• Title/Summary/Keyword: Acoustic parameter

Search Result 416, Processing Time 0.028 seconds

Etching of Pt Thin Film for SAW Filter Fabrication (표면탄성파 필터 제작을 위한 Pt 박막 식각)

  • Choi, Yong-Hee;Song, Ho-Young;Park, Se-Geun;Lee, Taek-Joo;O, Beom-Hoan;Lee, Seung-Gol;Lee, El-Hang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.103-107
    • /
    • 2003
  • The inductively coupled plasma(ICP) etching process was selected to fabricate RF Surface Acoustic Wave(SAW) filters and a Pt thin film was sputtered on a $LiTaO_3$ substrate applied to electrode materials to reduce the spurious response and improve the power durability. Steep sidewall pattern was achieved employing $C_4F_8/Ar/Cl_2$ gas chemistry. We investigated an etching mechanism and parameter dependence of the Pt thin film about $C_4F_8$ addition. Sidewall etch angle was about $80^{\circ}$ at the $C_4F_8$ 20% mixing ratio. Fabricated SAW filter is consists of some series and parallel arm SAW resonators which work as impedance elements and show capacitance characteristics at out of the passband. It can be modified for $800{\sim}900\;MHz$ RF filters. External matching circuits were unnecessary.

  • PDF

Deposition of ZnO Thin Films by RF Magnetron Sputtering and Charcaterization of the ZnO thin film SAW filter (RF 마그네트론 스터터링에 의한 ZnO박막증착 및 SAW 필터 특성 분석)

  • Lee, Yong-Ui;Yang, Hyeong-Guk;Kim, Yeong-Jin;Han, Jeong-In;Kim, Hyeong-Jun
    • Korean Journal of Materials Research
    • /
    • v.4 no.7
    • /
    • pp.783-791
    • /
    • 1994
  • Piezoelectric ZnO thin films were deposited on 7059 glass substrate by rf magnetron sputtering. The effects of deposition parameter, such as rf power, gas pressure and $O_{2}$/Ar gas ratio, on the crystallinity and electrical properties of the deposited ZnO thin films were studied. It was found that the deposition rate was higher than the previously reported values. ZnO films were suitable for SAW filter since a standard deviation of XRD (002) peak rocking curve was less than $6^{\circ}$. ZnO thin films, which were deposited at $O_{2}$/Ar ratio larger than 25%, showed high resistance. SAW filter was fabricated using ZnO film, of which thickness was 0.25 of the wavelength of the propatating surface acoustic wave. The measured frequency response was consistent with the calculated one. The SAW filter had center frequency 39.08 MHz, phase velocity 2501 m/sec and insertion loss 29 dB.

  • PDF

Improved Equalization Technique of OFDM Systems Using Block Type Pilot Arrangement (Block Type 파일럿 배치를 적용한 OFDM 시스템의 등화 기법 개선)

  • Kim Whan-Woo;Kim Ji-Heon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.113-120
    • /
    • 2006
  • This paper is concerned with a equalization technique for Orthogonal Frequency Division Multiplexing (OFDM) systems based on a block type pilot arrangement over slow fading channels. The bit rates obtained in underwater channels are relatively modest compared to some other communication channels such as cellular phones or indoor wireless systems. Consequently. the Doppler effect is the important parameter in tracking a channel. In case of a coherent demodulation scheme, the residual mean phase errors due to Doppler frequency may be fatal for the performance of the system. The equalizer could not solely handle mean Doppler shift. To account for the common Doppler effect a phase error tracking loop is used with the frequency equalizer. so that the rotation errors are avoided. Furthermore. simulations show that we can reduce the computational load of the tracking loop with negligible effect on performance.

Acoustic characteristics of speech-language pathologists related to their subjective vocal fatigue (언어재활사의 주관적 음성피로도와 관련된 음향적 특성)

  • Jeon, Hyewon;Kim, Jiyoun;Seong, Cheoljae
    • Phonetics and Speech Sciences
    • /
    • v.14 no.3
    • /
    • pp.87-101
    • /
    • 2022
  • In addition to administering a questionnaire (J-survey), which questions individuals on subjective vocal fatigue, voice samples were collected before and after speech-language pathology sessions from 50 female speech-language pathologists in their 20s and 30s in the Daejeon and Chungnam areas. We identified significant differences in Korean Vocal Fatigue Index scores between the fatigue and non-fatigue groups, with the most prominent differences in sections one and two. Regarding acoustic phonetic characteristics, both groups showed a pattern in which low-frequency band energy was relatively low, and high-frequency band energy was increased after the treatment sessions. This trend was well reflected in the low-to-high ratio of vowels, slope LTAS, energy in the third formant, and energy in the 4,000-8,000 Hz range. A difference between the groups was observed only in the vowel energy of the low-frequency band (0-4,000 Hz) before treatment, with the non-fatigue group having a higher value than the fatigue group. This characteristic could be interpreted as a result of voice abuse and higher muscle tonus caused by long-term voice work. The perturbation parameter and shimmer local was lowered in the non-fatigue group after treatment, and the noise-to-harmonics ratio (NHR) was lowered in both groups following treatment. The decrease in NHR and the fall of shimmer local could be attributed to vocal cord hypertension, but it could be concluded that the effective voice use of speech-language pathologists also contributed to this effect, especially in the non-fatigue group. In the case of the non-fatigue group, the rhamonics-to-noise ratio increased significantly after treatment, indicating that the harmonic structure was more stable after treatment.

A Study on Performance Evaluation of Hidden Markov Network Speech Recognition System (Hidden Markov Network 음성인식 시스템의 성능평가에 관한 연구)

  • 오세진;김광동;노덕규;위석오;송민규;정현열
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.4
    • /
    • pp.30-39
    • /
    • 2003
  • In this paper, we carried out the performance evaluation of HM-Net(Hidden Markov Network) speech recognition system for Korean speech databases. We adopted to construct acoustic models using the HM-Nets modified by HMMs(Hidden Markov Models), which are widely used as the statistical modeling methods. HM-Nets are carried out the state splitting for contextual and temporal domain by PDT-SSS(Phonetic Decision Tree-based Successive State Splitting) algorithm, which is modified the original SSS algorithm. Especially it adopted the phonetic decision tree to effectively express the context information not appear in training speech data on contextual domain state splitting. In case of temporal domain state splitting, to effectively represent information of each phoneme maintenance in the state splitting is carried out, and then the optimal model network of triphone types are constructed by in the parameter. Speech recognition was performed using the one-pass Viterbi beam search algorithm with phone-pair/word-pair grammar for phoneme/word recognition, respectively and using the multi-pass search algorithm with n-gram language models for sentence recognition. The tree-structured lexicon was used in order to decrease the number of nodes by sharing the same prefixes among words. In this paper, the performance evaluation of HM-Net speech recognition system is carried out for various recognition conditions. Through the experiments, we verified that it has very superior recognition performance compared with the previous introduced recognition system.

  • PDF

The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom (N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과)

  • Kim, Yon-Min;Shim, Jae-Goo;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.221-225
    • /
    • 2017
  • To evaluate the performance of ultrasound imaging system, we investigated the change of spatial resolution according to changing sonic velocity change parameter provided by ultrasound equipment. Ultrasound phantom images were obtained using a 3.0 ~ 5.0 MHz convex transducer in an ultrasound diagnostic device used at a medical institution located at Iksan. N-365 multi-purpose ultrasound phantom was used to measure longitudinal distance measurement accuracy and longitudinal and transverse resolution. In the same manner, the sonic velocity of the ultrasound equipment was changed from 1580 m/sec to 1400 m/sec in six steps, and the full width at half maximum(FWHM) was measured using the image J program to determine whether the measured values were different. As a result, lateral resolution was measured from 1.91 mm to 5.3 mm according to the speed change, and the smallest FWHM was 1.91 mm at 1420 m/sec. The axial resolution was measured from 1.03 mm to 1.14 mm according to the speed change, and the smallest FWHM was 1.03 mm at 1400 m/sec. The slower the sound velocity of the ultrasound equipment, the shorter the length of longitudinal measurement.

Voice Onset Time in Patients with Bilateral Vocal Nodules (양측성 성대결절 환자의 발성시작시간(VOT)에 관한 연구)

  • Park, Sun-Young;Kim, Seong-Tae;Kim, Sang-Yoon;Choi, Seung-Ho;Roh, Jong-Lyel;Nam, Soon-Yuhl
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.17 no.2
    • /
    • pp.107-110
    • /
    • 2006
  • Background and Objeetives : There are few studies reported that specifically examined the voice onset time(VOT) in patients with bilateral vocal nodules. The purpose of this study was to study the characteristics of voice onset in patients with bilateral vocal nodules. Materials and Methods : 52 female patients with bilateral vocal nodules were examined, aged from 20 to 54 years, and were compared with 25 normal female control group. All subjects produced five repetitions of the voiceless stops $/p^h,\;t^h\;k^h/$ in vowel context /ai_a/. VOT was measured by the time between the release of the stops and the onset of voicing. Results : VOTs of the voiceless stops $/p^h/\;and\;/t^h/$ in patients with bilateral vocal nodules were significantly shorter than those of normal subjects. VOT of the $/k^h/$ in them was shorter than those of normals, but the difference was not significant. This results showed that VOTs of the voiceless stops in patients with bilateral vocal nodules were shorter than those of normal subjects. Conclusion : The rapid onset of voicing in patients with bilateral vocal nodules might be associated with increased laryngeal muscle tension by hard glottal attacks. We suggest that VOT can be a clinically useful acoustic parameter for evaluating voice in patients with bilateral vocal nodules.

  • PDF

Lamb Wave Technique for Ultrasonic Nonlinear Characterization in Elastic Plates (판재의 초음파 비선형 특성평가를 위한 Lamb Wave 기법)

  • Lee, Tae-Hun;Kim, Chung-Seok;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.458-463
    • /
    • 2010
  • Since the acoustic nonlinearity is sensitive to the minute variation of material properties, the nonlinear ultrasonic technique(NUT) has been considered as a promising method to evaluate the material degradation or fatigue. However, there are certain limitations to apply the conventional NUT using the bulk wave to thin plates. In case of plates, the use of Lamb wave can be considered, however, the propagation characteristics of Lamb wave are completely different with the bulk wave, and thus the separate study for the nonlinearity of Lamb wave is required. For this work, this paper analyzed first the conditions of mode pair suitable for the practical application as well as for the cumulative propagation of quadratic harmonic frequency and summarized the result in for conditions; (1) phase matching, (2) non-zero power flux, (3) group velocity matching, and (4) non-zero out-of-plane displacement. Experimental results in aluminum plates showed that the amplitude of the secondary Lamb wave and nonlinear parameter growed up with increasing propagation distance at the mode pair satisfying the above all conditions and that the ration of nonlinear parameters measured in Al6061-T6 and Al1100-H15 was closed to the ratio of the absolute nonlinear parameters.

Application of Chiu's Two Dimensional Velocity Distribution Equations to Natural Rivers (Chiu가 제안한 2차원 유속분포식의 자연하천 적용성 분석)

  • Lee, Chan-Joo;Seo, Il-Won;Kim, Chang-Wan;Kim, Won
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.12
    • /
    • pp.957-968
    • /
    • 2007
  • It is essential to obtain accurate and highly reliable streamflow data for quantitative management for water resources. Thereafter such real-time streamflow gauging methods as ultrasonic flowmeter and index-velocity are introduced recently. Since these methods calculate flowrate through entire cross-section by measuring partial velocities of it, rational and theoretical basis are necessary for accurate estimation of discharge. The purpose of the present study lies in analysis on the applicability of Chiu#s(1987, 1988) two dimensional velocity distribution equations by applying them to natural rivers and by comparing simulated velocity distributions with observed ones obtained with ADCP. Maximum and mean velocities are calculated from observed data to estimate entropy parameter M. Such isovel shape parameters as h and $\beta_i$ are estimated by object function based on least squares criterion. In case optimized parameters are applied, Chiu#s velocity distributions fairly well simulate observed ones. By using 14 simulated data sets which have relatively high correlation coefficients, properties of parameters are analyzed and h, $\beta_i$ are estimated for velocity-unknown river sections. When estimated parameters are adopted for verification, simulated velocity distributions well reproduce real ones. Finally, calculated discharges display rough agreement with measured data. The results of the present study mean that if parameters related are properly estimated, Chiu#s velocity distribution is likely to reproduce the real one of natural rivers.

Perceptual cues for /o/ and /u/ in Seoul Korean (서울말 /?/와 /?/의 지각특성)

  • Byun, Hi-Gyung
    • Phonetics and Speech Sciences
    • /
    • v.12 no.3
    • /
    • pp.1-14
    • /
    • 2020
  • Previous studies have confirmed that /o/ and /u/ in Seoul Korean are undergoing a merger in the F1/F2 space, especially for female speakers. As a substitute parameter for formants, it is reported that female speakers use phonation (H1-H2) differences to distinguish /o/ from /u/. This study aimed to explore whether H1-H2 values are being used as perceptual cues for /o/-/u/. A perception test was conducted with 35 college students using /o/ and /u/ spoken by 41 females, which overlap considerably in the vowel space. An acoustic analysis of 182 stimuli was also conducted to see if there is any correspondence between production and perception. The identification rate was 89% on average, 86% for /o/, and 91% for /u/. The results confirmed that when /o/ and /u/ cannot be distinguished in the F1/F2 space because they are too close, H1-H2 differences contribute significantly to the separation of the two vowels. However, in perception, this was not the case. H1-H2 values were not significantly involved in the identification process, and the formants (especially F2) were still dominant cues. The study also showed that even though H1-H2 differences are apparent in females' production, males do not use H1-H2 in their production, and both females and males do not use H1-H2 in their perception. It is presumed that H1-H2 has not yet been developed as a perceptual cue for /o/ and /u/.