• Title/Summary/Keyword: Acoustical measurement

Search Result 389, Processing Time 0.034 seconds

A study on the underwater energy harvesting characteristics of a funnel type macro fiber composite energy harvester (수중에서 퍼넬형 macro fiber composite 에너지 하베스터의 에너지 수확 특성)

  • Jongkil Lee;Jinhyo An
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.57-66
    • /
    • 2023
  • In this paper, it was investigated how the amount of energy harvesting will be varied from the FTEH which has inlet area is wider than outer area and attaching cantilever type MFC (Macro Fiber Composite) using by theoretical and experimental approaches. When MFC length increased 50 % vibration displacement also increased 3.5 times. When thickness decreased vibration displacement increased 30.9 times. In underwater tank experiments FTEH with spiral screw, flexible support, vertical direction fabrication cases showed maximum energy harvesting more 5 times than the case of MFC installed horizontally without spiral screws and on rigid supports. When the flow speed of 0.24 m/s FTEH's optimal resistance applied 4,10 kΩ, energy storage in the capacitor was measured 4 ㎼·s during 350 seconds. It was confirmed that the charging energy can be increased by lengthening the capacitor charging time of the large-area MFC installed vertically on the flexible support at high flow speed.

Improvement of evaluation method for impact sound reduction performance of floor coverings (바닥 상부 마감재의 충격음 저감성능에 대한 평가방법 개선)

  • Jin-Yun Chung;Han-Sol Song;Guk-Gon Song;Yong-Jin Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.161-167
    • /
    • 2023
  • Recently, floor impact sound has become a serious social problem in Korea. There is an increasing need to improve floor impact sound performance using floor covering installed on the floor of apartment houses. KS F ISO 717-2 and KS F 2863 require measurement under conditions in which the resilient material is not installed. But most apartment houses in Korea install resilient materials to reduce floor imapct sound. The performance evaluation method of floor covering should provide reduced performance for use by residents of apartment houses with resilient materials. Therefore, this paper proposes a reduction performance evaluation under the conditions in which a resilient material is installed to verify the performance of floor covering.

Evaluation and improvement of external electric blinds through field application (실증 적용을 통한 외부 전동블라인드의 성능 평가 및 개선 방안)

  • Min-Woo Kang;Hee-Dong Lee;Yang-Ki Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.181-188
    • /
    • 2023
  • In a typical living space, windows are directly exposed to the external noise environment. The best way to reduce outside noise is to block it from the outside, not the inside. Exterior blinds for blocking sunlight are commercialized in various ways. However, it has not yet been actively utilized in Korea. In the previous study, an experiment was conducted in an accredited laboratory to verify the sound insulation performance of an external motorized blind manufactured for shading. And it was verified that there is a sound insulation performance of 6 dBA compared to the reduction performance of a general window. In this study, we tried to confirm the reduction performance by applying the sound insulation performance of external electric blinds to windows in actual living spaces. In addition, an improvement plan was sought to increase the effective noise reduction performance. As a result of the measurement, the reduction performance of the external motorized blind itself was insufficient at the level of 1 dBA to 3 dBA. However, additional reduction performance of the 2 dBA level was confirmed by filling the gap between the blind slits.

The Research of the Heavy-Weight Impact Sound Characteristic by Live load Installation on the Source Room (공동주택 음원실 바닥의 하중 설치에 따른 중량충격음 특성에 관한 연구)

  • Kim, Kyoung-Woo;Yang, Kwan-Seop;Sohn, Jang-Yeul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.6
    • /
    • pp.235-242
    • /
    • 2007
  • The test and evaluation of floor impact sound is mainly conducted before move in the residence. Floor impact sound generating is actually the conditions in which a heavy load like a curtain and furniture is installed, the situation before and after move in the residence is different. In this study, we investigate the floor impact sound variations according to the live load installation like furniture in the source room. The vibration acceleration level and floor impact sound level variation were measured before and after live load ($200kg/m^2$) installation in the floor impact sound test building and the field. The difference was not large although the vibration acceleration level and the floor impact sound level were reduced through measurement result of load installation. Resonance frequency was not changed by load installation.

Calculation and Uncertainty Estimation of the Volume of Reverberation Chamber with Indeterminate Form (부정형 잔향실의 체적 산출과 체적 불착도 평가)

  • Suh, Jae-Gap;Suh, Sang-Joon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.8
    • /
    • pp.375-380
    • /
    • 2007
  • A reverberation chamber should be designed and constructed so as to satisfy its purposes and available space. However, it is somewhat difficult to meet the intended design requirements due to various errors from construction process. So, the post-construction measurement of its volume and surface areas is very essential to check the actual volume and volume uncertainty of a reverberation chamber These values should be carefully calculated and accurately estimated since they are used not only to evaluate the acoustic characteristics of building materials but also to calculate uncertainties for other acoustic characteristics. In this work, the method for the calculation and uncertainty estimation of the volume of a reverberation chamber is presented. To this end, the coordinates of all corners was measured with Total Station after construction. The results showed that the calculated volume of the measured reverberation chamber differs by 5 % from the design specification. The expanded volume uncertainty was also estimated to be about 2 % of the total calculated volume.

Audio Fingerprint Extraction Method Using Multi-Level Quantization Scheme (다중 레벨 양자화 기법을 적용한 오디오 핑거프린트 추출 방법)

  • Song Won-Sik;Park Man-Soo;Kim Hoi-Rin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.151-158
    • /
    • 2006
  • In this paper, we proposed a new audio fingerprint extraction method, based on Philips' music retrieval algorithm, which uses the energy difference of neighboring filter-bank and probabilistic characteristics of music. Since Philips method uses too many filter-banks in limited frequency band, it may cause audio fingerprints to be highly sensitive to additive noises and to have too high correlation between neighboring bands. The proposed method improves robustness to noises by reducing the number of filter-banks while it maintains the discriminative power by representing the energy difference of bands with 2 bits where the quantization levels are determined by probabilistic characteristics. The correlation which exists among 4 different levels in 2 bits is not only utilized in similarity measurement. but also in efficient reduction of searching area. Experiments show that the proposed method is not only more robust to various environmental noises (street, department, car, office, and restaurant), but also takes less time for database search than Philips in the case where music is highly degraded.

A Study on the Relationship Between Apparent Auditory Room Size and Acoustic Preference (공간의 청각적 규모감과 음향적 선호도간의 관계)

  • Jeong Dae-Up
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.191-196
    • /
    • 2006
  • Human tend to rely their information about the size of a space on vision. However, it might be a common experience to perceive a certain difference in spaces without any visual difference, in such spaces as rooms for music performance, multimedia environments with multiple sound sources, and car cabins, where auditory experiences have a certain importance. In the present work, apparent auditory room size was measured at different positions in a room through a series of listening experiments. Also, measurement of room acoustic parameters was carried out and their relationships with perceived auditory room size were analyzed. The results suggest that apparent auditory room sizes were largely dependent on musical clarity, distance between a source and a receiver, and sound pressure level at the listening position. Also, the results from acoustic preference test suggest that smaller apparent room sizes were preferred for listening to orchestral, cello and flute music. The relationship between apparent auditory room size and vocal music was found to be statistically insignificant.

Improvement in Sensitivity by Increasing the Frequency of SAW Sensors for DNA Detection (DNA 측정용 SAW 센서의 주파수 증대에 의한 감도향상)

  • Sakong, Jung-Yul;Kim, Jae-Ho;Lee, Soo-Suk;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.42-47
    • /
    • 2007
  • In this paper. we have studied improvement in sensitivity by increasing the frequency of SAW sensors for detecting the immobilization and hybridization of DNA. The sensor consists of twin SAW delay lines operating at 200MHz, a sensing channel and a reference channel. fabricated on $36^{\circ}$ rotated Y-cut X-propagation $LiTaO_3$ crystals. The optimum concentration of probe and target DNA was decided for the improvement of detection mechanism. and digital syringe pump system was used to reduce the human errors. The hybridization between immobilized probe DNA and target DNA on the gold-coated delay line results in mass loading on the delay line of the sensing channel. Thus, the relative frequency change was monitored in relation to the mass loading. The measurement results showed a good response of the sensor to the DNA hybridization with a maximum sensitivity level up to 0.066ng/m1/Hz.

Selection of Personalized Head Related Transfer Function Using a Binary Search tree (이진 탐색 트리를 이용한 개인화된 머리 전달 함수의 탐색)

  • Lee, Ki-Seung;Lee, Seok-Pil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.5
    • /
    • pp.409-415
    • /
    • 2009
  • The head-related transfer function (HRTF), which has an important role in virtual sound localization has different characteristics across the subjects. Measuring HRTF is very time-consuming and requires a set of specific apparatus. Accordingly, HRTF customization is often employed. In this paper, we propose a method to search an adequate HRTF from a set of the HRTFs. To achieve rapid and reliable customization of HRTF, all HRTFs in the database are partitioned, where a binary search tree was employed. The distortion measurement adopted in HRTF partitioning was determined in a heuristic way, which predicts the differences in perceived sound location well. The DC-Davis CIPIC HRTF database set was used to evaluate the effectiveness of the proposed method. In the listening test, where 10 subjects were participated, the stimuli filtered by the HRTF obtained by the proposed method were closer to those by the personalized HRTF in terms of sound localization. Moreover, performance of the proposed method was shown to be superior to the previous customization method, where the HRFT is selected by using anthropometric data.

Method of Harmonic Magnitude Quantization for Harmonic Coder Using the Straight Line and DCT (Discrete Cosine Transform) (하모닉 코더를 위한 직선과 이산코사인변환 (DCT)을 이용한 하모닉 크기값 (Magnitude) 양자화 기법)

  • Choi, Ji-Wook;Jeong, Gyu-Hyeok;Lee, In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.200-206
    • /
    • 2008
  • This paper presents a method of quantization to extract quantization parameters using the straight-line and DCT (Discrete Cosine Transform) for two splited frequency bands. As the number of harmonic is variable frame to frame, harmonics in low frequency band is oversampled to fix the dimension and straight-lines present a spectral envelope, then the discontinuous points of straight-lines in low frequency is sent to quantizer. Thus, extraction of quantization parameters using the straight-line provides a fixed dimension. Harmonics in high frequency use variable DCT to obtain quantization parameters and this paper proposes a method of quantization combining the straight-line with DCT. The measurement (If proposed method of quantization uses spectral distortion (SD) for spectral magnitudes. As a result, The proposed method of quantization improved 0.3dB in term of SD better than HVXC.