• Title/Summary/Keyword: Acquisition Rate

Search Result 600, Processing Time 0.022 seconds

A Study on the Promotion of Reliability Test for Imbedded Software of Weapon System (무기체계 내장형 소프트웨어 신뢰성시험 향상방안에 관한 연구)

  • Heo, Kon Yi;Kwon, Kyoug Yong;Kim, Tae Sik
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.11 no.1
    • /
    • pp.67-72
    • /
    • 2015
  • It has been tested for SW reliability in order to prevent the SW error during the development of weapons systems. According to a recent report, defects such as memory leak, buffer overflow, and null deference occur usually in the development stage, but also in the mass production stage. Although it is intended to enhance the SW test and evaluation to prevent SW failures in the development stage, the non-functional problems like syntax errors are not completely revised due to the limitation of the schedule and costs. In addition, SW failure rate are usually fluctuated by the operational environment through SW upgrade in contrast with HW. In this paper, we propose a method to increase SW reliability in the mass production stage of Korean weapon systems.

An Improved Hybrid Canopy-Fuzzy C-Means Clustering Algorithm Based on MapReduce Model

  • Dai, Wei;Yu, Changjun;Jiang, Zilong
    • Journal of Computing Science and Engineering
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • The fuzzy c-means (FCM) is a frequently utilized algorithm at present. Yet, the clustering quality and convergence rate of FCM are determined by the initial cluster centers, and so an improved FCM algorithm based on canopy cluster concept to quickly analyze the dataset has been proposed. Taking advantage of the canopy algorithm for its rapid acquisition of cluster centers, this algorithm regards the cluster results of canopy as the input. In this way, the convergence rate of the FCM algorithm is accelerated. Meanwhile, the MapReduce scheme of the proposed FCM algorithm is designed in a cloud environment. Experimental results demonstrate the hybrid canopy-FCM clustering algorithm processed by MapReduce be endowed with better clustering quality and higher operation speed.

Analysis on Processing Timeline of COMS LHGS Design

  • Bae, Hee-Jin;Koo, In-Hoi;Seo, Seok-Bae;Ahn, Sang-Il;Kim, Eun-Kyou
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.216-219
    • /
    • 2006
  • This paper analyzes on LHGS (LRIT/HRIT Generation Subsystem) processing timeline for COMS LHGS design. The LHGS shall transmit LRIT/HRIT (Low Rate Information Transmission/ High Rate Information Transmission) data to the users within 15 minutes after the end of the image acquisition. So, this paper performs experiment using MTSAT-1R LRIT/HRIT (11 days) and calculates minimum LHGS processing time. Only HRIT FD (Full Disk) image is considered in this paper because data size of HRIT FD image is the largest. As a result of experiment, COMS LHGS should be able to receive MI Level 1B product within 157 seconds at least.

  • PDF

Assessment of a Phase Doppler Anemometry Technique in Dense Droplet Laden Jet

  • Koo, Ja-Ye;Kim, Jong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.7
    • /
    • pp.1083-1094
    • /
    • 2003
  • This study represents an assessment of the phase-Doppler technique to the measurements of dense droplet laden jet. High-pressure injection fuel sprays have been investigated to evaluate the use of the Phase-Doppler anemometry (PDA) technique. The critical issue is the stability of the phase-Doppler anemometry technique for dense droplet laden jet such as Diesel fuel spray in order to insure the results from the drop size and velocity measurements are repeatable, consistent, and physically realistic because the validation rate of experimental data is very low due to the thick optical density. The effect of shift frequency is minor, however, the photomultiplier tube (PMT) voltage setting is very sensitive to the data acquisition and noise in dense droplet laden jet. The optimum PMT voltage and shift frequency should be chosen so that the data such as volume flux and drop diameter do not change rapidly.

A new algorithm of pulse generation and detection for UWB communication system (UWB통신 시스템을 위한 새로운 펄스생성 방법 및 수신 알고리즘)

  • 김건수;윤상훈;정정화;이경국
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.242-245
    • /
    • 2003
  • This paper introduces a new algorithm of pulse generation and detection for UWB communication system. The existing UWB systems using Gaussian pulse have some difficulties to cope with bandwidth limitation and frequency transition. Moreover. the system sensitivity to channel noise has made the processes of acquisition and tacking difficult. in this paper, we introduce a new pulse generation method which is able to control the bandwidth and center frequency applying modulation method. thus could improve the detection performance of receiving algorithm. Also, we made a system to search maximum perk by applying the proposed algorithm and consequently could guarantee the correct detection. By the result of simulation, when accumulate 10 times at every 2dB band shifting from 0 to 18dB on AWGN channel, we could confirm the proposed method has 97.4% PDR(Pulse Detection Rate) and 1.868% FAR(False Alarm Rate) performance at 4dB SNR and 15% transmission power threshold level.

  • PDF

A study on the development of high-speed wireless modem using DS/SS DQPSK modulation (직접확산 DQPSK 변조방식을 이용한 고속 무선모뎀의 개발에 관한 연구)

  • 오정훈;김진욱;김기두;장수영
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.11
    • /
    • pp.19-31
    • /
    • 1996
  • Spread spectrum method gurantees good performance in digital communication system under multi-path interference and jamming signals. The purpose of this paper is to develop the wireless modem using DS/SS techinque. The transceiver consists of a spread spectrum DQPSK transmitter and a mtching receiver. The system operates with the chipping rate set to 4 Mcps and the number of chips/symbol at 64, making the data rate 62.5 Kbps using QPSK modilation. The receiver section uses a digital matched filter for fast acquisition of burst signals and uses the comparing the BER of proposed system iwth that of narrow bnd system under various additive white gaussian noises. It is showen that the proposed sysem has better performance than narrow band system. When jamming signals is added to the suggested DS/SS system, we also show that the experimental performance (BER) of the suggested wireless modem is almost same as theroretical performance.

  • PDF

Contrast-Enhanced Magnetic Resonance Imaging at True End-Diastole to Quantify Reproducible Transmural Extent of Myocardial Hyperenhancement

  • 최병욱;최규옥;김영진;정남식;임세중
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.44-44
    • /
    • 2003
  • To determine feasibility of contrast-enhanced MRI (co-MRI) at true end-diastole (ED) free from limitation of time for inversion-recovery and trigger window for quantifying transmural extent of infarction. 대상 및 방법: MRI was performed in 18 patients with myocardial infarction. Cine imaging and co-MRI with same registered slices in short axis were peformed. To allow true ED co-MRI, ECG synchronization should use two RR-intervals for one acquisition of a segment of k-space by setting the heart rate to half that of the true heart rate. Trigger delay time was adjusted to the RR-interval for imaging at ED and to the sum of RR-interval plus the time between R-wave and the end-systole (ES) determined in cine images for imaging at ES.

  • PDF

Contrast-Enhanced Magnetic Resonance Imaging at True End-Diastole to Quantify Reproducible Transmural Extent of Myocardial Hyperenhancement

  • 최병욱;최규옥;김영진;정남식;임세중
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.91-91
    • /
    • 2003
  • To determine feasibility of contrast-enhanced MRI (co-MRI) at true end-diastole (ED) free from limitation of time for inversion-recovery and trigger window for quantifying transmural extent of infarction. 대상 및 방법: MRI was peformed in 18 patients with myocardial infarction. Cine imaging and co-MRI with same registered slices in short axis were performed. To allow true ED co-MRI, ECG synchronization should use two RR-intervals for one acquisition of a segment of k-space by setting the heart rate to half that of the true heart rate. Trigger delay time was adjusted to the RR-interval for imaging at ED and to the sum of RR-interval plus the time between R-wave and the end-systole (ES) determined in cine images for imaging at ES.

  • PDF

A technology of realistic multi-media display and odor recognition using olfactory sensors (후각 센서를 이용한 냄새 인식 및 실감형 멀티미디어 표현 기술)

  • Lee, Hyeon Gu;Rho, Yong Wan
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.6 no.4
    • /
    • pp.33-43
    • /
    • 2010
  • In this paper, we propose a floral scent recognition using odor sensors and a odor display using odor distribution system. Proposed odor recognition has method of correlation coefficient between sensors that select optimal sensors in floral scent recognition system of selective multi-sensors. Proposed floral scent recognition system consists of four module such as floral scent acquisition module, optimal sensor decision module, entropy-based floral scent detection module, and floral scent recognition module. Odor distribution system consists of generation module of distribution information, control module of distribution, output module of distribution. We applied to floral scent recognition for performance evaluation of proposed sensors decision method. As a result, application of proposed method with floral scent recognition obtained recognition rate of 95.67% case of using 16 sensors while applied floral scent recognition system of proposed sensor decision method confirmed recognition rate of 96% using only 8 sensors. Also, we applied to odor display of proposed method and obtained 3.18 thorough MOS experimentation.

A Study on the Precise Measurement of the Performance in the Heating System (발열시스템 열적 성능의 정밀측정에 관한 연구)

  • 최창용;김홍건
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.6
    • /
    • pp.60-67
    • /
    • 2002
  • A precise measurement of field test was performed to estimate the thermal performance of the forced convection electric air heater by experiment. Air temperature, flow rate and electrical power input were measured with the related measurement sensors, and acquisition methods for the measured data were studied to estimate the thermal performance of the tested air heater effectively. To determine the mean air temperature at the flow cross-section, measuring positions were chosen by considering the flow velocity profile and the equally divided cross-sectional area. From the experimental results, thermal efficiency was obtained accurately as an indication of the tested heating system performance.