• Title/Summary/Keyword: Acoustic monitoring

Search Result 482, Processing Time 0.03 seconds

Size estimation of Sperm Whale in the East Sea of Korea using click signals (동해에서 발견된 향고래의 클릭 신호를 이용한 전장 추정)

  • Yoon, Young Geul;Choi, Kang-Hoon;Han, Dong-Gyun;Sohn, Hawsun;Choi, Jee Woong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.6
    • /
    • pp.533-540
    • /
    • 2020
  • A total length of sperm whales can be estimated by measuring the Inter-Pulse Interval(IPI) of their clicks composed by multiple pulses. The IPI is caused by the two-way travel time of the sound transmission in the spermaceti within the whale head. Therefore, the IPI can be used to measure the whale's total length based on allometric relationships between head and body length. In this paper, the click signals recorded in the East Sea, Korea in 2017 were analyzed to estimate the size of sperm whales. The size of sperm whales calculated by the relationship between IPI and body length was 9.9 m to 10.9 m, which is corresponding to the size of an adult female or a juvenile male sperm whale. This non-lethal acoustic method has been demonstrated to accurately estimate the sperm whale size, and can provide useful information for domestic sperm whale monitoring.

Development of a Gateway System Between Underwater and Land Network and Real-Sea performance Test (수중-육상 네트워크 연계용 게이트웨이 부이시스템 개발 및 실 해역 성능 검증)

  • Lee, Jeong-Hee;Park, Jong-Won;Park, Jin-Yeong;Seo, Su-Jin;Lim, Young-Kon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.6
    • /
    • pp.1200-1207
    • /
    • 2015
  • A gateway buoy system connects a underwater network to a terrestrial network, which enables to efficiently monitor the underwater network on a land station. In this paper, we introduce an implemented gateway buoy system which relays gathered data from multiple underwater nodes to a land station in a real time. The gateway buoy hardware system is composed of a underwater acoustic modem system, a radio frequency modem system, and a gateway operating system. in additional, we have implemented a land operating program and a land monitoring program for gateway system and states of underwater network, respectively. We also perform real-sea experiments to verify the performance of the gateway buoy system which real-time monitors underwater network states and gateway system states.

Review on Monitoring Volume Transport through Measurement of Submarine Cable Voltages around Korea (한반도 주변의 해저 케이블 전압측정을 통한 해수수송량 관측)

  • Kim, Yun-Bae;Kim, Young-Ho;Lyu, Sang-Jin;Kim, Kuh;Choi, Byeong-Ho
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.2
    • /
    • pp.73-81
    • /
    • 2004
  • Voltage induced by the Tsushima Current on an abandoned submarine telephone cable has been measured since March 1998 in order to monitor the volume transport through the Korea Strait. Voltage has a good linear relationship with the transport measured by bottom-mounted Acoustic Doppler Current Profilers (ADCPs) along a section spanning the Korea Strait. This paper reviews researches using submarine cables briefly; we introduce the method to measure voltage on submarine cables, present some results focusing on the example of the Korea Strait, and mention the future prospect to use other submarine cables around Korea.

Voice Changes in Women Treated for Endometriosis (자궁 내막증으로 치료 받은 여성들의 음성 변화)

  • 서민철;주준범;남순열
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.11 no.1
    • /
    • pp.46-50
    • /
    • 2000
  • Background and Objectives : Hormonal treatments which have an androgenic effect have the potential to cause vocal changes. The changes in vocal fold structure and voice quality are considered to be irreversible. To date, studies have documeted subjective vocal changes or documented single cases without detailed, baseline voice assessments. Materials and Methods : We have performed objective voice analyses of 20 women who were treated with androgenic hormones for endometriosis and compared the results with those of normal control women. Results : The averages of fundamental frequency were 194.7${\pm}$28.2 in study group, 207.0${\pm}$14.1 in control group. The means of closed quotient which were measured with electroglottography were 45.13${\pm}$2.06 in study group, 45.1${\pm}$3.03 in control group. Results of acoustic analysis are as follows. The averages of jitter were 0.95${\pm}$0.46 in study group, 1.10${\pm}$0.65 in control group. The means of shimmer were 2.44${\pm}$0.60 in study group, 2.32${\pm}$1.09 in control group. The averages of noise to harmonic ratio were 0.13${\pm}$0.028 in study group, 0.15$\pm$0.18 in control group. Conclusion : Although there were no statistically meaningful differences between the two groups, we could detect the masculinizing tendency of the therapeutic hormones of endomentriosiss(lowering of fundamental frequency). Given the availability of objective voice assessments today and the continued use of these potent hormones, comprehensive voice assessment and vocal monitoring would appear vital for women commencing hormonal treatment.

  • PDF

Color Doppler Ultrasonographic Evaluation in Observing the Affects of $Osteoset^{(R)}$ on Radial Defects in Beagle Dogs (개에서 $Osteoset^{(R)}$의 요골 결손부 충진에 대한 색도플러초음파검사의 유용성 평가)

  • Jeon, Jong-Hoon;Seong, Yun-Sang;Eom, Ki-Dong;Kim, Jae-Hoon;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This study is conducted to compare ultrasonographs with plain radiographs in monitoring bone regeneration during reconstruction of critical sized radial defects in dogs. A 15 mm bony defect was taken on each of the eight dog's radius using an electrical saw and an external fixator was applied. The experimental groups were divided into non-treated group(group 1) and $Osteoset^{(R)}$-treated group(group 2). Each fracture site was evaluated using plain radiography and ultrasonography. Radiographic callus formation occurred after $11.50{\pm}1.12$ days in group 1 and $11.50{\pm}0.5$ days in group 2. Neovascularized flow signal could be seen $6.50{\pm}1.5$ days and the vascular signal disappeared after $45.00{\pm}6.16$ days after operation in group 1. Neovascularized flow signal was observed $6.75{\pm}1.78$ days and vascular signal disappeared $23.25{\pm}3.03$ days after surgery which was caused by acoustic shadowing in group 2. Early stages of regeneration were observed more clearly with color Doppler ultrasonography than with plain radiography. Also from the results it is concluded that color Doppler ultrasonography are useful in observing initial stages of bone repair.

A Study on the Development of the Acoustic Absorption Well of the Cruise Yacht (크루즈요트의 기관실 소음 차단용 차음벽 개발에 관한 연구)

  • Yu, Young-Hun;Yi, Jong-Keun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.109-113
    • /
    • 2007
  • Yacht have an high powered main engine relatively light hull, so the noise generated from the engine have a bad influence upon the crew and passenger. Recently, cruise yacht is made an attempt by domestic production skill, however the insulation skill of the noise made by the main engine is not satisfy the real purchasing power of the buyer. Like this, yacht cabin's noise level is becoming the barometer to decide the purchase. the method to insufficient. However, if we use the skill of the monitoring equipment and the genetic algorithm system, the circumference of the main engine can be enclosed by an high quality absorbtion wall and the noise levels of the cabins are improved. In this study, the sound absorbtion barrier is experimentally researched by change the volume and the length of the neck for the Helmholtz resonator as the resonator can absorb the noise effectively.

  • PDF

The Design of IoT Device System for Disaster Prevention using Sound Source Detection and Location Estimation Algorithm (음원탐지 및 위치 추정 알고리즘을 이용한 방재용 IoT 디바이스 시스템 설계)

  • Ghil, Min-Sik;Kwak, Dong-Kurl
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.8
    • /
    • pp.53-59
    • /
    • 2020
  • This paper relates to an IoT device system that detects sound source and estimates the sound source location. More specifically, it is a system using a sound source direction detection device that can accurately detect the direction of a sound source by analyzing the difference of arrival time of a sound source signal collected from microphone sensors, and track the generation direction of a sound source using an IoT sensor. As a result of a performance test by generating a sound source, it was confirmed that it operates very accurately within 140dB of the acoustic detection area, within 1 second of response time, and within 1° of directional angle resolution. In the future, based on this design plan, we plan to commercialize it by improving the reliability by reflecting the artificial intelligence algorithm through big data analysis.

Application of the artificial intelligence for automatic detection of shipping noise in shallow-water (천해역 선박 소음 자동 탐지를 위한 인공지능 기법 적용)

  • Kim, Sunhyo;Jung, Seom-Kyu;Kang, Donhyug;Kim, Mira;Cho, Sungho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.4
    • /
    • pp.279-285
    • /
    • 2020
  • The study on the temporal and spatial monitoring of passing vessels is important in terms of protection and management the marine ecosystem in the coastal area. In this paper, we propose the automatic detection technique of passing vessel by utilizing an artificial intelligence technology and broadband striation patterns which are characteristic of broadband noise radiated by passing vessel. Acoustic measurements to collect underwater noise spectrum images and ship navigation information were conducted in the southern region of Jeju Island in South Korea for 12 days (2016.07.15-07.26). And the convolution neural network model is optimized through learning and validation processes based on the collected images. The automatic detection performance of passing vessel is evaluated by precision (0.936), recall (0.830), average precision (0.824), and accuracy (0.949). In conclusion, the possibility of the automatic detection technique of passing vessel is confirmed by using an artificial intelligence technology, and a future study is proposed from the results of this study.

Discrimination of the Heated Coconut Oil using the Electronic Nose (전자코를 사용한 가열처리 야자유의 판별)

  • Han, Kee-Young;Oh, Se-Yeon;Kim, Jung-Hoan;Youn, Aye-Ree;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.16-21
    • /
    • 2006
  • Effect of heat (160, 190, and $220^{\circ}C$ for 24 hr) on coconut oil was examined by principal component analysis using electronic nose consisting of six metal oxide sensors. Increase in heating temperature decreased ratio of resistance and first principal component score (from +0.952 to -0.325), indicating rancidity of coconut oil increased at high heating temperature. Result of electronic nose based on GC with surface acoustic wave sensor showed significant changes in volatile profiles of coconut oil. High resolution olfactory imaging $(VaporPrint^{TM})$ was particularly useful for evaluating oil quality. Peak numbers and areas increased with increasing heating time and temperature (160, $220^{\circ}C$). Electronic nose analysis can provide simple, fast, and straightforward results and is best suited for quality control and process monitoring in flavor field of food industry.

Leakage detection and management in water distribution systems

  • Sangroula, Uchit;Gnawali, Kapil;Koo, KangMin;Han, KukHeon;Yum, KyungTaek
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.160-160
    • /
    • 2019
  • Water is a limited source that needs to be properly managed and distributed to the ever-growing population of the world. Rapid urbanization and development have increased the overall water demand of the world drastically. However, there is loss of billions of liters of water every year due to leakages in water distribution systems. Such water loss means significant financial loss for the utilities as well. World bank estimates a loss of $14 billion annually from wasted water. To address these issues and for the development of efficient and reliable leakage management techniques, high efforts have been made by the researchers and engineers. Over the past decade, various techniques and technologies have been developed for leakage management and leak detection. These include ideas such as pressure management in water distribution networks, use of Advanced Metering Infrastructure, use of machine learning algorithms, etc. For leakage detection, techniques such as acoustic technique, and in recent yeats transient test-based techniques have become popular. Smart Water Grid uses two-way real time network monitoring by utilizing sensors and devices in the water distribution system. Hence, valuable real time data of the water distribution network can be collected. Best results and outcomes may be produced by proper utilization of the collected data in unison with advanced detection and management techniques. Long term reduction in Non Revenue Water can be achieved by detecting, localizing and repairing leakages as quickly and as efficiently as possible. However, there are still numerous challenges to be met and future research works to be conducted in this field.

  • PDF