• Title/Summary/Keyword: Accuracy Measure

Search Result 2,031, Processing Time 0.034 seconds

EFFECT OF IMPRESSION TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS (인상채득방법이 임플란트 주모형의 정확성에 미치는 영향)

  • Kim Young-Oh;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.238-247
    • /
    • 2004
  • Statement of problem: Major objective in making on implant-supported prosthesis is the production of superstructure that exhibits a passive fit when connected to multiple abutments. One requirement to ensure passive fit is to make an accurate impression. Purpose : The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on fxiture level (Group FIX-D), 2) indirect method on fixture level(Group FIX-I), 3) modified indirect method on fixture level(Group FIX-M), 4) direct method on abutment level(Group AB-D) and 5) indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^{(R)}$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results : The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2. In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error. Conclusion: An impression method have more effect on accuracy of master model than an impression level. A modified indirect method showed smallest vertical and horizontal error.

The Accuracy of the ICD-10 Code for Trauma Patients Visiting on Emergency Department and the Error in the ICISS (응급센터에 내원한 외상 환자에 있어 ICD-10 (International Classification of Disease-10)입력의 정확성과 ICISS (International Classification of Disease Based Injury Severity Score)점수의 오류)

  • Lee, Jae Hyuk;Sim, Min Seob
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.108-115
    • /
    • 2009
  • Purpose: We designed a retrospective study to measure the accuracy of the ICD-10 (International Classification of Disease-10) code for trauma patients. We also analyzed the error of the ICISS (International Classification of Disease based Injury Severity Score) due to a missing or an incorrect ICD-10 code. Methods: For the measuring the accuracy of the ICD-10 code for trauma patients in a tertiary teaching hospital's emergency department, two board certified emergency physician performed a retrospective chart review. The ICD-10 code was classified as a main code or a sub-code. The main code was defined as the code of the main department of treatment, and the sub-code was defined as a code other than the main code. We calculated and compared two ICISS for each patient one by using both the existing code and the other by using a corrected code. We compared the proportions of severe trauma (defined as an ICISS less than 0.9) between when the existing code and the corrected code was used respectively. Results: We reviewed the records of 4287 trauma patients who had been treated from July 2008 to November 2008. The accuracy of the main code, the sub-code of emergency department, main-code, the sub-code of hospitalized patients were 97.1%, 59.8%, 98.2% and 57.0%, respectively. Total accuracy of the main and sub-code of emergency department and of hospitalized patients were 91.4% and 58.6%. The number of severe trauma patients increased from 33 to 49 when the corrected code was used in emergency department and increased from 35 to 60 in hospitalized patients. Conclusion: The accuracy of the sub-code was lower than that of the main code. A missing or incorrect subcode could cause an error in the ICISS and in the number of patients with severe trauma.

Position Fixing Accuracy of TDOA Direction Finding Method (TDOA 방위탐지방식의 위치표정 정확도)

  • Lim, Joong-Soo;Chae, Gyoo-Soo
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.373-378
    • /
    • 2014
  • The technology of direction finding is very important to make high position fixing accuracy. TDOA(time difference of arrival) direction finding technology is a high accuracy technology and is used in RF system from 1990. The principle of TDOA is to receive an emitter signal with two antennas, measure the time difference of received signal and then convert the time differences to azimuth angle. For high DF(direction finding) accuracy long basis line and high SNR at receiving system are needed. The DF accuracy and position fixing accuracy are simulated with different SNRs and antenna base lines. We obtain the DF accuracy of $0.51^{\circ}$ at $0^{\circ}$ incident azimuth angle in case of 50m base line and 40dB SNR.

EFFECT OF IMPRESS10N TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS (인상채득법이 임플랜트 주모형의 정확성에 미치는 영향)

  • Kim Young-Oh;Yang Hong-So;Vang Mong-Sook;Park Sang-Won;Park Ha-Ok;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.63-72
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and Method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on future level (Group FIX-D), 2) Indirect method on fixture level(Group FIX-I), 3) Modified indirect method on fixture level(Group FD(-M), 4) Direct method on abutment level(Group AB-D) and 5) Indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^(R)$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results: The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2 In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error.

Comparative Study on Accuracy and Usefulness of Calibration Using CT T.O.D (단층촬영영상을 이용한 T.O.D Calibration의 정확성과 유용성에 관한 비교연구)

  • Seo, Jeong-Beom;Kim, Dong-Hyeon;Lee, Jeong-Beom
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • Uses a Tomographic scan image and Table Object Distance(TOD) price after measuring, uses accuracy and usability of blood vessel diameter(Vessel Diameter) measurement under comparison evaluating boil TOD Calibration. The patient who enforces Prosecuting Attorney abdomen Tomographic scan in the object the superior mesentery artery uses PACS View from abdomen fault image and from blood vessel diameter and the table measures the height until of the blood vessel. Uses Angio Catheter from Angiography(5 Fr.) and enforces is measured from PACS View the height until of the table which and the blood vessel at TOD Calibration price and the size of the superior mesentery artery inputs measures an superior mesentery artery building skill. Catheter Calibration input Agnio Catheter where uses in Angiography the size of the superior mesentery artery at Catheter Calibration price and they measure. Produced an accuracy from monitoring data and comparison evaluated. The statistical program used SPSS. TOD Calibration accuracy was 96.53%, standard deviation is 0.03829. Catheter Calibration accuracy of 92.91%, standard deviation is 0.05085. Represents a statistically significant difference(p = 0). According to age and gender was not statistically significant(p > 0.05). TOD Calibration correlation coefficient R-squared of 88.8%, Catheter Calibration of the R-squared is 75.5%. High accuracy of both methods. Through this study, CT images using the measured distance between the table and the Object, TOD Calibration accuracy higher than two Catheter Calibration was measured. TOD and Catheter Calibration represents a statistically significant difference(p = 0).

  • PDF

A Study on Inspecting Position Accuracy of DACS Pintle (위치자세제어장치의 핀틀 위치정확도 점검 방안 연구)

  • Tak, Jun Mo
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.3
    • /
    • pp.57-64
    • /
    • 2021
  • In the study, to minimize the error on guided control of the KV (Kill Vehicle) and to secure the hit-to-kill performance, a position accuracy inspection for the DACS (Divert and Attitude Control System) actuation system was proposed. The accuracy performance of the DACS actuation system is one of the most important factors in the interception of ballistic missiles. In order to validate actuation control accuracy of DACS system, an inspection item was set for position accuracy, and the inspection system was designed for DACS pintle. To measure the absolute position value of the DACS pintle, an external measurement system was developed using laser displacement sensors. The inspection system was designed so that it can be compared with the actuation command in real time. The proposed position accuracy inspection system can be inspected not only in a DACS system but also in missile system level. The position accuracy inspection was performed using the designed inspection system, and analysis of the inspection result.

Accuracy and time efficiency of conventional and digital outlining of extensions of denture foundation on preliminary casts

  • Anne Kaline Claudino Ribeiro;Aretha Heitor Verissimo;Rodrigo Falcao Carvalho Porto de Freitas;Rayanna Thayse Florencio Costa;Burak Yilmaz;Sandra Lucia Dantas de Moraes;Adriana da Fonte Porto Carreiro
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.3
    • /
    • pp.139-150
    • /
    • 2024
  • PURPOSE. The purpose of this diagnostic study was to assess the accuracy and time efficiency of a digital method to draw the denture foundation extension outline on preliminary casts compared with the conventional technique. MATERIALS AND METHODS. A total of 28 preliminary edentulous casts with no anatomical landmarks were digitized using a laboratory scanner. The outlining of the entire basal seat of the denture was performed on preliminary casts and digitized. Casts with no extension outline were digitized and outlines were drawn using software (DWOS, Straumann). The accuracy of the extension outlined between both techniques was evaluated in the software (GOM Inspect; GOM GmbH) by file superimposition. Specificity and sensitivity tests were applied to measure accuracy. The paired t-test (95% CI) was used to compare the mean total area and the working time. RESULTS. The accuracy ranged from 0.57 to 0.92. The buccal and labial frenulum showed a lower value in the maxilla (0.57); while the area between the retromolar pad and buccal frenulum (0.64) showed a lower score in the mandible. The maxillary denture foundation and the working time for both arches were significantly longer for the digital method (P < .001). CONCLUSION. The denture foundation extension outline exhibited a sufficiently excellent accuracy for the digital method, except for the maxillary anterior region. However, the digital method required a longer working time.

A Method for Detecting Program Plagiarism Comparing Class Structure Graphs (클래스 구조 그래프 비교를 통한 프로그램 표절 검사 방법)

  • Kim, Yeoneo;Lee, Yun-Jung;Woo, Gyun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.37-47
    • /
    • 2013
  • Recently, lots of research results on program comparison have been reported since the code theft become frequent as the increase of code mobility. This paper proposes a plagiarism detection method using class structures. The proposed method constructs a graph representing the referential relationship between the member variables and the methods. This relationship is shown as a bipartite graph and the test for graph isomorphism is applied on the set of graphs to measure the similarity of the programs. In order to measure the effectiveness of this method, an experiment was conducted on the test set, the set of Java source codes submitted as solutions for the programming assignments in Object-Oriented Programming course of Pusan National University in 2012. In order to evaluate the accuracy of the proposed method, the F-measure is compared to those of JPlag and Stigmata. According to the experimental result, the F-measure of the proposed method is higher than those of JPlag and Stigmata by 0.17 and 0.34, respectively.

Comparison of evaluation measures for classification models on binary data (이진자료 분류모형에 대한 평가측도의 특성 비교)

  • Kim, Byungsoo;Kwon, Soyoung
    • The Korean Journal of Applied Statistics
    • /
    • v.32 no.2
    • /
    • pp.291-300
    • /
    • 2019
  • This study investigates the characteristics of evaluation measures for classification models on a binary response variable in order to evaluate their suitability for use. Six measures are considered: Accuracy, Sensitivity, Specificity, Precision, F-measure, and the Heidke's skill score (HSS). Evaluation measures are reformulated using x(ratio of actually 1), y(ratio predicted by 1), z(ratio of both actual and predicted by 1) from the confusion matrix. We suggest two necessary conditions to assess the suitability of the evaluation measures. The first condition is that the measure function is constant for x and y in the case of a random model. The second condition is that the measure function is increasing for z and decreasing for x and y. Since only HSS satisfies the two conditions, that is always appropriate as an evaluation measure for the classification model on the binary response variable, and the other measures should be used within a limited range.

Accuracy and Reliability of The Spine-Pelvis Monitor to Record Three-Dimensional Characteristics of The Spine-Pelvic Motion

  • Kim, Jung-Yong;Yoon, Kyung-Chae;Min, Seung-Nam;Yoon, Sang-Young
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.345-352
    • /
    • 2012
  • Objective: The aim of this study is to evaluate the accuracy and reliability of Spine-Pelvis Monitor(SPM) that was developed to measure 3-dimensional motion of spine and pelvis using tilt sensor and gyro sensor. Background: The main cause of low back pain is very much associated with the task using the low back and pelvis, but no measurement technique can quantify the both spine and pelvis. Method: For testing the SPM, 125 angles from three anatomical planes were measured three times in order to evaluate the accuracy and reliability. The accuracy of SPM in measuring dynamic motion was evaluated using digital motion analysis system. The motion pattern captured by two measuring methods was compared with each other. In result, the percentage error and Cronbach coefficient alpha were calculated to evaluate the accuracy and reliability. Results: The percentage error was 0.35% in flexion-extension on sagittal plane, 0.43% in lateral bending on coronal plane, and 0.40% in twisting on transverse plane. The Cronbach coefficient alpha was 1.00, 0.99 and 0.99 in sagittal, coronal and transvers plane, respectively. Conclusion: The SPM showed less than 1% error for static measurement, and showed reasonably similar pattern with the digital motion system. Application: The results of this study showed that the SPM can be the measuring method of spine pelvis motion that enhances the kinematic analysis of low back dynamics.