• Title/Summary/Keyword: Acid chloride

검색결과 1,213건 처리시간 0.023초

혈액희석 체외순환법에 관한 임상적 관찰 -상온하 Rygg-Kyvsgaard 산화기 및 Sigmamotor pump 사용예를 중심으로- (Studies on the Hemodilution Perfusion with Rygg-Kyvsgaard Oxygenator)

  • 손광현
    • Journal of Chest Surgery
    • /
    • 제3권2호
    • /
    • pp.73-90
    • /
    • 1970
  • Clinical perfusion data on 16 cases of cardiopulmonary bypass using Sigmamotor pump and RyggKyvsgaard Oxygenator which performed at Seoul National University Hospital during the period of Aug. 1968 to Aug. 1970 was analized. AIl cases were hemodiluted and the perfusion was carried out under the normothermic condition. The age of the patients ranged between 6 and 43 years. The b:dy weight varied between 18.3 and 54.0 kg and the body surface area between 0.78 and 1. 59$M^2$. The priming solution was consiste:I with fresh ACD blood. Hartmann solution and Mannitol. The average amount of priming was approximately 2242 ml. The average hemodilution rate was 17%. The flow rate ranged from 1.7L to 3.5L/Min/$M^2$ and averaged 2.4L/Min/$M^2$ or 78mI/Min/kg. The duration of perfusion varied from 22 to 110 min with average of 56.9 minutes. Some hemodynamic responses were observed. The arterial pressure dropped immediately after the initiation of partial perfusion and was more marked after the total perfusion foIlowed by gradual increase to the safety level. The central venous pressure reflected the reduced blood volume especially in the cases of prolonged perfusion which lasted over 60 min. In most of the cases, red blood cell count decreased and white blood ceIl count increased after the perfusion. Hemoglobin level was decreased, averaging of 12.5mg%, Hct 3.3% and platelets count of 18% postoperatively. Plasma hemoglobin increased mildly, from pre-perfusion average value of 4. 06mg% to postperfusion value of 22.5mg%. Serum potassium was 4.4mEq/L pre-operatively and was decreased to 3.7mEq/L postoperatively. Five cases showed definite hypopotassemia immediately after the operation. Sodium and chloride decreased mildly. These electrolyte changes are thought to be related with hemodilution. diuretics and reduced blood volume during and after the perfusion. Arterial blood pH value revealed minimal to moderate elevation from preperfusion average value of 7.376 to 7.461 during perfusion and then 7.365 after perfusion. The pC02 and hicarbonate showed minimal to moderately lowered values. The total CO2 was decreased. Buffer base decreased during perfusion (Av. 42.6mEq/L) and further decreased after the perfusion (Av. 40.8mEq/L). These arterial blood acid base changes suggested that the metabolic acidosis was accompanied by respiratory alkalosis during and immediately after the perfusion. Authors belived that the acidosis could more effectively be corrected with the more additional dose of bicarbonate than we used by this study. The chest tune drainage during the first 24 hours following operation was 1158 ml in average. One case (Case No. 15) showd definite bleeding tendency and it was believed that the cause might be due to the defect of heparin and protamine titration. The average urinary out put during 24 hours post-perfusion was 1291ml. One case (Case No. ]) showed definite post perfusion oliguria. As conclusion hemodilution using fresh ACD blood. Hartmann and Mannitol solution added with Bivon and high flow rate unler normothermia. was thought to amelioratc the severity of mctabolic acidosis during and after perfusion with relatively satisfactory effect on the diuresis and bleeding tendency.

  • PDF

LBL법에 의해 TiO2막이 코팅된 광촉매 글라스 비드 제조 (Fabrication of Photocatalyst Glass Beads Coated with TiO2 Thin Film by a Layer-by-Layer Process)

  • 이지선;채유진;이미재;김세기;황종희;임태영;현승균;김진호
    • 한국재료학회지
    • /
    • 제22권7호
    • /
    • pp.379-383
    • /
    • 2012
  • $TiO_2$ thin films consisting of positively charged poly(diallyldimethylammonium chloride)(PDDA) and negatively charged titanium(IV) bis(ammonium lactato) dihydroxide(TALH) were successfully fabricated on glass beads by a layer-by-layer(LBL) self-assembly method. The glass beads used here showed a positive charge in an acid range and negative charge in an alkaline range. The glass beads coated with the coating sequence of(PDDA/TALH)n showed a change in the surface morphology as a function of the number of bilayers. When the number of bilayers(n) of the(PDDA/TALH) thin film was 20, Ti element was observed on the surface of the coated glass beads. The thin films coated onto the glass beads had a main peak of the (101) crystal face and were highly crystallized with XRD diffraction peaks of anatase-type $TiO_2$ according to an XRD analysis. In addition, the $TiO_2$ thin films showed photocatalytic properties such that they could decompose a methyl orange solution under illumination with UV light. As the number of bilayers of the(PDDA/TALH) thin film increased, the photocatalytic property of the $TiO_2$-coated glass beads increased with the increase in the thin film thickness. The surface morphologies and optical properties of glass beads coated with $TiO_2$ thin films with different coating numbers were measured by field emission scanning electron microscopy(FE-SEM), X-ray diffraction(XRD) and by UV-Vis spectrophotometry(UV-vis).

이월오염에 대한 연구 (A Study of Carry Over Contamination in Chematology)

  • 장상우;김남용;류재기;정동진;김기유;박용원;추경복
    • 대한임상검사과학회지
    • /
    • 제37권3호
    • /
    • pp.178-184
    • /
    • 2005
  • Carry over contamination has been reduced in some systems by flushing the internal and external surfaces of the sample probe with copious amount of diluent. It between specimens should be kept as small as possible. A built-in, continuous-flow wash reservoir, which allows the simultaneous washing of the interior and exterior of the syringe needles, addresses this issue. In addition, residual contamination can further be prevented through the use of efficient needle rinsing procedures. In discrete systems with disposable reaction vessels and measuring cuvets, any carry over is entirely caused by the pipetting system. In analyzers with reuseable cuvets or flow cells, carry over may arise at every point through which high samples pass sequentially. Therefore, disposable sample probe tips can eliminate both the contamination of one sample by another inside the probe and the carry over of in specimen into the specimen in the cup. The results of the applicative carry over experiment studied on 21 items for total protein (TP), albumin (ALB), total bilirubin (TB), alkaline phosphatase (ALP), aspratate aminotranferase (AST), alanine aminotranferase (ALT), gamma glutamyl transferase (GGT), creatinine kinase (CK), lactic dehydrogenase (LD), creatnine (CRE), blood urea nitrogen (BUN), uric acid (UA), total cholesterol (TC), triglyceride (TG), glucose (GLU), amylase (AMY), calcium (CA), inorganic phosphorus (IP), sodium (Na), potassium (K), chloride (CL) tests in chematology were as follows. Evaluation of process performance less than 1% in all tests was very good, but a percentage of ALB, TP, TB, ALP, CRE, UA, TC, GLU, AMY, IP, K, Na, and CL was 0%, implying no carry over. Other tests were ALT(-0.08%), GGT(-0.09%), CK(0.08%), LD(0.06%), BUN(0.12%), TG (-0.06%), and CA(0.89%).

  • PDF

분석측정범위의 실증적 평가 (An Empirical Study of the Analytical Measurement Range in Clinical Chemistry)

  • 장상우;이상곤;김영환;송은영;박용원;박병옥;류재기
    • 대한임상검사과학회지
    • /
    • 제38권2호
    • /
    • pp.117-124
    • /
    • 2006
  • The analytical measurement range (AMR) is the range of analyte values that a method can directly measure on a specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. The linearity of the AMR is its ability to obtain test results which are directly proportional to the concentration of analyte in the sample from the upper and lower limit of the AMR. The AMR validation is the process of confirming that the assay system will correctly recover the concentration or activity of the analyte over the AMR. The test specimen must have analyte values which, at a minimum, are near the low, midpoint, and high values of the AMR. The AMR must be revalidated at least every six months, at changes in major system components, and when a complete change in reagents for a procesure is introduced; unless the laboratory can demonstrate that changing the reagent lot number does not affect the range used to report patient test results. The AMR linearity was total protein (0-16.6), albumin (0-8.1), total bilirubin (0-18.1), alkaline phosphatase (0-1244.3), aspartate aminotransferase (0-1527.9), alanine aminotransferase (0-1107.9), gamma glutamyl transpeptidase (0-1527.7), creatine kinase (0-1666.6), lactate dehydrogenase (0-1342), high density lipoprotein cholesterol (0.3-154.3), sodium (35.4-309), creatinine (0-19.2), blood urea nitrogen (0.5-206.2), uric acid (0-23.9), total cholesterol (-0.3-510), triglycerides (0.7-539.6), glucose (0-672.7), amylase (0-1595.3), calcium (0-23.9), inorganic phosphorus (0.03-17.0), potassium (0.1-116.5), chloride (3.3-278.7). We are sure that materials for the AMR affect the evaluation of the upper limit of the AMR in the process system.

  • PDF

택사탕의 항산화와 혈중지질에 대한 효과 (The Effects of Taeksa-tang on Blood Lipid Profile and Anti Oxidation)

  • 이윤진;이은별;김현지;양두화;김영준;안희덕
    • 한방재활의학과학회지
    • /
    • 제31권2호
    • /
    • pp.1-14
    • /
    • 2021
  • Objectives We evaluated the improving effects of Taeksa-tang (TST) using 3T3-L1 cells and C57BL/6 mice were fed on a high-fat diet. Methods The anti-radical activities of TST were studied using 2,2-diphenyl-1-picrylhydrazyl and 2,2'-azino-bis (3-ethylbenzothiazoline-6-sulphonic acid). The content of total polyphenol was measured using Folin-Ciocalteu reagent, whereas aluminum chloride colorimetric method was used for the content of total flavonoid. Moreover, the factors related to lipid profile and the protein expressions such as 𝛽-oxidation and anti-oxidant enzyme were analyzed using serum and western blotting of 3T3-L1 cells. Additionally, we examined lipolysis through glycerol appearance in mouse adipose tissue. Results TST treatment showed strong free radical scavenging activities with half maximal inhibitory concentration and the presence of a amount of total polyphenol and total flavonoid. TST treatment significantly increased factors related to 𝛽-oxidation such as carnitine palmitoyl transferase-1 and uncoupling protein 2 via the phosphorlyation of liver kinase B1 (LKB1) and AMP-activated protein kinase (AMPK). Moreover, the protein expressions of anti-oxidant enzyme and lipolysis were significantly elevated by TST administration. In addition, TST supplementation lowered serum malondialdehyde, triglyceride, and total cholesterol levels compared with the control group. Taken together, these data suggest that TST treatment regulated lipid parameters via the increase of 𝛽-oxidation by LKB1-AMPK signaling pathway. Conclusions TST may have a potential remedy in the prevention and treatment of obesity. Therefore, this study may provide the scientific basis for TST use.

Comparative Efficacy of Synthetic and Natural Tenderizers on Quality Characteristics of Restructured Spent Hen Meat Slices (RSHS)

  • Kantale, Rushikesh Ambadasrao;Kumar, Pavan;Mehta, Nitin;Chatli, Manish Kumar;Malav, Om Prakash;Kaur, Amanpreet;Wagh, Rajesh Vishwanath
    • 한국축산식품학회지
    • /
    • 제39권1호
    • /
    • pp.121-138
    • /
    • 2019
  • In the present study, comparative efficacy of natural as well as synthetic tenderizers on the quality characteristics of restructured spent hen meat slices (RSHS) was studied. Four different batches of RSHS viz. Control (without any tenderizer), T1 (1.25% calcium chloride replacing salt in formulation), T2 and T3 (1.5% each of pineapple rind and fig powder, replacing binder in the formulation) were developed in pre-standardized formulation. Vacuum tumbling was performed for 2.5 h and cooked product (RSHS) was assayed for quality attributes. Samples were packaged in aerobic conditions, stored for 21 days under refrigeration ($4{\pm}1^{\circ}C$) and were evaluated for pH, oxidative and microbial quality parameters at regular interval of 7 days. Water holding capacity of T2 was recorded the highest and significantly higher (p<0.05) than all other samples. The textural attributes of T2 were comparable to T1 but significantly higher (p<0.05) than C and T3. The colour attributes ($L^*$, $a^*$, and $b^*$ value) of T2 and T3 were improved due to use of natural tenderizers. During sensory evaluation, tenderness scores for T2 samples were recorded the highest. Throughout storage period, thiobarbituric acid reactive substances (TBARS), free fatty acids (FFA) and peroxide value (PV) followed an increasing trend for control as well as treated products; however, T2 showed a significantly (p<0.05) lower value than control and other treated samples. It can be concluded that good quality RSHS with better storage stability could be prepared by utilizing 1.5% pineapple rind powder as natural tenderizer.

Suppressive Impact of Ginsenoside-Rg2 on Catecholamine Secretion from the Rat Adrenal Medulla

  • Ha, Kang-Su;Kim, Ki-Hwan;Lim, Hyo-Jeong;Ki, Young-Jae;Koh, Young-Youp;Lim, Dong-Yoon
    • Natural Product Sciences
    • /
    • 제27권2호
    • /
    • pp.86-98
    • /
    • 2021
  • This study was designed to characterize the effect of ginsenoside-Rg2 (Rg2), one of panaxatriol saponins isolated from Korean ginseng root, on the release of catecholamines (CA) in the perfused model of the rat adrenal medulla, and also to establish its mechanism of action. Rg2 (3~30 µM), administered into an adrenal vein for 90 min, depressed acetylcholine (ACh)-induced CA secretion in a dose- and time-dependent manner. Rg2 also time-dependently inhibited the CA secretion induced by 3-(m-chloro-phenyl-carbamoyl-oxy)-2-butynyltrimethyl ammonium chloride (McN-A-343), 1.1-dimethyl-4-phenyl piperazinium iodide (DMPP), and angiotensin II (Ang II). Also, during perfusion of Rg2, the CA secretion induced by high K+, veratridine, cyclopiazonic acid, methyl-1,4-dihydro-2,6-dimethyl-3-nitro-4-(2-trifluoro-methyl-phenyl)-pyridine-5-carboxylate (Bay-K-8644) depressed, respectively. In the simultaneous presence of Rg2 and Nω-nitro-L-arginine methyl ester hydrochloride ʟ-NAME), the CA secretion induced by ACh, Ang II, Bay-K-8644 and veratridine was restored nearly to the extent of their corresponding control level, respectively, compared to those of inhibitory effects of Rg2-treatment alone. Virtually, NO release in adrenal medulla following perfusion of Rg2 was significantly enhanced in comparison to the corresponding spontaneous release. Also, in the coexistence of Rg2 and fimasartan, ACh-induced CA secretion was markedly diminished compared to the inhibitory effect of fimasartan-treated alone. Collectively, these results demonstrated that Rg2 suppressed the CA secretion induced by activation of cholinergic as well as angiotensinergic receptors from the perfused model of the rat adrenal gland. This Rg2-induced inhibitory effect seems to be exerted by reducing both influx of Na+ and Ca2+ through their ionic channels into the adrenomedullary cells as well as by suppressing Ca2+ release from the cytoplasmic calcium store, at least through the elevated NO release by activation of NO synthase, which is associated to the blockade of neuronal cholinergic and AT1-receptors. Based on these results, the ingestion of Rg2 may be helpful to alleviate or prevent the cardiovascular diseases, via reduction of CA release in adrenal medulla and consequent decreased CA level in circulation.

컬럼 비교를 통한 Ferimzone Z 및 E 입체 이성질체의 물질 분리 및 HPLC-MS/MS를 활용한 현미 중 미량잔류분석법 개발 (Column Comparison for the Separation of Ferimzone Z and E Stereoisomers and Development of Trace Residue Analysis Method in Brown Rice Using HPLC-MS/MS)

  • 정문주;김소희;은혜란;이예진;김수민;백재운;이윤희;신용호
    • 한국환경농학회지
    • /
    • 제42권3호
    • /
    • pp.203-210
    • /
    • 2023
  • Ferimzone Z is a fungicide for effectively controlling rice blast. Under light irradiation conditions, it undergoes a rapid conversion to its E-stereoisomer. Given the importance of isomers in risk assessments of residues in crops, an analytical method was developed for individual isomer quantification. A comparative analysis performed using two columns in HPLC-MS/MS demonstrated that the isomers were successfully separated using the Cadenza column. For the brown rice sample preparation, 5 g of the homogenized sample was saturated with 7 mL of water. The sample was then extracted with a 10 mL mixed solvent of acetonitrile and ethyl acetate (1:1, v/v) that contained 0.1% formic acid, and it was subsequently partitioned with magnesium sulfate and sodium chloride. The upper layer was purified using dSPE containing C18 and PSA sorbents. The established method was subjected to method validation, and it showed recovery rates of 90.6-98.8% (RSD ≤ 3.9%) at concentrations of 0.01, 0.1, 2 mg/kg, with a soft matrix effect (%ME) ranging from -3.1% to +6.5%. This method can be employed in monitoring studies of brown rice to determine the conversion ratio from the Z isomers to the E isomers.

Study Analysis of Isocycloseram and Its Metabolites in Agricultural Food Commodities

  • Ji Young Kim;Hyochin Kim;Su Jung Lee;Suji Lim;Gui Hyun Jang;Guiim Moon;Jung Mi Lee
    • 한국환경농학회지
    • /
    • 제42권1호
    • /
    • pp.71-81
    • /
    • 2023
  • An accurate and easy-to-use analytical method for determining isocycloseram and its metabolites (SYN549431 and SYN548569) residue is necessary in various food matrixes. Additionally, this method should satisfy domestic and international guidelines (Ministry of Food and Drug Safety and Codex Alimentarius Commission CAC/GL 40). Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) was used to determine the isocycloseram and its metabolites residue in foods. To determine the residue and its metabolites, a sample was extracted with 20 mL of 0.1% formic acid in acetonitrile, 4 g magnesium sulfate anhydrous and 1 g sodium chloride and centrifuged (4,700 G, 10 min, 4℃). To remove the interferences and moisture, d-SPE cartridge was performed before LC-MS/MS analysis with C18 column. To verify the method, a total of five agricultural commodities (hulled rice, potato, soybean, mandarin, and red pepper) were used as a representative group. The matrix-matched calibration curves were confirmed with coefficients of determination (R2) ≥ 0.99 at a calibration range of 0.001-0.05 mg/kg. The limits of detection and quantification were 0.003 and 0.01 mg/kg, respectively. Mean average recoveries were 71.5-109.8% and precision was less than 10% for all five samples. In addition, inter-laboratory validation testing revealed that average recovery was 75.4-107.0% and the coefficient of variation (CV) was below 19.4%. The method is suitable for MFDS, CODEX, and EU guideline for residue analysis. Thus, this method can be useful for determining the residue in various food matrixes in routine analysis.

LC-MS/MS를 이용한 농산물 중 제초제 Sulfonylurea계 36종 동시 시험법 개발 (Development of the Simultaneous Analysis of 36 Sulfonylurea Herbicide Residues in Agricultural Products Using LC-MS/MS)

  • 이수정;이정미;장귀현;김현경;김지영
    • 한국환경농학회지
    • /
    • 제42권2호
    • /
    • pp.139-151
    • /
    • 2023
  • Sulfonylurea herbicides are widely used in agriculture because they have a long residual period and high selectivity. An analytical method was developed using QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) technique for simultaneous determination of sulfonylurea herbicide residues in agricultural products by liquid chromatography tandem mass spectrometry and for establishment MRL (Maximum Residue Limit) of those herbicides in Korea. Extraction was performed using acetonitrile containing 0.1% formic acid with MgSO4 (anhydrous magnesium sulfate) and NaCl (sodium chloride) and the extract was cleaned up using MgSO4 and C18 (octadecyl). The matrix-matched calibration curves were composed of 7 concentration levels from 0.001 to 0.25 mg/kg and their coefficients of determination (R2) exceeded 0.99. The recoveries of three spiking levels (LOQ, 10LOQ, 50LOQ, n=5) were in the range of 71.7-114.9% with relative standard deviations of less than 20.0% for all the five agriculture products. All validation values met criteria of the European Union SANTE/11312/2021 guidelines and Food and Drug Safety Evaluation guidelines. Therefore, the proposed analytical method was accurate, effective, and sensitive for sulfonylurea herbicide residues determination in agricultural commodities.