• 제목/요약/키워드: Accidents Scenario

검색결과 206건 처리시간 0.026초

수소충전소 및 수소자동차의 사고 시나리오 개발 (Development of Accident Scenarios for Hydrogen Refueling Station and Fuel Cell Vehicle)

  • 박병직;김양균;임옥근
    • 자동차안전학회지
    • /
    • 제15권1호
    • /
    • pp.27-34
    • /
    • 2023
  • The registration rate of eco-friendly vehicles, such as hydrogen vehicles, is increasing rapidly, however, few first responders have experienced related accidents. Accident scenarios at hydrogen refueling stations and hydrogen vehicles on a road were investigated, and the relative importance of each scenario was analyzed using AHP analysis. Leakage, jet flame, and explosion that occurred inside and outside the hydrogen refueling station were reviewed, and the hydrogen gas explosion in the compartment showed the highest importance value. In case of the hydrogen vehicle, traffic accident statistics and actual accidents were used. It was analyzed that the hydrogen vessel explosion on the road due to the failure of TPRD and the leakage in the underground parking area were difficult to respond. The developed accident scenarios are expected to be used for first responder training.

계절별 기상조건에 따른 사고시나리오 모델링 발전방안 - 염소 누출사고를 중심으로 - (Development Plan of Accident Scenario Modeling Based on Seasonal Weather Conditions - Focus on Chlorine Leakage Accident -)

  • 김현섭;전병한
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.733-738
    • /
    • 2017
  • 본 연구에서는 여러 사업장에서 많이 사용되는 대표적 독성 물질인 염소를 누출 물질로 선정하여 화학사고 통계자료에 따라 사고 발생 빈도가 높은 여름철 기상조건을 인자로 한 대안의 시나리오와 기존의 시행방법인 연평균 기상조건을 인자로 한 대안의 시나리오 비교분석을 통해 개선방안을 제시하고자 하였다. 2014년 1월부터 2016년 12월까지 발생한 총 296건의 화학 사고를 분석한 결과 사계절 중 여름에 가장 많은 사고가 발생하는 것으로 조사되었으며 전체 사고 발생건수의 35.81%를 차지하였다. 실제 염소를 취급하는 사업장을 대상으로 위험성 평가 결과 2016년의 경우 연평균 기상조건하에서 산출된 영향범위는 발생원으로부터 반경 712.4 m, 영향범위 내 주민 수는 20,090 명이였으며, 여름철 평균 기상조건하에서 산출된 영향범위는 발생원으로부터 반경 796.2 m, 영향범위 내 주민 수는 27,143 명으로 나타났다. 이와 같은 결과는 특정 조건하에서 현 대안의 시나리오 상의 영향범위가 포괄할 수 없는 부분이 존재함을 의미한다. 따라서 화학 물질별 특성을 고려한 Case Risk Assessment가 이루어져야 한다는 위험성 평가 제도의 발전방향을 제시한다.

BTX 공정에서 Gas Detector Mapping 적정성 검토에 관한 연구 (A Study on Validation for Mapping of Gas Detectors at a BTX Plant)

  • 서지혜;한만형;김일권;천영우
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.168-178
    • /
    • 2017
  • In order to prevent major and chemical accidents, some of the plants which would like to install and operate hazard chemicals handling facilities must submit Off-site Consequence Analysis due to recent arisen leak accidents since 2015. A lot of chemical industrials choose gas detectors as mitigation equipment to early detect gas vapor. The way of placement of gas detectors has two methods; Code-based Design(CBD) and Performance-based Design. The CBD has principles for gas detectors to be installed with consideration for the place that is expected to accumulate gas, and the leak locations according to legal standards and technical guidelines, and has a possibility to be unable to detect by these rules to locate gas detectors by vapor density information. The PBD has two methods; a Geographic Method and Scenario based Method. The Scenario-based Method has been suggested to make up for the Geographic Coverage Method. This Scenario-based Method draw the best optimum placement of gas detectors by considering leak locations, leak speed information, leak directions and etc. However, the domestic placement guidelines just refers to the CBD. Therefore, this study is to compare existing placement location of gas detectors by the domestic CBD with placement locations, coverages and the number of gas detectors in accordance with the Scenario-based Method. Also this study has measures for early detecting interest of Vapor Cloud and suitable placement of gas detectors to prevent chemical accidents. The Phast software was selected to simulate vapor cloud dispersion to predict the consequence. There are two cases; an accident hole size of leak(8 mm) from API which is the highst accident hole size less than 24.5 mm, and a normal leak hole size from KOSHA Guide (1.8 mm). Detect3D was also selected to locate gas detectors efficiently and compare CBD results and PBD results. Currently, domestic methods of gas detectors do not consider any risk, but just depend on domestic code methods which lead to placement of gas detectors not to make personnels recognize tolerable or intolerable risks. The results of the Scenario-based Method, however, analyze the leak estimated range by simulating leak dispersion, and then it is able to tell tolerable risks. Thus it is considered that individuals will be able to place gas detectors reasonably by making objectives and roles flexibly according to situations in a specific plant.

자율주행차량 기능안전 시스템 기반 사고 시나리오 도출 (Traffic Accidents Scenarios Based on Autonomous Vehicle Functional Safety Systems)

  • 김희수;유용식;한효림;조민제;송태진
    • 한국ITS학회 논문지
    • /
    • 제22권6호
    • /
    • pp.264-283
    • /
    • 2023
  • 자율주행차량 사고는 일반차량 사고와 다르게 기술적 문제, 환경, 운전자와의 상호작용 등 다양한 요인에 기인한 사고 발생 가능성이 존재한다. 향후 자율주행 기술의 진보로 기존의 사고원인 이외에도 새로운 이슈들이 대두될 것으로 예상되며, 이에 대응하기 위한 다양한 시나리오 기반의 접근법이 필요하다. 본 연구에서는 자율주행 사고 리포트인, CA DMV collision report와 자율주행모드 해제 보고서인 Disengagement report, 자율주행 실제 사고영상을 수집하여 자율주행차량 교통사고 시나리오를 개발하였다. 시나리오는 ISO 26262의 기능안전 시스템 failure mode에 기반하여 도출되었으며, 자율주행 기능의 다양한 이슈를 반영하고자 하였다. 본 연구를 통해 도출된 자율주행차량 시나리오는 향후 다양한 자율주행차량 교통사고 예방과 대비에 기여할 뿐만 아니라 자율주행 기술의 안전성을 향상시키는 데 중요한 역할을 할 것으로 기대한다.

국내 도로환경과 Euro NCAP VRU Test Protocol v3.0.1을 고려한 AEB(V2P) 시험평가 방법에 관한 연구 (A Study on the Test Evaluation Method of AEB (V2P) Considering the Road Environment in Korea and Euro NCAP Test Protocol v3.0.1)

  • 권병헌;이선봉
    • 자동차안전학회지
    • /
    • 제11권4호
    • /
    • pp.28-38
    • /
    • 2019
  • In the world, traffic accidents and environmental pollution caused by the increase of vehicles are becoming a serious social problem. According to the 2016 data published by the Korea Highway Traffic Authority, Korea owns 49.9 vehicles per 100 people. This is the 28th largest number among the 35 OECD member countries. In addition, the number of deaths from traffic accidents in Korea totaled 4,292, of which 1,714 were caused by traffic accidents involving vehicles and pedestrians. To reduce these human casualties, the automotive industry is constantly working on the development and commercialization of Adaptive Driver Assist System (ADAS). ADAS is the system providing convenience and safeness for drivers. In general, ADAS consists of Autonomous Emergency Braking (AEB), Highway Driving Assist (HDA), Adaptive Cruise Control (ACC), Lane Keeping Assist System (LKAS). Among them, the AEB detects the possibility of collision by the vehicle itself and plays a role of avoiding the collision or reducing the damage through active braking. For such AEB, Euro NCAP has been developing test-evaluation methods for the vulnerable since 2017. Therefore, In this paper analyzes the scenario of Euro NCAP VRU Test Protocol v3.0.1, which will be established in 2020, and proposes test conditions according to the Korean road traffic law. In addition, the reliability of the proposed scenario and test conditions was verified by comparing and analyzing the proposed theoretical evaluation formulas and actual test results.

GIS를 활용한 고속도로 염화수소 가스 누출 시나리오 기반 리스크 평가 (Risk Assessment Based on Highway Hydrogen Chloride Gas Leakage Scenario Using GIS)

  • 김구윤;이재준;윤홍식
    • 대한원격탐사학회지
    • /
    • 제37권3호
    • /
    • pp.591-601
    • /
    • 2021
  • 국내의 화학 산업이 지속적으로 발전이 이루어짐에 따라 화학물질의 취급량과 운송량은 매년 증가하고 있다. 우리나라 도로 화물운송은 90%이상을 차지하고 있으며, 화학물질 운송도 대부분 도로를 통해 이루어지고 있다. 이러한 화학물질 운송차량들은 사고가 발생하게 되면 대형사고로 이어질 수 있다. 운송차량은 1차 피해인 교통사고뿐만 아니라 2차 피해인 환경 피해 요인들인 수질오염, 토양오염 등을 발생시킬 가능성이 높다. 본 연구는 반포IC와 서초IC 구간을 연구지역으로 설정하여 염화수소 가스 누출에 대한 시나리오를 작성하여, ALOHA 프로그램을 사용하여 예측거리를 측정하고 거리에 따라 염화수소 가스가 도달한 시간을 분석하였다. 또한 GIS를 이용해 시간별로 발생한 피해 영역에 대해서 인구밀도를 이용한 리스크 평가를 수행하였다. 이를 통해 피해 영역에 대해서 예방·대응 방안의 필요성을 제시하였다.

열차운행선 지장공사에 대한 위험도 평가 연구 (A Study on the Risk Assessment for Works on/near Operating Line)

  • 정도현;왕종배;이수룡
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1515-1524
    • /
    • 2008
  • In this study, railway accidents from constructing or maintaining works on/near operating line were reviewed during 2005-2007 years. Causes and hazards analysis of these accidents was performed to make an accident scenario for risk assessments. And the risk of worker casualty on/near operating line was quantitatively assessed. Also a constitution method of Risk Matrix for manage tolerable risk level was proposed.

  • PDF

Estimation of Effective Dose to Residents Due to Hypothetical Accidents During Dismantling of Steam Generator

  • Kyeong-Ju Lee;Chang-Lak Kim
    • 방사성폐기물학회지
    • /
    • 제21권2호
    • /
    • pp.183-191
    • /
    • 2023
  • The potential impact of hypothetical accidents that occur during the immediate and deferred dismantling of the Kori Unit 1 steam generator has been comprehensively evaluated. The evaluation includes determining the inventory of radionuclides in the Steam Generator based on surface contamination measurements, assuming a rate of release for each accident scenario, and applying external and internal exposure dose coefficients to assess the effects of radionuclides on human health. The evaluation also includes calculating the atmospheric dispersion factor using the PAVAN code and analyzing three years of meteorological data from Kori NPP to determine the degree of diffusion of radionuclides in the atmosphere. Overall, the effective dose for residents living in the Exclusion Area Boundary (EAB) of Kori NPP is predicted, an it is found that the maximum level of the dose is 0.034% compared to the annual dose limit of 1 mSv for the general public. This implies that the potential impact of hypothetical accidents on human health discussed above is within acceptable limits.

예비위험분석기술(PHA)과 품질기능전개(QFD) 기법을 이용한 철도사고 시나리오 분석기술 개발 (Development of a Railway Accident Scenario Analysis Technique using a Preliminary Hazard Analysis(PHA) and a Quality Function Deployment(QFD))

  • 박찬우;곽상록;왕종배;홍선호;박주남
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.151-156
    • /
    • 2005
  • The objective of this study is to devise an accident scenario analysis method adept at creating accident scenarios at the Preliminary Hazard Analysis(PHA) step of a hazard analysis for railway system. This approach was inspired by the Quality Function Deployment(QFD) method, which is conventionally used in quality management and was used at the systematic accident scenario analysis(SASA) for the design of safer products. In this study, the QFD provides a formal and systematic schema to devise accident scenarios while maintaining objective. The accident scenario analysis method first identifies the hazard factors that cause railway accidents and explains the situation characteristics surrounding the accident. This method includes a feasibility test, a clustering process and a pattering process for a clearer understanding of the accident situation. Since this method enables an accident scenario analysis method to be performed systematically as well as objectively, this method is useful in building better accident prevention strategies. Therefore, this study can serve to reduce railway accident and be an effective tool for a hazard analysis.

  • PDF

전로사고 예방을 위한 인적오류 분석 (A Case Study on the Human Error Analysis for the Prevention of Converter Furnace Accidents)

  • 신운철;권준혁;박재희
    • 대한안전경영과학회지
    • /
    • 제16권3호
    • /
    • pp.195-200
    • /
    • 2014
  • Occupational fatal injury rate per 10,000 population of Korea is still higher among the OECD member countries. To prevent fatal injuries, the causes of accidents including human error should be analyzed and then appropriate countermeasures should be established. There was an severe converter furnace accident resulting in five people death by chocking in 2013. Although the accident type of the furnace accident was suffocation, many safety problems were included before reaching the death of suffocation. If the safety problems are reviewed throughly, the alternative measures based on the review would be very useful in preventing similar accidents. In this study, we investigated the converter furnace accident by using human error analysis and accident scenario analysis. As a result, it was found that the accident was caused by some human errors, inappropriate task sequence and lack of control in coordinating work by several subordinating companies. From the review of this case, the followings are suggested: First, systematic human error analysis should be included in the investigation of fatal injury accidents. Second, multi man-machine accident scenario analyis is useful in most of coordinating work. Third, the more provision of information on system state will lessen human errors. Fourth, the coordinating control in safety should be performed in the work conducting by several different companies.