• 제목/요약/키워드: Acoustic Performance

검색결과 1,482건 처리시간 0.03초

Extraction of empirical formulas for electron and hole mobility in $In_{0.53}(Al_xGa_{1-x})_{0.47}As$ ($In_{0.53}(Al_xGa_{1-x})_{0.47}As$의 전자와 정공 이동도의 실험식 추출)

  • 이경락;황성범;송정근
    • Electrical & Electronic Materials
    • /
    • 제9권6호
    • /
    • pp.564-571
    • /
    • 1996
  • We calculated the drift-velocities of electrons and holes of I $n_{0.53}$(A $l_{x}$G $a_{1-x}$ )$_{0.47}$As, which is used for semiconductor materials of high performance HBTs, along with the various doping concentrations and Al mole fractions as well as the electric fields by Monte Carlo experiment. Especially, for the valence bands the accuracy of hole-drift-velocity was improved in the consideration of intervalley scattering due to the inelastic scattering of acoustic phonon. From the results the empirical formulas of the low- and high field mobility of electrons and holes were extracted by using nonlinear least square fitting method. The accuracy of the formulas was proved by comparing the formula of low-field electron mobility as well as drift-velocity of I $n_{0.53}$ G $a_{0.47}$As and of low-field hole mobility of GaAs with the measured values, where the error was below 10%. For the high-field mobilities of electron and hole the results calculated by the formulas were very well matched with the MC experimental results except at the narrow field range where the electrons produced the velocity overshoot and the corresponding error was about 30%.0%. 30%.0%.

  • PDF

Turbine discharge measurement case study using ASFM system (ASFM을 이용한 수차유량의 측정)

  • Kim, Eung-Tae;Jeong, Yong-Chea;Park, Jang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.49-52
    • /
    • 2006
  • should be in English, A make out an economical, reliable and easy to adoptable instrument in turbine discharge measurement was restricted from lots of it's foundational condition. Not with standing the brilliant progress in new technology of these day, useful instrument for flow measurement in turbine is still ongoing. Nowaday, the increasing importance of renewable energy makes it more important that the measuring turbine efficiency as a decision making index of old turbines' replacement. In Turbine performance diagnosis, Kwater(Korea Water Corporation) got an enough ability and decent reputation for who has invested lots of time and effort for buildup and development. In Korea as a public corporation who should take a crucial roll in Turbine business, Kwater has introduced some developed new technology for other domestic concerned one. With this writing, I'd like to introduce ASFM system as a newly developed instrument that can cope with lots restriction in discharge measurement in turbine. Kwater adopted the system in 2005, and performed 2 times of trial test. The test result was good enough to use the system as a reference test method.

  • PDF

Computation of Turbulent Flows and Radiated Sound From Axial Compressor Cascade

  • Lee, Seungbae;Kim, Hooi-Joong;Kim, Jin-Hwa;Song, Seung-Jin
    • Journal of Mechanical Science and Technology
    • /
    • 제18권2호
    • /
    • pp.272-285
    • /
    • 2004
  • The losses at off-design points from a compressor cascade occur due to the deviation from a design incidence angle at the inlet of the cascade. The self-noise from the blade cascade at off-design points comes from a separated boundary layer and vortex sheddings. If the incidence angle to the cascade increases, stalling in blades may occur and the noise level increases significantly. This study applied Large-Eddy Simulations (LES) using deductive and deductive dynamic SGS models to low Mach-number, turbulent flow with each incidence angle to the cascade ranging from -40$^{\circ}$ to +20$^{\circ}$ and compared numerical predictions with measured data. It was observed that the oscillating separation bubbles attached to the suction surface do not modify wake flows dynamically for cases of negative incidence angles. However, an incidence angle greater than 8$^{\circ}$ caused a separated vortex near the leading edge to be shed downstream and created stalling. The computed performance parameters such as drag coefficient and total pressure loss coefficient showed good agreement with experimental results. Noise from the cascade of the compressor is summarized as sound generated by a structure interacting with unsteady, turbulent flows. The hybrid method using acoustic analogy was observed to closely predict the measured overall sound powers and directivity patterns at design and off-design points of blade cascade.

Acoustic Field Analysis of Ultrasonic Focusing Transducer by Using Finite Element. Method and Hybrid Type Infinite Element Method (유한요소법과 하이브리드형 무한요소법을 이용한 초음파 집속변환자의 음장 해석)

  • Park, Soon-Jong;Yoon, Jong-Rak;Ha, Kang-Lyeol;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • 제14권5호
    • /
    • pp.36-43
    • /
    • 1995
  • This paper presents the lousing characteristics and the time. response of ultrasonic focusing transducer which is a coupled system with an electromechanical and an acoustical component. The Finite Element Method and the Hybrid Type Infinite Element Method are applied for the analysis. The position of the focal points and the resolutions is obtained from the loosing characteristics and the time response. It is found that the transducer with the damper, which stabilizes the displacement of the radiation surface, gives a better resolution. In conclusion, the results could be applied to the design and the performance analysis of the ultrasonic focusing transducer.

  • PDF

Optimal Design of a One-chip-type SAW Duplexer Filter Using Micro-strip Line Lumped Elements (마이크로 스트립라인 집중소자를 이용한 일체형 탄성표면파 듀플렉서 필터의 최적설계)

  • 이승희;이영진;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • 제20권3호
    • /
    • pp.83-90
    • /
    • 2001
  • Conventional SAW duplexer filters employ a 1/4 wavelength transmission line, which causes difficulty in fabrication of the strip line on the package. Its manufacturing process is also complicated, because it needs integrating process of the separate transmitting filter, receiving filter and isolation circuits. This paper concerns development of a new structure of the duplexer filter that has all the transmitting filter, the receiving filter and the isolation circuit as a one chip device. For composition of the duplexer, we design the component SAW ladder filters and the isolation network consisting of lumped inductor and capacitor elements. Performance of the whole duplexer is optimized by the nonlinear multivariable minimization of a proper target function, and the result is compared with that of commercial filters.

  • PDF

Underwater Moving Source Tracking Using a Coherent Broad-band Matched Field Processing Technology (일관성 광대역 정합장처리에 의한 수중 이동음원의 위치추적)

  • 신기철;박재은;김재수
    • The Journal of the Acoustical Society of Korea
    • /
    • 제20권8호
    • /
    • pp.67-73
    • /
    • 2001
  • The shallow-water environment presents additional challenges arising from the complex interaction patterns of the sound with the sea bed. In order to overcome the difficulties generated by shallow-water propagation, broad-band matched field processing has been employed in an effort to increase robustness by utilizing multiple frequency information. In this paper, a coherent broad-band matched field processor is introduced that incorporates the spatial coherence of the acoustic field not only over one frequency but across frequencies. The incoherent and coherent processors are applied to the experimental data where it is shown that both processors give a high probability of correct localization. Also it is found that a coherent processor has better performance in the sidelobe pattern of ambiguity surfaces.

  • PDF

A Study on an Ultrasonic Circular Array Transducer for Intra-vascular Ultra-sound Diagnosis (혈관 내부 진단용 원형 배열 초음파 트랜스듀서에 대한 연구)

  • 김희원;이수성;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • 제22권4호
    • /
    • pp.329-336
    • /
    • 2003
  • Intra-Vascular Ultra-Sound (IVUS) transducers were developed for the application to diagnose coronary diseases. The transducer consists of 32 piezoelectric elements with a front insulation layer and a polymeric acoustic backing layer on a hollow alumina tube. The optimal geometrical structure of the transducer was designed through theoretical analysis of radiation patterns of the transducer. Samples of the IVUS transducers of the diameter of 3㎜ were fabricated to illustrate the design scheme. For the piezoelectric elements, 2-2 mode piezocomposite materials were employed. Experimental performance of the transducers showed good agreement with the design results, which verified feasibility of the transducer for IVUS applications.

Experimental Studies on Aerodynamic Characteristics of Pantograph system for HEMU-400X (차세대 고속열차(HEMU-400X)의 팬터그래프 시스템에 대한 공력특성 연구)

  • Lee, Yeong-Bin;Rho, Joo-Hyun;Kwak, Min-Ho;Lee, Jae-Ho;Kim, Kyu-Hong;Lee, Dong-Ho
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.133-138
    • /
    • 2010
  • This paper describes on aerodynamic characteristics of pantograph system for Next generation high speed train(HEMU-400). The pantograph which supports electric power is located on the roof. Because of this, it generate high drag, severe acoustic noise and vibration which induced unstable flow due to complex configuration. Therefore, the design of high efficient pantograph needs to increase operational speed. In this research, wind tunnel tests were performed to design a high efficient pantograph system using 1/4 scaled model which were KTX-II pantograph, single arm pantograph and periscope type pantograph with square cylinder shape panhead and optimized shape panhead. For real operational condition, flow directions were adapted by rotation of pantograph. From this results of wind tunnel, it is checked that the pantograph with optimized panhead and single arm type or periscope type has better aerodynamic performance. In addition, lift control device and spoiler in pantograph were tested to investigate the validity of application.

  • PDF

Turbulent-induced Noise of 2-dimensional Sonar Dome Shaped Structure (2차원 소나돔 형상 구조물의 난류유동소음 해석)

  • Choi, Yo-Seb;Hong, Suk-Yoon;Song, Jee-Hun;Kwon, Hyun-Wung;Choi, Woen-Sug;Jung, Chul-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제26권1호
    • /
    • pp.39-48
    • /
    • 2016
  • The latest research has shown that the turbulence-induced noise is important in total characteristics of flow noise. Also, turbulence-induced noise have a significant influence for performance of sonar dome. In this paper, Flow analysis is performed on vicinity of the sonar dome model using Large Eddy Simulation method. Also, direct method that extracts perturbational sound pressure, FW-H method without turbulence-induced noise and permeable FW-H method that is able to calculate turbulence- induced noise were compared in order to show turbulence effect.

OFDM Modulation Transmission Characteristic of Acoustic Signal on Power Line Channel (전력선 채널에서 음향신호의 OFDM 변조 전송 특성)

  • Heo, Yoon-Seok
    • The Journal of Information Technology
    • /
    • 제6권4호
    • /
    • pp.1-9
    • /
    • 2003
  • This paper is about power line communication(PLC) over the low power voltage grid. The main advantage with power line communication is the use of an existing infrastructure. The PLC channel can be modeled as having multi-path propagation with frequency-selective fading, typical power lines exhibit signal attenuation increasing with length and frequency. OFDM(Orthogonal Frequency Division Multiplexing) is a modulation technique where multiple low data rate carriers are combined by a transmitter to form a composite high data rate transmission. The performance in consideration of the multi-path(echoes) powerline scheme is analyzed and verified by computer simulation.

  • PDF