• 제목/요약/키워드: Acid digestion method

검색결과 153건 처리시간 0.026초

국내 토양오염 공정시험방법중 중금속 관련 오염평가의 문제점과 개선책 (The controversial points and a remedy on evaluation of heavy metal contamination in standard method for examination of soil in Korea.)

  • 오창환;유연희;이평구;박성원;이영엽
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.298-301
    • /
    • 2000
  • Heavy metals are extracted from stream sediments, roadside soils and sediments and soils and tailings from mining area using partial extraction, acid digestion and HF-digestion. Compared to amounts of heavy metals extracted using partial extraction, those extracted using acid digestion are higher by 2.0∼220.9 times in Cu, 2.4∼2806.1 times in Pb, 1.3∼121 times in Cd, 14.1∼1300885 times in Fe, 1.2∼271.5 times in Mn, 1.3∼372.5 times in Zn, 2.2∼1734.5 times in Cr. Although partial extraction, which extracts less amounts of heavy metals from soil compared to acid digestion, is used in domestic standard method for examination of soil, domestic soil standard for heavy metals in non-agricultural and industrial areas is higher than soil standard in foreign countries which use acid digestion, For improvement of the domestic standard method for assessment of soil, it is suggested to lower the domestic soil standard for heavy metals or to change pretreatment method for extracting heavy metals from partial extraction to acid digestion with modifying the soil standard.

  • PDF

국내 토양오염 공정시험방법중 중금속 관련 오염평가의 문제점과 개선책 (The controversial points and a remedy on evaluation of heavy metal contamination in standard method for examination of soil in Korea.)

  • 오창환;유연희;이평구;박성원;이영엽
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제6권1호
    • /
    • pp.63-83
    • /
    • 2001
  • 하천, 고속도로 주변, 광산지역으로부터 채취된 시료를 대상으로 용출법과 산분해법, 완전용해법의 세가지 전처리 방법을 적용하여 중금속을 추출하고 그 결과를 비교하였다. 전처리방법으로 용출법 사용시 중금속 추출량에 비해 산분해법 사용시의 중금속 추출량이 Cu는 2.0∼221배, Pb는 2.4∼2806배, Cd는 1.3∼121배, Fe는 14.1∼1300885배, Mn은 1.2∼272배, Zn은 1.3∼373배, Cr은 2.2∼1735배 높게 나타났다. 용출법에 의한 중금속 추출량과 산분해법에 의한 중금속 추출량간에 특별한 상관관계가 없다. 이에 반해 산분해법 사용시 중금속 추출량과 완전용해법 사용시 중금속 추출량간에는 다소 상관관계가 있을 가능성이 있다. 국내와 국외의 비농경지 및 공장·산업지역 토양오염 기준치를 비교하여 볼 때 중금속(Cd, Cu, Pb)이 상대적으로 적게 추출되는 용출법을 사용하는 국내의 기준치가 중금속이 상대적으로 많이 추출되는 산분해법을 사용하는 외국의 기준치 보다 낮아야 함에도 불구하고 국내의 기준치가 외국보다 대부분 높게 책정되어있다. 개선책으로 용출법을 계속 적용하되 기준치를 낮추거나 아니면 전처리방법을 산분해법으로 바꾸고 기준치를 재조정하는 것이 필요하다.

  • PDF

포장용지류에서의 중금속 분석을 위한 산분해 전처리 방법의 탐색 (Considerations of Acid Decomposition System for the Analysis of Heavy Metals in Packaging-grade Paper)

  • 이태주;고승태;김형진
    • 펄프종이기술
    • /
    • 제43권1호
    • /
    • pp.65-73
    • /
    • 2011
  • The fibrous raw materials in packaging-grade paper production in Korea were mainly obtained from waste paper. The use of recycled paper has both positive and negative impacts in papermaking process. The primary positive impacts are the environmental protection and manufacturing cost reduction, and the negative impacts are the quality reduction in paper quality and the accumulation of heavy metals and other pollutants in wet- and dry-end process. This study was carried out to consider the optimum acid decomposition system with the highest recovery rate for the analysis of heavy metals in packaging-grade paper. The open digestion system using Kjeldahl apparatus and the closed digestion system using microwave oven for decomposing the organic materials in paper were compared. In both open and closed digestion method, the combination of nitric acid, hydrochloric acid and hydrogen peroxide showed higher recovery rate than using only nitric acid alone because the presence of Cl- ions in hydrochloric acid stabilizes ligand formation with metal ions. KOCC was observed to have the highest heavy metal content among the recycled paper samples. The heavy metal contents decomposed with the closed digestion system were relatively higher than with open digestion system.

실리콘 웨이퍼 중의 금속 불순물 분석을 위한 시료 전처리 (Sample Pretreatment for the Determination of Metal Impurities in Silicon Wafer)

  • 정혜영;김영훈;유학도;이상학
    • 대한화학회지
    • /
    • 제43권4호
    • /
    • pp.412-417
    • /
    • 1999
  • 실리콘 웨이퍼 중의 금속 불순물을 유도결합플라스마-질량분석기(ICP-MS)로 분석하기 위한 시료의 전처리 방법으로 마이크로파 분해법과 산분해법을 비교하였다 $HNO_3$-HF 혼합용액을 실리콘 웨이퍼 시료에 가하고 마이크로파 분해법과 산분해법으로 용해시킨 후, 용액의 실리콘 매트릭스는 증발 용기 안에서 Si-F의 형태로 증발시켜 분석하였다. 실제 시료에 spike한 Ni, Cr 및 Fe의 회수율은 두 전처리 방법에서 95∼106%였다. Cu의 경우는 산분해법이 회수율이 더 좋았고, Zn의 경우는 마이크로파 분해법으로 전처리 한 경우의 회수율이 더 좋았다. Spin coater로 Fe를 오염시킨 실리콘 웨이퍼를 산분해법과 마이크로파 분해법으로 전처리하여 ICP-MS로 분석한 결과, Fe의 농도는 위의 두 전처리 방법에서 거의 차이가 없었다.

  • PDF

용접흄내 중금속분석시 전처리 방법별 효율비교 (A Comparison of Efficiency of Two Pretreatment Methods for Extracting Heavy Metals from Welding Fume Samples)

  • 손두영;김현욱
    • 한국산업보건학회지
    • /
    • 제9권2호
    • /
    • pp.135-144
    • /
    • 1999
  • The purposes of this study were to survey types of pretreatment methods adopted by industrial hygiene laboratories in Korea for extracting heavy metals in welding fume samples and to compare performances of two pretreatment methods, the acid extraction and the microwave digestion, in extracting heavy metals contained in the real workplace samples from various welding jobs including arc, argon, and carbon dioxide. A total of 25 analytical chemists in the industrial hygiene laboratories participating the quality control program directed by the Korea Industrial Safety Corporation were interviewed by telephone. For the purpose of comparing performance of extracting heavy metals from real workplace samples, a total of 53 welders from 21 workplaces located in Anyang, Uiwang, and Kunpo areas were sampled from the period of March 22, 1999 to April 20, 1999. It was found that the most frequently adopted method for samples from the quality control program was the acid extraction method(40%) followed by the NIOSH 7300 method(36%). The NIOSH method, however, was the dominant method(36%) for samples from workplace followed by the acid extraction method(28%). In this study, two extraction methods, the acid extraction and the microwave digestion, were compared in terms of recovery rate, accuracy, and precision for both manganese and chromium. Both methods produced comparable results for the samples prepared for the quality control program. In contrast, concentrations of two heavy metals determined from real workplace samples pretreated with the microwave digestion method were statis tically significantly higher, manganese(166%) and chromium (200%), than those of utilizing the acid extraction method. These findings were consistent regardless of types of welding techniques used. The results of this study clearly show the importance of verifying the analytical performances of extraction methods for heavy metals not only for the samples from the quality control program but also from the real world samples collected from welding jobs.

  • PDF

Health Risk Assessment of Lead Ingestion Exposure by Particle Sizes in Crumb Rubber on Artificial Turf Considering Bioavailability

  • Kim, Sun-Duk;Yang, Ji-Yeon;Kim, Ho-Hyun;Yeo, In-Young;Shin, Dong-Chun;Lim, Young-Wook
    • Environmental Analysis Health and Toxicology
    • /
    • 제27권
    • /
    • pp.5.1-5.10
    • /
    • 2012
  • Objectives: The purpose of this study was to assess the risk of ingestion exposure of lead by particle sizes of crumb rubber in artificial turf filling material with consideration of bioavailability. Methods: This study estimated the ingestion exposure by particle sizes (more than 250 um or less than 250 um) focusing on recyclable ethylene propylene diene monomer crumb rubber being used as artificial turf filling. Analysis on crumb rubber was conducted using body ingestion exposure estimate method in which total content test method, acid extraction method and digestion extraction method are reflected. Bioavailability which is a calibrating factor was reflected in ingestion exposure estimate method and applied in exposure assessment and risk assessment. Two methods using acid extraction and digestion extraction concentration were compared and evaluated. Results: As a result of the ingestion exposure of crumb rubber material, the average lead exposure amount to the digestion extraction result among crumb rubber was calculated to be $1.56{\times}10^{-4}$ mg/kg-day for low grade elementary school students and $4.87{\times}10^{-5}$ mg/kg-day for middle and high school students in 250 um or less particle size, and that to the acid extraction result was higher than the digestion extraction result. Results of digestion extraction and acid extraction showed that the hazard quotient was estimated by about over 2 times more in particle size of lower than 250 um than in higher than 250 um. There was a case of an elementary school student in which the hazard quotient exceeded 0.1. Conclusions: Results of this study confirm that the exposure of lead ingestion and risk level increases as the particle size of crumb rubber gets smaller.

음식물찌꺼기 산발효산물과 하수슬러지의 혼합비 및 유기물부하가 병합처리에 미치는 영향 (Effects of Mixing Ratio and Organic Loading Rate of Acid Fermented Food Wastes and Sewage Sludge on the Anaerobic Digestion Process)

  • 안철우;박진식;장성호
    • 한국환경농학회지
    • /
    • 제25권3호
    • /
    • pp.247-256
    • /
    • 2006
  • 본 연구에서는 실험실 규모의 혐기성 소화 실험을 통하여 고온산발효를 거친 음식물찌꺼기 산발효액과 하수슬러지의 적정 혼합비와 유기물 부하율에 따른 반응조 운전특성을 분석하여 실제 플랜트에 적용가능성을 검토하여 얻은 결론은 다음과 같다. 음식물지꺼기 고온 산발효액과 하수슬러지를 혼합하여 반연속식으로 혐기성 소화실험을 실시한 결과 유기물 부하율 3.3 gVS/L.d(혼합비 1:1)에서 최적인 것으로 평가되었는데, 이때 SCOD 제거효율은 평균 74.2%, VS 제거효율은 73.6%, 주입된 VS당 생성된 가스량은 $0.440{\ell}/g\;Vs_{add}.d$였으며 평균 메탄 함량은 66.5%로 나타났다. 이는 기존에 음식물찌꺼기를 하수처리장의 중온 소화조에서 처리할 때의 유기물 부하보다 높아 효율성, 경제성에서 유리한 것으로 판단되었다.

골중납 측정의 시료 전처리 (산분해법과 마이크로웨이브 분해법)와 측정 방법 (유도결합 플라즈마 질량분석법과 흑연로 원자 흡수 분광 광도법)의 비교 (Comparisons of sample preparation (acid digestion and microwave digestion) and measurement (inductively coupled plasma mass spectrometry and graphite furnace atomic absorption spectrometry) in the determination of bone lead)

  • 윤충식;최인자;박성균;김록호
    • 분석과학
    • /
    • 제16권2호
    • /
    • pp.152-158
    • /
    • 2003
  • 본 연구는 인체의 골중 납 농도를 측정하는데 필요한 시료 전처리법과 기기 분석법을 평가하기 위하여 수행되었다. 절단한 인간 사체 다리의 뼈를 상온에서의 산 분해법과 마이크로웨이브 분해법 (microwave oven method)을이용하여 납을 추출하였으며, 유도결합 플라즈마 질량분석법 (ICP-MS)과 흑연로 원자 흡수 분광 광도법 (GF-AAS)으로 납 농도를 측정하였다. 표준시료를 이용하여 회수율을 조사한 결과, 산분해 후 ICP-MS로 측정한 경우 높은 회수율을 보였으나, 산분해 후 GF-AAS로 측정한 것은 표준 농도보다 낮은 값을 보였으며, 마이크로웨이브 분해한 경우는 두 측정기기 모두 표준 농도보다 높은 값을 보였다. 뼈 시료의 경우, 산분해 후 ICP-MS로 측정한 납 농도는 GF-AAS의 값과 높은 상관성을 보였으나 (상관계수 = 0.983), GF-AAS가 ICP-MS보다 계통적으로 높은 값을 측정하였다. 마이크로웨이브 분해 역시 두 분석방법이 높은 상관성을 보였으나 (상관계수 = 0.950), 대체로 산분해에 의한 값보다 높은 농도를 보였다. 결론적으로, 상온에서 질산으로 분해 후 ICP-MS를 이용하여 측정한 것이 골중 납 농도를 결정하는데 편이성과 정확성 면에서 가장 효율적인 방법으로 보인다.

새로운 전처리 방법과 ICP-AES에 의한 폴리우레탄 중의 중금속 분석 (Determination of Heavy Metal in Polyurethane by New Digestion Method and ICP-AES)

  • 임헌성;이석근
    • 분석과학
    • /
    • 제17권4호
    • /
    • pp.363-367
    • /
    • 2004
  • A simple and convenient digestion method was developed for the determination of heavy metal in polyurethane sample using only nitric acid in open system without heating. This digestion method had prevented loss of volatile elements of Hg and As and reduced the pretreatment time for the sample digestion. The detection limit is lowered over 10 times than that of microwave digestion method. Recoveries in polyurethane material were 108% for As, 96 ~ 99% for Hg, 102 ~ 103% for Cr, 98 ~ 102% for Pb, 86 ~ 90% for Cd, and 90 ~ 93% for Cu.

원전 발생 고체 방사성폐기물 내 핵종 분석을 위한 극초단파 산분해 장치를 이용한 용액화 조건 (Dissolution Conditions of Solid Radioactive Wastes Generated from NPP for the Analysis of Radionuclides Using a Closed-vessel Microwave Acid Digestion System)

  • 표형열;이정진;전종선;이창헌;지광용
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.158-166
    • /
    • 2004
  • 원자력 발전소에서 발생하는 방사성 폐기물인 이온교환수지, 제올라이트, 활성탄 및 슬러지에 포함된 핵종 분석을 위한 최적의 산분해 조건을 확립하였다. 방사성 폐기물의 분해에는 혼합산을 이용한 밀폐형 극초단파 산분해법을 사용하였으며, 제안한 방법에 따른 산분해 후의 용액은 맑고 색이 없는 투명한 상태임을 확인할 수 있었다. 또한, 산분해 과정을 거친 각각의 용액 시료는 ICP-AES와 AAS를 사용하여 분석하였고, 모의 방사성 폐기물에 첨가한 5종의 금속 원소들은 94% 이상의 높은 회수율을 보여주었다. 화학적 특성을 고려하여 제안된 산분해 조건은 핵종 분석을 위한 효과적인 전처리 방법으로써, 향후 원전의 유형별 방사성 폐기물에 대해 보편적으로 적용될 수 있을 것으로 판단된다.

  • PDF