• 제목/요약/키워드: Acoustic standards

검색결과 126건 처리시간 0.023초

Audiometric Calibration of Aural Acoustic Immittance Instrument: A Review of Acoustic Immittance Instrument's Calibration

  • Kim, Jin-Dong
    • 대한의생명과학회지
    • /
    • 제22권4호
    • /
    • pp.115-126
    • /
    • 2016
  • Audiometric calibration is a prerequisite for securing the reliability of audiometric test results by checking the internal consistency of the relevant instrument. The purpose of this review is to help instrument operators understand the calibration procedure of aural acoustic immittance instrument which is frequently used for objective assessment. By referring to the latest international standards and the national standards relevant to the aural acoustic immittance instrument, the following parameters will be reviewed: 1) introduction of performance characteristics, 2) detailed procedure of the calibration method. According to the newest international and national standards [IEC 60645-5 (2004), ANSI S3.39-1987 (R2012)], the aural acoustic immittance instrument basically includes six components: 1) calibration cavity, 2) acoustic immittance analysis system, 3) probe assembly/unit and signal, 4) pneumatic air-pressure pump system, 5) acoustic reflex activator system and 6) tympanogram and acoustic reflex plotting system, each of these components should meet set standards. The result of behavioral hearing tests is influenced by various complex factors including the examinee's cooperation, background noise of the examination room, measurement method, skill level of the audiologist and calibration status, but the objective hearing tests is more influenced by the calibration status of the instrument than any other factors. The audiologist should take full responsibility for the reliability of the hearing test result, so he/she should carry out the calibration check and adjustments of aural acoustic immittance instrument periodically and maintain the instrument continuously by referring to the newest standards and the manufacturer's instruction manual.

바이오센서 개발을 위한 음향 브래그 반사층을 가지는 체적탄성파 공진기의 공진특성 분석 (Analysis of Resonance Characteristics of Bulk Acoustic Resonator with Acoustic Bragg Reflector for Biosensor Development)

  • 김희영;김기복;하태훈;김용일;이진민;김만수
    • Journal of Biosystems Engineering
    • /
    • 제34권4호
    • /
    • pp.260-268
    • /
    • 2009
  • As a basic study to develop a high sensitive biosensor using film bulk acoustic resonator, the mathematical model for analyzing the resonance characteristics of bulk acoustic resonator with acoustic Bragg reflectors was investigated. The simulation results due to the number of acoustic Bragg reflectors with low and high acoustic impedance materials were compared with the experimental results for 1, 2.25 and 5 MHz of PZT based bulk acoustic resonators with various acoustic Bragg reflectors. At the fabricated bulk acoustic resonator with an odd number of acoustic Bragg reflectors, low and high acoustic impedance materials in sequence under the bottom electrode showed better resonance characteristics than even number of acoustic Bragg reflectors. The changes of resonance frequencies due to the increase of number of acoustic Bragg reflectors by simulation and experiment, respectively showed approximately similar tendency but some differences in input impedance between the experiment and simulation were found. The derived mathematical model for describing the resonance characteristics of the bulk acoustic resonator with acoustic Bragg reflector will be available for analyzing the design parameters for development of biosensor using bulk acoustic resonator.

전기-음향 방사컨덕턴스를 이용한 치료용 초음파 자극기의 음향출력 예측 (The Acoustic Output Estimation for Therapeutic Ultrasound Equipment using Electro-Acoustic Radiation Conductance)

  • 윤용현;조문재;김용태;이명호
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.264-269
    • /
    • 2011
  • To increase therapeutic efficiency and biological safety, it is important to precision control of acoustic output for therapeutic ultrasound equipment. In this paper, the electro-acoustic radiation conductance, one of electroacoustic characteristics of therapeutic ultrasound equipment, was measured by the radiation force balance method according to IEC 61161 standards and the acoustic output was estimated using the electro-acoustic radiation conductance. The estimation of acoustic output was conducted to continuous wave mode and pulse wave mode of duty cycle between 20% and 80%. The differences between prediction values and measurement results are within 5% of measurement uncertainty, which is a reasonably good agreement. The results show that acoustic output controlled by electro-acoustic radiation conductance was found to be an effective method.

초음파 영상 진단기용 선형 어레이 변환기의 채널별 음향파워 측정 (Measurement of Acoustic Power Radiating from Each Channel of Linear Array Transducer for Diagnostic Ultrasonic Imaging System)

  • 윤용현;조문재;김용태;이명호
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 추계학술발표대회논문집 제23권 2호
    • /
    • pp.351-352
    • /
    • 2004
  • 본 논문에서는 초음파 영상 진단기용 선형어레이 변환기를 장착할 수 있는 수조 와 128 채널의 스위칭 회로를 제작하여 변환기의 각 채널별 음향파워를 측정하였다. 실험은 128 채널 중 하나의 채널이 불량인 어레이 프로브를 대상으로 수행되었다. 측정 결과, 불량 채널의 음향 파워가 다른 채널에 비해 현저히 작게 나타남을 확인하였다.

  • PDF

펨토초 레이저 유발 shock 형성 및 그 응용 (Femtosecond laser induced shock generation and its application)

  • 정세채;이흥순;시두;문혜영
    • 한국레이저가공학회지
    • /
    • 제17권4호
    • /
    • pp.1-6
    • /
    • 2014
  • Femtosecond laser induced shock generation in water and vitreous humor of enucleated porcine eyeball was investigated. When focusing the femtosecond laser into the liquid mediums, the acoustic waves with a frequency of about 15.6kHz could be observed by using wide-band microphone. The amplitude of the acoustic signals from water has attained a maximum under a laser power of about 5mW. Further increment of the power results in a decrement of the acoustic signals due to nonlinear optical process including filamentation of laser beam. We have further investigated the effect of femtosecond laser induced acoustic waves by applying the laser pulse into enucleated porcine eyeball. The comparative studies on both healthy and diseased eyeballs led us propose that the femtosecond laser pulses could be utilized as a novel tools for treatment of partially detached retina layers from their choroid structures.

  • PDF

국내 교육시설의 음향기준 제정의 필요성 제고 (Towards better acoustic conditions in school buildings in Korea-a need for Korean standard for classroom acoustics)

  • 최영지
    • 한국음향학회지
    • /
    • 제42권2호
    • /
    • pp.113-123
    • /
    • 2023
  • 본 논문에서는 국내 초·중·고 및 대학교 학습공간의 음향 상태에 관해 설명하고 국내 교육시설의 음향 기준 제정의 필요성을 제시하였다. 여러 나라의 학교시설 내 다양한 학습공간에서 요구되는 배경소음, 잔향시간, 그리고 차음 설계의 음향 기준을 이해하기 위해 학교시설 음향설계기준 및 지침을 소개하였다. 국내 초·중·고 및 대학교 학습공간의 음향 상태를 파악하기 위해 현장 측정 결과를 바탕으로 하였으며, 그 결과에서는 공석과 만석 상태의 음향 특성, 배경 소음레벨, 그리고 차음성능을 제시하여 비교하였다. 실제 대학 강의 현장에서 좋은 음성 명료도를 성취하기 위한 음향지표 값도 제시하였다.

초음파 열지수 측정용 조직모사 물질의 성능계수 (Performance Parameter of Tissue Mimicking Material measuring Ultrasonic Thermal Index)

  • 김용태;조문재;윤용현;김호철
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 추계학술발표대회논문집 제23권 2호
    • /
    • pp.369-370
    • /
    • 2004
  • 초음파의 조차에 의한 인체내부의 온도상승의 측도로 열지수(thermal index)가 사용되고 있으며, 이는 주파수 및 음향파워에 의존한다. 초음파 조사에 의한 인체내부의 온도상승을 평가하는데 사용되는 재료를 조직 모사 물질이라 한다. 본 논문아사는 단위 음향파워에 대한 온도 변화인 열 감도(thermal sensitivity)를 새로이 정의하였으며, 이 물리량으로 조직모사물질의 성능을 평가 할 수 있다는 것을 제안하고자 한다.

  • PDF

초음파 영상 진단기의 발진모드별 R-TV 고무 내부의 온도변화 분포 (Spatial Distribution of Temperature Change in a R-TV Rubber for Diagnostic Ultrasonic Imaging System)

  • 조문재;김용태;윤용현
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 추계학술발표대회논문집 제23권 2호
    • /
    • pp.349-350
    • /
    • 2004
  • 매질 내부로 전파하는 초음파는 점성손실(viscous loss), 열전도 손실(heat conduction loss) 둥 다양한 상호작용을 통해 흡수되어 열에너지로 변환되기 때문에 매질 내의 온도 변화를 발생시킨다. 본 논문에서는 RTV 고무 내부에 47 개의 열전대를 장착하여 초음파 영상 진단기로부터 발생되는 초음파 음장에 따른 각 열전대의 채널별 온도변화의 측정결과를 제시하였다.

  • PDF

남북한 음향학 전문용어 비교 분석 및 통합안 제시 (Comparative analysis of inter-Korean acoustic terminology and proposal for integration)

  • 김지완
    • 한국음향학회지
    • /
    • 제42권4호
    • /
    • pp.271-284
    • /
    • 2023
  • 본 연구는 IEC 60050-801:1994 국제 표준을 기준으로 남한 산업표준과 북한 국가규격의 음향학 전문용어 431개를 비교 분석하고 통합 알고리즘을 사용하여 남북한 음향학 용어 통합안을 제시하였다. 용어가 완전히 같은 형태인 AA형은 139개(32.3 %), 어문규범의 차이로 인해 표기 형태가 다른 Aa형은 35개(8.1 %), 형태가 완전히 다른 AB유형은 257개(59.6 %)로 확인되었다. 형태적으로 같은 유형의 용어보다 다른 유형의 용어가 2배 이상 많았으나 내용 면에서 대부분 용어는 충분히 이해하고 유추할 수 있는 범위 안에 있었다. 형태가 다른 음향학 전문용어 통합에서는 북한 전문용어가 178개(61 %), 남한 전문용어가 76개(26 %)로 채택되었다. 이와 같은 결과는 북한 전문용어가 고유성이 압도적으로 높았고, 남한 전문용어는 경제성이 상대적으로 높았기 때문이다. 용어 순화를 통한 고유성과 최신 기술 용어의 대중 활용을 높일 수 있는 경제성 기준을 충족하는 음향학 전문용어 통합 체계 구축이 필요하다. 본 연구는 남북한 음향학 전문용어를 최초로 비교하고 통합안 제시에 의의가 있으며 다음과 같은 제언으로 연구 한계를 극복하고자 한다. 첫째, 정부는 남북한 학술 교류 및 표준화 공통 안을 마련할 수 있도록 지원 및 법적인 장치를 마련하고 북한 관련 연구 데이터에 쉽게 접근할 수 있는 연구 환경을 조성해야 한다. 둘째, 음향학 용어 데이터를 남북한이 공유하고 통합 음향학 용어사전을 발간하도록 노력해야 한다. 셋째, 추후 남북이 전문용어 위원회를 함께 발족하여 표준 개정이 동시에 이루어지도록 노력해야 한다.

전자기 음향 공진을 이용한 강선의 표면 미세 결함 탐상 타당성 연구 (Feasibility Study on Surface Microcrack Detection of the Steel Wire Rods Using Electromagnetic Acoustic Resonance)

  • 허태훈;조승현;안봉영;임종수
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.7-13
    • /
    • 2013
  • 철강 생산 제품 중 강선 (steel wire rod)은 제조 과정 중 종방향으로 미세한 표면 결함이 매우 빈번하게 발생하는데 이중 깊이가 수 십 마이크로미터 이상인 결함들은 최종 생산품의 불량을 유발하는 심각한 원인이 되고 있다. 이와 같은 이유로 강선의 제조 단계에서 표면의 미세 결함의 깊이를 평가하는 방법의 개발이 절실히 요구된다. 표면 미세 결함을 평가할 수 있는 여러 가지 방법 중에서, 본 연구에서는, 전자기 음향공진법의 적용 가능성을 고찰하고자 한다. 전자기 음향 공진 (electromagnetic acoustic resonance, EMAR)은 전자기 음향 트랜스듀서 (electromagnetic acoustic transducer, EMAT)을 이용하여 시편의 공진 특성을 측정하는 방법으로서, 대상의 작은 변화에도 민감하게 반응하고 비접촉 측정이 가능하여 현장 적용에 용이하다는 장점이 있다. 전자기 음향 공진 실험을 통하여 표면 미세결함과 잔향특성의 변화를 관찰하여 깊이 약 100 마이크로미터 내외의 결함은 탐상 가능함을 확인하였다.