여의 보존 및 복제)

  • Jeong, Jaeung;Huh, Ilkwon;Park, Seungwon;Yi, Yonghee
    • Conservation Science in Museum
    • /
    • v.14
    • /
    • pp.91-113
    • /
    • 2013
  • Cheongpung Buwongun Kim Wu-myeong's Funeral Bier, an important folklore cultural property No.120, possessed by Chuncheon National Museum was donated in 2002 (by Kim Seonggu). It consists of a bier, yoyeo(腰輿), myeongjeongdae(銘旌臺), and manjangdae(輓章臺). It has a high value as the oldest royal bier. The bier which had a resting time in the storage for special exhibition of "The great cultural treasure of Gangwon province" was inspected in September 2012 and colored pigment layer of the wooden part had the risk of peeling off and surface damage of the textile was serious. Therefore, conservation treatment was conducted. In addition, knots and susiks(垂飾) were severely damaged and their exhibition was impossible. Therefore, a reproduction to replace them through a close investigation was made. All parts of the funeral bier were in separation except for the basic furniture. Conservation was made by dividing the parts into wooden parts and textile parts. Yoyeo was reinforced after disassembling bujae from it and then was reassembled. Paraloid B-72 2 wt% (in ethyle acetate), acrylic resin, was applied to the wooden part of the bier in order to reinforce the colored pigment layer with the addition of sodium alginate 2 wt%(in stilled water) and glue 4 wt%(in stilled water). The pollutants on the surface of the textile part were removed (vacuuming) and its creases were smoothed out (steaming). Fat-soluble pollutants were removed using an nonionic surfactant(Saponin, concentration at 0.25 to 0.5 g/𝑙, in de-ionized water). After the disassembly of the yoyeo from the broken wooden, it was bonded with glue (3 wt% for the first gluing, 35 wt% for gluing), and pine wood was used to restore missing parts. In the process of connecting Wongak(雲角), the original metal hinge and nails were reused to complete the assembly.

Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography (인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Jeong, Moon Taek;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.613-621
    • /
    • 2019
  • The purpose of this study is to evaluate the effectiveness of supportive devices which are for minimizing the patient's movement during lower extremity angiography and to verify image quality of phantom by analyzing of Mask image, DSA image and Roadmap image into SNR and CNR. As a result of comparing SNR with CNR of mask image obtained by DSA technique using the phantom alone and phantom placed on the supportive devices, there was no significant difference between about 0~0.06 for SNR and about 0~0.003 for CNR. The study showed about 0.11~0.35 for SNR and 0.016~0.031 for CNR of DSA imaging by DSA technique about only water phantom of the blood vessel model and the water phantom placed on the device. Analyzing SNR and CNR of Roadmap technique about water phantom on the auxiliary device (hardboard paper, pomax, polycarbonate, acrylic) and water phantom alone, there was no significant difference between 0.02~0.05 for SNR and 0.002~0.004 for CNR. In conclusion, there was no significant difference on image quality by using supportive devices made by hardboard paper, pomax, polycarbonate or acryl regardless of whether using supportive devices or not. Supportive devices to minimize of the patient's movement may reduce the total amount of contrast, exam-time, radiation exposure and eliminate risk factors during angiogram. Supportive devices made by hardboard paper can be applied easily during angiogram due to advantages of reasonable price and simple processing. It is considered that will be useful to consider cost efficiency and types of materials and their properties in accordance with purpose and method of the study when the operator makes and uses supportive devices.

Investigation of the 19th~20th century Hat String Materials at the National Folk Museum of Korea: Amber, Tortoise Shell, Plastics, Glass (국립민속박물관 소장 19~20세기 갓끈 재질 조사: 호박, 대모, 플라스틱, 유리를 중심으로)

  • Oh, Joon-Suk;Lee, Sae-Rom;Hwang, Min-Young;Noh, Soo-Jung;Lee, Young-Min;Park, Sung-Hee;Lim, Sung-Hee
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.4
    • /
    • pp.66-83
    • /
    • 2018
  • This article focuses how the materials of hatstrings of the 19th to 20th century gat, the Korean top hat for men among the collections of National Folk Museum of Korea, was transformed after port opening treaties with overseas since 1876. As a result of analyzing the materials of the hatstrings, amber, tortoiseshell, wood and bamboo as the traditional materials were used, and ivory, glass (soda glass, lead glass, alkali mixed glass) and plastics (cellulose nitrate, phenol-formaldehyde, polystyrene, acryl) were newly used for the hatstrings. Bamboo, wood and amber were the most frequently used materials. Bamboo was mainly used for the pipe of hatstring and were combined with beads and central decorations of other materials. This shows the trend of bamboo hatstring according to the simplification of the clothing and the culture by Regent Heungseon Daewongun. Ambers were used in the central decorations and beads and the origin of ambers was baltic amber just like the amber relics found in Korea. Compositions of glass were soda glass and alkali mixed glass which were excavated or handed down in Korea from ancient times to Joseon dynasty. But in the case of lead glass, Na2O was detected and it is considered to be a new type lead glass for crafts which came from overseas after port opening since 1876 because it showed the characteristic that it deviates from the lead glass component found in Korea. Plastics such as cellulose nitrate and phenol-formaldehyde were used as new synthetic materials to replace traditional materials such as tortoiseshell, amber, and coral as in the West. Cracks, crazing, crumbly and yellowing of cellulose nitrate of hatstrings were observed by deterioration. The survey of the materials of the 19th to 20th century hatstrings among the collections of National Folk Museum of Korea showed that the introduction of new materials such as glass and plastics were used to replace natural materials such as tortoiseshell and amber along with the use of traditional materials after port opening since 1876.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF