• Title/Summary/Keyword: Accuracy Rate

Search Result 3,386, Processing Time 0.026 seconds

Analysis of measurement Accuracy up to High Pressure for Various Solid Propellants using Ultrasound (초음파를 이용한 다양한 고체추진제의 고압범위까지의 연소속도 측정 정밀도 분석)

  • Oh, Hyun-Taek;Song, Sung-Jin;Kim, Hak-Joon;Ko, Sun-Feel;Kim, In-Chul;Yoo, Ji-Chang;Jung, Jung-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.265-268
    • /
    • 2008
  • In this study, we measured burning rates of solid propellants which has various burning rates until 5000 psia, and we evaluated measurement accuracy of ultrasonic method by analyzing error of burning rates. Also, We compared result of burning rates by using ultrasonic method with strand burner method so that characteristics of two measurements method are evaluated.

  • PDF

Data Correction For Enhancing Classification Accuracy By Unknown Deep Neural Network Classifiers

  • Kwon, Hyun;Yoon, Hyunsoo;Choi, Daeseon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.9
    • /
    • pp.3243-3257
    • /
    • 2021
  • Deep neural networks provide excellent performance in pattern recognition, audio classification, and image recognition. It is important that they accurately recognize input data, particularly when they are used in autonomous vehicles or for medical services. In this study, we propose a data correction method for increasing the accuracy of an unknown classifier by modifying the input data without changing the classifier. This method modifies the input data slightly so that the unknown classifier will correctly recognize the input data. It is an ensemble method that has the characteristic of transferability to an unknown classifier by generating corrected data that are correctly recognized by several classifiers that are known in advance. We tested our method using MNIST and CIFAR-10 as experimental data. The experimental results exhibit that the accuracy of the unknown classifier is a 100% correct recognition rate owing to the data correction generated by the proposed method, which minimizes data distortion to maintain the data's recognizability by humans.

Evaluating Corrective Feedback Generated by an AI-Powered Online Grammar Checker

  • Moon, Dosik
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.22-29
    • /
    • 2021
  • This study evaluates the accuracy of corrective feedback from Grammarly, an online grammar checker, on essays written by cyber university learners in terms of detected errors, suggested replacement forms, and false alarms.The results indicate that Grammarly has a high overall error detection rate of over 65%, being particularly strong at catching errors related to articles and prepositions. In addition, on the detected errors, Grammarly mostly provide accurate replacement forms and very rarely make false alarms. These findings suggest that Grammarly has high potential as a useful educational tool to complement the drawbacks of teacher feedback and to help learnersimprove grammatical accuracy in their written work. However, it is still premature to conclude that Grammarly can completely replace teacher feedback because it has the possibility (approximately 35%) of failing to detect errors and the limitationsin detecting errors in certain categories. Since the feedback from Grammarly is not entirely reliable, caution should be taken for successful integration of Grammarly in English writing classes. Teachers should make judicious decisions on when and how to use Grammarly, based on a keen awareness of Grammarly's strengths and limitations.

A Comparative Study on the Performance of SVM and an Artificial Neural Network in Intrusion Detection (SVM과 인공 신경망을 이용한 침입탐지 효과 비교 연구)

  • Jo, Seongrae;Sung, Haengnam;Ahn, Byung-Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.703-711
    • /
    • 2016
  • IDS (Intrusion Detection System) is used to detect network attacks through network data analysis. The system requires a high accuracy and detection rate, and low false alarm rate. In addition, the system uses a range of techniques, such as expert system, data mining, and state transition analysis to analyze the network data. The purpose of this study was to compare the performance of two data mining methods for detecting network attacks. They are Support Vector Machine (SVM) and a neural network called Forward Additive Neural Network (FANN). The well-known KDD Cup 99 training and test data set were used to compare the performance of the two algorithms. The accuracy, detection rate, and false alarm rate were calculated. The FANN showed a slightly higher false alarm rate than the SVM, but showed a much higher accuracy and detection rate than the SVM. Considering that treating a real attack as a normal message is much riskier than treating a normal message as an attack, it is concluded that the FANN is more effective in intrusion detection than the SVM.

EFFECT OF IMPRESSION TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS (인상채득방법이 임플란트 주모형의 정확성에 미치는 영향)

  • Kim Young-Oh;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.238-247
    • /
    • 2004
  • Statement of problem: Major objective in making on implant-supported prosthesis is the production of superstructure that exhibits a passive fit when connected to multiple abutments. One requirement to ensure passive fit is to make an accurate impression. Purpose : The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on fxiture level (Group FIX-D), 2) indirect method on fixture level(Group FIX-I), 3) modified indirect method on fixture level(Group FIX-M), 4) direct method on abutment level(Group AB-D) and 5) indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^{(R)}$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results : The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2. In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error. Conclusion: An impression method have more effect on accuracy of master model than an impression level. A modified indirect method showed smallest vertical and horizontal error.

EFFECT OF IMPRESS10N TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS (인상채득법이 임플랜트 주모형의 정확성에 미치는 영향)

  • Kim Young-Oh;Yang Hong-So;Vang Mong-Sook;Park Sang-Won;Park Ha-Ok;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.63-72
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and Method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on future level (Group FIX-D), 2) Indirect method on fixture level(Group FIX-I), 3) Modified indirect method on fixture level(Group FD(-M), 4) Direct method on abutment level(Group AB-D) and 5) Indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^(R)$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results: The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2 In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error.

Proteome Analysis of various types of Panax ginseng using 2-Dimensional Electrophoresis (인삼, 산양삼 및 산삼의 부위별 Proteome분석)

  • We, Jong-Sung;Park, Hee-Soo;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.10 no.2 s.23
    • /
    • pp.5-18
    • /
    • 2007
  • Objectives : The purpose of this study was to obtain an objective differentiating method for various types of Panax ginseng: ginseng, cultivated wild ginseng, and natural wild ginseng which are distinctive according to their growing environment. Methods : The roots, stem, and leaves of several types of ginseng were collected and comparative analysis of proteome was conducted on each part using 2-DE and the results examined. Results : 1. Proteome images of the respective parts within the samples showed spot-matching in most cases, suggesting that they are genetically identical panax ginseng. 2. Similar distribution patters were seen within the different parts of the Panax ginseng: ginseng, Chinese cultivated wild ginseng, and the 5 and 10 years old Korean cultivated wild ginseng. 3. For a quantitative evaluation of spots showing differences among the samples, 102 spots from the roots, 109 spots from the stems, and 132 spots form the leaves which showed a difference were selected and centrifugal identification was conducted. 4. Peculiar proteins from each respective part of the Panax ginseng were identified and the top 20 spots with significant differences were selected and analyzed in order to provide a differentiation rate among the samples. The accuracy rate ranged between 23.0-38.8%. 5. Differentiation rate of the top 10 spots with significant differences showed a 50-85% accuracy rate, and the differentiation rate was especially high for the stem of Chinese cultivated wild ginseng and Korean cultivated wild ginseng.

Development of Unmanned Remote Radiation Detection Module (무인 원격 방사선 검출 모듈 개발)

  • Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.795-801
    • /
    • 2021
  • The designed drone-based unmanned remote radiation detection module was developed according to the needs of the nuclear power plant decommissioning workshop. Using the Geiger-Mueller tube sensitive to low-level radiation measurement, It was manufactured to measure the amount of radiation leaking into and out of the containment vessel. The drone-based radiation detection module weighs less than 200g, It can be operated inside and outside the containment vessel of a nuclear power plant. To check the performance of the designed equipment, a performance evaluation test was conducted with reference to the international standard (IEC-60864). The stability of the radiation detection module designed to meet the needs of the field the statistical rate of change by repeated measurements in the rate of change experiment to evaluate the measurement accuracy was ±4.6%. The accuracy ±7.3% in the linearity experiment to evaluate the dose rate dependence, the linear The figure satisfies the international performance evaluation standard of ±3.5%. The radiation detection module developed in this study is a customized equipment for a nuclear power plant dismantling workshop. It will be helpful for accurate measurement of space dose rate and safety management of radiation worksites in sites with a lot of radiation dust.

Clinical expression of programmed maxillary buccal expansion and buccolingual crown inclination with Invisalign EX30 and SmartTrack aligners and the effect of 1-week vs. 2-week aligner change regimes: A retrospective cohort study

  • Joseph O'Connor;Tony Weir;Elissa Freer;Brett Kerr
    • The korean journal of orthodontics
    • /
    • v.54 no.3
    • /
    • pp.142-152
    • /
    • 2024
  • Objective: This retrospective cohort study aimed to assess and compare the accuracy of 3 different Invisalign® treatment regimens in terms of variations of aligner change frequency and type of aligner material in achieving maxillary dental buccal expansion. Methods: Altogether, 120 adult patients whose treatment involved maxillary dental expansion with Invisalign® were included. The patients were divided into 3 groups, with each group comprising 40 patients as follows: SmartTrack® 1-week changes (ST1), SmartTrack® 2-week changes (ST2), and EX30® 2-week changes (EX2). The groups were assessed by comparing actual changes achieved with those prescribed by ClinCheck®. The rates of clinically significant inaccuracies (CSI) observed for buccal expansion (≥ 0.5 mm) and buccolingual inclination (≥ 2°) during expansion were then determined. Results: In terms of expansion, the ST1 group demonstrated the highest CSI rate at all tooth levels, whereas the ST2 group had the lowest rate of CSI and the lowest mean inaccuracy for each tooth level. In terms of buccolingual inclination, the ST1 group had the highest CSI rate across all tooth levels, whereas the EX2 group had the lowest CSI rate at all tooth levels except for the canine level where the ST2 group had the lowest CSI rate. A tendency toward overexpression of buccal crown inclination, and underexpression of buccal expansion was observed at all tooth levels. Conclusions: Two-week aligner change regimens offer improved accuracy compared with 1-week aligner changes. SmartTrack® 2-week changes were the most accurate for buccal expansion, whereas EX30® 2-week changes were the most accurate for buccolingual inclination.

A Study on Measuring the Speaking Rate of Speaking Signal by Using Line Spectrum Pair Coefficients

  • Jang, Kyung-A;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.3E
    • /
    • pp.18-24
    • /
    • 2001
  • Speaking rate represents how many phonemes in speech signal have in limited time. It is various and changeable depending on the speakers and the characters of each phoneme. The preprocessing to remove the effect of variety of speaking rate is necessary before recognizing the speech in the present speech recognition systems. So if it is possible to estimate the speaking rate in advance, the performance of speech recognition can be higher. However, the conventional speech vocoder decides the transmission rate for analyzing the fixed period no regardless of the variety rate of phoneme but if the speaking rate can be estimated in advance, it is very important information of speech to use in speech coding part as well. It increases the quality of sound in vocoder as well as applies the variable transmission rate. In this paper, we propose the method for presenting the speaking rate as parameter in speech vocoder. To estimate the speaking rate, the variety of phoneme is estimated and the Line Spectrum Pairs is used to estimate it. As a result of comparing the speaking rate performance with the proposed algorithm and passivity method worked by eye, error between two methods is 5.38% about fast utterance and 1.78% about slow utterance and the accuracy between two methods is 98% about slow utterance and 94% about fast utterances in 30 dB SNR and 10 dB SNR respectively.

  • PDF