• Title/Summary/Keyword: Acceptance Tests

Search Result 267, Processing Time 0.025 seconds

The performance evaluation of Stirling cryocooler for thermal imaging system (III) : Thermal environmental test (열상장비용 스터링 극저온 냉동기 특성평가 (III) : 열환경시험)

  • 김양훈;박성제;홍용주;김효봉;고득용;이승홍;나종문
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.163-166
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Linear drive Stilting cryocooler have matured to the stage of undergoing formal qualification test program The thermal environmental test of the Stilting cryocooler is presented in this paper. We performed that low and high temperature keeping test from -4$0^{\circ}C$ to +6$0^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity was determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooling performance of more than 0.8W@80K for 23$^{\circ}C$ ambient temperature with 40 $W_{ac}$ input power.

  • PDF

Installation of Test Equipment for Lightning Surge Complying with International Standard (국제시험규격에 적합한 뇌서지 시험설비 구축)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.360-364
    • /
    • 2006
  • Recently KS documents related to lightning protection were revised complying with the requirements of IEC standards. Lightning protection parts are divided three in IEC, those are arrestor(60099), SPD(61643), and protection facilities(62305). According as international standard is applicable in Korea, type tests, routine tests, and acceptance tests shall be made to demonstrate compliance with the relevant standards. KESRI have installed test equipment which is funded by Ministry of Commerce, Industry and Energy fit for lightning surge test form 2002, and we introduce the test equipments in detail.

  • PDF

Economic Reliability Group Acceptance Sampling Based on Truncated Life Tests Using Pareto Distribution of the Second Kind

  • Aslam, Muhammad;Mughal, Abdur Razzaque;Hanif, Muhammad;Ahmad, Munir
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.5
    • /
    • pp.725-731
    • /
    • 2010
  • Economic Reliability test plans(ERTP) are proposed considering that the life time of the submitted items follow the Pareto distribution of the second kind. For various specified acceptance number, sample size and producer's risk, a minimum test termination time is obtained. A comparison of proposed plan has been made with the existing plan developed by Aslam et al. (2010). The results are explained by tables and example.

Resilience and Adjustment of Retired Husbands and Wives (퇴직한 남편과 그 부인의 탄력성과 적응분석)

  • 김명자
    • Journal of Families and Better Life
    • /
    • v.21 no.6
    • /
    • pp.117-127
    • /
    • 2003
  • This study examined the effect of resilience on the adjustment of retired husbands and their wives. Data was collected from 174 retired husbands and their wives in the Seoul metropolitan area. Collected data were analyzed by mean score, percentile, paired-t tests and regression analyses. The major findings were as follows : 1. There was no significant difference in the adjustments between retired husbands and their wives. 2. Individual resilience, family resilience and social resilience had a strong impact on the adjustment of retired husbands and their wives. Self-esteem, acceptance of retirement, communication between the couple, family cohesion, and retirement policy had a significantly positive impact on the husbands' adjustment. 3. As for the adjustment of the wives, self-esteem, communication between the couple, family cohesion, acceptance of husbands' retirement and religious activity had a significantly positive impact. In summary, this study shows the importance of resilience in the adjustment of retired husbands and their wives.

Development and Comparisons of Hybrid and Failure-Free Period Acceptance Sampling Plans for Gamma Lifetime Distributions (감마 수명분포에 대한 혼합관측과 무고장기간 합격판정 샘플링 계획의 개발 및 비교)

  • Jeong, Hyun-Seok;Park, Jung-Won;Yum, Bong-Jin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.22 no.1
    • /
    • pp.51-63
    • /
    • 1996
  • In this paper, we develop two replacement-type reliability acceptance sampling plans(RASPs) for the gamma lifetime distribution assuming that the shape parameter is known. The two plans are respectively based upon failure-free period and hybrid life tests. We then compare the plans in terms of expected test time to reach a decision, power, etc. Computational results indicate among others that the failure-free period RASP has a shorter expected completion time than the corresponding hybrid RASP when the true scale parameter is 'large'. Finally, sensitivity analyses reveal that the effects of the uncertainties involved in the assumed shape parameter on the producer and the consumer risks are in favorable directions for both parties for both types of plans.

  • PDF

A review of ATKP LEU System's Test procedure (자동열차보호장치(ATP) 지상설비 시험절차에 대한 고찰)

  • Chang, Seok-Gahk;Kim, Jin-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1480-1483
    • /
    • 2009
  • The KNR wayside and onboard subsystem has completed commissioning tests applicable to the Pilot Line section by BOMBARDIER. Andreas Hardt/Assessor and Rod Muttram/VP, Quality & safety approved the Automatic Train Protection(ATP) System. However additional evidences are necessary to come to a Specific Application, which is mandatory to approve the Generic Applications included for commercial running on the overall main line railway with ATP. According to Factory Acceptance Test plan, CBC, CBF, LEU(Line Electronic Unit) made by domestic factory is tested by official recognition test Standards-Setting Agency. It is important to verify quality which form checklist during Factory Acceptance Test. In this paper, review the process, test item, norm and checklist for the CBC, CBF, LEU.

  • PDF

An Economic Design of Reliability Demonstration Test for Product with Lognormal lifetime distribution (수명이 대수정규분포를 따르는 제품에 대한 경제적인 신뢰성 입증시험 설계)

  • Kwon, Young-Il
    • Journal of Applied Reliability
    • /
    • v.12 no.1
    • /
    • pp.47-56
    • /
    • 2012
  • Reliability demonstration tests with zero-failure acceptance criterion are most commonly used in the field of reliability application since they require fewer test samples and less test time compared to other test methods that guarantee the same reliability with a given confidence level. For products with lognormal lifetime distribution, an economic zero-failure test plan is developed that minimizes the total cost related to perform a life test to guarantee a specified reliability of a product with a given confidence level. A numerical example is provided to illustrate the use of the proposed test plan.

An Improved Group Sampling Plan Based on Time-Truncated Life Tests

  • Aslam, Muhammad;Pervaiz, Muhammad Khalid;Jun, Chi-Hyuck
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.3
    • /
    • pp.319-326
    • /
    • 2010
  • In this paper, a new group sampling plan for the lot acceptance is proposed for the time truncated life test, which can be utilized when multi-item testers are implemented. The design parameters are found using the two-point approach such that the producer's and consumer's risks are satisfied simultaneously at the acceptable reliability level and the lot tolerance reliability level, respectively. The case of Weibull distribution is described to illustrate the procedure that can be used when the quality level is expressed by a multiple of the specified life. The advantage of the proposed plan is demonstrated by comparing with the existing plan in terms of the sample size required. The tables are constructed and some examples are given to illustrate the procedure developed here.

Study of the Qualification Test Procedure for the General Avionic Computer for Aircraft (항공기용 임무 통제 컴퓨터(General Avionic Computer)의 품질인증시험절차 수립에 관한 연구)

  • Jo, Jang-Hyen
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.2
    • /
    • pp.119-125
    • /
    • 2001
  • This paper discuss the Qualification Test Procedure which is composed of main functional and environmental tests for the localizing avionics and subsystems, especially the detail test approaches of General Avionics Computed(GAC) through the analysis of related technical data packages for the purpose of performance proof of final products. Quality assurance procedures are properly established with the several kinds of inspections and functional test items. They are called as process inspections, functional test, acceptance test procedure and qualification test procedure. The Qualification test procedure are composed of the analysis of original engineering design concept and shall be performed for the acquisition of the certification of the GAC's quality as well as the aquisition of the related techniques and engineering know-how items.

  • PDF

Analysis of Regulatory Guidance on Electromagnetic Interference of Equipment for Safety of Nuclear Power Plants (원자력발전소 안전을 위한 전자파장해 검증 규제지침 분석)

  • Park, Jae Yoon;Ah, In Beom;Kim, Jaehyun;Choo, Jaeyul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.74-79
    • /
    • 2022
  • This study analyzes the contents of the second revised Regulatory Guide 1.180 (Revision 2) for electromagnetic compatibility qualification published by the U. S. Nuclear Regulatory Commission by comparing them with those of the previous version. The methods and acceptance criteria of both CE101 and CE102 tests pertaining to conductive emission and RE102 test for radiation emission are observed to have been modified in Revision 2. Furthermore, the revised guide is found to afford flexibility in using alternative methods for electromagnetic interference qualification by allowing the combination of different technical base standards.