• 제목/요약/키워드: Acoustic calibration

검색결과 48건 처리시간 0.026초

Audiometric Calibration of Aural Acoustic Immittance Instrument: A Review of Acoustic Immittance Instrument's Calibration

  • Kim, Jin-Dong
    • 대한의생명과학회지
    • /
    • 제22권4호
    • /
    • pp.115-126
    • /
    • 2016
  • Audiometric calibration is a prerequisite for securing the reliability of audiometric test results by checking the internal consistency of the relevant instrument. The purpose of this review is to help instrument operators understand the calibration procedure of aural acoustic immittance instrument which is frequently used for objective assessment. By referring to the latest international standards and the national standards relevant to the aural acoustic immittance instrument, the following parameters will be reviewed: 1) introduction of performance characteristics, 2) detailed procedure of the calibration method. According to the newest international and national standards [IEC 60645-5 (2004), ANSI S3.39-1987 (R2012)], the aural acoustic immittance instrument basically includes six components: 1) calibration cavity, 2) acoustic immittance analysis system, 3) probe assembly/unit and signal, 4) pneumatic air-pressure pump system, 5) acoustic reflex activator system and 6) tympanogram and acoustic reflex plotting system, each of these components should meet set standards. The result of behavioral hearing tests is influenced by various complex factors including the examinee's cooperation, background noise of the examination room, measurement method, skill level of the audiologist and calibration status, but the objective hearing tests is more influenced by the calibration status of the instrument than any other factors. The audiologist should take full responsibility for the reliability of the hearing test result, so he/she should carry out the calibration check and adjustments of aural acoustic immittance instrument periodically and maintain the instrument continuously by referring to the newest standards and the manufacturer's instruction manual.

KRISS에서 수행된 음향관련 교정 및 시험 동향 (Tendency of Calibration and Test for Acoustic Field in KRISS)

  • 서재갑;권휴상;정성수;조문재;서상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

초음파 도플러 유속계 교정 시설 현황 (Analysis of Calibration Facilities for Acoustic Doppler Current Profilers (ADCPs))

  • 이정한;황근춘;김은수
    • Ocean and Polar Research
    • /
    • 제33권2호
    • /
    • pp.171-183
    • /
    • 2011
  • Despite technological developments and application advances of Acoustic Doppler Current Profilers (ADCPs), no standard procedure has been adopted or accepted for calibration of ADCPs. Limitations of existing facilities for calibrating ADCPs, the complexity of ADCP instruments, and rapid changes in ADCP technology are some of the reasons why a standard procedure has not been adopted. However, there is increasing realization of the need for effective Quality Assurance (QA) and as part of that the importance of standardized calibration. In this study, the significance of calibration and QA plans for ADCPs is discussed and the calibration facilities for ADCPs at home and abroad are reported. Furthermore, the method for calibrating ADCPs using a towed car and its limitations are discussed. This study contributes to discussions surrounding the establishment of standard procedures for calibrating ADCPs and QA plans, and the construction of calibration facilities in the future.

음향 챔버형 마이크로폰 검교정기의 검교정 주파수 한계와 모드 특성을 이용한 개선 방법에 관한 연구 (A study on calibration frequency limit of acoustic chamber type microphone calibrator and improvement method using mode shape)

  • 김차영;신금재;문원규
    • 한국음향학회지
    • /
    • 제41권1호
    • /
    • pp.1-8
    • /
    • 2022
  • 본 논문은 마이크로폰 검교정을 위한 음향 챔버형 검교정기의 고주파 검교정 한계가 나타나는 원인을 밝히고 이를 향상시키는 방법을 제시한다. 상용 유한요소 해석 프로그램을 활용하여 고유 주파수 해석과 주파수 영역 해석을 통해 음향 챔버형 검교정기의 검교정 주파수 한계를 분석하였고, 이를 바탕으로 약 2 Hz 부터 6.4 kHz 까지 1 dB 수준 이내로 정교하게 검교정할 수 있는 음향 챔버형 검교정기를 설계 및 제작하고 실험을 통해 그 성능을 검증하였다. 본 연구를 통해 제안된 음향 챔버형 검교정기는 넓은 주파수 범위에서 다수의 마이크로폰을 동시에 검교정 할 수 있는 이점을 가지고 있어 다수의 마이크로폰을 위한 간편한 검교정에 유용하게 사용될 수 있다.

가속도계 정밀 위상 교정 시스템 (Precision Phase Calibration System of Accelerometers)

  • 이용봉;정성수;진종한
    • 한국정밀공학회지
    • /
    • 제28권5호
    • /
    • pp.585-590
    • /
    • 2011
  • Accelerometers have been exploited widely in various fields from monitoring vibration of precision machines to detecting an earthquake wave. The precision calibration of the accelerometers is required to maintain the measurement reliability when measuring the vibration of objects with accelerometers for modal analysis. Among evaluation factors for determining sensitivity of accelerometers, phase delay term should be also considered for accurate calibration. In this paper, a new calibration system of accelerometers capable of measuring phase delay as well as magnitude of its sensitivity was proposed and realized in the frequency range of 20 Hz to 5 kHz.

KRISS 에서 수행된 음향관련 교정 및 시험 검사 동향 (Tendency of Calibration and Test for Acoustic Field in KRISS)

  • 서재갑;정성수;조문재;서상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1767-1771
    • /
    • 2000
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 1999. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

선 집속 초음파 현미경을 이용한 음탄성효과 측정에 의한 응력 평가 (Stress Evaluation by the Measurement of Acoustoelastic Effect Using a Line-Foucus Acoustic Microscope)

  • Kim, J.O.;Lee, Y.C.
    • 한국정밀공학회지
    • /
    • 제14권10호
    • /
    • pp.119-126
    • /
    • 1997
  • The relationship between the applied stresses and the change of elastic wave velocity has been established based on the acoustoelasticity theory. The non-uniform stress field in a loaded specimen has been evaluated from the surface acoustic wave velocity measured by the line-focus acoustic microscopy with the acoustoelastic constants obtained form a calibration test. The evaluated stresses are in good agreement with the results calculated by finite element method.

  • PDF

기준음원의 교정 절차 개발 및 불확도 평가 사례 (Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation)

  • 서재갑;조완호
    • 한국음향학회지
    • /
    • 제43권3호
    • /
    • pp.344-350
    • /
    • 2024
  • 기준음원은 음향파워 측정에 활용되는 중요한 기준기로, 국제 표준으로 그 사양이 규정되어 있으며, 측정 표준 분야에서 주요 교정 품목으로 분류되고 있다. 이러한 기준음원은 공급 전압에 의하여 그 출력이 영향을 받기 때문에 각국에서 자체적으로 교정 서비스 체계를 확보할 필요가 있다. 본 연구에서는 잔향실 조건에서 기준음원을 교정하는 절차를 수립하고 불확도를 평가하였다. 교정 절차는 기본적으로 음향 파워의 정밀급 측정과정을 적용할 수 있으며, 여기서는 ISO 3741의 잔향실을 활용한 측정 방법을 검토하였다. 이를 위한 측정 시스템을 구성하고 실제 2종의 기준 음원에 대하여 측정을 수행하고 측정 불확도를 산출하였다. 측정 예를 통하여 잔향실 내 음압 분포의 불균일성과 체적 측정 불확도가 전체 불확도에 기여가 큰 것을 확인하였다. 추가적으로 입력 전압에 대한 영향을 실험적으로 검토하여 음향 파워 측정에서 반영할 수 있는 불확도 기여량을 검토하였다.

주파수특성이 다른 2개의 초음파 친서에 의한 GIS 이물진단 기술 연구 (A Study on the Technology Diagnosing Particles with Two Acoustic Emission Sensors Which have the Different Characteristics of Frequency in GIS)

  • 김광화;최재구;선종호;김익수;윤진열
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권5호
    • /
    • pp.219-225
    • /
    • 2003
  • This paper described about the acoustic wave measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves with two type acoustic sensors having 125kHz and 50kHz resonant frequency respectively when the particles were bounced on the inside surfaces of GIS tanks by the electrostatic force. To use two sensors for the diagnosis of GIS, we set up the calibration method for this measurement method. We showed the output characteristics of two sensors according to the sizes and materials of particles in the experiment. As the results, the inception voltages bouncing particles depended on the materials and the extinction voltages bouncing them depended on the sizes and materials. We found out that the relationship between sizes of particles and output voltages of sensors didn't have linearity but the ratios of between peak values of two sensors depended on the materials of GIS enclosures and the sizes of particles.

주파수특성이 다른 2개의 초음파 친서에 의한 GIS 이물진단 기술 연구 (A Study on the Technology Diagnosing Particles with Two Acoustic Emission Sensors Which have the Different Characteristics of Frequency in GIS)

  • 김광화;최재구;선종호;김익수;윤진열
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권5호
    • /
    • pp.219-219
    • /
    • 2003
  • This paper described about the acoustic wave measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves with two type acoustic sensors having 125kHz and 50kHz resonant frequency respectively when the particles were bounced on the inside surfaces of GIS tanks by the electrostatic force. To use two sensors for the diagnosis of GIS, we set up the calibration method for this measurement method. We showed the output characteristics of two sensors according to the sizes and materials of particles in the experiment. As the results, the inception voltages bouncing particles depended on the materials and the extinction voltages bouncing them depended on the sizes and materials. We found out that the relationship between sizes of particles and output voltages of sensors didn′t have linearity but the ratios of between peak values of two sensors depended on the materials of GIS enclosures and the sizes of particles.