• Title/Summary/Keyword: Acquisition System

Search Result 3,529, Processing Time 0.03 seconds

The study of improving the accuracy in the 3D data acquisition (3차원 모션 데이터 획득의 성능 향상을 위한 연구)

  • Han, Changho;Oh, Choonsuk;Ryu, Youngkee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.5
    • /
    • pp.205-210
    • /
    • 2008
  • In previous paper, we introduced 3d acquisition system with CCD cameras, but it was not distinguished from other 3d acquisition system with PSD camera. In this paper, we introduce the 3d data acquisition system using by stereo method with two cameras, show the calibration method of two cameras, and present 3d acquisition methods. we tried to improve the accuracy of 3d data acquisition and implemented the proposed methods. According to the result, we found that the proposed algorithms can boost the accuracy highly against the previous works. The proposed methods are to remove distortion on input images and adjust z axis. We describes the performance in the result.

  • PDF

Performance Analysis of Burst-Format DS-SS Acquisition system Using a Serial-Maximum Likelihood Search- A Modified State Transition diagram Approach (직렬-최대 공차 탐색을 사용한 비스트형 DS-SS 초기 동기 시스템의 성능 분석-수정된 상태 천이도 접근법-)

  • 이독욱;김근묵;황금찬
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.11
    • /
    • pp.855-865
    • /
    • 1991
  • A simple method for analysis of serial search burst-format direct-sequence spread-spectrum (DS-SS) code acquisition system had been recently proposed, and therein, the effect of the code autocorrelation sidelobes on the performance of DS-SS code acquisition system has been assessed [4],[5]. In this paper, a new hybrid scheme which combines the serial search with maximum likelihood search is proposed to eliminate the deleterious effect of code autocorrelation sidelobes, and the performance is analyzed for the additive withe Gaussian noise (AWGN) channels. To analyze the performance of this system, we have generalized the method used in [4],[5] to arbitrary burst-format DS-SS acquisition schemes. The results show that a new hybrid scheme has good immunity against the effect of code autocorrelation sidelobes. Thevalidity of the presented approach has been confirmed form the results of simulation.

  • PDF

Real -Time ECG Signal Acquisition and Processing Using LabVIEW

  • Sharma, Akshay Kumar;Kim, Kyung Ki
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.162-171
    • /
    • 2020
  • The incidences of cardiovascular diseases are rapidly increasing worldwide. The electrocardiogram (ECG) is a test to detect and monitor heart issues via electric signals in the heart. Presently, detecting heart disease in real time is not only possible but also easy using the myDAQ data acquisition device and LabVIEW. Hence, this paper proposes a system that can acquire ECG signals in real time, as well as detect heart abnormalities, and through light-emitting diodes (LEDs) it can simultaneously reveal whether a particular waveform is in range or otherwise. The main hardware components used in the system are the myDAQ device, Vernier adapter, and ECG sensor, which are connected to ECG monitoring electrodes for data acquisition from the human body, while further processing is accomplished using the LabVIEW software. In the Results section, the proposed system is compared with some other studies based on the features detected. This system is tested on 10 randomly selected people, and the results are presented in the Simulation Results section.

Design of High-Frequency Data Acquisition System for Combustor Combustion Test Facility (연소기 연소시험설비 고주파 계측 시스템 설계)

  • Ahn, Kyu-Bok;Kang, Dong-Hyuk;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.461-464
    • /
    • 2012
  • The high-frequency data acquisition system of the rocket engine test facility has been updated to perform hot-firing tests of 7 ton-class liquid rocket engine combustion chambers which will be used for the third stage of the Korea space launch vehicle II. The paper deals with the design of the updated high-frequency data acquisition system and explains its main functions.

  • PDF

The Development of Outdoor Augmented Reality System by GPS (GPS를 이용한 옥외용 증강현실 시스템 개발)

  • Choi, T.J.;Jang, B.T.;Han, S.H.;Kim, J.K.;Hur, W.
    • Proceedings of the IEEK Conference
    • /
    • 2000.06c
    • /
    • pp.153-156
    • /
    • 2000
  • In this paper, we developed an outdoor augmented reality system which has remote real scenes acquisition ability. The real scenes acquisition system consists of Image acquisition system, tracking system, wireless data transceiver and power supply. The tracking system consists of Tans Vector and RT-20 which measures a position and attitude of the CCD camera that attached to the remote control helicopter. Wireless data transceiver system is utilized for data transmission of remote system that of attitude, position information, and real scenes data that acquired by the CCD camera. Maximum propelling power of remote control helicopter is 15Kg, so we used 7.2V li-ion cell as a power supply for system minimize. As the results of experiment, the developing system presented application possibility of remote information acquisition system such as construction simulation & estimation, broadcasting, tour guide.

  • PDF

A Study on Acquisition of Direct Sequence Spread Spectrum Signal Using Non-coherent Digital Correlator (비동기식 디지털 상관기를 이용한 직접부호계열 확산신호의 초기동기에 관한 연구)

  • Lee, Jung Hoon;Lee, Choong Woong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 1987
  • In this paper, the acquisition performance of a receiver that utilizes a non-coherent digital correlator is analyzed. In order to analyze the acquisition performance, the probability density function of a receiver output random variable has been derived approximately. Using this function, the acquisition performance of the coarse acquisition code receiver in a global positioning system is analyzed.

  • PDF

Study to Protocol of PET Acquisition Time for Patient Body Type in PET/CT (PET/CT 검사에서 환자체형에 따른 적정검사 프로토콜에 관한 고찰)

  • Cho, Seok Won;Ham, Joon-Chul;Kang, Chun Goo;Bahn, Young Kag;Lee, Seung Jae;Lim, Han Sang;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.72-77
    • /
    • 2013
  • Purpose: Whole-body PET using radiopharmaceutical is one of the imaging study methods for physiological changes of body. High specificity of the PET-CT examination is used to detect an early stages of cancer and metastatic cancer by imaging a physiological changes. During the imaging process, PET image has been characterized by a relatively low image quality due to its low sensitivity and the acquisition of random and scatter coincidences as well as patients figure. Therefore, the image quality as the changes of the acquisition times of patient weight was evaluated in this study. Materials and Methods: Thirty patients who presented to our hospital were enrolled. They were divided to normal, overweight, and obese group using BMI index, respectively. The patients with a liver disease and diabetes were excluded. $^{18}F-FDG$ was administered to the patients as 5.2 MBq per kg. After an hour from an injection, image acquisition was obtained as List mode in a part of liver in 1 bed. SNR (signal-to-noise ratio) of each groups acquisition times were confirmed from the calculated radiation counts and random fractions. The statistical significance of three groups was confirmed through one-way ANOVA test. On the basis of the counts of 2 minutes on normal group, the SNR of overweight group and obese group were compared. Results: The SNR were increased with loger aquisition time in 3 groups. In the condition of same acquisition time, the SNR had a statistical significance (P<0.05). The SNR were decreased to the normal, overweight, and obese, respectively. Liver activity had no significance difference on each group and RF had the significance differences (P<0.05). On the basis of the counts of 2 minutes on normal group, there were no statistical significance in a three minute acquisitions of overweight group and two minute acquisitions of obese group (P=0.150). Conclusion: In this study, the administrated amount of radiation dose did not adjust as the change of the patients weight. Increasing the acquisition time when the administration of the same amount of dose was able to get a good result of SNR. When the Based 2 minute on normal group, if overweight and obese case the increased acquisition time of 3 minute was able to obtain a similar SNR. On the basis of the normal group, the acquisition times of overweight and obese group were increased to 3 minutes per bed and the SNR were similar to the normal group.

  • PDF

Rapid Acquisition of m-sequence Signals by Sequential Estimation with Flexible Structure (가변구조를 갖는 순차 예측 방법을 이용한 m 계열 신호의 고속 포착)

  • 현광민;박상규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7B
    • /
    • pp.664-672
    • /
    • 2002
  • This paper analyzes a sequential estimator with flexible structure for rapid acquisition of the m-sequence signals. If the received PN chips stored in the estimator's internal registers as initial loading values include one error, this chip with error can be corrected through multiple local PN code generators to achieve high-speed acquisition performance. Hamming distance between regenerated local PN codes from the proposed system and received PN code is compared with given threshold to choose a possible correct path and to declare success of the code acquisition. Using signal flow graph, average acquisition time that depends on detection and false alarm probability is calculated. By modifying generally used matched filter structure for PN code acquisition, the proposed system provides flexible structure and rapid acquisition process.