• Title/Summary/Keyword: Accuracy Rate

Search Result 3,386, Processing Time 0.032 seconds

Unsteady Flow Rate Measurement by Using Hydraulic Pipeline Dynamics (유압관로의 동특성을 이용한 비정상 유량계측)

  • 김도태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.411-416
    • /
    • 1999
  • The measurement of unsteady flow rate is of vital importance to clarify and improve the dynamic characteristics in pipeline, hydraulic components and system. There is also demand for a real time flow sensor of ability to measure unsteady flow rate with high accuracy and fast response to realize feedback control of flow rate in fluid power systems. In this paper, we propose an approach for estimating unsteady flow rate through a pipeline and components under high pressure condition. In the method, unsteady flow rate is estimated by using hydraulic pipeline dynamics and the measured pressure values at two distant points along the pipeline. The distributed parameter model of hydraulic pipeline is applied with consideration of frequency dependent viscosity friction and unsteady velocity distribution at a cross section of a pipeline. By using the self-checking functions of the method, the validity is investigated by comparison with the measured and estimated pressure waveforms at the halfway section on the pipeline. The results show good agreement between the estimated flow rate waveforms and theroetical those under unsteady laminar flow conditions. the method proposed here is useful in estimating unsteady flow rate through an arbitray cross section in hydraulic pipeline and components without installing an instantaneous flowmeter.

  • PDF

Effect of a Butterfly Valve on the Uncertainty of Flow Rate Measurement (버터플라이 밸브의 유량측정 불확도에 대한 영향)

  • Yoon, Seok-Ho;Lee, Jung-Ho;Yu, Cheong-Hwan;Park, Sang-Jin;Chung, Chang-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.18-24
    • /
    • 2010
  • For testing large-capacity pumps, the accurate flow rate measurement is needed in the test loop. As a measuring method of flow rate, venturi tube is recommended due to its low pressure loss. However, upstream disturbance of loop component such as a valve has an effect upon the accuracy of flow rate measurement. For controlling flow rate in case of high flow rate and large-scale piping system, a butterfly-type valve is generally used due to its compactness. However, a butterfly valve disturbs downstream flow by generating turbulence, cavities, or abrupt pressure change. In this study, the effect of downstream disturbance of butterfly valve on the flow rate measurement using a venturi tube is investigated. Test loop consists of circulation pump, reservoir, butterfly valve, venturi tube, and reference flow meter. The test is conducted with regard to a different valve opening angle of butterfly valve. According to the valve opening angle, the uncertainty of flow rate measurement is investigated.

Improvement of Land Cover Classification Accuracy by Optimal Fusion of Aerial Multi-Sensor Data

  • Choi, Byoung Gil;Na, Young Woo;Kwon, Oh Seob;Kim, Se Hun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.3
    • /
    • pp.135-152
    • /
    • 2018
  • The purpose of this study is to propose an optimal fusion method of aerial multi - sensor data to improve the accuracy of land cover classification. Recently, in the fields of environmental impact assessment and land monitoring, high-resolution image data has been acquired for many regions for quantitative land management using aerial multi-sensor, but most of them are used only for the purpose of the project. Hyperspectral sensor data, which is mainly used for land cover classification, has the advantage of high classification accuracy, but it is difficult to classify the accurate land cover state because only the visible and near infrared wavelengths are acquired and of low spatial resolution. Therefore, there is a need for research that can improve the accuracy of land cover classification by fusing hyperspectral sensor data with multispectral sensor and aerial laser sensor data. As a fusion method of aerial multisensor, we proposed a pixel ratio adjustment method, a band accumulation method, and a spectral graph adjustment method. Fusion parameters such as fusion rate, band accumulation, spectral graph expansion ratio were selected according to the fusion method, and the fusion data generation and degree of land cover classification accuracy were calculated by applying incremental changes to the fusion variables. Optimal fusion variables for hyperspectral data, multispectral data and aerial laser data were derived by considering the correlation between land cover classification accuracy and fusion variables.

Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

  • Campello, Andrea Fagundes;Goncalves, Lucio Souza;Guedes, Fabio Ribeiro;Marques, Fabio Vidal
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • Purpose: The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). Materials and Methods: An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chisquare test. Results: The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions(P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). Conclusion: CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

Accuracy and Precision of Microwave Oven Digestion/Atomic Absorption Spectrophotometry for Analyzing Airborne Chromium Collected on MCE Filter in Plating Operation (도금공정 크롬시료 분석을 위한 Microwave Oven Digestion/Atomic Absorption Spectrophotometry 방법의 정확도 및 정밀도 평가)

  • Lee, Byung-Kyu;Lee, Ji-Tae;Shin, Yong-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.48-55
    • /
    • 2001
  • The purpose of this study was to evaluate the analytical accuracy and precision of microwave oven digestion/atomi absorption spectrophotometry (AAS) for analyzing airborne chromium collected on mixed cellulose ester membrane (M filter from the work environment, and to compare the accuracy and the precision with those of the National Institute for Occupational Safety and Health (NIOSH) Method #7024 hot plate digestion/AAS method. For this study, field air sample pairs were collected from a electroplating process, and spiked samples in a laboratory were prepared and using these samples. Two digestion methods were comp; and evaluated in terms of recovery rate and bias as indices of accuracy and coefficient of variation as a index of precision. The results and conclusions are as follows. In spiked samples, the accuracies (% mean recoveries) of hot plate/AAS and microwave oven/AAS method were 97.19%, 97.1%, respectively, and the precisions (pooled respectively, and the precisions (pooled coefficient of variance, $CV_{pooled}$) 6.93% and 3.88%, respectively. The biases of hot plate ani microwave oven methods were 4.56 - 14.7% and 2.22 - 7.42% respectively. There was no statistically significant difference between hot plate and microwave oven methods recovery rates of spiked samples (p>0,05). Also, no statistically significant difference was shown among the concentrations of air samples determined by two method (p>0.05). In conclusion, microwave oven/AAS method h excellent accuracy and precision, and advantages such as time-saving and simple procedure in comparison with the classical NIOSH method. Therefore, this method can be use widely to analyze airborne chromium collected on MCE filter from the work environments.

  • PDF

The comparison of accuracy on three-unit fixed dental prosthesis made with CAD/CAM milling machines (치과 캐드캠 밀링장비에 따른 3본브릿지의 정확도 비교)

  • Bae, So-Yeon;Park, Jin-Young;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Myung-Bae;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.9-15
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accuracy of the maxillary three-unit fixed dental prosthesis (FDPs) made using two CAD/CAM milling machines : DCM Group(Dentaim CAD/CAM milling machine), WCM Group(Wieland CAD/CAM milling machine). Methods: Each of 10 duplicate models was scanned by blue light scanner(Identica, Medit, Korea), and the three-unit FDPs (STL file) was designed using DelcamCAD. A total of 20 three-unit FDPs was fabricated, comprising 2 groups of 10 specimens each (shrinkage ratio is 1:1). The first three-unit FDPs STL file was used as a CAD reference model (CRM). Obtained STL files by scanning the inner surface of three-unit FDPs were convened into the point clouds-ASC II files. Discrepancies between the point clouds and CRM were measured by superimposition software. Statistical methods to analyze the data were used non-parametric method. The mean (SD) values were compared by a Mann-Whitney U-test. Type one error rate was set at 0.05. Results: WCM group had small discrepancies with $2.17{\mu}m$ of mean value compared to $4.44{\mu}m$ in DCM group. The accuracy values between the two groups showed a sratistically significant difference (Table 2, p<.05). Conclusion: The accuracy of the three-unit fixed dental prosthesis(FDPs) made of two CAD/CAM milling machines were statistically different. Accuracy with which the prosthesis made of WCM group was superior.

The Effects of Accuracy on Skill Level and Eye-Tracking Type in Golf Putting (숙련도와 시선형태가 골프퍼팅의 정확성에 미치는 영향)

  • Woo, Byung-Hoon;Kim, Chang-Won;Park, Yang-Sun;Lee, Kun-Chun;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.729-738
    • /
    • 2009
  • The purpose of this study was to analyze the impact accuracy and kinematic parameters of skill level and eye-tracking type during putting strokes. For comparison, five elite golfers and five novice golfers participated in this study. Three-dimensional kinematic data were collected for each subject while 10 putting trials were performed for each skill level and eye-tracking type. The APAS system was used to compute the impact accuracy and kinematic parameters of putter heads. The putting stroke was divided into three phases: back swing, downswing, and follow-through. The findings indicated that significant differences were found in skill level as it affected the rate of success. For impact accuracy and the displacement of putter heads, a significant difference was found for the skill level, particularly in backs-wing and follow-through. In addition, the displacement of the putter head had a greater influence on stroke accuracy than on velocity.

Reading Fluency and Accuracy for English Language Acquisition in EFL Context. (외국어교육 환경에서 영어습득을 위한 읽기유창성과 정확성에 관한 연구)

  • Shin, Kyu-Cheol
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.249-256
    • /
    • 2018
  • This study aims to explore efficient foreign language learning paradigm with a focus on reading fluency and accuracy. From a perspective of language acquisition in the foreign language context, the priority in the L2 learning between accuracy and fluency has been a very important issue. Fluency becomes an important issue due to many researchers' interests in the L1 and L2 classroom. Although both accuracy and fluency are crucial, the paradigm shift from fluency to accuracy is necessary in the foreign language teaching. In this context, as an alternative methodology for L2 learners' fluency, the extensive reading approach is provided. A number of studies have suggested that extensive reading program could lead to improvement of L2 learners' reading rate and is an effective approach to improving general language proficiency.

Estimation of Disease Code Accuracy of National Medical Insurance Data and the Related Factors (의료보험자료 상병기호의 정확도 추정 및 관련 특성 분석 -법정전염병을 중심으로-)

  • Shin, Eui-Chul;Park, Yong-Mun;Park, Yong-Gyu;Kim, Byung-Sung;Park, Ki-Dong;Meng, Kwang-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.3 s.62
    • /
    • pp.471-480
    • /
    • 1998
  • This study was undertaken in order to estimate the accuracy of disease code of the Korean National Medical Insurance Data and disease the characteristics related to the accuracy. To accomplish these objectives, 2,431 cases coded as notifiable acute communicable diseases (NACD) were randomly selected from 1994 National Medical Insurance data file and family medicine specialists reviewed the medical records to confirm the diagnostic accuracy and investigate the related factors. Major findings obtained from this study are as follows : 1. The accuracy rate of disease code of NACD in National Medical Insurance data was very low, 10.1% (95% C.I. : 8.8-11.4). 2. The reasons of inaccuracy in disease code were 1) claiming process related administrative error by physician and non-physician personnel in medical institutions (41.0%), 2) input error of claims data by key punchers of National Medical Insurer (31.3%) and 3) diagnostic error by physicians (21.7%). 3. Characteristics significantly related with lowering the accuracy of disease code were location and level of the medical institutions in multiple logistic regression analysis. Medical institutions in Seoul showed lower accuracy than those in Kyonngi, and so did general hospitals, hospitals and clinics than tertiary hospitals. Physician related characteristics significantly lowering disease code accuracy of insurance data were sex, age group and specialty. Male physicians showed significantly lower accuracy than female physicians; thirties and fortieg age group also showed significantly lower accuracy than twenties, and so did general physicians and other specialists than internal medicine/pediatric specialists. This study strongly suggests that a series of policies like 1) establishment of peer review organization of National Medical Insurance data, 2) prompt nation-wide expansion of computerized claiming network of National Medical Insurance and 3) establishment and distribution of objective diagnostic criteria to physicians are necessary to set up a national disease surveillance system utilizing National Medical Insurance claims data.

  • PDF

Developing the Accurate Method of Test Data Assessment with Changing Reliability Growth Rate and the Effect Evaluation for Complex and Repairable Products

  • So, Young-Kug;Ryu, Byeong-Jin
    • Journal of Applied Reliability
    • /
    • v.15 no.2
    • /
    • pp.90-100
    • /
    • 2015
  • Reliability growth rate (or reliability growth curve slope) have the two cases of trend as a constant or changing one during the reliability growth testing. The changing case is very common situation. The reasons of reliability growth rate changing are that the failures to follow the NHPP (None-Homogeneous Poisson Process), and the solutions implemented during test to break out other problems or not to take out all of the root cause permanently. If the changing were big, the "Goodness of Fit (GOF)" of reliability growth curve to test data would be very low and then reduce the accuracy of assessing result with test data. In this research, we are using Duane model and AMSAA model for assessing test data and projecting the reliability level of complex and repairable system as like construction equipment and vehicle. In case of no changing in reliability growth rate, it is reasonable for reliability engineer to implement the original Duane model (1964) and Crow-AMSAA model (1975) for the assessment and projection activity. However, in case of reliability growth rate changing, it is necessary to find the method to increase the "GOF" of reliability growth curves to test data. To increase GOF of reliability growth curves, it is necessary to find the proper parameter calculation method of interesting reliability growth models that are applicable to the situation of reliability growth rate changing. Since the Duane and AMSAA models have a characteristic to get more strong influence from the initial test (or failure) data than the latest one, the both models have a limitation to contain the latest test data information that is more important and better to assess test data in view of accuracy, especially when the reliability growth rate changing. The main objective of this research is to find the parameter calculation method to reflect the latest test data in the case of reliability growth rate changing. According to my experience in vehicle and construction equipment developments over 18 years, over the 90% in the total development cases are with such changing during the developing test. The objective of this research was to develop the newly assessing method and the process for GOF level increasing in case of reliability growth rate changing that would contribute to achieve more accurate assessing and projecting result. We also developed the new evaluation method for GOF that are applicable to the both models as Duane and AMSAA, so it is possible to compare it between models and check the effectiveness of new parameter calculation methods in any interesting situation. These research results can reduce the decision error for development process and business control with the accurately assessing and projecting result.