• Title/Summary/Keyword: Acoustic Sensor

Search Result 725, Processing Time 0.033 seconds

Surface acoustic wave gas sensors by assembling gas chromatography column (가스 크로마토그래피를 부착한 표면탄성파 가스 센서)

  • Yoo, Beom-Keun;Park, Yong-Wook;Kang, Chong-Yun;Yoon, Seok-Jin;Choi, Doo-Jin;Kim, Jin-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.39-43
    • /
    • 2007
  • This paper presents characteristics of surface acoustic wave (SAW) gas sensor for detecting volatile gases such as acetone, methanol, and ethanol by measuring phase shift of output signal. A delay-line by combining with a center frequency of 200 MHz was fabricated on S-T Quartz substrates. Using gas chromatography column, the selectivity of the SAW gas sensor were introduced. Experimental results, which show the phase change of output signal under the absorption of volatile gas on sensor surface, were presented. This SAW gas sensor system may be well suited for a high performance electronic nose system.

Development of novel strain sensor using surface acoustic wave (새로운 표면탄성파를 이용한 변형률 센서 개발)

  • Oh, Hae-Kwan;Hwang, U-Jin;Eun, Kyung-Tae;Choa, Sung-Hun;Lee, Kee-Keun;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.594-599
    • /
    • 2011
  • A SAW strain sensor based on Shear Horizontal wave with an 92 MHz central frequency was developed. It consists of SAW sensor, PCB substrate and bonding material (Loctite 401). External force applied to PCB substrate bonded to a piezoelectric substrate induces strain at the substrate surface, which causes changes in the elastic constant and density of the substrate and hence the propagation velocity of the SAW. The change in the velocity of the SAW result in a frequency shift of the sensor and by measuring a frequency shift, we can extract the strain induced by the external force. The $41^{\circ}$ YX $LiNbO_3$ was used because it has a Leaky shear horizontal(SH) wave propagation mode and a high electromechanical coupling coefficient ($K^2$=17.2%). And to compare with Rayleigh wave mode, $128^{\circ}$ YX $LiNbO_3$ was used. And to make a stable and low insert loss, Split IDT structure was used. The obtained sensitivity and linearity of the SAW strain sensor in the case of Split IDT were measured to be 17.2 kHz / % and 0.99, respectively.

Nondestructive Evaluation and Interfacial Damage Sensing of PVDF embedded Polymer Composites using Micromechanical Techniques and Acoustic Emission (Micromechanical 시험법과 AE를 이용한 PVDF 함침 고분자 복합재료의 계면손상감지능 및 비파괴적 평가 연구)

  • Kong, Jin-Woo;Park, Joung-Man;Kim, Ki-Bok;Yoon, Dong-Jin
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.216-219
    • /
    • 2002
  • Conventional piezoelectric lead-zirconate-titanate (PZT) senor has high sensitivity, but it is very brittle. Recently polymer films such as polyvinylidene fluoride (PVDF) have been used use as a sensor. The advantages of PVDF are the flexibility and mechanical toughness. Simple process and possible several shapes are also additional advantages. PVDF sensor can be directly embedded and attached to a structure. In this study, PVDF sensor was embedded in single glass fiber/epoxy composites whereas PZT sensor with AE was attached to single fiber composites (SFC). Piezoelectric sensor responds to interfacial damage of SFC. The signals measured by PVDF sensor were compared to PZT sensor. PZT sensor detected the signals of fiber fracture, matrix crack, interfacial debonding and even sensor delamination, whereas PVDF sensor only detected fiber fracture signals so far, because PZT sensor is much more sensitive than current PVDF sensor. Wave voltage of fiber fracture measured by PVDF sensor was lower than that of PZT sensor, but the results of fast Fourier transform (FFT) analysis were same. Wave velocity using two PZT sensors was also studied to know the internal and surface damage effect of epoxy specimens.

  • PDF

A Network Coding Scheme with Code Division Multiple Access in Underwater Acoustic Sensor Networks (수중 센서 네트워크에서 코드 분할 다중 접속 방식을 사용하는 네트워크 코딩 기법)

  • Seo, Bo-Min;Cho, Ho-Shin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.86-94
    • /
    • 2013
  • In this paper, we propose a network coding scheme that is one of the most promising techniques for overcoming transmission errors in underwater acoustic communications. It is assumed that the proposed scheme operates in a Code Division Multiple Access (CDMA) network where multiple sensor nodes share the underwater acoustic channel in both the frequency and the time domains by means of orthogonal codes. The network topology deploys multi-hop transmission with relaying between multiple source nodes and one destination node via multiple relay nodes. The proposed scheme is evaluated in terms of the successful packet delivery ratio of end-to-end transactions under varying packet loss rates. A computer simulation shows that the successful delivery ratio is maintained at over 95% even when the packet loss rate reaches 50%.

Fabrication and Characterization of an Underwater Acoustic Tonpilz Vector Sensor for the Estimation of Sound Source Direction (음원의 방향 추정을 위한 수중 음향 Tonpilz 벡터 센서의 제작 및 특성 평가)

  • Lim, Youngsub;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.351-359
    • /
    • 2015
  • Typical underwater acoustic transducers detect only the magnitude of an acoustic pressure and they have the limitation of not being able to recognize the direction of the sound signal. Hence, the authors of this paper proposed a new vector sensor structure based on Tonpilz transducers that could detect both the magnitude and the direction of a sound pressure. In the proposed structure, the piezoceramic ring was divided into four segments, and proper combination of the output voltages of the segments in response to the external sound pressure could provide the information on the orientation of the sound source. In this paper, a Tonpilz transducer has been fabricated to have the proposed structure and its characteristics has been measured to confirm the validity of the proposed structure.

Development of Acoustic Resonance Evaluation System to Detect the Welding Defects (용접 불량 검사를 위한 음향공진 검사 장치 개발)

  • Yeom, Woo Jung;Kim, Jin Young;Hong, Yeon Chan;Kang, Joonhee
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.371-376
    • /
    • 2019
  • We have developed an acoustic resonance inspection system to inspect the welding defects in the mechanical parts fabricated using friction stir welding method. The inspection system was consisted of a DAQ board, a microphone sensor, an impact hammer, and controlled by a PC software. The system was developed to collect and analyze the sound signal generated by hitting the sample with an impact hammer to determine whether it is defective. In this study, 100% welded good samples were compared with 95%, 90%, and 85% welded samples, respectively. The variation of the completeness in welding did not affect the visual appearance in the samples. As a result of analyzing the natural frequencies of the good samples, the five natural frequency peaks were identified. In the case of the defective samples, the frequency change was observed. The welding failure detection time was fast enough to be only 0.7 seconds. Employing our welding defect inspection system to the actual industrial field will maximize the efficiency of quality inspection and thus improve the productivity.

Study on Improvement of the Piezoelectric Properties of Acoustic Emission Sensor to be Used for Superconducting Application Systems (초전도 응용기기 안정성 진단을 위한 AE센서용 압전소자의 성능개선 연구)

  • Kim, K.J.;Kim, J.H.;Song, J.B.;Paik, J.H.;Jang, J.Y.;Ko, T.K.;Lee, H.G.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.44-48
    • /
    • 2010
  • Acoustic emission (AE) signal from an HTS tape has a low signal to noise ratio, due to the large amount of noise caused by the boiling of the liquid cryogen or mechanical vibration from the cryo-cooler. In an attempt to improve the sensitivity of the AE sensor, $Pb(Zr_{0.54}Ti_{0.46})O_3$ + 0.2 wt% $Cr_2O_3$ + 1.0 wt.% $Nb_2O_5$ ceramics sintered at $1200^{\circ}C$ was synthesized. In addition, the resonance ($f_r$) and anti-resonance frequencies ($f_a$) were measured using the specimens with various thicknesses (1.0, 1.5, 2.0, 2.5 and 3.0 mm). According to the test results, large AE signals with high frequencies were obtained from the AE sensor fabricated using a piezoelectric disc with a thinner thickness.

Crack Propagation and Acoustic Emission Evaluation of Plain Woven CFRP Laminate Composites for Fiber Orientation (섬유방향 변화에 따른 직물구조 CFRP 적층판의 균열진전 및 AE평가)

  • Yun, Yu-Seong;Kwon, Oh-Heon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.364-369
    • /
    • 2003
  • Crack propagation and AE characteristics of CFRP plain woven laminate composites are examined with acoustic sensor by AEDSP 32/16 board in PC system. AE signals are measured during the fracture behavior tests. The purpose of study is the estimation of the crack extension behavior effected between three kinds of fiber orientation for plain woven CFRP laminate composite and the relationship between AE characteristics and load-displacement curves and crack extension length.

  • PDF

Wear Detection of Coated Tool Using Acoustic Emission (음향방출을 이용한 코팅공구의 마멸검출)

  • 맹민재;정준기
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.5
    • /
    • pp.9-16
    • /
    • 2001
  • Turning experiments are conducted to investigate characteristics of acoustic emission due to wear of the coated tool. The AE signals are obtained with a sensor attached to tool holder side. Tool states are identified with scanning electron microscopy and optical microscopy. It is demonstrated that the AE signals provide reliable informations about the cutting processes and tool states. Moreover, tool wear can be detected successfully using the AE-RMS.

  • PDF

surface acoustic wave oscillator hymidity sensor using hexafluoropropene plasma thin film (헥사플루오르프로펜 플라즈마박막을 이용한 표면탄성파발진기 습도센서)

  • 박남천;서은덕
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.05a
    • /
    • pp.144-146
    • /
    • 1992
  • Surface acoustic wave(SAW) oscillator offers many attractive features for application to vapor sensors. The perturbation of SAW velocity by the hexafluoropropence plasma polymer thin film has been studied for relative humidity sensing. adsorption of moisture produces rapid aid changes in the properties of the film, resulting in a change in the velocity of surface acoustic waves and, hence, in the frequency of one SAW oscillator. The device used in our experiments have 55 MHZ SAW oscillator fabricated on a LiNbO substrate.

  • PDF