Audiometric Calibration of Aural Acoustic Immittance Instrument: A Review of Acoustic Immittance Instrument's Calibration

  • Kim, Jin-Dong
    • Biomedical Science Letters
    • /
    • v.22 no.4
    • /
    • pp.115-126
    • /
    • 2016
  • Audiometric calibration is a prerequisite for securing the reliability of audiometric test results by checking the internal consistency of the relevant instrument. The purpose of this review is to help instrument operators understand the calibration procedure of aural acoustic immittance instrument which is frequently used for objective assessment. By referring to the latest international standards and the national standards relevant to the aural acoustic immittance instrument, the following parameters will be reviewed: 1) introduction of performance characteristics, 2) detailed procedure of the calibration method. According to the newest international and national standards [IEC 60645-5 (2004), ANSI S3.39-1987 (R2012)], the aural acoustic immittance instrument basically includes six components: 1) calibration cavity, 2) acoustic immittance analysis system, 3) probe assembly/unit and signal, 4) pneumatic air-pressure pump system, 5) acoustic reflex activator system and 6) tympanogram and acoustic reflex plotting system, each of these components should meet set standards. The result of behavioral hearing tests is influenced by various complex factors including the examinee's cooperation, background noise of the examination room, measurement method, skill level of the audiologist and calibration status, but the objective hearing tests is more influenced by the calibration status of the instrument than any other factors. The audiologist should take full responsibility for the reliability of the hearing test result, so he/she should carry out the calibration check and adjustments of aural acoustic immittance instrument periodically and maintain the instrument continuously by referring to the newest standards and the manufacturer's instruction manual.

Tendency of Calibration and Test for Acoustic Field in KRISS (KRISS에서 수행된 음향관련 교정 및 시험 동향)

  • 서재갑;권휴상;정성수;조문재;서상준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

Analysis of Calibration Facilities for Acoustic Doppler Current Profilers (ADCPs) (초음파 도플러 유속계 교정 시설 현황)

  • Lee, Jung-Han;Hwang, Keun-Choon;Kim, Eun-Soo
    • Ocean and Polar Research
    • /
    • v.33 no.2
    • /
    • pp.171-183
    • /
    • 2011
  • Despite technological developments and application advances of Acoustic Doppler Current Profilers (ADCPs), no standard procedure has been adopted or accepted for calibration of ADCPs. Limitations of existing facilities for calibrating ADCPs, the complexity of ADCP instruments, and rapid changes in ADCP technology are some of the reasons why a standard procedure has not been adopted. However, there is increasing realization of the need for effective Quality Assurance (QA) and as part of that the importance of standardized calibration. In this study, the significance of calibration and QA plans for ADCPs is discussed and the calibration facilities for ADCPs at home and abroad are reported. Furthermore, the method for calibrating ADCPs using a towed car and its limitations are discussed. This study contributes to discussions surrounding the establishment of standard procedures for calibrating ADCPs and QA plans, and the construction of calibration facilities in the future.

A study on calibration frequency limit of acoustic chamber type microphone calibrator and improvement method using mode shape (음향 챔버형 마이크로폰 검교정기의 검교정 주파수 한계와 모드 특성을 이용한 개선 방법에 관한 연구)

  • Kim, Chayeong;Shin, Kumjae;Moon, Wonkyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • This paper identifies the cause of the high frequency calibration limit of the acoustic chamber type calibrator for microphone calibration and presents a method to improve it. By using a commercial finite element analysis software, we analyzed the calibration frequency limit of the acoustic chamber type calibrator through eigen-frequency and frequency domain analysis. Based on this, we designed and fabricated an acoustic chamber type calibrator that can precisely calibrate within 1 dB from about 2 Hz to 6.4 kHz and verified its performance through experiments. The acoustic chamber type calibrator fabricated through this study has the advantage of being able to calibrate multiple microphones simultaneously in a wide frequency range, so it can be usefully used for simple calibration for multiple microphones.

Precision Phase Calibration System of Accelerometers (가속도계 정밀 위상 교정 시스템)

  • Lee, Yang-Bong;Jung, Sung-Soo;Jin, Jong-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.5
    • /
    • pp.585-590
    • /
    • 2011
  • Accelerometers have been exploited widely in various fields from monitoring vibration of precision machines to detecting an earthquake wave. The precision calibration of the accelerometers is required to maintain the measurement reliability when measuring the vibration of objects with accelerometers for modal analysis. Among evaluation factors for determining sensitivity of accelerometers, phase delay term should be also considered for accurate calibration. In this paper, a new calibration system of accelerometers capable of measuring phase delay as well as magnitude of its sensitivity was proposed and realized in the frequency range of 20 Hz to 5 kHz.

Tendency of Calibration and Test for Acoustic Field in KRISS (KRISS 에서 수행된 음향관련 교정 및 시험 검사 동향)

  • Suh, Jae-Gap;Jung, Sung-Soo;Jho, Moon-Jae;Suh, Sang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1767-1771
    • /
    • 2000
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 1999. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

Stress Evaluation by the Measurement of Acoustoelastic Effect Using a Line-Foucus Acoustic Microscope (선 집속 초음파 현미경을 이용한 음탄성효과 측정에 의한 응력 평가)

  • Kim, J.O.;Lee, Y.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.119-126
    • /
    • 1997
  • The relationship between the applied stresses and the change of elastic wave velocity has been established based on the acoustoelasticity theory. The non-uniform stress field in a loaded specimen has been evaluated from the surface acoustic wave velocity measured by the line-focus acoustic microscopy with the acoustoelastic constants obtained form a calibration test. The evaluated stresses are in good agreement with the results calculated by finite element method.

  • PDF

Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation (기준음원의 교정 절차 개발 및 불확도 평가 사례)

  • Jae-Gap Suh;Wan-Ho Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.344-350
    • /
    • 2024
  • A Reference Sound Source (RSS) is an important standard device employed in measuring sound power. The specifications of RSS is specified in international standards, and it is classified as a major calibration item in the field of acoustic metrology. Since the output power of RSS is affected by the supply voltage, each country needs to secure its own calibration service system. In this study, a procedure for calibrating a RSS is established based on the reverberant room conditions and uncertainty evaluation is conducted. Basically, the calibration procedure can apply a precision measurement process of acoustic power, and here, the measurement method using the reverberation chamber of ISO 3741 is applied. For this purpose, a measurement system is constructed, measurements are conducted with two types of RSS, and measurement uncertainty is evaluated. Through measurement examples, it is confirmed that the non-uniformity of the sound pressure distribution in the reverberation room and the volume measurement uncertainty contributed significantly to the overall uncertainty. Additionally, the influence of input voltage is experimentally examined to examine the uncertainty contribution that can be reflected in acoustic power measurements.

A Study on the Technology Diagnosing Particles with Two Acoustic Emission Sensors Which have the Different Characteristics of Frequency in GIS (주파수특성이 다른 2개의 초음파 친서에 의한 GIS 이물진단 기술 연구)

  • 김광화;최재구;선종호;김익수;윤진열
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.5
    • /
    • pp.219-225
    • /
    • 2003
  • This paper described about the acoustic wave measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves with two type acoustic sensors having 125kHz and 50kHz resonant frequency respectively when the particles were bounced on the inside surfaces of GIS tanks by the electrostatic force. To use two sensors for the diagnosis of GIS, we set up the calibration method for this measurement method. We showed the output characteristics of two sensors according to the sizes and materials of particles in the experiment. As the results, the inception voltages bouncing particles depended on the materials and the extinction voltages bouncing them depended on the sizes and materials. We found out that the relationship between sizes of particles and output voltages of sensors didn't have linearity but the ratios of between peak values of two sensors depended on the materials of GIS enclosures and the sizes of particles.

A Study on the Technology Diagnosing Particles with Two Acoustic Emission Sensors Which have the Different Characteristics of Frequency in GIS (주파수특성이 다른 2개의 초음파 친서에 의한 GIS 이물진단 기술 연구)

  • 김광화;최재구;선종호;김익수;윤진열
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.5
    • /
    • pp.219-219
    • /
    • 2003
  • This paper described about the acoustic wave measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves with two type acoustic sensors having 125kHz and 50kHz resonant frequency respectively when the particles were bounced on the inside surfaces of GIS tanks by the electrostatic force. To use two sensors for the diagnosis of GIS, we set up the calibration method for this measurement method. We showed the output characteristics of two sensors according to the sizes and materials of particles in the experiment. As the results, the inception voltages bouncing particles depended on the materials and the extinction voltages bouncing them depended on the sizes and materials. We found out that the relationship between sizes of particles and output voltages of sensors didn′t have linearity but the ratios of between peak values of two sensors depended on the materials of GIS enclosures and the sizes of particles.