• 제목/요약/키워드: Acoustic

검색결과 8,243건 처리시간 0.051초

수중 모래퇴적물에서 차주파수 음파의 비선형 산란 (Nonlinear Scattering of Difference Frequency Acoustic Wave in Water-Saturated Sandy Sediment)

  • 김병남;이강일;윤석왕;최복경
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 춘계학술발표대회 논문집 제23권 1호
    • /
    • pp.347-348
    • /
    • 2004
  • Nonlinear scattering of difference frequency acoustic wave in a water-saturated sandy sediment was investigated. Difference frequency acoustic wave was observed to be scattered due to the nonlinearity of water-saturated sandy sediment when the collinear acoustic waves with two different fundamental frequencies are incident on the sediment. The pressure level of the difference frequency acoustic wave was 6 dB higher than the background noise level. It seems very useful to evaluate the nonlinear parameter of water-saturated sandy sediment without disturbing the sediment. Such nonlinear acoustic response of water-saturated sandy sediment can be used as background acoustic data for estimating the gas void fraction in marine gassy sandy sedimen.

  • PDF

Audiometric Calibration of Aural Acoustic Immittance Instrument: A Review of Acoustic Immittance Instrument's Calibration

  • Kim, Jin-Dong
    • 대한의생명과학회지
    • /
    • 제22권4호
    • /
    • pp.115-126
    • /
    • 2016
  • Audiometric calibration is a prerequisite for securing the reliability of audiometric test results by checking the internal consistency of the relevant instrument. The purpose of this review is to help instrument operators understand the calibration procedure of aural acoustic immittance instrument which is frequently used for objective assessment. By referring to the latest international standards and the national standards relevant to the aural acoustic immittance instrument, the following parameters will be reviewed: 1) introduction of performance characteristics, 2) detailed procedure of the calibration method. According to the newest international and national standards [IEC 60645-5 (2004), ANSI S3.39-1987 (R2012)], the aural acoustic immittance instrument basically includes six components: 1) calibration cavity, 2) acoustic immittance analysis system, 3) probe assembly/unit and signal, 4) pneumatic air-pressure pump system, 5) acoustic reflex activator system and 6) tympanogram and acoustic reflex plotting system, each of these components should meet set standards. The result of behavioral hearing tests is influenced by various complex factors including the examinee's cooperation, background noise of the examination room, measurement method, skill level of the audiologist and calibration status, but the objective hearing tests is more influenced by the calibration status of the instrument than any other factors. The audiologist should take full responsibility for the reliability of the hearing test result, so he/she should carry out the calibration check and adjustments of aural acoustic immittance instrument periodically and maintain the instrument continuously by referring to the newest standards and the manufacturer's instruction manual.

FE-BEM 및 SEA 해석 기법을 활용한 샌드위치 복합재 구조물의 전 주파수 대역 음향 해석 (Full-Frequency Band Acoustic Analysis of Sandwich Composite Structure Using FE-BEM and SEA Method)

  • 이대은;이윤규;김홍일;김재영
    • 한국군사과학기술학회지
    • /
    • 제21권4호
    • /
    • pp.422-428
    • /
    • 2018
  • Increase in use of lightweight structures, coupled with the increased acoustic loads resulting from larger and longer range guided missiles, has made missile more susceptible to failures caused by acoustic loads. Thus, accurate prediction of acoustic environment and the response is becoming ever more important for mission success. In this paper, the acoustic response of a sandwich composite skin structure to diffuse acoustic excitation is predicted over a broad frequency range. For the low frequency acoustic analysis, coupled FE-BEM method is used where the structure is modeled using FEM and the interior and exterior fluid is modeled using BEM. For the high frequency region, statistical energy analysis is applied. The predicted acoustic level inside the structure is compared with the result from acoustic test conducted in reverberation chamber, which shows very good agreement.

Comparison of Predicted Acoustics with the Measured Acoustic Properties of a Multi-Purpose Hall

  • Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • 제25권3E호
    • /
    • pp.95-100
    • /
    • 2006
  • The present study presents the design procedures and the acoustic properties of the main hall of Ansan Cultural Arts Center in Korea which has opened in 2004. The acoustic design values are compared with the measured acoustic properties of the completed multi-purpose hall. Acoustic design criteria were suggested in the design stage through the 3-dimentional computer simulations. The acoustic parameters including SPL, RT, C80, $D_{50}$M, RASTI were measured in the hall after completed. Acoustic measurements were carried out in the 40 measurement points using MLS sound source signal in 4 different sound source points. The results show the even distribution of sound levels within the 2.0dB of difference among all seats. The reverberation time of 1.66sec was measured which is similar to the objective value of 1.65 sec in empty states. It was also found that average C80 values lie in the objective extents of C80 from -1 to 3dB and average D50 value of 54 was measured. Thus, it is concluded that the hall can be used as a multi-purpose hall with a suitable acoustic conditions.

가청화를 이용한 돔형 체조연습장의 음향 성능평가에 관한 연구 (Evaluation of Acoustic Performance about Dome-typed Gymnastics Training Floor Using Auralization)

  • 윤재현;주덕훈;김재수
    • 한국소음진동공학회논문집
    • /
    • 제17권8호
    • /
    • pp.708-719
    • /
    • 2007
  • In case of indoor gymnastics training floor, in view of its characteristics, since it is simultaneously required the related smooth communication between the coach and the player, also the acoustic performance regarding to the clearness of music, besides the sport activity, the consideration about the acoustic character has entered the stage as an indispensable element. On such viewpoint, recently constructed dome-typed gymnastic training floor was optimized acoustic design with remodeling through acoustic simulation test. And acoustic satisfaction degree and reaction was attempted to investigate about the gymnastics training floor estimating value of human's psychological(sensual) degree using auralization that enables to experience the virtual sound field at the stage of design. As the result of investigation about the research on the space of object, it could be known that the valuation regarding to the acoustic performance of 'after-improvement' was distinctly more refined than that of 'before-improvement'. It is now considering that such result of the study can be utilized as the useful data which enables to improve the retrenchment effect of the construction cost as well as the acoustic capability, by means of the prediction control on the acoustic problem from the stage of design, for the occasion when the similar indoor sport gymnasium is planning to build for the near future.

원통형 배열센서 후면 구조물에 의해 발생하는 허위 표적 감소를 위한 음향 배플 연구 (A Study on the Acoustic Baffle to Reduce Ghost Target According to Structure behind Cylindrical Array Sensor)

  • 서영수;김동현;김진태
    • 한국소음진동공학회논문집
    • /
    • 제25권6호
    • /
    • pp.440-446
    • /
    • 2015
  • Acoustic signal is emitted from a vessel and received by a cylindrical array sensor at some distance from the vessel. Acoustic signal is the source for a cylindrical array sensor which is designed to detect the acoustic signal. Cylindrical array sensors seldom have an ideal hydrodynamic shape and are not sufficiently robust to survive without some protection and they are normally housed in a sonar dome. Reflected signals by some structure inside a sonar dome make unwanted signals. Therefore, an acoustic baffle is used to minimize unwanted signals. The performance of the acoustic baffles can be determined from the acoustic numerical analysis at the design stage. In this study, finite element method was used to analyze the acoustic field around the cylindrical array sensor and baffle effects. The baffle performance can be defined the echo reduction. To show the baffle performance, the specimens were made for pulse tube test and echo reductions were measured during the test. In this paper, the effect of echo reduction of the acoustic baffle was discussed.

음향 반사판의 밀도별 흡음특성 및 무대음향에의 영향 (Effect of Acoustic Reflector's Surface Density on Sound Absorption Characteristics and Stage Acoustics)

  • 김영선;정정호;전진용;김명석
    • 한국소음진동공학회논문집
    • /
    • 제22권5호
    • /
    • pp.429-436
    • /
    • 2012
  • In concert halls and auditoriums, acoustic reflector and stage enclosure is one of the main factors on the room and stage acoustic characteristics. As a stage enclosure and acoustic reflector honey comb based light-weight reflector is widely used, because it is easy to install. However, there was not enough research on the surface density effect on room and stage acoustics. In this study, sound absorption coefficient tests on three kinds of wooden acoustic reflectors with different surface density were conducted. Surface density of acoustic reflector was changed from 11 kg/$m^2$ to 41 kg/$m^2$. For the low frequency excitation, sub-woofer was used with omnidirectional loud-speaker simultaneously. From the experiments, it was found that sound absorption coefficient below 250 Hz band was decrease by the increment of surface density. In order to check the influence of the surface density on room and stage acoustic parameters, room acoustic simulation was conducted with sound absorption coefficients, which were tested in reverberation chamber. By the increment of surface density of acoustic reflector, RT(reverberation time) and EDT(early decay time) were increased. Also, ST(stage support) was improved in low frequency bands.

Acoustic correlates of prosodic prominence in conversational speech of American English, as perceived by ordinary listeners

  • Mo, Yoon-Sook
    • 말소리와 음성과학
    • /
    • 제3권3호
    • /
    • pp.19-26
    • /
    • 2011
  • Previous laboratory studies have shown that prosodic structures are encoded in the modulations of phonetic patterns of speech including suprasegmental as well as segmental features. Drawing on a prosodically annotated large-scale speech data from the Buckeye corpus of conversational speech of American English, the current study first evaluated the reliability of prosody annotation by a large number of ordinary listeners and later examined whether and how prosodic prominence influences the phonetic realization of multiple acoustic parameters in everyday conversational speech. The results showed that all the measures of acoustic parameters including pitch, loudness, duration, and spectral balance are increased when heard as prominent. These findings suggest that prosodic prominence enhances the phonetic characteristics of the acoustic parameters. The results also showed that the degree of phonetic enhancement vary depending on the types of the acoustic parameters. With respect to the formant structure, the findings from the present study more consistently support Sonority Expansion Hypothesis than Hyperarticulation Hypothesis, showing that the lexically stressed vowels are hyperarticulated only when hyperarticulation does not interfere with sonority expansion. Taken all into account, the present study showed that prosodic prominence modulates the phonetic realization of the acoustic parameters to the direction of the phonetic strengthening in everyday conversational speech and ordinary listeners are attentive to such phonetic variation associated with prosody in speech perception. However, the present study also showed that in everyday conversational speech there is no single dominant acoustic measure signaling prosodic prominence and listeners must attend to such small acoustic variation or integrate acoustic information from multiple acoustic parameters in prosody perception.

  • PDF

전기-음향 방사컨덕턴스를 이용한 치료용 초음파 자극기의 음향출력 예측 (The Acoustic Output Estimation for Therapeutic Ultrasound Equipment using Electro-Acoustic Radiation Conductance)

  • 윤용현;조문재;김용태;이명호
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.264-269
    • /
    • 2011
  • To increase therapeutic efficiency and biological safety, it is important to precision control of acoustic output for therapeutic ultrasound equipment. In this paper, the electro-acoustic radiation conductance, one of electroacoustic characteristics of therapeutic ultrasound equipment, was measured by the radiation force balance method according to IEC 61161 standards and the acoustic output was estimated using the electro-acoustic radiation conductance. The estimation of acoustic output was conducted to continuous wave mode and pulse wave mode of duty cycle between 20% and 80%. The differences between prediction values and measurement results are within 5% of measurement uncertainty, which is a reasonably good agreement. The results show that acoustic output controlled by electro-acoustic radiation conductance was found to be an effective method.

75MW 급 발전용 보일러 관군에서의 음향공진에 의한 진동/소음 사례연구 (A Case Study on the vibration and noise by acoustic resonance in the tube bank of a boiler of 75MW power plant)

  • 김철홍;방경보;주영호;변형현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.150-155
    • /
    • 2000
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a power plant. Acoustic resonance is may arise when the vortex shedding frequency coincides with the acoustic natural frequency. At the resonance, the value of vibration in this system was 595 ${\mu}m$, p-p and the sound pressure level was maximum 103 dBA. And the resonance frequency was found to be 35 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance is possible. In this system, the difference of these frequencies was 1.8%. We can evaluate the possibility of acoustic resonance by using damping parameter. We did eliminate acoustic resonance by installing baffle in tube bank. After installing baffle, the level of vibration and noise was reduced dramatically.

  • PDF