• Title/Summary/Keyword: Acoustic standards

Search Result 126, Processing Time 0.025 seconds

Audiometric Calibration of Aural Acoustic Immittance Instrument: A Review of Acoustic Immittance Instrument's Calibration

  • Kim, Jin-Dong
    • Biomedical Science Letters
    • /
    • v.22 no.4
    • /
    • pp.115-126
    • /
    • 2016
  • Audiometric calibration is a prerequisite for securing the reliability of audiometric test results by checking the internal consistency of the relevant instrument. The purpose of this review is to help instrument operators understand the calibration procedure of aural acoustic immittance instrument which is frequently used for objective assessment. By referring to the latest international standards and the national standards relevant to the aural acoustic immittance instrument, the following parameters will be reviewed: 1) introduction of performance characteristics, 2) detailed procedure of the calibration method. According to the newest international and national standards [IEC 60645-5 (2004), ANSI S3.39-1987 (R2012)], the aural acoustic immittance instrument basically includes six components: 1) calibration cavity, 2) acoustic immittance analysis system, 3) probe assembly/unit and signal, 4) pneumatic air-pressure pump system, 5) acoustic reflex activator system and 6) tympanogram and acoustic reflex plotting system, each of these components should meet set standards. The result of behavioral hearing tests is influenced by various complex factors including the examinee's cooperation, background noise of the examination room, measurement method, skill level of the audiologist and calibration status, but the objective hearing tests is more influenced by the calibration status of the instrument than any other factors. The audiologist should take full responsibility for the reliability of the hearing test result, so he/she should carry out the calibration check and adjustments of aural acoustic immittance instrument periodically and maintain the instrument continuously by referring to the newest standards and the manufacturer's instruction manual.

Analysis of Resonance Characteristics of Bulk Acoustic Resonator with Acoustic Bragg Reflector for Biosensor Development (바이오센서 개발을 위한 음향 브래그 반사층을 가지는 체적탄성파 공진기의 공진특성 분석)

  • Kim, Hee-Young;Kim, Ki-Bok;Ha, Tae-Hoon;Kim, Yong-Il;Lee, Jin-Min;Kim, Man-Soo
    • Journal of Biosystems Engineering
    • /
    • v.34 no.4
    • /
    • pp.260-268
    • /
    • 2009
  • As a basic study to develop a high sensitive biosensor using film bulk acoustic resonator, the mathematical model for analyzing the resonance characteristics of bulk acoustic resonator with acoustic Bragg reflectors was investigated. The simulation results due to the number of acoustic Bragg reflectors with low and high acoustic impedance materials were compared with the experimental results for 1, 2.25 and 5 MHz of PZT based bulk acoustic resonators with various acoustic Bragg reflectors. At the fabricated bulk acoustic resonator with an odd number of acoustic Bragg reflectors, low and high acoustic impedance materials in sequence under the bottom electrode showed better resonance characteristics than even number of acoustic Bragg reflectors. The changes of resonance frequencies due to the increase of number of acoustic Bragg reflectors by simulation and experiment, respectively showed approximately similar tendency but some differences in input impedance between the experiment and simulation were found. The derived mathematical model for describing the resonance characteristics of the bulk acoustic resonator with acoustic Bragg reflector will be available for analyzing the design parameters for development of biosensor using bulk acoustic resonator.

The Acoustic Output Estimation for Therapeutic Ultrasound Equipment using Electro-Acoustic Radiation Conductance (전기-음향 방사컨덕턴스를 이용한 치료용 초음파 자극기의 음향출력 예측)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.264-269
    • /
    • 2011
  • To increase therapeutic efficiency and biological safety, it is important to precision control of acoustic output for therapeutic ultrasound equipment. In this paper, the electro-acoustic radiation conductance, one of electroacoustic characteristics of therapeutic ultrasound equipment, was measured by the radiation force balance method according to IEC 61161 standards and the acoustic output was estimated using the electro-acoustic radiation conductance. The estimation of acoustic output was conducted to continuous wave mode and pulse wave mode of duty cycle between 20% and 80%. The differences between prediction values and measurement results are within 5% of measurement uncertainty, which is a reasonably good agreement. The results show that acoustic output controlled by electro-acoustic radiation conductance was found to be an effective method.

Measurement of Acoustic Power Radiating from Each Channel of Linear Array Transducer for Diagnostic Ultrasonic Imaging System (초음파 영상 진단기용 선형 어레이 변환기의 채널별 음향파워 측정)

  • Yun Yong Hyeon;Jho Moon Jae;Kim Yong Tae;Lee Myoung Ho
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.351-352
    • /
    • 2004
  • 본 논문에서는 초음파 영상 진단기용 선형어레이 변환기를 장착할 수 있는 수조 와 128 채널의 스위칭 회로를 제작하여 변환기의 각 채널별 음향파워를 측정하였다. 실험은 128 채널 중 하나의 채널이 불량인 어레이 프로브를 대상으로 수행되었다. 측정 결과, 불량 채널의 음향 파워가 다른 채널에 비해 현저히 작게 나타남을 확인하였다.

  • PDF

Femtosecond laser induced shock generation and its application (펨토초 레이저 유발 shock 형성 및 그 응용)

  • Jeoung, Sae Chae;Lee, Heung Soon;Sidhu, M.S.;Moon, Heh-Young
    • Laser Solutions
    • /
    • v.17 no.4
    • /
    • pp.1-6
    • /
    • 2014
  • Femtosecond laser induced shock generation in water and vitreous humor of enucleated porcine eyeball was investigated. When focusing the femtosecond laser into the liquid mediums, the acoustic waves with a frequency of about 15.6kHz could be observed by using wide-band microphone. The amplitude of the acoustic signals from water has attained a maximum under a laser power of about 5mW. Further increment of the power results in a decrement of the acoustic signals due to nonlinear optical process including filamentation of laser beam. We have further investigated the effect of femtosecond laser induced acoustic waves by applying the laser pulse into enucleated porcine eyeball. The comparative studies on both healthy and diseased eyeballs led us propose that the femtosecond laser pulses could be utilized as a novel tools for treatment of partially detached retina layers from their choroid structures.

  • PDF

Towards better acoustic conditions in school buildings in Korea-a need for Korean standard for classroom acoustics (국내 교육시설의 음향기준 제정의 필요성 제고)

  • Young-Ji Choi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.113-123
    • /
    • 2023
  • This paper describes the acoustical conditions of elementary school and high school classrooms as well as university classrooms in Korea and suggests a need for Korean acoustic standards and guidelines for classroom design. Current standards and guidelines of classroom acoustics in several countries were briefly introduced to understand their acoustical performance criteria for background noise levels and reverberation times, and noise isolation design requirements in various types of classrooms. The results of several acoustic survey of domestic classrooms in elementary school, high school, and university were described and compared to provide information of the acoustic characteristics of Korean school classrooms. The survey includes occupied and unoccupied data on the acoustical conditions, noise levels, and noise isolation performance in the classrooms. Acoustical parameter values for achieving 'good' speech intelligibility in active university classrooms were also presented.

Performance Parameter of Tissue Mimicking Material measuring Ultrasonic Thermal Index (초음파 열지수 측정용 조직모사 물질의 성능계수)

  • Kim Yong Tae;Jho Moon Jae;Yun Yong Hyeon;Kim Ho Chul
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.369-370
    • /
    • 2004
  • 초음파의 조차에 의한 인체내부의 온도상승의 측도로 열지수(thermal index)가 사용되고 있으며, 이는 주파수 및 음향파워에 의존한다. 초음파 조사에 의한 인체내부의 온도상승을 평가하는데 사용되는 재료를 조직 모사 물질이라 한다. 본 논문아사는 단위 음향파워에 대한 온도 변화인 열 감도(thermal sensitivity)를 새로이 정의하였으며, 이 물리량으로 조직모사물질의 성능을 평가 할 수 있다는 것을 제안하고자 한다.

  • PDF

Spatial Distribution of Temperature Change in a R-TV Rubber for Diagnostic Ultrasonic Imaging System (초음파 영상 진단기의 발진모드별 R-TV 고무 내부의 온도변화 분포)

  • Jho Moon Jae;Kim Yong Tae;Yun Yong Hyeon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.349-350
    • /
    • 2004
  • 매질 내부로 전파하는 초음파는 점성손실(viscous loss), 열전도 손실(heat conduction loss) 둥 다양한 상호작용을 통해 흡수되어 열에너지로 변환되기 때문에 매질 내의 온도 변화를 발생시킨다. 본 논문에서는 RTV 고무 내부에 47 개의 열전대를 장착하여 초음파 영상 진단기로부터 발생되는 초음파 음장에 따른 각 열전대의 채널별 온도변화의 측정결과를 제시하였다.

  • PDF

Comparative analysis of inter-Korean acoustic terminology and proposal for integration (남북한 음향학 전문용어 비교 분석 및 통합안 제시)

  • Jiwan Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.4
    • /
    • pp.271-284
    • /
    • 2023
  • This study compared 431 acoustic terminology of South Korean industrial standards and North Korean national standards based on IEC 60050-801:1994 international standards. In addition, this study attempted to integrate acoustic terminology between the two Koreas. There were 139 (32.3 %) AA types with exactly the same form of terminology, 35 (8.1 %) Aa types with different spellings due to differences in linguistic norms, and 257 (59.6 %) AB types with completely different forms. Morphologically, there were more than twice as many different types of terminology as the same type. In the integration of acoustic terminology with different forms, 178 (61 %) North Korean terminology and 76 (26 %) South Korean terminology were adopted. we would like to overcome the limitations of this study through the following suggestions. First, the government should support academic exchanges between the two Koreas and encourage the establishment of common standards for acoustic terminology. Second, efforts should be made to share acoustic terminology data between the two Koreas and publish an integrated acoustic terminology dictionary. Third, South and North Korea should jointly launch a terminology committee to make efforts to revise international standards together.

Feasibility Study on Surface Microcrack Detection of the Steel Wire Rods Using Electromagnetic Acoustic Resonance (전자기 음향 공진을 이용한 강선의 표면 미세 결함 탐상 타당성 연구)

  • Heo, Taehoon;Cho, Seung Hyun;Ahn, Bongyoung;Lim, Zhong Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • The surface microcrack over a few tens of micrometers is one of severe problems of a steel wire rod to lead to the failure of the final products, so the method to evaluate crack depth has been required to develop. This work investigates the feasibility of electromagnetic acoustic resonance (EMAR) for this problem. EMAR is the method for measurement of resonant features using electromagnetic acoustic transducer (EMAT). Generally, EMAR is sensitive to small variation of the structures and easy to apply it to the industrial field because of the feature of noncontact measurement. Through several EMAR experiments, the change of the resonant frequencies and attenuation in reverberation has been observed. The results confirms that the surface cracks of around 100 micrometer depth can be detected successfully with the present method.