• Title/Summary/Keyword: Acoustic experiment

Search Result 698, Processing Time 0.031 seconds

Acoustic Field Analysis of Reverberant Water Tank using Acoustic Radiosity Method and Experimental Verification (음향라디오시티법을 이용한 잔향수조 음장 해석과 실험검증)

  • Kim, Kookhyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.5
    • /
    • pp.464-471
    • /
    • 2019
  • The acoustic power is a major acoustical characteristic of an underwater vehicle and could be measured in a reverberant water tank. In order to obtain accurate measurement results, the acoustic field formed by the sound source should be investigated quantitatively in the reverberant water tank. In this research, the acoustic field of a reverberant water tank containing an underwater sound source has been analyzed by using an acoustic radiosity method one of the numerical analysis methods suitable for the acoustic analysis of the highly diffused space. The source level of the underwater sound source and acoustical properties of the water tank input to the numerical analysis have been estimated by applying the reverberant tank plot method through a preliminary experiment result. The comparison of the numerical analysis result with that of the experiment has verified the accuracy of the acoustic radiosity method.

Analysis of Resonance Characteristics of Bulk Acoustic Resonator with Acoustic Bragg Reflector for Biosensor Development (바이오센서 개발을 위한 음향 브래그 반사층을 가지는 체적탄성파 공진기의 공진특성 분석)

  • Kim, Hee-Young;Kim, Ki-Bok;Ha, Tae-Hoon;Kim, Yong-Il;Lee, Jin-Min;Kim, Man-Soo
    • Journal of Biosystems Engineering
    • /
    • v.34 no.4
    • /
    • pp.260-268
    • /
    • 2009
  • As a basic study to develop a high sensitive biosensor using film bulk acoustic resonator, the mathematical model for analyzing the resonance characteristics of bulk acoustic resonator with acoustic Bragg reflectors was investigated. The simulation results due to the number of acoustic Bragg reflectors with low and high acoustic impedance materials were compared with the experimental results for 1, 2.25 and 5 MHz of PZT based bulk acoustic resonators with various acoustic Bragg reflectors. At the fabricated bulk acoustic resonator with an odd number of acoustic Bragg reflectors, low and high acoustic impedance materials in sequence under the bottom electrode showed better resonance characteristics than even number of acoustic Bragg reflectors. The changes of resonance frequencies due to the increase of number of acoustic Bragg reflectors by simulation and experiment, respectively showed approximately similar tendency but some differences in input impedance between the experiment and simulation were found. The derived mathematical model for describing the resonance characteristics of the bulk acoustic resonator with acoustic Bragg reflector will be available for analyzing the design parameters for development of biosensor using bulk acoustic resonator.

Acoustic Cues in Spoken French for the Pronunciation Assessment Multimedia System (발음평가용 멀티미디어 시스템 구현을 위한 구어 프랑스어의 음향학적 단서)

  • Lee, Eun-Yung;Song, Mi-Young
    • Speech Sciences
    • /
    • v.12 no.3
    • /
    • pp.185-200
    • /
    • 2005
  • The objective of this study is to examine acoustic cues in spoken French for the assessment of pronunciation which is necessary to realization of the multimedia system. The corpus is composed of simple expressions which consist of the French phonological system include all phonemes. This experiment was made on 4 male and female French native speakers and on 20 Korean speakers, university students who had learned the French language more than two years. We analyzed the recorded data by using spectrograph and measured comparative features by the numerical values. First of all, we found the mean and the deviation of all phonemes, and then chose features which had high error frequency and great differences between French and Korean pronunciations. The selected data were simplified and compared among them. After we judged whether the problems of pronunciation in each Korean speaker were either the utterance mistake or the interference of mother tongue, in terms of articulatory and auditory aspects, we tried to find acoustic features as simplified as possible. From this experiment, we could extract acoustic cues for the construction of the French pronunciation training system.

  • PDF

Automation of electrical acoustic experimental apparatus for the directivity measurement of sound (소리의 지향성 측정을 위한 전기음향실험기기의 자동화)

  • Jarng, Soon-Suck;Ko, Jae-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.574-576
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a sloping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

Automatic control of experimental apparatus for sound's directivity measurement direction acoustic wave (소리의 방향성 측정을 위한 실험기기의 자동제어)

  • Jarang, Sun-Suck;Ko, Jae-Ha;Lee, Je-Hyeong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.591-594
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a steping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

A Study on the Acoustic Detection of Partial Discharges in Insulation Oil (유중 부분방전의 음향검출에 관한 연구)

  • Kil, Gyung-Suk;Kim, Sung-Wook;Park, Dae-Won;Kim, Sun-Jae;Song, Jae-Man
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • This paper dealt with the acoustic detection of partial discharge (PD) in insulation oil for insulation diagnostics of oil immersed transformers. Electrode systems such as needle to plane, plane to plane, and floating were fabricated to simulate some defects in transformers. A wide band acoustic emission(AE) sensor with the frequency ranges of 100 kHz~1 MHz and a narrow band AE sensor with the resonant frequency of 140 kHz were used in the experiment. Also, a decoupler and an amplifier were designed to detect and amplify the acoustic signal only. The decoupler separates acoustic signal from DC source without any distortion, and the amplifier has the gain of 40 dB in frequency ranges of 11 kHz~4 MHz. In the experiment, frequency components and propagation characteristics of acoustic signal were analyzed, and an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the results, the frequency components of the acoustic signal exist from 50 kHz to 200 kHz and the positioning error of PD calculated by three AE sensors was within 1%.

A perceptual and acoustical study of /ㅅ/ in children's speech (아동이 산출한 치조마찰음 /ㅅ/에 대한 청지각적·음향학적 연구)

  • Kim, Jiyoun;Seong, Cheoljae
    • Phonetics and Speech Sciences
    • /
    • v.10 no.3
    • /
    • pp.41-48
    • /
    • 2018
  • This study examined the acoustic characteristics of Korean alveolar fricatives of normal children. Developing children aged 3 and 7, typically produced 2 types of nonsense syllables containing alveolar fricative /sV/ and /VsV/ sequences where V was any one of three corner vowels (/i, a, and u/). Stimuli containing the speech materials used in a production experiment were presented randomly to 12 speech language pathologists (SLPs) for a perception test. The SLPs responded by selecting one of seven alternative sounds. Acoustic measures such as duration of frication noise, normalized intensity, skewness, and center of gravity were examined. There was significant difference in acoustic measures when comparing vowels. Comparison of syllable structures indicated statistically significant differences in duration of frication noise and normalized intensity. Acoustic parameters could account for the perceptual data. Relating the acoustic and perception data by means of logistic regression suggests that duration of frication noise and normalized intensity are the primary cues to perceiving Korean fricatives.

Performance analysis and verification of underwater acoustic communication simulator in medium long-range multiuser environment (중장거리 다중송신채널 환경에서 수중음향통신 시뮬레이터 성능 분석 및 검증)

  • Park, Heejin;Kim, Donghyeon;Kim, J.S.;Song, Hee-Chun;Hahn, Joo Young
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.6
    • /
    • pp.451-456
    • /
    • 2018
  • UAComm (Underwater Acoustic Communication) is an active research area, and many experiment has been performed to develop UAComm system. In this paper, we investigate the possibility of modifying and applying VirTEX (Virtual Time series EXperiment) to medium long range MIMO (Multiple-Input Multiple-Output) UAComm of about 20 km range for the analysis and performance prediction of UAComm system. Since VirTEX is a time-domain simulator, the generated time series can be used in HILS (Hardware In the Loop Simulation) to develop UAComm system. The developed package is verified through comparing with the sea-going FAF05 (Focused Acoustic Field 2005) experimental data. The developed simulator can be used to predict the performance of UAComm system, and even replace the expensive sea-going experiment.

A Study on Inversion of Seismic Normal Reflection Data (탄성파 수직반사자료의 역산 연구)

  • Yang, Dong Woo;Yang, Seung Jin;Jang, Seong Hyeong
    • Economic and Environmental Geology
    • /
    • v.29 no.5
    • /
    • pp.629-637
    • /
    • 1996
  • In this paper a numerical experiment is conducted to determine the low acoustic impedance of a thin oil or gas reservoir from a seismogram by using the generalized linear inversion method. The seismograms used are normal incident synthetic seismograms containing p-wave primary reflections, multiples, and peg-leg multiples on the layers consisting of oil-, gas-, water-filled sandstone incased in shales. In this experiment the acoustic impedance, the location of reservoir boundary, thickness, and source wavelet are assumed initially and revised iteratively by the least-squares-error technique until the difference between the seismogram and calculated one is very small. This experiment shows that the acoustic impedance and thickness, about 10 m thick, can be determined by the inversion.

  • PDF

The Use of Psycho-Acoustic Method on the Evaluation of the Road Traffic Noise in the Urban Residential Area (도시주거지역 도로교통소음 평가에 있어서 청감실험의 이용에 관한 연구)

  • Kook, Chan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.43-48
    • /
    • 1993
  • This study was carried out to verificate the possibility of using the laboratory setting psycho-acoustic experiment compared with the field and to delineate the appropriate indices in evaluating the Noisiness of road traffic noise by means of psycho-acoustic method. Reviewing the typical patterns of traffic noises depending upon the shapes ad conditions of the road, the road traffic noises in several representative points in the major residential areas in Kwangju city were recorded and reproduced with the noise levels modified in various steps. With these 20 sound sources, psycho-acoustic experiments in the laboratory were performed on 11 volunteer subjects. And then, psycho-acoustic experiments in the real field were performed on 10 volunteer subjects to compare the results of the laboratory experiment, the results are summerized as follows : 1. The psycho-acoustic experiments in the laboratory elicited the data well matching with those obtained in the field, resulting in even higher corelation levels. This indicates that the field assessement of responses to the noise can be replaced by the evaluatioin in the laboratory settings which render many variables easily controlled and that the responses of the residents to the noise can be easily predicted in the laboratory by applying this method. 2. Also among the complex indices, such as Noise Pollution Level or Annoyance Index high correlations were detected. On the other hand, low corelations were noted among Traffic Noise Index. 3. Highly significant correlations were found among the direct indices such as Leq, L\sub 10\, On the other hand, low correlations were detected among L\sub 50\.

  • PDF