• Title/Summary/Keyword: Acoustic Measurement

Search Result 896, Processing Time 0.027 seconds

Study on sound radiation estimation using a reciprocity technique and p-p method by finite element simulation (상반성 기법과 p-p method를 이용한 구조물 방사소음 유한요소해석 기법 연구)

  • Ji Woo Yoo;Hun Park;Ji Un Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.1-6
    • /
    • 2023
  • Sound radiated from a structure in vibration is an important physical characteristic to evaluate vibro-acoustic problem. Although sound radiation power can be typically obtained by intensity measurement, long measuring time and strict measuring condition remain difficult. As an alternative method, simulation-based estimation can be taken into account and its accuracy is known to be acceptable. However, difficulty still lies in that specialized softwares may be necessary to obtain sound radiation power and radiation efficiency. In this context, this study suggests two methods using an ordinary FE method to calculate sound radiation power. They are well-known reciprocity technique and p-p method, which are basically test methods. It is shown that either method can practically estimate sound radiation in the frame of conventional Finite Element Method (FEM). The methods and their corresponding limit are discussed with some results.

Improvement of evaluation method for impact sound reduction performance of floor coverings (바닥 상부 마감재의 충격음 저감성능에 대한 평가방법 개선)

  • Jin-Yun Chung;Han-Sol Song;Guk-Gon Song;Yong-Jin Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.161-167
    • /
    • 2023
  • Recently, floor impact sound has become a serious social problem in Korea. There is an increasing need to improve floor impact sound performance using floor covering installed on the floor of apartment houses. KS F ISO 717-2 and KS F 2863 require measurement under conditions in which the resilient material is not installed. But most apartment houses in Korea install resilient materials to reduce floor imapct sound. The performance evaluation method of floor covering should provide reduced performance for use by residents of apartment houses with resilient materials. Therefore, this paper proposes a reduction performance evaluation under the conditions in which a resilient material is installed to verify the performance of floor covering.

Reservoir water surface slope measurement (저수지 수면경사 실측)

  • HwangBo, Jong-Gu;Oh, Seung Hyun;hong, jun hyuk;Kang, JinSung;Park, Dong Wan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.267-267
    • /
    • 2022
  • 댐 운영에 있어서 필요한 수문자료는 강수량, 수위, 유량, 저수량 자료 등이 있다. 이중 저수량은 주로 댐수위-저수용량 곡선식을 이용하여 계산한다. 댐수위-저수용량 곡선식은 댐 부근에서 계측 되는 한 개의 수위자료를 이용하여 저수용량을 산정하며, 이는 큰 저수지 면적과 저수지 수면이 일정하지 않다는 것을 고려할 때 큰 오차가 발생할 수 있다. 본 연구에서는 음향 도플러 유속계 ADCP(Acoustic Doppler Current Profiler) 이용하여 보성강댐 저수지 수면경사를 실측하고, 동시에 실시간 이동측위시스템인 RTK-GPS(Real Time Kinematic)를 이용하여 이를 검증하였다. ADCP는 유수의 흐름을 방해하지 않으면서 수중에 발사된 음파의 도플러 효과를 이용하여 유속, 유량 및 측량이 가능한 장비이며, RTK-GPS의 경우 정밀한 위치정보를 가지고 있는 기준국의 위상에 대한 보정치를 실시간으로 이용하여 오차가 ±0.03m 이하인 것으로 알려졌다. 보성강댐의 하류에서 ADCP와 RTK-GPS를 장착한 보트를 저수지 종방향으로 처음부터 끝까지 이동하여 약 7.5km 종단측량을 실시하였고 저수지 지형적 특성을 고려하여 약 700m마다 횡단측량을 실시하여 종방향뿐만 아니라 횡방향 수면차도 조사하였다. 그 결과 보성강댐의 상류로 갈수록 수면경사가 전체적으로 상승하는 경향을 보였지만 일부구간에서 수위가 하강하는 경우도 발생하였다. 이는 미약하지만 저수지 내에 흐름이 발생하고 이 흐름에 따른 통제가 변화되는 것과 중간에 유입되는 지류의 영향 등으로 구간별로 수면경사 차이가 발생하는 것으로 추정된다. 횡방향 수면차는 지류가 유입되는 일부구간에서 다소 차이를 보였지만 큰 영향을 없는 것으로 판단된다. 보성강댐 저수지 수면을 종방향 및 횡방향으로 실측한 결과 구간별로 차이를 보였으며 최대 EL. 126.60m, 최소 EL. 126.33m 나타났다. 댐 상류 부근의 수면높이 EL. 126.50m와 비교하면 +0.10m, -0.17m 차이를 보였으며 이는 저수량 산정에 큰 오차를 발생시킨다. 효과적인 댐 운영을 위해서는 유입량 및 유출량을 정확하게 산정하는 것도 필요하지만 저수량을 정확하게 파악하는 것 역시 필요하다. 저수량을 정확하게 산정하려면 수킬로미터가 넘는 저수지 크기를 고려하여 수면경사를 실시간으로 계측하는 등의 노력이 필요한 것으로 판단된다.

  • PDF

Deep learning-based approach to improve the accuracy of time difference of arrival - based sound source localization (도달시간차 기반의 음원 위치 추정법의 정확도 향상을 위한 딥러닝 적용 연구)

  • Iljoo Jeong;Hyunsuk Huh;In-Jee Jung;Seungchul Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.2
    • /
    • pp.178-183
    • /
    • 2024
  • This study introduces an enhanced sound source localization technique, bolstered by a data-driven deep learning approach, to improve the precision and accuracy of direction of arrival estimation. Focused on refining Time Difference Of Arrival (TDOA) based sound source localization, the research hinges on accurately estimating TDOA from cross-correlation functions. Accurately estimating the TDOA still remains a limitation in this research field because the measured value from actual microphones are mixed with a lot of noise. Additionally, the digitization process of acoustic signals introduces quantization errors, associated with the sampling frequency of the measurement system, that limit the precision of TDOA estimation. A deep learning-based approach is designed to overcome these limitations in TDOA accuracy and precision. To validate the method, we conduct comprehensive evaluations using both two and three-microphone array configurations. Moreover, the feasibility and real-world applicability of the suggested method are further substantiated through experiments conducted in an anechoic chamber.

Experimental and clinical studies with impedance audiometry; the increase in air volume in the middle ear air system and the pneumatization of human temporal bones (측두골의 함기도와 중이강의 용적이 고막 임피던스에 미치는 영향에 관한 연구)

  • 민양기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.4.4-5
    • /
    • 1977
  • The vibratory energy introduced into the external ear canal is changed by the mechanical factors of eardrum itself, the motility of ossicles, and the air cushion of tympanic cavity and the like. This study was designed to investigate the volume of middle ear cavity and mastoid air cell system as a factor of determining the accoustic impedance of middle ear system. The author studied how the increase in air volume of middle ear cavity effects on the acoustic impedance of middle ear system with dogs' ears and researched the correlation between the degree of pneumatization of temporal bones and the acoustic impedance of middle ear system by comparing the radiological findings of pneumatization (Law's and Towne's projection) with the acoustic impedance measurements with Madsen ZO 70. The result is as follows: 1 The tympanometric findings in control state revealed the curves of type A, and did not change in its configuration by the increase in the air volume of dogs middle ear system. 2. The static compliance of middle ear revealed a distinct and linear increase in proportion to the increase in air volume of middle ear system; the rate of increase was $0.05{\pm}0.02$ cc of static compliance per cc of air volume. 3. Authenticated in the above result and the tendency to increase in static compliance in proportion to the increase in the degree of pneumatization of temporal bones, there was significant regression equation between the degree of pneumatization of temporal bones (x variable) and the static compliance of middle ear system; $y=0.19x{\pm}0.16{\pm}0.05$ It is suggested that the difference in volume of middle ear system plays an important role in the change of the static compliance of middle ear, and the author concludes that the measurement of static compliance of middle ear has clinical value as diagnostic means of evaluating the degree of pneumatization of temporal bones along with some radiological examination.

  • PDF

Measurement of the Quantity of Hydrogen Peroxide Produced in the Ultrasound-irradiated Aqueous Solution of Organic Compounds (초음파를 조사(照射)한 유기화합물 수용액 속에서의 과산화수소 생성량의 측정)

  • Mo, Se-Young;Chang, Hong-Ki;Lee, Kyung-Jae;Jang, Gun-Eik;Sohn, Jong-Ryeul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.61-71
    • /
    • 2000
  • When irradiate the power ultrasound into the aqueous solutions, water vapor is decomposed by the heat of very high temperature in the cavitation bubble to produce OH (hydroxyl radical) and H (hydrogen radical), and these radicals play a role in decomposing the substances in aqueous solution by oxidation and/or reduction, and in producing the hydrogen peroxide. Accordingly it is possible to predict that the quantity of hydrogen peroxide produced may correlate with the sonolysis mechanism of the substance in aqueous solution. Thus to confirm this prediction, the quantities of hydrogen peroxide produced from each of the air saturated distilled water and three aqueous solutions of TCE, benzene, and 2,4-DCP that are prepared by dissolving them into distilled water are measured. As a result, it showed that the quantity of hydrogen peroxide produced from the distilled water and three aqueous solutions are increased in order of distilled water>TCE solution>2,4-DCP solution>benzene solution, and decrease with decrease in concentration of organic substance, which coincide with the sonolysis mechanisms reported that TCE in aqueous solution is decomposed directly by the pyrolysis in and around the cavitation bubbles when its concentration is high and by the radical reaction when low, however, benzene and 2,4-DCP are decomposed not only by the pyrolysis but also by the radical reactions. Effects of such experimental parameters as the acoustic frequency and power and as the concentration showed that the higher the acoustic frequency and the lower the acoustic power, the less the quantity of hydrogen peroxide was produced. This result coincide with the theory of ultrasound for the relation between the cavitation that is the energy source of the power ultrasound in aqueous solution and these experimental parameters.

  • PDF

A Study on Skin Status with Acoustic Measurements of Skin Friction Noise (피부 마찰 소음 측정을 통한 피부 상태 연구)

  • Chang, Yun Hee;Seo, Dae Hoon;Koh, A Rum;Kim, Sun Young;Lim, Jun Man;Han, Jong Seup;Lee, Sang Hwa;Park, Sun Gyoo;Kim, Yang Han
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Efficacy of cosmetics has been mainly evaluated by qualitative and quantitative methods based on visual sense, tactile sense and skin structure until now. In this study, we suggested a novel evaluation method for skin status based on sound; measuring and analyzing the rubbing noise generated by applying cosmetics. First, the rubbing noise was measured at a close range by a high-sensitivity microphone in anechoic environment, and the noises were analyzed by 1/3 octave band analysis in frequency-domain. Three conditions, 1) before washing, 2) after washing and 3) after application of cosmetics, were compared. As a result, sound pressure level (SPL) of rubbing noise after washing was larger than that of before washing, and the SPL of rubbing noise after cosmetic application was the smallest. Furthermore, the energy of rubbing noise after application was higher than that of the before and after washing conditions in a low frequency band (lower than 2 kHz region). Conversely, the energy of rubbing noise after application was much lower than the others in a high-frequency band (upper than 2 kHz region). This change of energy distribution was described as a balloon-skin model. High SPL in the low frequency region after the cosmetic applications was due to the increase of "flexibility index", while SPL in the high frequency region significantly decreased because of the attenuation which is related to "softness index". Therefore, we developed two indices based on the spectrum-energy difference for evaluating skin conditions. This proposed method and indices were verified via skin flexibility and roughness measurement using cutometer and primos respectively. These results suggest that acoustic measurement of skin friction noise may be a new skin status evaluation method.

Gas Hydrate Exploration Using LWD/MWD in the Ulleung Basin, the East Sea of Korea (LWD/MWD를 이용한 동해 울릉분지 가스하이드레이트 탐사)

  • Kim, Gil-Young;Yoo, Dong-Geun;Kim, Won-Sik;Lee, Ho-Young;Park, Keun-Pil
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.263-270
    • /
    • 2008
  • The Gas Hydrate Research and Development Organization (KGHDO) of Korea accomplished successfully geophysical logging (LWD: Logging While Drilling, MWD: Measurement While Drilling) for five sites in 2007, in order to investigate the presence of gas hydrate in the Ulleung Basin, the East Sea of Korea. The togging parameters acquired from LWD/MWD dre electrical resistivity, acoustic velocity, neutron density and porosity, and natural gamma. In addition, pressure, temperature, and diameter of borehole were measured. LWD/MWD data showed several evidences indicating the presence of gas hydrate. Based on LWD/MWD data, three coring sites were selected for sampling of gas hydrate. Subsequently, various gas hydrate samples were collected directly from three sites. Therefore. the presence of gas hydrates was verified by coring. LWD/MWD data will be significantly used to estimate the amount of gas hydrate. Also, they will provide important information to elucidate about sedimentologic characteristics of gas-hydrate bearing formation and sedimentary environment of the Ulleung Basin.

A Study on the Current Measurement Using birefringence Fiber (복굴절 광섬유를 이용한 전류측정에 관한 연구)

  • Jang Nam-Young;Choi Pyung-Suk;Eun Jae-Jeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.2
    • /
    • pp.59-66
    • /
    • 2005
  • Accuracy of current measurement in fiber optic current sensor(FOCS), especially, unidirectional polarimetric fiber optic current sensor(PFOCS) is affected by the environment perturbations such as acoustic vibrations changes to the sensing fiber, and intrinsic perturbations such as the bending fiber that the sensing fiber wound around a current carrying wire. The perturbations affect the birefringence properties of sensing fiber in sensor head and cause false current readings. Thus, using compensation technique, reciprocal PFOCS, for unidirectional PFOCS the perturbations are suppressed. In this paper, we carried out the numerical analysis of performance in reciprocal PFOCS including the degree of polarization error, and false current of environmental and intrinsic perturbations on the sensing fiber. Also, we compared the effect of mirror with the faraday rotation mirror(FRM) in reciprocal PFOCS configuration. And the different optical source's wavelengths, 633nm and 1300nm is used. In the results, at 633nm, using mirror and FRM, the degree of polarization error is calculated to $2.3\%$ and $0.0196\%$, respectively. At $1300{\cal}nm$ using mirror and FRM the degree of polarization error is calculated to $9.97\%$ and $0.0196\%$, respectively. Also, compared with false current, the results is calculated to $9.82{\times}10^{-9}A$ and $1.4{\times}10^{-17}A$, respectively, and show that the reciprocal PFOCS is more robust configuration than unidiretionnal PFOCS for environmental and intrinsic perturbations.

  • PDF

Measuring Plate Thickness Using Spatial Local Wavenumber Filtering (국소 공간 웨이브넘버 필터링 기법을 이용한 평판 구조물 두께 측정)

  • Kang, To;Lee, Jeong Han;Han, Soon Woo;Park, Jin Ho;Park, Gyuhae;Jeon, Jun Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.370-376
    • /
    • 2016
  • Corrosion on the surface of a structure can generate cracks or cause walls to thin. This can lead to fracturing, which can eventually lead to fatalities and property loss. In an effort to prevent this, laser imaging technology has been used over the last ten years to detect thin-plate structure, or relatively thin piping. The most common laser imaging was used to develop a new technology for inspecting and imaging a desired area in order to scan various structures for thin-plate structure and thin piping. However, this method builds images by measuring waves reflected from defects, and subsequently has a considerable time delay of a few milliseconds at each scanning point. In addition, the complexity of the system is high, due to additional required components, such as laser-focusing parts. This paper proposes a laser imaging method with an increased scanning speed, based on excitation and the measurement of standing waves in structures. The wavenumber of standing waves changes at sections with a geometrical discontinuity, such as thickness. Therefore, it is possible to detect defects in a structure by generating standing waves with a single frequency and scanning the waves at each point by with the laser scanning system. The proposed technique is demonstrated on a wall-thinned plate with a linear thickness variation.