• Title/Summary/Keyword: Acoustic transducer

Search Result 393, Processing Time 0.02 seconds

The analysis of fracture stress using reflection coefficient of surface acoustic wave (탄성표면파의 반사계수를 이용한 파괴응력의 해석)

  • Shin, J.S.;Kim, J.K.;Jun, K.S.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.13-18
    • /
    • 1991
  • In this study, the analysis technique of fracture stress using the reflection coefficient of SAW reflected from a brittle solid with surface crack has been studied. Fracture stress of brittle solid with surface crack has been obtained by the function of the critical stress intensity factor and the maximum normalized stress intensity factor of the crack in the body. And the maximum normalized stress intensity factor of a surface crack can be inferred from a measurement of reflection coefficient of SAW. In experiment, the surface cracks ranging from 0.5mm to 0.9mm in crack depth has been made at the center of each Pyrex disc, and the SAW wedge transducer has been set up for the pitch-catch mode. It has been compared the theoretical values of the fracture stress calculated from the reflection coefficient of SAW with the values of the fracture stress measured from UTM.

  • PDF

Development of Ultrasonic Transducer System for Wireless Power Transfer Part 1 : Transmitter Development (무선 전력전송을 위한 초음파 트랜스듀서 시스템 개발 Part 1: 송신소자 개발)

  • Youm, Woo-Sub;Hwang, Gunn;Yang, Woo-Seok;Lee, Sung-Q
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.9
    • /
    • pp.845-852
    • /
    • 2012
  • Recently, wireless power transfer technology is ready to be commercialized in consumer electronics. It draws attention from not only experts but also public because of its convenience and huge market. However, previous technologies such as magnetic resonance and induction coupling have limited applications because of its short transfer distance compared to device size and magnetic intensity limitation on the safety of body exposure. As an alternative, ultrasonic wireless power transfer technology is proposed. The ultrasonic wireless power transfer system is composed of transmitter which converts electrical energy to ultrasonic energy and receiver which converts the ultrasonic energy to the electrical energy again. This paper is focused on the development of high energy conversion efficiency of ultrasonic transmitter. Optimal transfer frequency is calculated based on the acoustic radiation and damping effect. The transmitter is designed through numerical analysis, and is manufactured to match the optimal transfer frequency with the size of 100 mm diameter, 12.2 mm thickness plate. The energy conversion efficiency of about 13.6 % at 2 m distance is obtained, experimentally. This result is quite high considered with the device size and the power transfering distance.

Development of ultrasonic transducer system for wireless power transfer Part 1: Transmitter development (무선 전력전송을 위한 초음파 트랜스듀서 시스템 개발 Part 1: 송신소자 개발)

  • Youm, Woo-Sub;Hwang, Gunn;Lee, Sung-Q
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.771-776
    • /
    • 2012
  • Recently, wireless power transfer technology is ready to be commercialized in consumer electronics. It draws attention of not only experts but also public because of its convenience and huge market. However, previous technologies such as magnetic resonance and induction coupling have limited applications because of its short transfer distance compared to device size and magnetic intensity limitation for the safety of body exposure. As an alternative, ultrasonic wireless power transfer technology is proposed. The ultrasonic wireless power transfer system is composed of transmitter which converts electrical energy to ultrasonic energy and receiver which converts the ultrasonic energy to the electrical energy again. This paper is focused on the development of high energy conversion efficiency of ultrasonic transmitter. Optimal transfer frequency is calculated based on the acoustic radiation and damping effect. The transmitter is designed through numerical analysis, and is manufactured to match the optimal transfer frequency with the size of 100mm diameter, 12.2 mm thickness plate. The energy conversion efficiency of about 13.6% at 2m distance is obtained, experimentally. This result is quite high considered with the device size and the power transfer distance.

  • PDF

A study on the multi-point signal detection, using Passive band-pass filter in FBG Hydrophone (FBG(Fiber Bragg Grating) Hydrophone에서 Passive Band-Pass Filter를 사용한 다중점 신호 검출에 관한 연구)

  • Kim, Kyung-Bok;Kwack, Kea-Dal
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.307-315
    • /
    • 2000
  • To set up the arrays system of FBG(Fiber Bragg Grating) Hydrophone sensor and realize the multi-point signal detection for the wide scope underwater, using WDM(Wavelength Division Multiplexing) method and Passive band-pass filter system, underwater acoustic signal detection of the newly designed two FBG Transducers is successfully experimented. As a result of the experiment, it was possible each signal with different frequent signals is detected for the multi-point up to 1.3KHz in underwater. We can, therefore, prove the possibility on the system design of Hydrophone sensor arrays, using the newly made FBG Transducers.

  • PDF

Finite Element Modeling of a Piezoelectric Sensor Embedded in a Fluid-loaded Plate (유체와 접한 판재에 박힌 압전센서의 유한요소 모델링)

  • Kim, Jae-Hwan
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.65-70
    • /
    • 1996
  • The sensor response of a piezoelectric transducer embedded in a fluid loaded structure is modeled using a hybrid numerical approach. The structure is excited by an obliquely incident acoustic wave. Finite element modeling in the structure and fluid surrounding the transducer region, is used and a plane wave representation is exploited to match the displacement field at the mathematical boundary. On this boundary, continuity of field derivatives is enforced by using a penalty factor and to further achieve transparency at the mathematical boundary, drilling degrees of freedom (d.o.f.) are introduced to ensure continuity of all derivatives. Numerical results are presented for the sensor response and it is found that the sensor at that location is not only non-intrusive but also sensitive to the characteristic of the structure.

  • PDF

An Analysis on the Resolution of Tomographic Images in STAM (STAM 토모그라픽 영상의 분해능 해석)

  • Hwang, Ki-Hwan;Ko, Dae-Sik;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.33-38
    • /
    • 1997
  • In this paper, we analyzed the resolution of tomographic images which can be obtained with Scanning Tomographic Acoustic Microscope(STAM) utilizing the acousto-optic effect. To realize this, lateral and depth resolutions of both ultrasonic transducer and specimen rotating device are obtained by using BFP tomographic reconstruction algorithm. Simulation results show that both rotating devices have a good depth resolution of $1.5{\lambda}$. For the lateral resolution, the specimen rotating device produces $0.53{\lambda}$ in the x and y directions and the transducer rotating device produces $0.56{\lambda}$ and $0.70{\lambda}$ in the x and y directions respectively. These results imply that the specimen rotating device is more suitable for STAM system construction.

  • PDF

Analysis of the Radiation Pattern of Conformal Array Transducers (곡면 배열 트랜스듀서의 방사 특성 해석)

  • Kim, Hoe-Yong;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.7
    • /
    • pp.431-438
    • /
    • 2010
  • The radiation pattern of conformal transducers installed on a curved surface is likely to be complicated depending on the array pattern on the curved surface. In this research, the acoustic sources constituting a conformal transducer are arrayed in equi-angle, equi-interval, and geodesic dome forms, and the radiation pattern function of each of the array geometries has been derived, and therewith the radiation pattern has been analyzed for each array geometry. Based on the analysis result, we have determined the equi-interval array geometry that provides the widest beam width with the lowest side lobe level among the three array geometries. Results of the present work are expected to be utilized to the design of conformal transducer structures.

A new transmission-line model for multi-layered PZT ultrasonic transducer (다층 PZT 초음파 트랜스듀서에 대한 새로운 전송선로형 등가회로의 제안)

  • Kim, Moo-Joon;Ha, Kang-Lyeol;Kim, Sung-Boo;Lee, Jong-Kyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.29-37
    • /
    • 1995
  • A resonant frequency of piezoelectric transducer depends remarkably on the electric impedance connected to the vibrator. In this paper, using this effect of frequency controllable two layered PZT ultrasonic transducer is designed and its acoustic characteristics are analyzed by a new transmission model equivalent circuit. The theoretical and the experimental results of the electric impedance effect on the resonant frequency variation were compared and both results showed a good consistency each other. The resonant frequency has been controlled continuously in the wide frequency range of 180kHz~580kHz and the effective attenuations were less than 7dB in the frequency range of 330kHz~470kHz.

  • PDF

Development and Application of Phased Array System for Defect Imaging in Plate-like Structures (평판 구조물의 영상화를 위한 위상 배열 시스템 개발 및 응용)

  • Lee, Joo Kyung;Kwon, Young Eui;Lee, Heung Son;Seung, Hong Min;Kim, Ki Yeon;Lee, Jun Kyu;Kim, Hoe Woong;Lee, Ho Cheol;Kim, Yoon Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.2
    • /
    • pp.123-130
    • /
    • 2014
  • An ultrasonic magnetostrictive transducer-based phased-array system for imaging defects in plate structures is newly proposed. In that most ultrasonic phased array systems rely on piezoelectric transducers or electromagnetic acoustic transducers, this system has its own unique feature of employing magnetostrictive transducers. Interest in using a phased array system using magnetostrictive transducers has been recently reported for pipe inspection but no such system has been developed for plate inspection. In this investigation, we aim to propose a phased array system using OL-MPTs (Omnidirectional Lamb wave Magnetostrictive Patch Transducers) for plate inspection. The developed system consists of a multi-channel function generator, power amplifiers, preamplifiers and a data acquisition unit. In the process of its development, each of the units must be checked and in doing so, we suggest types of ultrasonic wave experiments that should be carried out. Finally, the phased system using a transducer array composed of eight OL-MPTs is newly configured and is applied for actual crack detection experiments.

Distribution patterns of the Japanese common squid, Todarodes pacificus attracted around the luring lamp on the jigging boat (채낚기 집어등 어선 주변에 유집된 살오징어, Todarodes pacificus의 분포 패턴)

  • BAE, Jae-Hyun;LEE, Kyounghoon;JO, Hyeon-Jeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.3
    • /
    • pp.276-280
    • /
    • 2016
  • This study investigated luring distributions by water layer of common squid which were targeted by angling fishing vessels equipped with LED and metal-halide lamps using a scientific echosounder with a 120 kHz frequency in order to develop energy-effective underwater fish aggregation devices. In the analysis, angles of a transducer were changed from $0^{\circ}$ to $45^{\circ}$ and were rotated every $10^{\circ}$ horizontally. It was shown that common squid were densely distributed from the surface to 40 m and they were also distributed in directions of $10^{\circ}{\sim}+30^{\circ}$, $-30^{\circ}{\sim}-60^{\circ}$, and $-120^{\circ}{\sim}-130^{\circ}$with the head of vessel as the center. Comparative results of angles of transducer on acoustical densities of common squid distributing in 21~40 m water depth showed an average $101.8m^2/nm^2$ in vertical direction of $0^{\circ}$, $12.3m^2/nm^2$ in angle of $30^{\circ}$, and $42.4m^2/nm^2$ in angle of $45^{\circ}$, respectively. It implied that more considerations on acoustic scattering strength by incidence angle direction of the transducer and swimming oriental angle direction of common squid would be required.