• Title/Summary/Keyword: Acid graft

Search Result 202, Processing Time 0.027 seconds

Radiation-Induced Graft Copolymerization of Hydrophilic Monomers to Polyester

  • Lee, Chong-Kwang;Park, Jae-Ho
    • Nuclear Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.90-101
    • /
    • 1972
  • Radiation grafting of acrylic acid to Polyester fabric has been studied by an impregnation method to render its surface more hydrophilic. Impregnated fabric was irradiated under nitrogen with gamma-ray from Co-60. The homopolymer formed usually could be extracted with water at 10$0^{\circ}C$. Graft-fabric exhibited a good acceptability to acid, basic or disperse dyes in conventional aqueous dye bath at moderate temperature.

  • PDF

The Graft Polymerization of Acrylic Acid in Vapour Phase onto Poly(ethylene terephthalate) by Cold Plasma Part (I) (저온 Plasma를 이용한 Poly(ethylene terephthalate)에의 Acrylic Acid의 기상 Graft 공중합 반응(I))

  • 천태일;최석철;모상영
    • Textile Coloration and Finishing
    • /
    • v.1 no.1
    • /
    • pp.7-18
    • /
    • 1989
  • The distinguishing characteristic of the glow discharge is that chemical reaction induced by partially ionized gases are limited only to the substrate surface. Most studies have been done on the plasma etching and polymerization. The graft polymerization in vapour phase by cold plasma has been rarely investigated. In this study the system of tub3ar reaction chamber with capacitively coupled electrode of alternative current of 60 Hz was employed for the graft polymerization. The graft polymerization of Acylic Acid(AA) onto the poly (ethylene terephthalate) (PET) was carried out by treatment of PET film and fabric by cold plasma (glow discharge of argon gas), followed by the supply of AA vapour. The graft yield was about 1 wt%. The surface property was determined by contact angle, the surface tension was evaluated by zisman’s plot and equation of surface tension mesurement. The results were as follows: 1. In order to obtain lower contact angle, it was effective to avoid the vicinity of electrodes for a setting position of substrate. 2. Contact angle affected on the monomer pressure and its duration of exposure to the acid vapour. 3. Polymer radical formation was influenced by the changes of the value of current density and plasma treatment time. 4. Total surface tension of plasma grafted PET film increased. With an increase in the carboxylic acid content, the dispersion force decreased, while, the polar force and hydrogen bonding force increased. 5. The contact angle decreased from $75^\circ$ to around $30^\circ$ by plasma grafting. There was no ageing effect on the contact angle after 4 months.

  • PDF

Nerve Regeneration Using a Vein Graft Conduit filled with Hyaluronic Acid in a Rat Model (흰쥐 모델에서 하이알루론산을 채운 정맥도관의 신경재생에 관한 연구)

  • Suh, Bo Ik;Kim, Sang Woo;Chung, Ho Yun;Kim, Il Hwan;Yang, Jung Dug;Park, Jae Woo;Cho, Byoung Chae
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.279-284
    • /
    • 2007
  • Purpose: The vein graft was considered as a useful conduit for nerve defect. But the problem is that it might be collapsed in long vein graft state. A new experimental model using vein graft filled with hyaluronic acid was considered. Methods: Thirty rats were used for the experimental animal. In group I, one side of the femoral nerve was exposed and a segment was removed about 15mm. The neural gap was connected with nerve graft. In group II, the nerve gap was connected with vein graft only. In group III, the nerve gap was connected with vein graft filled with hyaluronic acid. A walking track analysis was made periodically for 2 months and NCV(nerve conduction velocity) was executed at the end of the experiment. And morphologic studies were also done for all groups Results: In a walking track analysis, the toe-spread was widen and the foot-length was lengthened. The recovery of the toe-spread and foot length was checked 2 weeks interval, periodically for two months. The SFI (sciatic function index) was $-52.5{\pm}8.2$ in group I, $-68.1{\pm}4$ in group II, $-55.3{\pm}7.9$ in group III. In electrophysiological study, NCV(nerve conduction velocity) was $26.71{\pm}3.11m/s$ in group I, $17.94{\pm}4.35m/s$ in group II, $25.69{\pm}2.81m/s$ in group III. The functional recovery in group I and III was superior to that the group II statistically(p < 0.05) Under electromicroscopic study, the number of the myelinated axons were $1419.1{\pm}240$ in group I, $921.7{\pm}176.8$ in group II, $1322.2{\pm}318$ in group III. The number of the myelinated axons were much more in group I and III than group II statistically (p<0.05). Conclusion: This study suggested that the vein graft filled with hyaluronic acid is more effective than vein graft only for the conduit of the nerve gap. It was thought that the technique could be used in clinical cases with nerve defects as an alternative method to classical nerve grafts.

Self-Aggregated Nanoparticles of Lipoic Acid Conjugated Hyaluronic Acid (히알루론산에 결합된 리포산 자기조립체의 제조 및 특성)

  • Hong, In-Rim;Kim, Young-Jin
    • Polymer(Korea)
    • /
    • v.32 no.6
    • /
    • pp.561-565
    • /
    • 2008
  • Hyaluronic acid (HA) is a natural glycosaminoglycan and is used widely in the pharmaceutical field. Lipoic acid (LA) helps the regeneration of exogenous and endogenous antioxidants such as Vitamin C and Vitamin E as well as glutathione. It also acts as antioxidant indirectly. Hydrophilic HA as a biodegradable and biocompatible polymer was conjugated with hydrophobic LA as an antioxidant to form the graft copolymer. The carboxyl group of HA was modified by adipic acid dihydrazide (ADH). The synthesis of HA-g-LA graft copolymers was characterized by FT-IR, $^1H$-NMR spectroscopy. The conjugates could form the self-assembled nanoparticles in aqueous solution. The particle size and critical aggregation concentration were verified to use the nanoparticle as a carrier fur the hydrophobic material.

A Study on the Immobilization of Biomolecules on Poly(acrylic acid)-grafted MWCNTs Prepared by Radiation-Induced Graft Polymerization (방사선 그래프트 중합에 의하여 제조된 폴리(아크릴 산)이 그래프트된 탄소나노튜브에 생체분자 고정화에 관한 연구)

  • Jung, Chan-Hee;Lee, Byoung-Min;Hwang, In-Tae;Choi, Jae-Hak;Nho, Young-Chang;Hong, Sung-Kwon
    • Polymer(Korea)
    • /
    • v.34 no.2
    • /
    • pp.150-153
    • /
    • 2010
  • In this research, biomolecule-immobilized multi-walled carbon nanotubes (MWCNTs) were prepared by using radiation-induced graft polymerization. For the immobilization of biomolecules, the surface of MWNCTs was functionalized by radiation-induced graft polymerization of acrylic acid. Based on the results of TGA and Raman spectroscopy it was found that acrylic acid was effectively graft-polymerized on the MWCNTs. Biomolecules such as DNA and proteins were immobilized onto the resultant poly(acrylic acid)-grafted MWCNTs. The results of the X-ray photoelectron spectroscopy and fluorescence microscopy confirmed that the biomoelcules were successfully immobilized on the poly(acrylic acid)-grafted MWCNTs.

A Study on the Preparation and Hydrophilization of Polypropylene Microfiltration Membrane by Radiation-Induced Graft Polymerization (방사선 중합에 의한 폴리프로필렌 정밀여과막의 제조 및 친수화 거동에 관한 연구)

  • 황택성;이선아;황의환
    • Polymer(Korea)
    • /
    • v.24 no.5
    • /
    • pp.621-628
    • /
    • 2000
  • Microporous polypropylene (PP) membranes have the high chemical and corrosion resistance, the good mechanical properties and the thermal stability under high temperatures, but its application is restricted within narrow limits due to hydrophobicity of membranes. In order to impart permanent hydrophilicity to the PP microfiltration membrane, the radiation-induced graft of 2-hydroxyethyl methacrylate (HEMA) and acrylic acid (AAc) containing hydrophilic functional group onto the membrane has been studied. The effect of graft conditions such as reaction time, total radiation dose, reaction temperatures, acid compositions on graft yield was investigated. Modified PP membranes were shown to cause an increase in the gas flux. Oil emulsion permeation flux of both original PP membrane and modified PP membrane was examined.

  • PDF

Graft Copolymerization of MMN4-Vinylpyridine onto Cotton Fiber (면섬유(綿纖維)에의 MMA/4-Vinylpyridine의 공(共)그라프트 중합(重合))

  • Bae, Hyun-Sook;Kim, Sung-Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.3
    • /
    • pp.347-358
    • /
    • 1993
  • Graft copolymerization of MMN4-VP onto cotton fiber using Ce(IV) salt as an initiator and triton X-100 as an emulsifier was performed under various polymerization conditions. In cograft polymerization, the polymeization behavior according to variation of 4-VP feed composition and the characteristics of MMA/4-VP graft polymer such as affinity for acid dye owing to cationization of cotton, antibacterial activity and thermal behavior were investigated. The results of this study were as follows : 1. While in copolymerization of MMA and 4-VP, 4-VP content in copolymer was more than that of monomer feed composition. 2. Increasing 4-VP content, graft yield was decreased, but graft efficiency was increased. In case of MMA/4-VP graft polymerization, the highest graft yield was obtained at higher CAN concentration than in MMA graft polymerization, the reason is that the behavior of 4-VP was disturbed by Ce(IV) sail 3. Elevation of temperature resulted in increase of graft yield and the apparent activation energy of MMA/4-VP graft polymerization was higher than that of MMA graft polymerization. 4. MMA/4-VP grafted cotton fiber showed affinity for acid dye, antibacterial activity and higher moisture regain than MMA grafted cotton fiber. MMA/4-VP grafted cotton fabric showed improvement of wrinkle recovery up to 40~50% graft yield and decreased thereafter. MMA/4-VP and MMA grafted cotton fabric did not showed significant difference in wrinkle recovery and stiffness.

  • PDF

Radiation-Induced Graft Copolymerization of Hydrophilic Monomer onto Nylon 6

  • Choi, Jae-Ho;Lee, Chong-Kwang;Lee, Kwang-Jin
    • Nuclear Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.161-169
    • /
    • 1974
  • Radiation grafting of acrylic acid onto nylon fabric has been studied by "simultaneous irradiation" method to render its surface more hydrophilic. Nylon fabric immersed in monomer solution was irradiated in air or under vacuum with gamma-rays from Co-60. Most parts of polyacrylic acid formed on the surface of the fabric were extracted off from the fabric with 0.1% solution of sodium hydroxide at 10$0^{\circ}C$. The chemical components of the grafted product have been determined. By comparing graft polymer with ungrafted polyamide, the rate of water absorption and antistatic behavior are improved. improved.

  • PDF

THE EFFECT OF HYALURONIC ACID ON XENOGRAFT IN RAT CALVARIAL DEFECT (백서 두개부 결손부에 이식된 이종골 치유과정에 히알루론산이 미치는 영향에 관한 연구)

  • Jo, I-Su;Min, Seung-Ki
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.3
    • /
    • pp.205-215
    • /
    • 2002
  • The purpose of this study was to evaluate the tissue response in various bone grafting materials, especially xenogenous bone materials in vivo, compare of bone formation capacity of various bone grafting materials on rat skull defects and evaluate the effect of Hyaluronic acid on healing of human Demineralized Freezed Dried Bone allogenous graft (DFDBA) materials in rat calvarial defects. 30 Sprague-Dawly rats were divided into 4 groups. $7{\times}7mm$ size bony defect were artificially prepared in the calvaria (both parietal bone) of all 30 rats and follwed group grafting of autogenous bone graft on right side and allogenic DFDBA on left side bone graft (rat DFDB) in 15 control group, but in 15 experimental group, xenograft (human DFDB) on left side, hyaluronic acid treated with xenograft on right side. Sequential sacrifices was performed at 1, 2, 4, 6, 8 weeks of experiment. These specimens were stained with H&E and MT stain, and then histologic analysis under light microscope was carried out. There were inflammatory reaction in all graft material during early stage. Autogenous and Allogenous DFDBA graft group observed inflammatory reaction at 1 week. Xenograft group persistant inflammatory reaction until 4 weeks, but in HA treated xenograft group inflammatory reaction was decreased at 2 weeks. Osteoblastic activity in control group was begun at 2 week, xenograft group was delayed at 6 weeks, however HA treated xenograft group was begun at 4 weeks. At 2 week, mild osteoclastic activity were observed in all xenograft group not in concerned to HA, but there was no difference each group after 4 weeks. There are most activated angiogenesis around graft mateirals in xenograft group at 2 weeks, but in HA treated xenograft group, decreased angiogenesis was observed at same time. Bone formation and bone maturation of xenograft group, there was no difference in HA treatment, was less than control group. Fibrosis around xenograft materials were observed until 6 weeks, there was no difference between xenograft and HA treated groups.

Sericin- Fixation of Raw Silk by Graft Copolymerization (Graft 공중합에 의한 생사 Sericin 정착)

  • 김신덕
    • Journal of Sericultural and Entomological Science
    • /
    • v.20 no.2
    • /
    • pp.40-44
    • /
    • 1978
  • Cerium (IV) ion-initiated graft copolymerizations of acrylonitrile to raw silk were investigated in an effort to carry out sericine-fixation. The change in ceric ammonium nitrate concentration exhibited a maximum in percentage of grafting at 0.003M. Also observed was that the change in nitric acid content in reaction media gave a maximum in percentage of grafting at 0.1M. Percentage of grafting was increased generally with increase in acrylonitrile concentration, reaction time and reaction temperature. Raw silk sericin grafted with acrylonitrile was not de gummed by boiling off test and optimum graft percentage was considered at 20%.

  • PDF