• 제목/요약/키워드: Accuracy criteria

검색결과 873건 처리시간 0.026초

심층 합성곱 생성적 적대 신경망을 활용한 하악 제1대구치 가상 치아 생성 및 정확도 분석 (Generation of virtual mandibular first molar teeth and accuracy analysis using deep convolutional generative adversarial network)

  • 배은정;임선영
    • 대한치과기공학회지
    • /
    • 제46권2호
    • /
    • pp.36-41
    • /
    • 2024
  • Purpose: This study aimed to generate virtual mandibular left first molar teeth using deep convolutional generative adversarial networks (DCGANs) and analyze their matching accuracy with actual tooth morphology to propose a new paradigm for using medical data. Methods: Occlusal surface images of the mandibular left first molar scanned using a dental model scanner were analyzed using DCGANs. Overall, 100 training sets comprising 50 original and 50 background-removed images were created, thus generating 1,000 virtual teeth. These virtual teeth were classified based on the number of cusps and occlusal surface ratio, and subsequently, were analyzed for consistency by expert dental technicians over three rounds of examination. Statistical analysis was conducted using IBM SPSS Statistics ver. 23.0 (IBM), including intraclass correlation coefficient for intrarater reliability, one-way ANOVA, and Tukey's post-hoc analysis. Results: Virtual mandibular left first molars exhibited high consistency in the occlusal surface ratio but varied in other criteria. Moreover, consistency was the highest in the occlusal buccal lingual criteria at 91.9%, whereas discrepancies were observed most in the occusal buccal cusp criteria at 85.5%. Significant differences were observed among all groups (p<0.05). Conclusion: Based on the classification of the virtually generated left mandibular first molar according to several criteria, DCGANs can generate virtual data highly similar to real data. Thus, subsequent research in the dental field, including the development of improved neural network structures, is necessary.

Optical diagnosis by near-focus versus normal-focus narrow band imaging colonoscopy in colorectal polyps based on combined NICE and WASP classification: a randomized controlled trial

  • Nisa Netinatsunton;Natcha Cheewasereechon;Tanawat Pattarapuntakul;Jaksin Sottisuporn;Kanet Kanjanapradit;Bancha Ovartlarnporn
    • Clinical Endoscopy
    • /
    • 제55권5호
    • /
    • pp.645-654
    • /
    • 2022
  • Background/Aims: Narrow Band Imaging (NBI) International Colorectal Endoscopic (NICE) and Workgroup Serrated Polyps and Polyposis (WASP) classifications were developed for optical diagnosis of neoplastic and sessile serrated polyps, respectively. Near-focus NBI with NICE combined with WASP criteria for optical diagnosis of colonic polyps has not yet been evaluated. We aimed to compare the accuracy of near-focus NBI (group A) with normal-focus NBI (group B) in real-time optical diagnosis of colorectal polyps using combined NICE and WASP criteria. Methods: Among 362 patients, 118 with 227 polyps were recruited. Groups A and B included 62 patients with 130 polyps (three lost polyps) and 56 patients with 106 polyps (six lost polyps), respectively. Optical diagnoses were compared with pathological reports. Results: The accuracy of optical diagnosis of neoplastic polyps in groups A and B was not significantly different (76% vs. 71%, p=0.52). WASP criteria provided all false positive diagnoses of sessile polyps as serrated polyps in 31 (16.2%) patients. Conclusions: Near-focus NBI was not superior to normal-focus NBI in optical diagnostics of neoplastic polyps using NICE criteria. In our study, WASP classification yielded all false positives in the diagnosis of sessile serrated adenomas/polyps. Routine real-life optical diagnosis of polyps is still unadvisable.

원발성 폐암에서 종격동 림프절 평가에 대한 종격동경 검사의 가치 (The Value of Mediastinoscopy for Evaluation of Mediastinal Lymph Nodes in Bronchogenic Carcinoma : Accuracy of Mediastinoscopy)

  • 오상준;김창호
    • Journal of Chest Surgery
    • /
    • 제24권8호
    • /
    • pp.751-756
    • /
    • 1991
  • For the period from June 1988 to July 1991 we studied 29 patients who were judged to have operable disease before mediastinoscopy on clinical criteria[absence of distant metastases, phrenic or laryngeal nerve paralysis, positive scalene node biopsy, and malignant pleural effusion]. All patients had computed tomography and mediastinoscopy prior to operation. In the present study, the sensitivity, specificity, and accuracy of CT were 92%, 56%, and 72%, respectively. And the sensitivity, specificity, and accuracy of mediastinoscopy were 92%, 100%, and 97%, respectively. We concluded that because of the low accuracy of CT, CT cannot replace mediastinoscopy, and routine mediastinoscopy should be performed in preoperative staging of bronchogenic carcinoma.

  • PDF

A Hierarchical Evaluation for Success Factors of the Mobile-Assisted Language Learning Using AHP

  • Kim, Gyoo-mi;Lee, Sang-jun
    • International Journal of Contents
    • /
    • 제13권3호
    • /
    • pp.25-31
    • /
    • 2017
  • With tremendous advancement of information and communication technologies, mobile learning systems have been widely adopted in language learning contexts, and several frameworks have been developed for identifying and categorizing different factors of mobile-assisted language learning (MALL). However, pre-existing frameworks have limitations when evaluating the importance level of criteria. The purpose of this study is to develop a comprehensive hierarchical framework for identifying and categorizing success factors of MALL and prioritizing them according to the importance level. To do that, AHP method is used to quantitatively estimate weight values of MALL criteria. Results reveal that the priority of MALL criteria is ordered as follows: content, system, learner, language learning. Local weights of each criterion are also analyzed; for example, usefulness, accuracy, and authenticity are critical factors for improving MALL contents. Ease of use and mobility of MALL systems are also considered more critical than other systematic factors. In addition, availability of immediate feedback and self-directness has the highest weight values of importance. The findings of the study are discussed regarding hierarchical orders of MALL criteria and conclude that successful MALL implementation may be achieved if related elements are diversely measured and evaluated. Pedagogical implications and suggestions for further research are also presented.

대안적인 분류기준: 오분류율곱 (Alternative Optimal Threshold Criteria: MFR)

  • 홍종선;김효민;김동규
    • 응용통계연구
    • /
    • 제27권5호
    • /
    • pp.773-786
    • /
    • 2014
  • 본 연구는 ROC 곡선에서 형성되는 면적 형태로 나타나는 분류정확도기준인 오분류율곱(multiplication of false rates; MFR)를 제안한다. MFR 기준과 다른 기준로부터 구한 최적분류점의 분류성과에 대하여 비교 분석한다. 다양한 분포함수에 대하여 최적분류점을 구하고 이에 대응하는 FNR과 FPR을 비교하면서 MFR의 특징과 장점을 유도한다. 일반적인 비용함수를 바탕으로 분류점에 대한 비용비율을 다양한 분류기준을 이용하여 구한다. 비용곡선에 대한 비용비율의 관계를 정리하여 MFR 기준의 장점을 탐색한다. MFR 기준의 정의를 다차원 ROC 분석으로 확장하고 다차원의 다른 분류기준과의 관계를 설명하면서 토론한다.

실배관 파열시험을 통한 부식배관의 파열압력 평가 (The Evaluation of Burst Pressure for Corroded Pipeline by Full Scale Burst Test)

  • 김영표;백종현;김우식;고영태
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.203-210
    • /
    • 2002
  • The transmission pipeline industry spends many millions of dollars annually performing inline inspections, excavating sites of possible corrosion, and repairing or replacing damaged sections of pipe. New criteria fur evaluation of the integrity of corroded pipe have been developed in recent years to help in controlling these costs. These new criteria vary widely in their estimates of integrity and the most appropriate criterion fur a given pipeline is net always clear. This paper presents an overview, comparison and evaluation of acceptability criteria for corrosion deflects in pipelines. By full scale burst tests, this paper has assessed the relative accuracy of each of theses criteria in predicting burst pressure. Many of the criteria appear to be excessively conservative and indicate that deflects must be repaired when none is needed, based upon burst test data.

역설계를 통해 BIM 구축시에 3D 모델링에 대한 세밀도(LoD) 정립 - 지상 LiDAR 활용한 3D 모델링 연구 중심 - (Definition of 3D Modeling Level of Detail in BIM Regeneration Through Reverse Engineering - Case Study on 3D Modeling Using Terrestrial LiDAR -)

  • 채재현;이지영
    • 한국BIM학회 논문집
    • /
    • 제7권4호
    • /
    • pp.8-20
    • /
    • 2017
  • When it comes to set up the BIM through the reverse engineering, the level of detail(LoD) required for finalized outcomes is different from each purpose. Therefore, it is necessary to establish some concrete criteria which describe the definition of LoDs on 3D modeling for the purpose of each reverse engineering. This research shows the criteria of the 1) positional accuracy, 2) generalization level, 3) scale level, 4) scope of description, and 5) the area available for application by classifying LoD from 1 to 6 on 3D modeling for each purpose of reverse engineering. Moreover, through applying those criteria for the 3D point cloud dataset of building made by terrestrial LiDAR, this research finds out the working hour of 3D modeling of reverse engineering by each LoDs according to defined LoD criteria for each level. It is expected that those findings, how those criteria of LoD on reverse engineering are utilized for modeling-workers to decide whether the outcomes can be suitable for their budget, applicable fields or not, would contribute to help them as a basic information.

가격비교사이트 평가기준의 중요도와 만족도 분석 (Perceived Importance and Satisfaction of Evaluation Criteria of the Price Comparison Website)

  • 차경욱
    • 가족자원경영과 정책
    • /
    • 제11권4호
    • /
    • pp.1-20
    • /
    • 2007
  • The purpose of this study was to identify the criteria of evaluating a price-comparison website, and to investigate the consumers' perceived importance and satisfaction of each criterion. Also, it compared both the importance and satisfaction levels based on consumers' socio-economic and Internet-usage characteristics. Data for this study came from a questionnaire completed by consumers (n=417), who had used the price-comparison website, and were analyzed through factor analysis, t-test, and ANOVA. The findings of the study were as follows: First, the evaluation criteria of the price-comparison website were categorized into five variety of information, accuracy, convenience, credibility, and the website system. Second, convenience of searching information was seen by consumers as both the most important and most satisfactory criterion. Variety of information was also considered important. For most of the evaluation criteria, the level of consumers' satisfaction was significantly lower than the level of consumers' recognized importance. Third, consumers in their 20s, students, and housewives were less likely to be satisfied by the price-comparison website overall. Older people were less likely to be satisfied with the convenience of the website, and the higher-income group was less likely to be satisfied with the variety of information on hand.

  • PDF

Influence of biliary stents on the diagnostic outcome of endoscopic ultrasound-guided tissue acquisition from solid pancreatic lesions: a systematic review and meta-analysis

  • Suprabhat Giri;Shivaraj Afzalpurkar;Sumaswi Angadi;Jijo Varghese;Sridhar Sundaram
    • Clinical Endoscopy
    • /
    • 제56권2호
    • /
    • pp.169-179
    • /
    • 2023
  • Background/Aims: This meta-analysis analyzed the effect of an indwelling biliary stent on endoscopic ultrasound (EUS)-guided tissue acquisition from pancreatic lesions. Methods: A literature search was performed to identify studies published between 2000 and July 2022 comparing the diagnostic outcomes of EUS-tissue acquisition (TA) in patients with or without biliary stents. For non-strict criteria, samples reported as malignant or suspicious for malignancy were included, whereas for strict criteria, only samples reported as malignant were included in the analysis. Results: Nine studies were included in this analysis. The odds of an accurate diagnosis were significantly lower in patients with indwelling stents using both non-strict (odds ratio [OR], 0.68; 95% confidence interval [CI], 0.52-0.90) and strict criteria (OR, 0.58; 95% CI, 0.46-0.74). The pooled sensitivity with and without stents were similar (87% vs. 91%) using non-strict criteria. However, patients with stents had a lower pooled sensitivity (79% vs. 88%) when using strict criteria. The sample inadequacy rate was comparable between groups (OR, 1.12; 95% CI, 0.76-1.65). The diagnostic accuracy and sample inadequacy were comparable between plastic and metal biliary stents. Conclusions: The presence of a biliary stent may negatively affect the diagnostic outcome of EUS-TA for pancreatic lesions.

휴대용 광이온화 검출기의 정확도, 정밀도 및 기기간 차이에 대한 실험실 평가 (Laboratory Evaluation of the Accuracy, Precision, and Inter-instrumental Variance of a Portable Photoionization Detector)

  • 최동민;최영은;윤충식;이광원;이윤근;이익모;박정임
    • 한국산업보건학회지
    • /
    • 제22권3호
    • /
    • pp.200-208
    • /
    • 2012
  • Objectives: This study investigated the performance of three separate units of a portable photoionization detector (PID, ppb-RAE 3000) for measuring volatile organic compounds (VOCs) in a laboratory. Methods: A laboratory evaluation of the accuracy, precision, and inter-instrumental variance of three separate units of a portable PID (ppb-RAE 3000) was performed. The evaluation was based on the preparation of a test air sample of known toluene or ethylacetate concentration in a Tedlar$^{(R)}$ bag. The test air sample was monitored and data were logged consecutively by the three PIDs. A certified gas of 50 ppm toluene was also monitored during the test to ensure the reliability of the generated test air sample. Four different concentrations ranging from 0.1 to 2 TLV were used and a series of five measurements for each concentration level was performed. The accuracy was evaluated using National Institute for Occupational Safety and Health (NIOSH) criteria. Results: The results from the oldest ppb-RAE3000 unit among the three test units generally fell outside the NIOSH recommended accuracy criteria of ${\pm}25%$, whereas the other two units produced results which were acceptable at, or greater than, 25 ppm of toluene, or 0.5 TLV. These units also met the NIOSH criteria for some ethylacetate measurements but the results were not consistent. Conclusions: Considering the inconsistent performance of these ppb-RAE 3000 units, this device may not be appropriate for use as an alternative to the standard measurement methods. However, it can serve good survey instruments to identify exposure sources or concentration profiles. For all applications, the ppb-RAE 3000 should be used with frequent calibration checks, additional validation using a reference material, and careful maintenance.